Loading…
Loading…
Tender Value
₹19.0 L
EMD Value
₹38,100
Closing Date
1 Oct 2026, 11:00 am
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECT G
12 conditions · 1 needing a document upload
-
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
5 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are requested to go through the following documents which are available in upload/View Documents in Home Page of IREPS portal for works tenders before submitting the e-tender. 1. General Instruction for E-Tenders on works contract--Chapter-I 2. Special Condition-General-Chapter-II
1. I/We have visited the works site and I/We am/are aware of the site conditions. 2. We have read the tender Notice[NIT] details, Tender document along with all the conditions attached/referred to, in this tender document, and agree to abide by the said conditions. 3. We are aware of the fact that the railway reserves the right to amend the scope and value of the contract and to reject[or accept] this offer without assigning any financial liability.
The tender document uploaded as "TenderDocument.pdf" should be read in conjunction with the terms and conditions and should read and followed before quoting the tender.
(A) Interlocking of 4 Nos. of L.C. Gates having TVU more than 20000 in Dhanbad division.(B)Padma Auxiliary work in connection with provision Weigh Bridge (WB) at PADMA due to shifting of WB from KKAS to PADMA.(C)Provision of 02 new / additional Electronic In motion Weigh bridge (EIMWB) at PADH, SNMY.
EL-17-OPEN-2026-27~ECR
EL-17-OPEN-2026-27
Open
Works - General
12 Months
Dhanbad, Jharkhand
₹0
₹38,100
8 Sept 2026
8 Sept 2026
17 Sept 2026
117 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 13,72,837.12 | ||
| — | 64.00 | — | — | ||
| Fixing, connection, testing & Supply of LED Batten, Box type luminaire, with CRCA body, Pre wired for LED tube with supply of Retrofit LED tubular lamp 1X20W,T-8, 4' long, complete with inbuilt LED driver, Make - Crompton, Havells, Bajaj, Polycab (LED Luminarie of the makes as specified above should be as per RDSO's specification for Energy efficient LED based luminaire unit for indoor lighhts to be used in Indian Railway offices and buildings. (Fixing of fitting to be done with proper clamping arrangement as per the site requirement and connection to be done with1.5 sqmm single core copper conductor FRLS by tapping from sub main line including supply of ceiling rose and wires and PVC flexiable pipe) ( The complete system of LED lights (including Driver etc) shall be guaranteed for satisfactorily performance and manufacturing defects for period of 60 months from the date of commissioning or 72 months from the date of suppply, whichever is earlier.(Reference: Railway Board's letter no.2006/Elect(G)/150/5 dated 27.03.15).Warranty: Firm have to submit warranty certificate for five year along with the supply. All fittings should be embossed/permanent sticker with warranty details (supplier/firm's name, LOA No. & Date etc.) at the time of supply. | — | — | — | 63,914.88 | |
| — | 80.00 | — | — | ||
| Wiring of light point with PVC insulated, sheathed & stranded single core copper conductor( FRLS) 1.5mm2 with earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Wire Make-Havells, anchor, Finolex, Polycab ) in PVC pipe/Casing caping, surface/concealed with proper excavation and refilling the wall with proper plastering of the wall or as per the requirment at site with supply & fixing of switch, ceiling rose/angular batten holder etc. (make Havells, anchor,Legrand, Slemens, L&T,or C&S) | — | — | — | 15,630.4 | |
| — | 8.00 | — | — | ||
| Supply,& fixing of Metal body Exhaust Fans (non-capacitor type) copper wound No of poles -4 & sweep size 300 mm (Make-Usha,Havells/crompton, Bajaj ) ( fixing of exhaust fan to be done by cutting the hole of required size in the wall along with supply and grouting of required nut, bolt & waser to suit the Ex-fan as per site requirement, including connection. ) | — | — | — | 10,450.64 | |
| — | 28.00 | — | — | ||
| Wiring of C- Fan/Ex-Fan point with PVC insulated, sheathed & stranded single core copper conductor FRLS 1.5mm2 with earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Wire Make-Havells, anchor, Finolex, Polycab ) in PVC pipe/casing caping, surface/concealed with proper excavation and refilling the wall with proper plastering of the wall as per the requirement at site with supply & fixing of switch, ceiling rose .(make-Havells, anchor,Legrand, Slemens, L&T or C&S) | — | — | — | 8,152.2 | |
| — | 96.00 | — | — | ||
| Wiring of plug point with PVC insulated, sheathed & stranded single core copper conductor FRLS 1.5mm2 with earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Wire Make-Havells, anchor, Finolex, Polycab, Mescab & KEI) in PVC pipepipe/Casing caping, surface/concealed with proper excavation and refilling the wall with proper plastering of the wall or as per the requirment at site with supply & fixing of 5Amp plug & socket switch (make-Havells, Anchor, Legrand, L&T, Seimens or C&S) | — | — | — | 13,630.08 | |
| — | 24.00 | — | — | ||
| Wiring of power plug point 15 Amp with PVC insulated, sheathed and stranded single core, copper conductor FRLS 4mm2 with earthing the point with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable (Wire Make-Havells, anchor, Finolex, Polycab, Mescab & KEI) as required in PVC pipe/casing caping, surface/concealed with proper excavation and refilling the wall or as per the requirment at site with supply & fixing of 15Amp Power Plug & Socket flush type, 5 in 1 including controlling switch.(make-Havells, Anchor, Legrand, L&T, Seimens or C&S) | — | — | — | 5,507.28 | |
| — | 8.00 | — | — | ||
| Wiring of metallic power plug with PVC insulated sheathed & stranded single core copper conductor 4 mm2 (Wire Make-Havells, anchor, Finolex, Polycab) with with earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in PVC pipe in concealed/surface with proper excavation and refilling the wall with proper plastering of the wall with supply & fixing of 20 Amp metallic power plug & socked and 20 Amp MCB-DP. (make-Havells, Anchor, Legrand, L&T, Seimens or C&S) | — | — | — | 5,505.12 | |
| — | 240.00 | — | — | ||
| Wiring of sub-Main Line with FRLS copper wire single core size 6mm2 multistrand with earthing wire 1 No. 1.5 sq. mm FRLS PVC insulated copper conductor single core cable as required in PVC pipe/casing caping, surface/concealed with proper excavation and refilling the wall with proper plastering or as per the requirement at site. (Wire Make-Havells,anchor, Finolex, Polycab, Mescab & KEI) | — | — | — | 14,184 | |
| — | 80.00 | — | — | ||
| Wiring of Main Line with FRLS copper wire single core size 10 mm2 multistrand with earthing wire 1 No. 1.5 sq. mm FRLS PVC insulated copper conductor single core cable as required in PVC pipe/casing caping, surface/concealed with proper excavation and refilling the wall with proper plastering or as per the requirement at site. (Wire Make-Havells,anchor, Finolex, Polycab, Mescab & KEI) | — | — | — | 5,905.6 | |
| — | 80.00 | — | — | ||
| Wiring of Sub main concealed/surface(Normally concealed) in separate heavy gauge PVC conduit pipe 20mm size with single core PVC insulated multi strand copper conductor cable 2 nos of 4 sq.mm each for phase and neutral with earthing wire 1 No. 1.5 sq. mm. The colour coding of cable red for phase,black for neutral must be maintained . No other sub-main & point wiring will be drawn with this sub-main wiring in same PVC pipe. PVC pipe make - Polycab, Pressfit, Precision. Wire/cable make-Havells, Polycab, Finolex, Mescab | — | — | — | 7,989.6 | |
| — | 12.00 | — | — | ||
| Fixing, connection, & Supply of Celling rose and flexible pipe along the sub main line as required for connection of tube fitting, fan etc (Make : Havells, Anchor, C&S, Legrand) | — | — | — | 378.48 | |
| — | 28.00 | — | — | ||
| Installation, connection, testing and Supply of LED Street Light Fitting 72W+/- 5% similar to Havells model OMNIPLUS, made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. Light source - High efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen efficacy of LED >140 lm/W. System Lumen Efficacy 110Lm/W, Electronic driver-Powered by integral, isolated electronic LEDdriver (SMPS based constant current supply)with lower THD, Output Open / Short Circuitprotection, Over Voltage protection, SurgeVoltage protection 10KV with SPD & othersafety test as per IS 15885 Part-2/Sec 13. Warranty 5 years. (Make- Crompton, Havells, Bajaj, Polycab, Philips, Orient & Surya). Connection to be made with PVC insulated S/core stranded alum. FRLS Conductor 2.5mm2 with PG clamp of required size (including supply) | — | — | — | 1,49,289.56 | |
| — | 28.00 | — | — | ||
| Supply of Bend GI pipe of 30mm dia x 4ft long (to suit the street light fitting) as per site requirement and fixing the same on pole with supply of suitable clamp, nut, bolt and washer. | — | — | — | 10,183.88 | |
| — | 8.00 | — | — | ||
| Transportation of 2nd hand rail pole 36 feet long ,from the point of delivery to site of erection and erection of the same with cement concret founadtion ratio 1:3:6 as per drg No EL/T/5- 76 | — | — | — | 18,210.24 | |
| — | 8.00 | — | — | ||
| Scrapping, cleaning & painting of rail pole with 2-coats of Red Oxide primer for entire pole then 2-coatrs of alum. Paint from top up to 5ft above the ground level and 2-coats of Green/Black paint up to 5ft from the ground level | — | — | — | 1,997.44 | |
| — | 8.00 | — | — | ||
| Dismantling/uprooting and transportation of MS Rail Pole to depot | — | — | — | 4,354.08 | |
| — | 8.00 | — | — | ||
| Supply, erection, testing and commissioning of Distribution Board, Double Door, Powder coated with locking arrangement consisting 1No, 32A DP ELCB/RCCB as incoming and 6 Nos x 6A SP MCB and 2 Nos x 20A SP MCB as outgoing Complete. Make - L&T, Havells, Legrand ,C&S, BCH (Fixing of Distribution Board to be done with proper clamping arrangement as per the site requirement (normally concealed) and connection to be done with suitable conductor including supply of PVC flexiable pipe) | — | — | — | 39,642.72 | |
| — | 20.00 | — | — | ||
| Provision (Supply and erection) of Earthing station (RI-7021) as per Drg.No. ETI/ OHE/P/ 7020 or latest (The price shall cover supply and erection of an earth electrode (RI 7021) as per drawing no. ETI/OHE/P/7020. The price shall also cover the provision of a protective concrete Box with removable MS cover. The material should confirm to ACTM vol. II Part II Para 7.1.1 with figure A 3.01. The price shall cover the testing of earth value and painting the value on the earth pit. The earth electrode shall normally be of mild steel galvanized perforated pipe of not less than 44 mm nominal bore and about 3 meter length provided with a spike at one end and welded lug suitable for connecting directly Earth wire/MS flat of required size at other end. The connection of Earth wire/M S flats to each electrode shall be made through M S links by bolted joints, fasteners to be supplied by the contractor. The earth surrounding the electrode shall be chemically treated by alternate layers of fine charcoal and salt at least 150 mm all around. The item should be procured from approved supplier of CORE or RDSO, duly inspected by either RITES or Railway Representative deputed by Sr. Div. Elect.Engineer (G)/ Dhanbad.) | — | — | — | 61,221 | |
| — | 800.00 | — | — | ||
| Providing and fixing 06 SWG / 5.0 MM dia GI wire on surface or in recess for loop earthing of street light poles, connection from earth pit to main junction board/panel, connecting different earth pits etc. Connection and Looping of earth wire to be done with suitable fasteners, nuts bolts and washer as required. | — | — | — | 5,584 | |
| — | 800.00 | — | — | ||
| Supply and laying of of Double Walled Corrugated (DWC) HDPE pipe 90 mm outer dia, 75 mm inner dia with corrugated outer wall and inner fairly smooth wall with compression strength of 450 N, Rodent Repellant, NonFlame Propagation in standard length of 6m including coupler at one end of pipe confirming to IS:16205, part-24, for cable laying | — | — | — | 1,61,832 | |
| — | 3200.00 | — | — | ||
| Trenching, laying and back filling of XLPE cable as per Sr.DEE(G)/DHN's drg. No. EL/486-01 (cable will be supplied by the Railway) | — | — | — | 1,93,792 | |
| — | 40.00 | — | — | ||
| Laying and fixing PVC/XLPE cables of different sizes ranging from 25 sq mm to 120 sq mm on surface of the wall (normally concealed)/steel structure as per the requirement of site with proper clamping arrangement as required at every 1/2 metre. (cable will be supplied by the Railway/Contractor as applicable) | — | — | — | 1,986.8 | |
| — | 40.00 | — | — | ||
| Cable crossing across railway track/pucca road by boring hole at depth of 01 mtr by using 01(one) nos 100mm dia GI pipe(medium grade) with accessories.GI pipe with accessories will be supplied by the contractor. (cable will be supplied by the Railway/Contractor as applicable) | — | — | — | 68,584 | |
| — | 8.00 | — | — | ||
| Fabrication, supply and fixing of covered shed for protection of split AC outdoor unit, made of colour coated trapezoidal steel sheet of size 1200 mm x 1200 mm x 05 mm thick and MS angle of size 40 mm x 40 mm x 5 mm thick along with necessary fasteners (complete) | — | — | — | 28,320 | |
| — | 4.00 | — | — | ||
| Supply, Fixing, connection and Testing of Digital 2 AC timer for split AC of minimum 2.0 ton each (digital display LCD model) latest intelligent micro controller based technology, program - 1hr to 24 hrs. with 30 Amp. heavy duty 2 relay output for 2 nos. ACs auto/manual facility, for single phase. make- Dynamic, saitech systems, om energy savers, nutronics or similar | — | — | — | 29,600 | |
| — | 4.00 | — | — | ||
| Supply & fixing of Busbar Chamber 4-way 100A (Make Havells/C&S/L&T) (Fixing with proper excavation and refilling the wall with proper re-plastering of the wall) | — | — | — | 33,528.28 | |
| — | 4.00 | — | — | ||
| — | 4.00 | — | — | ||
| — | 4.00 | — | — | ||
| — | 4.00 | — | — | ||
| — | 4.00 | — | — | ||
| — | 16.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-17.pdf
ATTACHMENT
GCCApril-2022.pdf
ATTACHMENT
GCCCorrectionslip1to11_compressed.pdf
ATTACHMENT
LEDstreetlight.pdf
ATTACHMENT
LED_Indoor_lighting_specifications_EOI.pdf indoor light specification
ATTACHMENT
LED_Indoor_lighting_specifications_EOI.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .