| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.3 LAdmitted-Finance | -4.00% | ₹1.3 L | L1 | Admitted-Finance |
| 2 | L2₹1.3 LAdmitted-Finance | -2.00% | ₹1.3 L | L2 | Admitted-Finance |
Tender Value
₹1.3 L
EMD Value
₹2,680
Closing Date
7 May 2026, 6:00 pmClosed
Executive Engineer PWD Elect Division II Jodhpur
Executive Engineer PWD Elect Division II Jodhpur
SITC of Air Conditioners at RHC Guest House Jodhpur.
2026_CEPWD_556270_12
NIT No.12 of 2026-27 of E.E. PWD Elect.Dn.II Jodhpur
Open Tender
Electrical Works
30 days
Jodhpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Executive Engineer PWD Elect Division II Jodhpur
₹2,680
Yes
13 May 2026
5 May 2026
8 May 2026
5 May 2026
7 May 2026
5 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply , Installation, Testing and Commissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year Original Equipment Manufacturer (OEM) warranty of both compressor and Printed Circuit Board (PCB). | - | - | - | - |
| 2 | Cooling capacity 6800-7000 Watt, ISEER not less then 3.8 | 2 | Each | 50,605 | ₹1,01,210 |
| 3 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM must ensure that the cable is tested for complaince, either through their in house laboratory accrediated by NABL or by any Govt. laboratory accrediated by NABL and the laboratory's scope of accrediation should cover the requirements and testing procedure as per IS:10810. | - | - | - | - |
| 4 | Un Armoured | - | - | - | - |
| 5 | 2 core x 1.5 Sq.mm | 30 | mtr | 71 | ₹2,130 |
| 6 | Supply, installation, testing and commissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 with 7 mil Glass Cloth and 3 coats of anti UV paint (on area which is exposed to weather) including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. | - | - | - | - |
| 7 | 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | 10 | mtr | 970 | ₹9,700 |
| 8 | 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | 10 | mtr | 714 | ₹7,140 |
| 9 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. | - | - | - | - |
| 10 | 20 mm | 30 | mtr | 131 | ₹3,930 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.