Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.7 L+₹62,906.64 (1.96%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹33.1 L+₹1.1 L (3.37%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹33.8 L+₹1.8 L (5.64%)Rejected-AOC 3RD FLOOR STAR ENCLAVE GNB ROAD PAN BAZAR GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | L4 | Rejected-AOC L4 | |
| 5 | L5₹34.4 L+₹2.4 L (7.48%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
27 Aug 2021, 6:00 pmClosed
CWE AF Borjhar
Commander Works Engineers AF Military Engineer Services Borjhar PO Borjhar Airport Guwahati-15 Assam Pin 781015 Tele 0361 2841626
SPECIAL REPAIR RENOVATION OF KVS STAFF QUATERS AT AFS KUMBHIRGRAM
2021_MES_463309_1
CWE(AF)/KUM/TOKEN-25 OF 2021-22
Open Tender
Construction Works
Item Rate
180 days
Kumbhirgram
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I AF Kumbhirgram
₹86,000
Yes
11 Sept 2021
28 Jul 2021
30 Aug 2021
28 Jul 2021
27 Aug 2021
13 Aug 2021
Amount
B/R Works:- Preparation of old decorated plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying one coat of oil emulsion distemper complete all as specified and directed.
Preparation of old decorated plastered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying two coats of white wash complete all as specified and directed.
Preparation of old decorated plastered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying one coat of oil emulsion distemper complete all as specified and directed.
Preparation of old decorated plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying one coat of dark weather coat paint (Exterior grade 1st quality) complete all as specified and directed.
Preparation by removing of old paint on steel roof surfaces with paint remover or by burning off with blow lamps, cleaning by steel wire brushing ,sand paper and brooming down any Nos of coats , surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L 50mm thick plain cement concrete (1:3:6) type C1 using 20mm graded crushed stone aggregate as in plinth protection, finishing surfaces even and smooth without using extra cement, concrete laid in alternate bays with 6mm wide joints through out thickness of concrete along the wall & between bays, joints filled with mastic filling using one part of bitumen 80/100 mixed with three parts of dry sand complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of cement base paint complete all as specified and directed .
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil emulsion distemper (interior grade) over and including one coat of cement primer and 1mm thick wall care putty on wall complete all as specified and directed .
M&L for rendering 15 mm thick (10+5mm) in two layers with cement mortar (1:6) on fair faces of brick work or concrete surfaces is to be finished even and smooth (without using extra lime or cement) mixing with WPC @ 2 % weight of cement or as per direction of manufacturer complete all as specified and directed. Note: WPC shall be mixed in 5mm thick 2nd layer only and supply only WPC shall be measured and paid separately under respective item.
Taking down existing roof treatment such as tarfelt with tiles and cement /lime mortar and screed bed from roof surfaces including parapets and lowering and removing the same to a distance exc. 50 m and n. exc. 100m including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane, finished even and smooth without using extra cement including mixing of WPC as per manufacturer's instruction complete all as specified and directed. (NOTE : Polymeric membrane and supply only WPC shall be measured and paid separately under relevant item ).
M&L for PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in roof kerbs, slightly rounded or chamfered on edges, mixed with water proofing compound as per manufacturer's instructions, finished even and smooth on exposed concrete surface without using extra cement complete all as specified and directed. (Note: Water proofing compound shall be measured and paid separately under relevant item as supply only).
Supply only integral water proofing compound conforming to IS:2645-1975, complete all as specified and directed.
M&L Water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment:- (a) Applying bitumenous primer @ 0.25 ltrs per Sqm over plastered surfaces of roof including parapet surface. (Note :- Bituminuous primer shall be "TANK MASTIC" manufactured by "EMUFALTE" manufactured by M/s Texsa India Ltd./STP) (b) Over the priming coat laying one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick weight not less than 3.50 Kgs per Sqm reinforced with non woven polyester febric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note :- (i) Laying APP based polymeric membrane shall be done with torch application method or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints with suitable adhesive as per manufacturer's instruction. (iii) APP based polymeric membrane shall be "MOPLY FP 3MM" manufactured by M/S Texsa India Limited and Super Thermolay by STP Ltd. (iv) Applying two coats of Aluminium paint over APP membrane.
Demolition of plain cement concrete (Un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) including removal of spoils/ demolished materials to a distance not exceeding 100m and depositing complete all as specified and directed.
E/M WORKS(INTERNAL) Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, complete all as directed.
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store(to be measured only when found serviceable in all respects complete for reuse), complete all as directed.
Materials and labour for concealed point wiring with 1.50 sq.mm. FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade, single core, drawn through and including PVC conduit 20 mm dia(medium grade) complete with all fittings and accessories, fixed to walls/ceiling, including factory made sunk type mild steel terminal boxes 1.25 mm thick (wall thickness) conforming to IS-5133 (Part-I) with 3mm thick hylem sheet top cover for mounting switches/ sockets/regulator etc., including 1.50 sq.mm FRLS PVC insulated, unsheathed multistranded copper conductor cable 1100 Volts grade, single core, green in colour for earth continuity conductor connected to common earth dolly for One light point/ One fan point/bell point controlled by one switch including cutting chases for concealed conduit, pinning in, making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.
All as per item No 28 here-in before but for one 3 pin, 5 Amp switch socket outlet point on independent board complete all as specified and directed.
All as per item No 28 here-in before but for one 3/5 pin, 16 Amp switch socket outlet on independent board with 2.5 sqmm PVC insulated unsheathed multistranded FRLS copper conductor cable, complete all as specified and directed.
S&F LED tube light fittings , 18/20 W four feet, with high quality extruded polycarbonate housing & integrated LED driver with decorative end caps with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Replacement of old existing compact fluorescent lamp and providing LED lamp 9 watt suitable for B22 type holder, complete all as specified and directed.
Supply and fix batten angle lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Replacement of old existing conventional bulkhead light and providing 10 W LED Bulkhead luminaire with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F LED surface mounted square slim and elegant downlight fittings, 15 W , with high aesthetic appeal for soothing light & integrated LED driver with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F switch piano flush type single pole one way 5 amps, 230 V complete all as specified and directed.
Fixing only switch piano flush type single pole one way 5 amps complete all as specified and directed. (Note:Serviceable switch piano flush type obtained from taking down of point wiring shall be reused).
S & F switch socket combination 2 in1, 5 pin 5 Amp flush type complete all as specified and directed.
S & F switch socket combination 2 in1, 3 pin 5 and 15 Amp flush type complete all as specified and directed.
Fixing only switch socket combination 2 in1, 5 pin 5 Amp flush type complete all as specified and directed. (Note:Serviceable switch piano flush type obtained from taking down of point wiring shall be reused).
Fixing only switch socket combination 2 in1, 5 pin 5/15 Amp flush type complete all as specified and directed. (Note:Serviceable switch piano flush type obtained from taking down of point wiring shall be reused).
S&F ceiling rose, surface bakelite three terminals, PVC/polycarbonate, isolated body complete all as specified & directed.
Fixing only ceiling rose, surface bakelite complete all as specified and directed. (Note:Serviceable ceiling rose obtained from taking down of point wiring shall be reused).
S&F stepped type electronic fan regulator flush type AC, 230V complete all as specified and directed.
M&L for sub main wiring with 2 runs of single core 10.0 sqmm (Nominal area) multi stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through and including concealed PVC conduit 25mm dia medium grade ISI marked with fittings and accessories including 1 x 6.0 sqmm, single core (Nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly, including cutting chases for concealed conduit, pinning in, making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.(Note: Two runs of 10.0 sqmm cable and one run of 6.0 sqmm earth continuity conductor including PVC conduit with plastic terminal boxes shall be measured as one run length).
M&L for sub main wiring with 2 runs of single core 6.0 sqmm (Nominal area) multi stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through and including concealed PVC conduit 25mm dia medium grade ISI marked with fittings and accessories including 1 x 6.0 sqmm single core (Nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly, including cutting chases for concealed conduit, pinning in, making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.(Note: Two runs of 10.0 sqmm cable and one run of 6.0 sqmm earth continuity conductor including PVC conduit with plastic terminal boxes shall be measured as one run length).
M&L for sub main wiring with 2 runs of single core 4.0 sqmm (Nominal area) multi stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through and including concealed PVC conduit 25mm dia medium grade ISI marked with fittings and accessories including 1 x 4.0 sqmm single core (Nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly, including cutting chases for concealed conduit, pinning in, making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.(Note: Two runs of 10.0 sqmm cable and one run of 6.0 sqmm earth continuity conductor including PVC conduit with plastic terminal boxes shall be measured as one run length).
S&F sheet metal enclosure MCB DB , SPN 8 way, double door with 200 Amp rated bus bar with earth and neutral link ,complete with fixing accessories flush mounting to wall including cutting chases for concealed DB and making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.
S&F sheet metal enclosure MCB DB , SPN 4 way, double door with 200 Amp rated bus bar with earth and neutral link ,complete with fixing accessories flush mounting to wall including cutting chases for concealed DB and making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.
S&F miniature circuit breaker (MCBs) double pole, 240 Volt, 40 Amps, "C" series,10 KA breaking capacity, complete all as specified and directed.
S&F MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps complete all as specified and directed.
S&Fsheet metal enclosures with socket plug top and miniature circuit breaker (MCBs) single pole , 240 Volt, 20 Amps, "C" series,10 KA breaking capacity, complete all as specified and directed.
E/M WORKS(EXTERNAL) S&F sheet metal enclosure for MCCB DB , TPN 4 way, double door with 250 Amp copper bus bar for each phase with 2 Neutral bar, 2 Earth bar and cable ties for cable management, with provision for 250 / 160 MCCB 4 pole as incomer and DP/TP MCB's as out going and blanking plate covering blank position,complete with fixing accessories flush mounting to wall including cutting chases for concealed DB and making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.
S&F MCCB 4 Pole of capacity 250 Amps, adjustable type, 415V, breaking capacity 36 KA complete all as specified and directed.
S&F MCCB 4 Pole of capacity 160 Amps, adjustable type, 415V, breaking capacity 36 KA complete all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured heavy duty underground electric cable aluminium conductor 1100 volt grade of cross sectional area 25 sqmm 4 core, connecting to LT panels, main switch with suitable size aluminium lugs, including cliping or fixing on wall or ceiling with suitable clamp, nut, bolts or laying in trenches/ ducts etc.and including taking down old existing unserviceable cable complete all as specified & directed. Note: Excavation, earth work, sand cushioning and covers shall be measured and paid separately.
Supply, laying, jointing and testing of XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured heavy duty underground electric cable aluminium conductor 1100 volt grade of cross sectional area 16 sqmm 4 core, connecting to LT panels, main switch with suitable size aluminium lugs, including cliping or fixing on wall or ceiling with suitable clamp, nut, bolts or laying in trenches/ ducts etc.and including taking down old existing unserviceable cable complete all as specified & directed. Note: Excavation, earth work, sand cushioning and covers shall be measured and paid separately.
Supply, laying, jointing and testing of XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured heavy duty underground electric cable aluminium conductor 1100 volt grade of cross sectional area 10 sqmm 4 core, connecting to LT panels, main switch with suitable size aluminium lugs, including cliping or fixing on wall or ceiling with suitable clamp, nut, bolts or laying in trenches/ ducts etc.and including taking down old existing unserviceable cable complete all as specified & directed. Note: Excavation, earth work, sand cushioning and covers shall be measured and paid separately.
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft / loose soil complete all as specified and directed
Returning, filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc 50.00 mtr and depositing where directed at a level not exc 1.50 mtr above the starting point , complete all as specified and as directed.
Supply and spreading dry sand of approved quality for cushioning of UG cable laid in trenches 8 cm deep before laying the cable and 15 cm thick after laying & streching the cable complete all as specified and directed. (NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid for).
Supply and laying in trenches dry well burnt locally available best quality sub class “B” bricks of size 230x115x75mm over sand cushioning for protection of cable complete all as per specified and directed.
Supply and laying/fixing GI pipe light grade 50 mm bore for cable protection including all fittings laid in trenches or fixed on pole with suitable clamps complete all as specified and directed.
Taking down street light fittings any type and watt including accessories from 8.5/9 mtr pole and top of building or other similar situation complete all as specified and directed.
Supply, fix and testing LED street light fitting made up of pressure die cast aluminium housing, top maintainable type with toughened glass cover in IP 66 protection, 45W suitable for pole dia 40mm including fabrication of existing bracket complete all as specified and directed.
S&F polycarbonate PVC junction box/ bus bar chamber for loop connection of street light cable of size 205x255x112mm with 5 pole terminals with provision for cable entry and exit and making holes on steel pole where required, fixed on pole steel/PCC with suitable two flat iron clamp made out of 25x4mm and GI nut bolts complete all as specified and directed.
S&F in replacement PVC insulated and sheathed stranded round copper conductor 1.5 sqmm , 3 core for street light connection from light fitting to terminal box including all fixing arrangement, complete all as specified and directed.
Taking down unserviceable post top lantern/ graden light fittings any type and watt including accessories from post/gate wall complete all as specified and directed.
Supply and fix LED 35 W post top lantern made up of cast aluminium spigot housing with decorative clear acrylic diffuser and IP65 protection, suitable for existing pole complete all as specified and directed.
M&L for PCC, 1:3:6, Type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete for pole complete all as specified and directed.
S&F digital time switch two module operated on 110-240 volts, AC 50 Hz, Din rail mounting single channel,including taking down existing unserviceable time switch complete all as specified and directed. Make: L&T Cat No: AUTS02DIG00 or equivalent of Make : Legrand/Indoasian.
S&F power contactor 3 pole, 50 Amps capacity panel mounting with entry terminals, including taking down existing unserviceable power contactor complete all as specified and directed. Make: L&T Cat No: CS97075 or its equivalent of Make : Legrand/Indoasian.
Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below normal ground level, with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth lead wire 4.0 mm dia , by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 15mm bore from earthing test point or main controling switch as directed including providing funnel with 20mm bore GI watering pipe medium grade, wire mesh,charcoal or coke andcommon salt in alternative layer of 15 Cm (compacted thickness) all round the earth electrode,concrete earth pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 50mm thick cover of RCC (1:2:4) (re-inforced with 8mm dia TMT bar @15 cm C/C bothways and MS bar handle made of 10mm dia bar) including necessary earth work in excavation,returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 3 of MES Schedule Part-I including testing on completion complete all as specified and directed.
M/S PIJUSH BHATTACHARJEE
M/S P K ROY AND SONS
saitraders
Niranjan Roy
M.S. Construction
M/s Nishi Kumar Das
M/s J. C. CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .