Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Qualified |
| 2 | Accepted-Technical | Accepted-Technical Qualified |
| 3 | Accepted-Technical HOUSE NO 3 NEW VINAYA NAGAR DELHI ROAD NEAR MAX HEALTH HOSPITAL ROHTAK HARYANA 124021 | ROHTAK | ROHTAK | HARYANA | 124021 | Accepted-Technical Qualified |
| 4 | Accepted-Technical | Accepted-Technical Qualified |
Tender Value
₹12.0 L
EMD Value
₹23,000
Closing Date
7 Jul 2026, 9:00 amClosed
MANJEET DAHIYA
Municipal Committee Kundli
Supply and Erection of 12.5 mtr high mask light at various location in MC Kundli.
2026_HRY_532416_1
2026F447870E 6316 4940 A8F8 E906EF1C24E11676ULB
Open Tender
Civil Works
Works
90 days
Kundli(MC)
2 documents required · 2 mandatory
₹1,000
Yes
₹23,000
Yes
18 Aug 2026
30 Jun 2026
7 Jul 2026
30 Jun 2026
7 Jul 2026
30 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installation, Testing and Commissioning of Flood Light, powder coated pressure
die cast aluminum body with built in or separate driver as per the requirement with Driver
efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating
temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per
IEC 61000-4- 5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95,
IP- 66,IK-10, CRI )80 , under voltage and over voltage protection, EMI- EMC as per
CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project
requirement deg., suitable tilt able fitting, life time (LED,Driver and electrical circuitary) of
minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per
LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K
/6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5,
Maximum power consumption should not more than the specified rating and Fixture shall
be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS,
PVC insulated copper conductor single core cable and earthing etc. as required with
Minimum 5 year OEM warranty. System lumen efficacy 105 (120 lm/Watt output . LM79
and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall
be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per
requirement. (Thermal management: heat sink of aluminum housing such that LED
junction temperature shall not rise above 90°C). | - | Each | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_611480.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .