Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.3 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹7.1 L+₹2.8 L (64.8%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | Rejected-Technical | - | Rejected-Technical Non Responsive |
Tender Value
₹8.8 L
EMD Value
₹17,600
Closing Date
10 Nov 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
KDA KOTA
Operation, Maintenance and Security of Lights at Kishor Sagar Talab and Jag Mandir
2026_UITKo_604872_1
23/2026-27 (41)
Open Tender
Electrical Works
Percentage
365 days
KOTA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Online Through SSO Portal
₹17,600
Yes
18 Nov 2026
30 Oct 2026
12 Nov 2026
30 Oct 2026
10 Nov 2026
30 Oct 2026
90 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Operation, Maintenance and Security of All Typee Of LED Street Light System With Fixtures and Perform Following Work.(i)Maintain power supply (underground and overhead) from kedl/jvvnl energy meter to auto on off pannel to feeder piller to pcc/tubular pole to led light.(ii)Repair , Rectification, Replacement of defective component of the Existing Led light or entire led light if required so to run led light system.(iii)Replacement of old led light with new led light if led found broken/damage/stolen.(iv)Replacement of damage or burnt cable/overhead line/fuse box with new cable/overhead line/fuse box from from kedl/jvvnl energy meter to auto on off pannel to feeder piller to pcc/tubular pole junction in supervision of engineer for this work payment shall be extra.(v)Repair of damage cable and overhead line from kedl/jvvnl energy meter to auto on off pannel to feeder piller to pcc/tubular pole.(vi)Replacement and repair of damage /burnt /stolen cable , wire or jumper from junction box to light and pcc pole to light .(vii)Operation maintenance and security of auto on off pannel installed by contractor as well as exist old pannel . If any part of pannel found defective/burnt/ stolen/damage contractor have to replace it with new parts and run the led system properly( 314 kda led* 12 month =3768 Nos.+ Future proposed lights 25 Nos.*12 Months= 300 Nos. ) | 4,068 | Nos | 53 | ₹2,15,604 |
| 2 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - |
| 3 | 4 core*10 sqmm | 350 | mtr. | 192 | ₹67,200 |
| 4 | 3.5 core*25 sqm | 100 | mtr. | 256 | ₹25,600 |
| 5 | Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | - | - | - | - |
| 6 | 125 mm X 200 mm X 122 mm | 30 | EACH | 1,827 | ₹54,810 |
| 7 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | - | - | - | - |
| 8 | 50 mm | 350 | mtr. | 85 | ₹29,750 |
| 9 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - |
| 10 | Single pole MCB (With B/C curve tripping Characteristics) | - | - | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.51 MB
CONDITION_E_23_41.pdf
Tender Documents • 0.35 MB
BOQ_1072717.xls
BOQ • 0.41 MB
Corrigendum_NIT23.pdf
PDF • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .