Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 CrAccepted-AOC | ₹15.8 Cr | L1 | Accepted-AOC Accepted being L1 bidder quoted reasonable and workable rates |
| 2 | L2₹16.4 CrRejected-Finance MIG 2B 83 H NO 65 5 466 GULLAPALEM SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹16.4 Cr | L2 | Rejected-Finance Being not the lowest bidder |
| 3 | L3₹16.5 CrRejected-Finance | ₹16.5 Cr | L3 | Rejected-Finance Being not the lowest bidder |
| 4 | L4₹16.6 CrRejected-Finance | ₹16.6 Cr | L4 | Rejected-Finance Being not the lowest bidder |
| 5 | L5₹16.8 CrRejected-Finance | ₹16.8 Cr | L5 | Rejected-Finance Being not the lowest bidder |
| Sl No | Description | Qty | Unit | M/s Imperial Coastal Infra L6 | SVS PROJECTS L1 | jd constructions L8 | S V S ENTERPRISES L3 | SRI SURYA PROJECTS L2 | anjaliinfratech L11 | VENKATA SAI SRINIVASA CONSTRUCTIONS PRIVATE LIMITED L7 | vijay infraprojects pvt ltd L9 | B DURGA REDDY INFRASTRUCTURES PRIVATE LIMITED L4 | DES RAJ AND SONS BUILDERS PVT LTD L12 | Komal Buildcon Pvt. Ltd. L14 | CHHABINDRA KUMAR PRADHAN L13 | PMR CONSTRUCTIONS L10 | ANANDA PROFIES PRIVATE LIMITED L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Lump sum amount worked out by the contractor for "BUILDINGS & STRUCTURES" as listed in Schedule 'A' Part-I on Serial Page No. 42(R) | 1 | Lump sum | 6,20,00,000 ₹6.2 Cr | 6,07,19,999 ₹6.1 Cr | 6,74,49,500 ₹6.7 Cr | 6,43,77,100 ₹6.4 Cr | 7,38,00,000 ₹7.4 Cr | 7,06,08,434 ₹7.1 Cr | 6,88,04,300 ₹6.9 Cr | 6,78,10,220 ₹6.8 Cr | 7,16,27,700 ₹7.2 Cr | 6,97,26,174 ₹7.0 Cr | 7,95,02,470 ₹8.0 Cr | 7,00,85,994 ₹7.0 Cr | 6,35,35,460 ₹6.4 Cr | 7,00,00,000 ₹7 Cr |
| 2.00 | Lump sum amount worked out by the contractor for "DEMOLITION/DISMANTLING" as listed in Schedule 'A' Part-II on Serial Page No. 44(R) | 1 | Lump sum | 2,25,000 ₹2.3 L | 3,55,199 ₹3.6 L | 4,25,200 ₹4.3 L | 3,61,028.01 ₹3.6 L | 1,93,000 ₹1.9 L | 4,08,437 ₹4.1 L | 3,74,490 ₹3.7 L | 3,92,980 ₹3.9 L | 4,13,900 ₹4.1 L | 4,31,325 ₹4.3 L | 4,43,150 ₹4.4 L | 4,57,921 ₹4.6 L | 4,38,550 ₹4.4 L | 3,95,000 ₹4.0 L |
| 3.00 | Lump sum amount worked out by the contractor for "SITE CLEARANCE / AREA DEVELOPMENT / EARTH WORK EXCAVATION" as listed in Schedule 'A' Part-III on Serial Page No. 46(R) | 1 | Lump sum | 68,00,000 ₹68 L | 64,49,999 ₹64.5 L | 72,18,300 ₹72.2 L | 59,66,196.69 ₹59.7 L | 51,23,377 ₹51.2 L | 69,11,983 ₹69.1 L | 63,57,970 ₹63.6 L | 66,50,500 ₹66.5 L | 70,27,400 ₹70.3 L | 76,20,887 ₹76.2 L | 74,93,500 ₹74.9 L | 77,49,396 ₹77.5 L | 73,98,840 ₹74.0 L | 65,00,000 ₹65 L |
| 4.00 | Lump sum amount worked out by the contractor for "PILE FOUNDATION" as listed in Schedule 'A' Part-IV on Serial Page No. 47(R) | 1 | Lump sum | 4,00,00,000 ₹4 Cr | 3,69,59,999 ₹3.7 Cr | 4,03,57,900 ₹4.0 Cr | 4,39,62,029.58 ₹4.4 Cr | 3,84,77,256 ₹3.8 Cr | 4,07,10,010 ₹4.1 Cr | 4,39,13,530 ₹4.4 Cr | 4,18,78,760 ₹4.2 Cr | 3,26,34,000 ₹3.3 Cr | 4,32,55,712 ₹4.3 Cr | 5,32,80,180 ₹5.3 Cr | 4,40,42,185 ₹4.4 Cr | 4,30,24,910 ₹4.3 Cr | 4,00,00,000 ₹4 Cr |
| 5.00 | Lump sum amount worked out by the contractor for "INTERNAL WATER SUPPLY" as listed in Schedule 'A' Part-V on Serial Page No. 49(R) | 1 | Lump sum | 50,000 ₹50,000 | 59,999 ₹59,999 | 40,200 ₹40,200 | 32,214.56 ₹32,214.56 | 35,707 ₹35,707 | 37,317 ₹37,317 | 35,400 ₹35,400 | 35,880 ₹35,880 | 39,100 ₹39,100 | 39,163 ₹39,163 | 40,140 ₹40,140 | 41,838 ₹41,838 | 38,740 ₹38,740 | 25,000 ₹25,000 |
| 6.00 | Lump sum amount worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule 'A' Part-VI on Serial Page No. 51(R) | 1 | Lump sum | 9,00,000 ₹9 L | 7,79,999 ₹7.8 L | 8,90,200 ₹8.9 L | 7,95,692.16 ₹8.0 L | 6,38,925 ₹6.4 L | 8,59,092 ₹8.6 L | 7,84,060 ₹7.8 L | 8,26,630 ₹8.3 L | 8,66,600 ₹8.7 L | 9,40,571 ₹9.4 L | 9,33,190 ₹9.3 L | 9,63,174 ₹9.6 L | 9,26,530 ₹9.3 L | 8,65,000 ₹8.7 L |
| 7.00 | Lump sum amount worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule 'A' Part-VII on Serial Page No. 52(R) | 1 | Lump sum | 5,63,800 ₹5.6 L | 5,00,999 ₹5.0 L | 5,61,600 ₹5.6 L | 4,96,881.68 ₹5.0 L | 3,19,800 ₹3.2 L | 5,42,513 ₹5.4 L | 4,94,680 ₹4.9 L | 5,22,050 ₹5.2 L | 5,46,800 ₹5.5 L | 5,73,495 ₹5.7 L | 5,89,450 ₹5.9 L | 6,08,240 ₹6.1 L | 5,85,620 ₹5.9 L | 5,50,000 ₹5.5 L |
| 8.00 | Lump sum amount worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule 'A' Part-VIII on Serial Page No. 55(R) | 1 | Lump sum | 14,50,000 ₹14.5 L | 12,83,999 ₹12.8 L | 13,90,200 ₹13.9 L | 11,86,126.54 ₹11.9 L | 12,36,191 ₹12.4 L | 13,46,878 ₹13.5 L | 12,24,490 ₹12.2 L | 12,96,050 ₹13.0 L | 13,53,400 ₹13.5 L | 14,24,547 ₹14.2 L | 14,64,460 ₹14.6 L | 15,10,057 ₹15.1 L | 14,57,990 ₹14.6 L | 14,00,000 ₹14 L |
| 9.00 | Lump sum amount worked out by the contractor for "PATH/ HARDSTANDING" as listed in Schedule 'A' Part-IX on Serial Page No. 57 | 1 | Lump sum | 2,40,00,000 ₹2.4 Cr | 1,73,39,999 ₹1.7 Cr | 1,67,27,800 ₹1.7 Cr | 1,59,70,229.93 ₹1.6 Cr | 1,48,01,310 ₹1.5 Cr | 1,81,11,568 ₹1.8 Cr | 1,56,14,800 ₹1.6 Cr | 1,91,20,740 ₹1.9 Cr | 1,72,58,900 ₹1.7 Cr | 1,93,42,112 ₹1.9 Cr | 1,96,83,970 ₹2.0 Cr | 1,83,05,854 ₹1.8 Cr | 1,98,79,360 ₹2.0 Cr | 1,50,00,000 ₹1.5 Cr |
| 10.00 | Lump sum amount worked out by the contractor for "AREA DRAINAGE" as listed in Schedule 'A' Part-X on Serial Page No. 59(R) | 1 | Lump sum | 3,86,200 ₹3.9 L | 4,19,999 ₹4.2 L | 5,08,100 ₹5.1 L | 4,19,719.53 ₹4.2 L | 3,61,575 ₹3.6 L | 4,85,794 ₹4.9 L | 4,47,580 ₹4.5 L | 4,67,420 ₹4.7 L | 4,94,700 ₹4.9 L | 5,12,579 ₹5.1 L | 5,26,460 ₹5.3 L | 5,44,650 ₹5.4 L | 5,19,230 ₹5.2 L | 4,50,000 ₹4.5 L |
Tender Value
₹14.4 Cr
EMD Value
₹10.5 L
Closing Date
25 Aug 2025, 6:00 pmClosed
Brig Sushil Kumar DDG and CE
DDG CE DGNP Naval Base post Visakhapatnam 530014
AUGMENTATION OF OPERATIONAL FACILITY
2025_MES_711290_1
DDG CE V TOKEN 01 OF 2025- 2026
Open Tender
Civil Works
365 days
Visakhapatnam
As per NIT
8 documents required · 8 mandatory
₹3,000
DGNP
₹10.5 L
Yes
DDG and CE Conference hall
28 Nov 2025
29 May 2025
1 Sept 2025
29 May 2025
25 Aug 2025
11 Aug 2025
29 May 2025 - 12 Jun 2025
13 Jun 2025
Amount
Lump sum amount worked out by the contractor for "BUILDINGS & STRUCTURES" as listed in Schedule 'A' Part-I on Serial Page No. 42(R)
Lump sum amount worked out by the contractor for "DEMOLITION/DISMANTLING" as listed in Schedule 'A' Part-II on Serial Page No. 44(R)
Lump sum amount worked out by the contractor for "SITE CLEARANCE / AREA DEVELOPMENT / EARTH WORK EXCAVATION" as listed in Schedule 'A' Part-III on Serial Page No. 46(R)
Lump sum amount worked out by the contractor for "PILE FOUNDATION" as listed in Schedule 'A' Part-IV on Serial Page No. 47(R)
Lump sum amount worked out by the contractor for "INTERNAL WATER SUPPLY" as listed in Schedule 'A' Part-V on Serial Page No. 49(R)
Lump sum amount worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule 'A' Part-VI on Serial Page No. 51(R)
Lump sum amount worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule 'A' Part-VII on Serial Page No. 52(R)
Lump sum amount worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule 'A' Part-VIII on Serial Page No. 55(R)
Lump sum amount worked out by the contractor for "PATH/ HARDSTANDING" as listed in Schedule 'A' Part-IX on Serial Page No. 57
Lump sum amount worked out by the contractor for "AREA DRAINAGE" as listed in Schedule 'A' Part-X on Serial Page No. 59(R)
Lump sum amount worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule 'A' Part-XI on Serial Page No. 61(R)
Lump sum amount worked out by the contractor for "COMPOUND WALL/GATE/FENCING" as listed in Schedule 'A' Part-XII on Serial Page No. 64(R)
Lump sum amount worked out by the contractor for "FIRE FIGHTING SYSTEM" as listed in Schedule 'A' Part-XIII on Serial Page No. 65(R)
Lump sum amount worked out by the contractor for "LIGHTNING PROTECTION" as listed in Schedule 'A' Part-XIV on Serial Page No. 66
Lump sum amount worked out by the contractor for "AIR CONDITIONING" as listed in Schedule 'A' Part-XV on Serial Page No. 67(R)
Schedule "A" Part - XVI: [Miscellaneous Items] [Pile Foundation, Internal Water Supply, Internal Electrification, External Water Supply, External Electrification, Path/Hard Standing, Area Drainage, Sewage Disposal, Compound Wall/Gate/Fencing and Fire Fighting System]: [To be quoted by the bidder.]
Removing building materials etc. (other than spoil payable under Earthwork) outside MD land at GVMC designated places exc. 10km and not exc. 15km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed.
M&L for drilling or boring for 1000mm nominal dia bored cast-in-situ piles through any or all types of strata i.e. soft/loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks/rocks etc., (except hard rock for socketing depth) upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials outside MD land at GVMC designated places exc 10km and not exc. 15km, as directed, complete all as specified and as directed by Engineer-in-Charge.
All as per Serial Item No. 17 here in before but through hard rock for founding minimum 2D (Where D is dia of pile) metre depth for 1000mm nominal dia of piles, complete. Notes for Item Nos. 17 & 18:- (i) The depth of boring for piles shall be measured from existing ground level/bed level/ river bed level to the approved founding level. (ii) It shall be ensured that the waste bentonite slurry/ drilled or bored material is pumped off from the premises to locations shown by GE to contractor at his own cost. (iii) All channels/tanks made for bentonite circulations shall be filled with approved moorum obtained by contractor at his cost after clearing all bentonite cakes. (iv) The contractor may use any approved method as approved by GE for boring without any extra cost to the Govt. The rates for boring of piles shall be inclusive of any method/ casing that may be used by the contractor for bored piles. Nothing extra shall be paid. (v) For the purpose of payment of boring/drilling, description of hard rock shall be as given in SSR Part-I specification. (vi) The rate quoted by the contractor shall be inclusive of the rates for the shifting and setting up of piling rig as many times as required.
Carrying out initial vertical load tests in compression on test pile of 1000mm dia as per standard procedure laid down in IS-2911 by static load test method, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc. as specified and as directed by GE and submission of reports for a test load of 886 tonne in non-working areas in the vicinity of site, including the cost of new piles with specification as same as working pile with minimum depth of socketing into the hard rock 2D (Where D is dia of pile) depth, complete all as specified and as directed by Engineer-in-Charge. Note: Load required for testing as per IS shall be arranged by the contractor and test pile shall be abandoned after testing.
Carrying out routine vertical load tests in compression on test pile of 1000mm dia pile (working pile) as per standard procedure given in IS-2911 (Part IV) by static load test method , including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc. and submission of reports for a test load of 531.60 tonne, complete all as specified and as directed by Engineer-in-Charge. Note: Load required for testing as per IS shall be arranged by the contractor
Carrying out initial lateral load test in lateral thrust on test of 1000 mm dia as per slandered procedure laid down IS-2911 (Part IV) by static load test method including construction of test cap, as necessary, dismantling the cap after the test and cleaning the site and maintaining complete record of load deflection etc. as specified and as directed by GE and submission of reports for a test load of 3.44 tones on non-working area in the vicinity of site, including the cost of new piles and necessary number of reaction pile/any other suitable reaction setup with the test pile having specifications as same as working pile with minimum depth of socketing into the hard rock 2D (Where D is dia of pile ) depth complete all as specified and directed by Engineer-in-Charge. NOTE: Load required for testing as per IS shall be arranged by the contractor and test pile shall abandoned after testing.
Carrying out routine lateral load test in Lateral thrust on test of 1000 mm dia (working pile) as per slandered procedure laid down IS-2911 (Part IV) by static load test method including construction of test cap, as necessary, dismantling the cap after the test and cleaning the site and maintaining complete record of load deflection etc. as specified and as directed by GE and submission of reports for a test load of 1.375 tones complete all as specified and as directed by Engineer-in-Charge. NOTES: (i) The rate includes necessary setup/reaction pile/bearing etc. necessary to apply lateral loads on working pile. (ii) Load required for testing as per IS shall be arranged by the contractor.
Supply only of hard drawn PVC Coated MS Galvanised steel wire chain link fencing of wire mesh (Nominal Pitch of wire) not exc 100mm, plain wire, dia of each wire each way 2.5mm after PVC coating, dia will be 4.00mm, complete all as specified and as directed.
M&L for Point wiring with 1.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade confirming to IS 694: 1977, drawn in and including rigid PVC conduit not less than 20mm bore, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes with and including factory made MS sunken boxes made out of MS sheet of thickness not less than 1.6mm with earth dolly and bakelite laminated sheet 3mm thick ISI mark for fixing of switches, including one run of 1.5 Sq.mm single core FRLS PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light/ bell/ fan/ exhaust fan/ wall mounted fan/ socket controlled by one 1-way switch, complete all as specified and as directed by Engineer-in-Charge. Note: Cutting chases and making good surfaces shall be included in Schedule "A" Part-I.
Description all as per Serial Item No. 24 here-in-before but with 1.5Sqmm copper conductor cable and 1.5Sqmm cable as earth continuity conductor for 5/6 Amp switch socket point controlled by one way switch on same board complete all as specified and as directed by Engineer-in-Charge.
Description all as per Serial Item No. 24 here-in-before but with 1.5Sqmm copper conductor cable and 1.5Sqmm cable as earth continuity conductor for 5/6 Amp switch socket point controlled by one way switch on independent board complete all as specified and as directed by Engineer-in-Charge.
Description all as per Serial Item No. 24 here-in-before but with 4.0Sqmm copper conductor cable and 4.0Sqmm cable as earth continuity conductor for 15/16 Amp switch socket point controlled by one way switch on independent board complete all as specified and as directed by Engineer-in-Charge.
S & F Energy Saving, environment friendly high bay LED light luminaries of 150 Watt including fittings and hanging arrangement/ fixing arrangement for fixing of light fitting as indicated by channels, clamps, nuts & bolts etc. complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosure for DB MCCB as incomer when MCBs to be used TPN 8 way with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc. and making good of disturbed surface to match with existing colour of wall ,to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires; complete all as specified and as directed. Note : MCCB shall be measured and paid separately.
S&F sheet metal enclosure for DB MCCB as incomer when MCBs to be used TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc. and making good of disturbed surface to match with existing colour of wall ,to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires; complete all as specified and as directed. Note : MCCB shall be measured and paid separately
S&F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc. and making good of disturbed surface to match with existing colour of wall ,to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires; complete all as specified and as directed.
S&F sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc. and making good of disturbed surface to match with existing colour of wall ,to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires; complete all as specified and as directed.
S & F MCB triple pole and neutral rated capacity of 40 Amp, 415 V breaking capacity 10 KA with suitable connected lugs, complete all as specified and as directed.
S & F MCB triple pole and neutral rated capacity of 63 Amp, 415 V breaking capacity 10 KA with suitable connected lugs, complete all as specified and as directed.
S & F MCB single pole and neutral rated capacity of 40 Amp, 240 V breaking capacity 10 KA with suitable connected lugs, complete all as specified and as directed.
S & F MCB triple pole rated capacity of 63Amp, 240 V breaking capacity 10 KA with suitable connected lugs, complete all as specified and as directed.
S & F MCB triple pole rated capacity of 40 Amp, 415 V breaking capacity 10 KA with suitable connected lugs, complete all as specified and as directed.
S & F MCB single pole rated capacity of 5 to 32 Amp, 240 V breaking capacity 10 KA with suitable connected lugs, complete all as specified and as directed.
S&F Metal clad socket with 20A, 240V Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB including removal of old unserviceable one complete all as specified and as directed.
Supply and fix 16/20 Amps industrial panel mounted plug socket for rating 3P+N+E including all accessories complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with RCC 1:2:4 type B1 40mm thick cover slab with 8mm dia TMT bars @150mm c/c in both ways, suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 15mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing after completion, complete all as specified and as directed by Engineer-in-Charge. Note: Earth wire will be measured up to & including 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under this item.
Supply and fix heavy duty exhaust fan, steel body AC single Phase. 230V of size 600mm sweep with, blades, and frame and louvers with and including all accessories, complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with RCC 1:2:4 type B1 40mm thick cover slab with 8mm dia TMT bars @150mm c/c in both ways, suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 40mm bore GI pipe medium grade for protection of galvanised iron strip 32×6mm, including testing after completion and complete all as specified and as directed by Engineer-in-Charge. Note: Earth wire will be measured up to & including 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under this item.
M&L earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point complete all as specified and indicated including testing on completion. Note: Earth wire will be measured up to & including 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under this item.
M&L for bracket for street light fitting made out of 50mm bore pipe medium grade GI tube bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer; complete all as specified and directed.
Supply and fixing multi core PVC insulated multi stranded copper conductor of size 1.5 Sqmm 3 core cable to be connected with street light fittings to loop-in out boxes with its end point terminal connection complete all as specified and directed.
S&F loop-in-loop out FRP junction box of size 4"x8" made out of 3mm thick FRP sheet and locking screw along with 10A rated connectors 04 Pole 01 No including 01 No. 10A MCB SP to control the lamp and duly fixed to the tubular pole/GI pole of post top lantern with suitable clamp at suitable height complete with necessary glands and lugs all as directed.
Supply and fix hot dip galvanised perforated cable tray of width and 75X50 mm and 2mm thick complete with mounting accessories; complete all specified and directed.
Supply, installing, testing and commissioning of LT panel board factory made cubical indoor type (CPRI approved), fabricated out of 3.15mm thick MS sheet, board floor mounted, dust and vermin proof, suitable for voltage 415V 3 phase 4 wire weather proof, double door type with separate hinge door for each compartment with locking arrangement with back door common openable (screwed), grouted in PCC 1:2:4 complete including painting with two coats of synthetic enamel paint over a coat of red oxide primer and including 200A, aluminium busbar (TPN) suitable double compression aluminium cable glands, with the following accessories :- Incoming- (a) MCCB 250 Amp 4 Pole 36kA 415 Volts- 01 No Outgoing- (b) MCCB 100 Amps 4 pole 25kA 415 volts - 01 No (c) MCB 63 Amps 4 pole 10kA 415 volts - 04 No (d) MCB 32 Amps TPN 10kA- 01 Nos (f) MCB 16 Amps DP- 01 No (g) Aluminium busbar 200 Amps (set of four) - 01 set (h) Digital Ammeter- 01 No (j) Digital Voltmeter- 01 No (k) LED indicator lamp (R-Y-B) 01 No set of three
Supply, installation, testing and commissioning 250 AMPS MCCB 4 pole 36 kA 415 Volts in Existing Panel including all cutting and jointing, painting after fixing MCCB as matching with existing LT panel; complete all as specified and directed.
Supply, lay in trenches, ducts, jetty gallery connect, test and commissioning Ductile Iron pressure pipe of size 150mm dia with flanged and confirming to IS-8329 : 2000 in standard maximum lengths, class K-9, flange rating PN-10, fixing with necessary gasket and special items/fittings pipes lining inside with cement mortar (CML) outside with bituminous coating as per Annx `C' of IS-8329, complete all as specified and as directed by Engineer-in-Charge.
Supply, lay in trenches, ducts, connect, test and commissioning Ductile Iron pressure pipe of size 100mm dia with flanged and conforming to IS-8329 : 2000 in standard maximum lengths, class K-9, flange rating PN-10, fixing with necessary gasket and special items/fittings pipes lining inside with cement mortar (CML) outside with bituminous coating as per Annx `C' of IS-8329, complete all as specified and as directed by Engineer-in-Charge.
Supply only DI special like Elbows, Bends of double flanged for connecting upto 150mm dia pipe complete all as specified and as directed by Engineer-in-charge.
Supply only Nitrite gasket of 6mm thick for connecting upto 100/150mm dia DI pipe fittings and Valve with cadmium coated nut and bolts complete all as specified and as directed by Engineer-in-charge.
All as per item no 55 but for 80 mm dia.
M&L for Valve chamber of size 1500mm x 1500mm x 1200mm internal dimensions, with and including excavation in any type of soil, spreading, levelling and refilling etc. PCC (1:4:8) type D2 for foundation, Fly ash brick work of one brick thick wall in CM (1:4) including internal plaster 15mm thick in CM (1:4) external plaster 15mm thick(1:4) upto 150mm below GL and providing coping in PCC (1;2:4) type B1, angular iron frame of size 50x50x6mm with 6mm thick MS plate cover complete including locking arrangements and having FRP coating of 2mm thick on both inside and outside surfaces all as shown in TD drawing and complete all as specified and as directed by Engineer-in-Charge.
M&L for MS framed work in angle or other sections cut to length, bent to shape required drilling, welding including required size nut and bolts, complete all as specified and as directed.
M&L for fabrication and erection of fire stand of suitable size made out of angle iron/channel and painting with two coats of post office red colour synthetic enamel paint over a coat of red oxide primer and lettering with white paint including galvanised MS fire bucket- 04 Nos, 5 litre capacity, complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning of 150mm dia 2 way fire brigade inlets with isolation valve with instantaneous SS coupling 63mm dia with required fittings complete all as specified and as directed by Engineer-in-charge fire brigade inlet branch pipe gun metal 63mm instantaneous inlet, made threaded outlet,15mm bore nozzle short complete all as specified and as directed by Engineer-in-charge.
M&L for fire escape route map drawn on glow sign / flex in required colour and arrows at every 3 metres with proper fixing including accessories, complete all as specified and as directed. (Rate are for upto (G+4) blocks).
S&F electrical type dual tone Siren with 2.0 km range with activation buttons at distance not more than 150 Mtrs including wiring and starter complete all as specified and directed by Engr-in-charge.
Supply, installation, testing and commissioning of non-pyro based clean agent/aerosol fire suppression extinguisher system with ILP valve and 24 vdc solenoid valve/QBD with pressure gauge on wall/roof inside LT/HT rooms with necessary mounting brackets, hose pipes, pressure gauge and as per OEM recommendations of capacity 10 Kg, complete all as specified and as directed by Engineer-in-charge.(Job includes integration of the extinguishers along with fire alarm control panel with necessary wiring and relay modules).
S&F of addressable intrinsically safe dual action manual call point with IP67 rating. The addressable polycarbonate pull station is dual action and features translucent plastic at the centre, allowing visibility of an internal LED that indicates alarm condition and polling status. The unit is addressable using a DIP switch protected within the pull station. The polycarbonate pull station may be flush mounted on a single gang work box or use an optional back cover; complete all as specified and as directed by Engineer-in-charge.
S & F of intrinsically safe multi sensor-heat cum smoke detector with base led for 360°visibility, Sleek low-profile housing design. Regular 100mm base. IP Rating: IP-42.Low profile design EN54-5:2000 Class AIR:(Amendment 1) CEA4021 ,comprises optical smoke and thermistor temperature which give both a combined signal as well as a separate heat signal for improved false along isolator modules as required, complete all as specified and as directed.
S & F of addressable type loop open area sounder visual indicator makes full fuse of the protocol and has been designed for use indoor and open areas, complete all as specified and as directed.
S & F of 2 core 1.5 sq mm copper FRLS armoured cable through 25 mm ERW conduit pipe and conduit size as per cable requirement 2 core 1.5 sqmm, multi stranded (24/0.2), high conductivity annealed bare electrolytic copper conductor 650/1100v grade, armoured, both inner and outer FRLS PVC sheathed with proper pair identification 1.2 Standard: As per IS1554, Part-I & IS 5831 latest and any other relevant standard, complete all as specified and as directed.
Supply and fixing of addressable type horn/storbe with or without Xenon flasher in ABS, output 86 db current 450 mA, complete all as specified and as directed.
Supply and fixing AFFF type fire extinguisher - mechanical foam type 9 litres capacity complete with initial charge, gun metal cap, discharge hose with nozzle, wall fixing brackets, etc., complete all as specified and as directed by Engineer-in-Charge.
Supply and fix light weight screw grip type CO2 fire extinguishers - 4.5 Kg capacity complete with initial charge, gun metal cap, discharge hose with AB horn, nozzle, wall fixing brackets etc. confirming to IS : 15683 with ISI mark complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Dry chemical powder stored pressure type - 9 Kg capacity complete with initial charge, fund metal cap, discharge hose with nozzle wall fixing brackets etc. confirming to IS:15683 with ISI mark complete all as specified and as directed by Engineer-in-Charge.
Supply and fix water type extinguisher of capacity 9 Kg complete with initial charge gun metal cap, discharge hose with nozzle, wall fixing brackets, including all accessories. Confirming to IS : 15683 with ISI mark. Complete all as specified and as directed by Engr-in-Charge.
Supply, install and testing of automatic modular dry chemical powder based fire extinguisher on wall/roof inside transformer room with necessary mounting brackets, including all accessories as required and as per OEM recommendations of capacity 10 Kg suitable for 7-8 sq mtr area protection, operation time 15-20 seconds and complete all as specified and as directed by Engr-in-Charge.
Material and labour for flame proof point wiring with 1.5 sq mm (nominal area) PVC insulated unsheathed FRLS cable with copper conductor, single core multi stranded 1100 V graded confirming to IS 694 : 1977 drawn in concealed/surface stove enameled steel conduit of size 20 mm dia with all accessories like solid elbows, saddles etc including 20 mm metallic flexible pipe at the connecting point where necessary and 1.5 sqmm one single core PVC unsheathed FRLS cable with multi stranded copper conductor as earth continuity conductor and connected to common earth dolly as specified and directed by Engr-in-Charge.
Design, Fabricate, supply, errect, testing and commissioning of 25/10 Ton capacity EOT crane push button and radio remote control system complete with span of 15 Mtrs (approx.), long travel 15 Mtr and lift hook 9 mtr from floor including supply, laying of crane track rail of suitable cross section on existing gantry girder and painting the girder include supply the girder including auxiliary hoist, three phase, electrically operated overhead travelling crane(EOT) with connected accessories like rope drum, steel wire rope, sheaves, pulley, hydraulic thruster brake, single phase preventer, overload relay, SFU, air brake contactor, main hoist motor, micro hoist motor, cross travel motor, long travel motor, lifting hook, service platform, way with railing, ladders, buffers, provision safety siren for over load, safety hooks/clamps, on wall for operation and maintenance of track and DSL system including all accessories etc. Complete all as specified and as directed by the Engineer-in-charge include following: (a) Design, supply ,install, test and commissioning DSL system with PVC shrouded copper bus bar for 3 phase and neutral including earth bus system all as specified suitable for 25/10 TON EOT crane. (b) Supply of tools as per the list of OEM specifications. (c) Supply of spares for two years operation and normal maintenance as per the list of OEM specifications.
Serial Item No. 76.00 (Contd....) (d) Provision for LT power cable of suitable size from the panel board to crane. (e) Provision of additional push button system with interlocking wiring etc. Complete as per OEM specification. (a) Capacity of crane -25/10 Ton Double girder (b) Span-15.0 Mtrs (c) Bay length-54.0 Mtrs (d) Hook height-9.0 Mtrs (e) speed:- (i) Main host speed- 3Mtr/min (ii) Long travel speed - 15 Mtr/min (iii) Cross travel speed - 10 Mtr/min Note:- (a) All the crane/hoists are including gantry rails of suitable size DSL system with PVC shrouded copper bus bar etc. complete. (b) All micro speed will be 1/10 of main speed all motions. (c) Audio visual alarm to provide to all motions, single phase preventer, over load relay, safety siren/overload alarm. (d) All cranes & hoist shall confirm to IS 807 & IS 3177. (e) The bidder have to visit the site before quoting the tender please.
Supply and install voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 V with output voltage stabilised at 230 V with accuracy of + 2.5% and of capacity 5 KVA including all accessories complete all as specified and as directed by Engineer-in-Charge.
Supply and install voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 V with output voltage stabilised at 230 V with accuracy of + 2.5% and of capacity 1 KVA including all accessories complete all as specified and as directed by Engineer-in-Charge.
Supply & fix in repair switch flame proof rotary type with termination box in LM6, 6A, single pole 230V complete all as specified and as directed by Engr-in-Charge
Supply and fix in repair Flame proof weather proof LED light fitting suitable for 35 Watt 230V all as specified and directed by Engr-in-Charge
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine with and including HDPE pipe of 100mm dia suitable for 6 KGF/Sq.cm working pressure, complete all as specified and as directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine with and including HDPE pipe of 80mm dia suitable for 6 KGF/Sq.cm working pressure, complete all as specified and as directed.
Supply and fixing of flame proof ceiling fan, AC single phase 230/240 V of size 1200mm sweep complete all as specified and directed by Engr-in-Charge
Supply and fix flame proof MCB DB single door type SPN 4 ways complete all as specified and directed by Engr-in-Charge
Supply and fixing of 415V 50 Hz 4P MCCB of 100A, 25 KA complete all as specified and directed by Engr-in-Charge
Supply and fixing of 415V 50 Hz MCCB 4P of 63A,25 KA capacity complete all as specified and directed by Engr-in-Charge
SRI SURYA PROJECTS (BID ID -3405120)
S V S ENTERPRISES (BID ID -3397694)
B DURGA REDDY INFRASTRUCTURES PRIVATE LIMITED (BID ID -3405501)
ANANDA PROFIES PRIVATE LIMITED (BID ID -3405255)
M/s Imperial Coastal Infra (BID ID -3397359)
VENKATA SAI SRINIVASA CONSTRUCTIONS PRIVATE LIMITED (BID ID -3405274)
jd constructions (BID ID -3397668)
vijay infraprojects pvt ltd (BID ID -3405322)
PMR CONSTRUCTIONS (BID ID -3405368)
anjaliinfratech (BID ID -3405140)
DES RAJ AND SONS BUILDERS PVT LTD (BID ID -3405581)
CHHABINDRA KUMAR PRADHAN (BID ID -3405175)
Komal Buildcon Pvt. Ltd. (BID ID -3405694)
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid