Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC JANAKI NIVAS BEHIND CHOVVA TEMPLE CHOVVA PO KANNUR KERALA 670006 | KANNUR | KANNUR | KERALA | 670006 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹8.8 L+₹92,892 (11.8%)Rejected-AOC 121004 | L2 | Rejected-AOC being L2 | |
| 3 | L3₹9.3 L+₹1.4 L (18.3%)Rejected-AOC | L3 | Rejected-AOC being L3 | |
| 4 | L4₹9.6 L+₹1.7 L (21.7%)Rejected-AOC | L4 | Rejected-AOC being L4 | |
| 5 | L5₹9.6 L+₹1.7 L (22.1%)Rejected-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L5 | Rejected-AOC being L5 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
7 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Cannanore
AGE I Cannanore HQ Hospital kannur PO 670017
Repairs/maintenance to external electric supply and connected works of OTM and Md Accn area DSC Centre at Kannur under AGE (I) CANNANORE.
2022_MES_561227_1
8233
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Cannanore
Class E Category b( i )
8 documents required · 8 mandatory
₹500
Yes
AGE I Cannanore
₹16,000
Yes
4 Feb 2023
3 Nov 2022
12 Dec 2022
4 Nov 2022
7 Dec 2022
17 Nov 2022
4 Nov 2022 - 10 Nov 2022
Amount
Excavating in trenches n.exc. 1.5m wide and n exc 1.5m in depth for laying of LT UG cable, pipe, pole, stay etc and n exc 10sqm on plan and getting out in hard/dense soil all as specified and directed.
Excavating in trenches n.exc. 1.5m wide and exc 1.5m and n.exc. 3m in depth for laying of LT UG cable, pipe, pole, stay etc and n exc 10sqm on plan and getting out in soft disintegerated rock all as specified and directed.
Returning and filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick with soil obtained from excavation all as directed
Removing excavated materials to a distance n exceeding 50m and depositing where directed at a level 1.5m above starting point all as specified and directed.
Supply and spreading in natuaral riddled soil as earth cushioning to cable by using IS sieve to separate the composite particle/roots etc 8cm thick before laying the cable and 15cm thick after laying , stretching and testing of cable and compacted in layers to form a solid bed covering to cable all as specified and directed.
Supply and laying in trenches burnt brick sub class B of locally available size 20x9x6cms for protection of UG cable laid flat and dry over the cable , perpendicular to the direction of cable all as specified and directed.
Laying only in trenches burnt brick sub class B obtained from item 1 here in before for protection of UG cable laid flat and dry over the cable , perpendicular to the direction of cable all as specified and directed.
M&L for GI tubing, 50mm bore light grade, galvanized, with all fittings required such as bends, Tees, elbows, sockets, fixing clamps FI 25x4mm with nut, bolt and washer alongwith pole for protection of cable/GI strip including removing old unserviceable pipe any size all as directed.
All as per item No 8 here in before but 80mm bore pipe including removing old unserviceable pipe any size all as directed.
Taking out old unserviceable LT UG cable, Supply and lay including fixing and connecting electrically XLPE insulated LT underground cable, armoured heavy duty electric cable with aluminum conductor multi-stranded 1100 volts grade, laid in trench, fixed on wall/pole drawn through pipe etc including provision of lugs & testing of following sizes complete all as specified and directed. (a) 2 core 10 sqmm
All as per item No 10 here in before but 4 core 16 sqmm all as specified and directed.
All as per item No 10 here in before but 3.5 core 35 sqmm all as specified and directed.
All as per item No 10 here in before but 3.5 core 95 sqmm all as specified and directed.
All as per item No 10 here in before but 3.5 core 120 sqmm all as specified and directed. Note for item 10 to 14: Excavation shall be measured and paid seperately. Quoted rate include of making connection to LT panel/feeder pillar box/junction box through suitable size aluminium lugs and cable glands.
Cutting the existing hard standing/ bituminous road surfaces for laying cable / GI pipe etc and providing plain cement concrete (1:2:4) ,type B2,using 40 mm graded stone aggregate for filling road cuttings surfaces and making good the disturbed surfaces all as specified and directed. Note : Excavation required below paving/road shall be measured and paid seperately.
Supply and replacing of heavy duty cable PVC insulated aluminium conductor of size 10 sqmm 2 core, 1100 volts, grade as service connections served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm dia GI suspension wire one twin core cable flat or circular stranded conductor complete all as specified and directed.
Supply and fixing MCCB , 4 pole, 100 Amps, microprocesser based , rupturing capacity 16 KA, 415 Volts with adjustable thermal - Magnetic Release in L&T/Scheider/ABB/Havells elctrically connecting up including taking down/removing of U/s MCCB from existing LT panel after disconnecting electric connetion complete all as specified.
Supply and fixing MCCB , 4 pole, 160 Amps, microprocesser based , rupturing capacity 36 KA, 415 Volts with adjustable thermal - Magnetic Release in L&T/Scheider/ABB/Havells elctrically connecting up including taking down/removing of U/s MCCB from existing LT panel after disconnecting electric connetion complete all as specified.
Supply and fixing MCCB , 4 pole, 400 Amps, microprocesser based , rupturing capacity 36 KA, 415 Volts with adjustable thermal - Magnetic Release in L&T/Scheider/ABB/Havells elctrically connecting up including taking down/removing of U/s MCCB from existing LT panel after disconnecting electric connetion complete all as specified.
Supply and fixing MCCB , 4 pole, 200 Amps, microprocesser based , rupturing capacity 36 KA, 415 Volts with adjustable thermal - Magnetic Release in L&T/Scheider/ABB/Havells elctrically connecting up including taking down/removing of U/s MCCB from existing LT panel after disconnecting electric connetion complete all as specified.
Repairing to existing LT panel at site by welding the hinges, replacing of front and back door sheet as required at site, aluminium bus bar, locking arrangement, panel lugs, including disconnection and reconnection of cables with suitable size alum lugs for any size of cable complete all as directed by Engr-in-Charge.
M & L for Painting of concrete pole, by applying one coat of white paint after scraping / brushing and cleaning the Algae on pole and cross arms and a coat of white synthetic enamel painting to pole upto 1.5 mtr from ground level shall be painted by alternate layer of black and white enamel paint ( 30 cms apart) Pole Number shall be written on pole by black paint in yellow circle of 150mm dia. A coat of aluminium painting shall be done on Cross arm and bracing, nut, bolts and washers etc after prep of surfaces all as directed by Engr in charge.
Dismantling old and unserviceable pre stressed concrete /Steel poles any type and height including breaking cement concrete complete, Material and erection of Prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 complete all as specified and directed by engr-in charge. Note - Excavation shall be measured and paid seperately.
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate for concrete as in foundation for pole and stay including use and waste of form work all as specified and directed.
M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for concrete as in pole coping including use and waste of form work all as specified and directed.
Preparation of old treated surfaces by scraping down of LT panel of size 0.9 m x 1.3 m x 0.4m appx complete internal and external and applying spray painting by using spray gun, compressor and stand by DG set of suitable capacity, two coats of synthetic enamel paint of smoke grey colour over one coat of red oxide primer, including writing incoming/out going locations in white colour of suitable font all as directed by Engineer in Charge.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit vertically to a depth of not less than 2.25 m below ground level) with top edge of plate at a depth of not less than 1.5 m below normal ground level, connected to galvanized iron strip of 25 x 4 mm as earth lead and all as directed. by means of bolts, nuts, check nuts and washers of galvanized iron or steel connected to earthing test point, continuous earth lead protected by using GI pipe light grade 40mm bore, 20 mm dia GI pipe medium grade for watering funnel including necessary excavation, earth work in any type of strata, PCC pit and RCC chamber cover complete including test point made out of steel plate of size 75x75x6mm fixed to wallall as specified and as shown in electrical plate No 3 of SSR Part-I including dismantling old unserviceable earthing all as directed. Note :- Rate quoted shall deem to include for GI earth wire and GI pipe lead upto 7.5m length.
Cutting and trimming tree branches of girth n exc 15cm touching to the over head line HT/LT feeder, security light pole, 3m on both sides and removing the fallen branches and dispositing off all as specified and directed. Note : Prior permission from Engineer in charge shall be obtained before trimming. HT/LT line shall be kept clear from tree branches till date of completion of contract.
M&L for Structural steel work in replacement of existing unserviceable Cross arms bracing, supports, clamps and back plates fabricated from steel sections including nuts,bolts ,washers,welding ,bending cold or hot drilling holes for bolts in any shape or size as indicated or directed inclusive one coat of primercoat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Dismantling of defective/perished ACSR conductor over head line from existing pole, service feeder or distribution span all as directed
Material and labour for ACSR conductor weasel (6x2.59+1x2.59 Al+steel) any size drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag ,jointing jumpers,etc complete all as specified and directed
M&L for replacement of shackle type porcelain vitreous, white brown or green insulator for working pressure 1.1 kv of size 100mm height and 115 mm dia including galvanized mild steel straps of section 31 x3 mm size ,12 mm dia bolt nut and washers complete all as specified and directed
M&L for replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1.1 kv complete all as specified and directed
M&L in replacement for Stay assembly with loop type insulator, vitreous porcelain, large size, 90 x 140mm, clearance of hole 25.5 mm complete with accessories as shown in Electrical Plate No 1 of SSR Part-I consisting of stay rod 20 mm dia, stay plate 300 x 300 x 6 mm thick and GI stay strand 7/4mm including necessary fixing clamps, nuts, bolts, etc; complete all as specified and directed.
Neptune Engineers and Builders
JM Engineering
PLATINUM CONSTRUCTIONS
Sreekrupa Enterprises
SAPTHAGIRI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .