Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹42.2 L+₹36,380 (0.87%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹43.0 L+₹1.1 L (2.73%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹43.9 L+₹2.1 L (4.91%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹44.9 L+₹3.1 L (7.30%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
5 Mar 2020, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-62/2019-20 MANNING AND OPERATION OF DG SETS AND REPAIRS / MAINTENANCE OF ELECTRICAL WIRING, FITTINGS / FIXTURES AND CONNECTED ACCESSORIES AT ZONE-B (TECHNICAL AND DOMESTIC AREAS) AF STATION AMBALA UNDER GE (AF) AMBALA
2020_MES_318666_2
GE AF/AMB-62/2019-20
Open Tender
Civil Works
Item Rate
330 days
GE AF AMBALA
AS PER TENDER DOUCMENTS
10 documents required · 10 mandatory
₹500
Yes
GE AF AMBALA
₹90,000
Yes
23 Mar 2020
19 Feb 2020
7 Mar 2020
19 Feb 2020
5 Mar 2020
21 Feb 2020
Amount
Manning & Operation of substation with 1No. DG set 500kVA by providing 01 (one) FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for ATC complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 4Nos. DG set 250kVA and 1No. 400kVA by providing 01 (one) FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for simulator, 2nd line power house and parameter SS complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 2Nos. DG set 500kVA by providing 01 (one) FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for IACCS building complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 2Nos. DG set 160kVA & 125kVA by providing 01 (one) FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for SRE power house and WWR complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 1No. DG set 125kVA by providing 01 (one) FGM, in 02 (two) shifts of 8hours each (0600 to 1400hrs & 1400hrs to 2200hrs) = 2 FGMs on all days including Sundays and holidays for SITC building complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 2Nos. DG sets 100kVA and 1No. 125kVA by providing 01 (one) FGM, in 02 (two) shifts of 8hours each (0800 to 1600hrs & 1600hrs to 2400hrs) = 2 FGMs on all days including Sundays and holidays for 5Sqn and DSS complex complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 1No. DG sets 62.5kVA by providing 01 (one) FGM, in 01 (one) shift of 8hours on all days including Sundays and holidays for 601 SU parameter complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Notes for serial item Nos. 1 to 7: (i) The timings for each shift shall be as decided by the Engineer-in-charge. No claim whatsoever on this aspect is admissible (ii) 'NIL'or 'Zero' quoting of rates against any items will be treated as 'Non Bonafide'. (iii) The rate quoted shall not be less than minimum fair wages as notified by the Government of India / State Government / Local bodies / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable. In case, the rates quoted by the bidder are less than the minimum fair wages as notified by the Government of India / State Government / Local body / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable, his tender will be treated as 'NON BONAFIDE' and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonafide bids only.
(iv) The minimum wages as derivied by the Deartment including all statutory provision such as ESIC, Bonus, GST, taxes, etc. except the Contractor's profit for skilled person works out to Rs. 705/-per person per shift and for un-skilled person Rs. 552/- per person per shift (v) Increased wages including all other benefits in compliance of statutory provisions shall be paid to the workers by the Contractor. No other claim whatsoever shall be admissible on this account and the bidders shall note this aspect and quote their rates accordingly. It must be noted that in compliance of all statutory provisions, the increase will be passed over to the workers
Taking down carefully batten type copper / alluminium point wiring including fittings such as light fittings, sockets, switches, ceiling roses, regulators, board outlets, etc., and disposing off including making good the disturbed surfaces with its original specifications complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100volts grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories concealed on walls, surface on ceiling etc., and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / fan / exhaust fan point controlled by one switch
One switch socket outlet 3 pin 5/6Amps on same board
One switch socket outlet 3 pin 5Amps on independent board
M&L for point wiring with 2 runs of 2.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100volts grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories concealed on walls, surface on ceiling etc., and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover for 15Amps switch multi-purpose socket oulet on independent board complete all as specified and as directed
M&L for point wiring complete with 2 runs of 1.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100volts grade with multistranded copper conductor drawn through and including white / cream PVC casing and caping of suitable size with all accessories like tee, straight joint, 'L' bend, etc. fixed to walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly complete all as specified and as directed for the following:
One light / fan / exhaust fan point controlled by one switch
One switch socket outlet 3 pin 5/6Amps on same board
One switch socket outlet 3 pin 5Amps on independent board
M&L for point wiring complete with 2 runs of 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100volts grade with multistranded copper conductor drawn through and including white / cream PVC casing and caping of suitable size with all accessories like tee, straight joint, 'L' bend, etc. fixed to walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly for 15Amps switch socket oulet on independent board complete all as specified and as directed
S&F in repairs switch piano flush button type, single pole, ISI marked, one way 6amps, 240V complete all as specified and as directed
S&F in repairs switch piano flush button type, single pole, ISI marked, one way 15amps, 240V complete all as specified and as directed
S&F in repairs socket outlet, 2 in 1, 3 pin, multipurpose 5/6amps flush type, ISI marked, 240V complete all as specified and as directed
S&F in repairs socket outlet, 2 in 1, 3 pin, multipurpose 15amps flush type, ISI marked, 240V complete all as specified and as directed
S&F in repairs ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F in repairs PVC lamp holder, insulated body, bracket holder / angle holder 240V with and including fixing of 10W LED lamp 240V 50Hz (of approved type / design) complete all as specified and as directed
S&F in repairs electronic fan regulator, stepped type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F in repairs LED tube light fitting 1x18W, 230V in commercial channel with powder coated CRCA sheet housing with opal diffuser for LED with LED tube light 20W with high efficient LED in aluminium housing, PF 0.9 , CRI> 70, L 70 with clear & milky diffuser connecting up with twin core twisted flexible copper conductor cable with suitable size down rod with all accessories, internally pre-wired complete all as specified and as directed
S&F in repairs recess/surface mounting LED flat panel 2'x2' with high efficient LED & glare free full window opal diffuser of 36W including connecting up with twin core twisted flexible copper conductor cable with suitable size down rod with all accessories complete all as specified and as directed
S&F in repairs indoor decorative LED batten with opal diffuser with inbuilt LED tube 10W PF 0.9 , CRI> 70, L 70 and driver designed with high transmitting optics for even light distribution IP 20 degree protection having length 620mm with all accessories complete all as specified and as directed
S&F in repairs LED bulk head 10W, PF 0.9 , CRI> 70, L 70 with pressure die cast aluminium housing high efficient LEDs and enclosed with milky diffuser IP 66 protection complete all as specfied and as directed
S&F in repairs security light bracket with 40mm bore GI tubing, light grade, cut and bent to shape required, 1.5m long fixed with including flat iron clamp made of FI 50x6mm, nuts, bolts, washers, etc. duly painted with two coats of synthetic enamel paint over a coat of red oride zinc chrome primer complete all as specfied and as directed
S&F in repairs LED light fittings 45W, input 110 to 280V, with auto shut down on high voltages, life > 50000hrs, operating temp 1 to 50oC IP 65 protection class, luminaries comprising of rectangular shape pressure die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 60W =10% W & rated lumens of min 5000 lumens with 120 degree view angle, the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection, open circuit protection, reverse circuit protection, high voltage protection, protection against 10kV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60598/IS10322 complete all as specified and as directed
M&L for sub-main wiring with two runs of 4sqmm, single core PVC insulated, heavy duty, ISI marked, FRLS, unsheathed cable, 1100V grade, multistranded copper conductor drawn through and including 25mm dia non-metallic rigid PVC conduit with conduit accessories concealed /fixed to walls / roofs / floors, etc. and one run of PVC insulated, heavy duty, ISI marked, unsheathed cable 1100V grade 2.5sqmm for earth continuity copper conductor including taking down of old submain wiring and making good the disturbed surfaces to match with the exisiting surfaces complete all as specified and as directed Note: 2 runs of 4sqmm and one run of 2.5sqmm conductor and one run of PVC conduit shall be measured as one length
M&L for sub-main wiring with two runs of 6sqmm, single core PVC insulated, heavy duty, ISI marked, FRLS, unsheathed cable, 1100V grade, multistranded copper conductor drawn through and including 25mm dia non-metallic rigid PVC conduit with conduit accessories concealed /fixed to walls / roofs / floors, etc. and one run of PVC insulated, heavy duty, ISI marked, unsheathed cable 1100V grade 4sqmm for earth continuity copper conductor including taking down of old submain wiring and making good the disturbed surfaces to match with the exisiting surfaces complete all as specified and as directed Note: 2 runs of 6sqmm and one run of 4sqmm conductor and one run of PVC conduit shall be measured as one length
S&F in repairs sheet metal enclosures for MCB distribution board 230V single pole and neutral 8 way double door, flushed inside the wall with 200Amps rated busbar and making good the disturbed surfaces also matching the exisiting surfaces complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 230V single pole and neutral 4 way double door, flushed inside the wall with 200Amps rated busbar including making good the disturbed surfaces also matching the exisiting surfaces complete all as specified and as directed
S&F in repairs MCCB TPN 415Volts, 100A, 16kA complete all as specified and as directed
S&F in repairs MCB TPN 415Volts, 63A, 10kKA complete all as specified and as directed
S&F in repairs MCB 6 to 32Amp SPN B curve 240Volts 10kA, finger proof terminal, bi-connect termination, label holder, 35mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked fixed on DB complete all as specified and as directed
S&F in repairs MCB 6 to 32Amp SP B curve 240Volts 10kA finger proof terminal, bi-connect termination, label holder, 35mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked fixed on DB complete all as specified and as directed
S&F in repairs one run of 2 core flat cable of size 10sqmm solid aluminium conductor 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1.0m apart with and including 4mm suspension wire complete all as specified and as directed
m/s parmod kamar
SHREE SAI LABOUR CONTRACT CO-OPERATIVE SOCIETY LTD
R D Bansal
M/S Sonu Traders
Raman Electric Trading Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .