Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC STREET NO 10 MALLOMAZRA ROAD BHAKHRA ENCLAVE PATIALA PB | PATIALA | PUNJAB | 140401 | L1 | Accepted-AOC AOC | |
| 2 | L2₹35.6 L+₹6.9 L (24.0%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹35.9 L+₹7.2 L (25.1%)Rejected-Finance | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹36.2 L+₹7.5 L (26.3%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹36.3 L+₹7.7 L (26.7%)Rejected-Finance | L5 | Rejected-Finance Rejected being |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
14 Sept 2023, 6:00 pmClosed
GE (N) AMBALA CANTT
GE (N) AMBALA CANTT
CA NO GE(N)AMB-40/2023-24 PROVISION OF 272 X GEYSERS, 110 X CEILING FANS, 15 X AIR CIRCULATOR FANS AND THEIR CONNECTED WORKS IN THE AREA OF AGE E/M UNDER GE (N) AMBALA CANTT
2023_MES_614014_1
GE(N)/AMB-40/2023-24
Open Tender
Civil Works
Item Rate
120 days
GE (N) AMBALA CANTT
As per tender documents
9 documents required · 9 mandatory
₹500
GE (N) AMBALA CANTT
₹99,000
Yes
14 Oct 2023
17 Aug 2023
16 Sept 2023
17 Aug 2023
14 Sept 2023
2 Sept 2023
17 Aug 2023 - 2 Sept 2023
Amount
Material and labour for point wiring with 1.50 Sqm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
S&F electronic Fan regulator modular 100 watt, 2 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix ceiling fans, AC, single phase, 230 V, 50 Hz, copper wounded of 1200 mm sweep having service value more than or equal to 6 with BLDC technology , max power input up to 35 watt, copper wire induction motor with 5 star BEE ratings, complete along with canopy cover, down rod, 'U' clamp, 3 core PVC flexible cable 1sqmm for making connection of fan and hanging the fan in clamp, connecting with electrical connection all as specified and as directed by Engr-in-charge. Note ; - MES No shall be written by the contractor with permanent marker over ceiling fan of specified size and colour and quoted rate shall be deemed to be included of this element.
Supply & Fix Water heater (Geyser) storage verticle type electric of capacity 25 Ltrs , BEE 5 Star rated, ABS body, inner tank of stainless steel enamel coating with glasss lined coating, multiple heating option, shock safe plug, puf insulation, incoloy glass coated anode rod / copper heating element of capacity 2KW with ISI mark , adjustable knob for temp setting with minimum 8 Bar high working pressure, multi functional safety valve & whirl/Swirl flow technology, thermostat electronic type, thermal cutout capillary type complete including superior quality PVC connection pipe heavy duty steel braided 15 mm dia 450mm long suitable for hot & cold water, stainless steel adopter for water connection with nikhel coated ISI marked with fastner, nut bolts, washers duly grouted, giving shape to hole as suitable and plastering including making good of disturbed surface as per existing surface, connecting to inlet and outlet valves, testing complete all as specified and as directed by Engineer-in-Charge. Note :- Warranty certifcate to be produced by the Contractor from OEM for the following components before processing the bill. a) for Product - 02 Years b) for Heating element - 03 Years c) for metal tank - 07 Years
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 3/3 pin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S & laying sub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 4 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
M & L cutting existing steel tubing 15mm bore for alterations or additions and providing 15mm bore GI tee for taking conncetions complete all as specified and as directed by Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated angular stop valves with capstan head, screwed down, high pressure scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S&F bib taps 15mm bore fancy type brass chromium plated with long body, wall flanges and capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SP, 6-32 Amps, 240 volt,10 KA , 'B' curve complete all as specified and as directed by the Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA, 'B' curve complete all as specified and as directed by the Engr-in-charge.
Supply and fix MCB SPN, 32/40 Amps, 240 volt,10 KA , 'B' curve complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed by the Engr-in-charge.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 10 sq mm nominal cross section cable with PVC insulated aluminium conductor multistranded served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, complete all as specified and as directed by the Engineer-in-Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to earthing test point as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
Supply and fixing industerial type heavy duty wall mounting fan 600 mm sweep with corrosion resistant metalic body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades , 1440 RPM, 240 volts, air capacty / air delivery (C.F.M) - 9534, aluminium blades (3 Nos.), base of the fan of strong cast iron, powder coated metalic finish paint and testing complete all as specified and as directed by Engineer-in-Charge.
Supply and fix switch piano, single pole, one way 15 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix socket outlet 3/3 pin combined, (6pin), 6/16 Amp, flush type 230 volts complete all as specified and as directed by Engineer-in-Charge.
S & laying sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
S & laying sub main wiring with two run of 1.5 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 1.5 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Material and labour for point wiring with 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
S & F rectangular box of size 175 x 100 x 50 mm made from mild steel pressed sheet 1.25 mm thick with and including 3 mm thick plastic laminated sheet cover of suitable size for mounting, switches, sockets etc. Including two coats of synthetic enamel paint black over a coat of red oxide primer and fixing with brass screws and cup washers complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable 35 sqmm cross sectional area, 3.5 core with aluminium conductor, 1100 volts grade complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, GI pipes and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
S&F light grade GI Tubing of size 40mm dia for cable protection and fixed with clamp to pole and wall with nut, bolts, washers complete all as specified and as directed by Engineer-in-Charge
M&L dry sand cushoning to cable i.e 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting complete all as specified and as directed by Engineer-in-Charge. Note: punned thickness shall be measured for payment.
Supply and laying well burnt brick class-B laid flat to cover the cable with width equal to the length of cable and abutting each other for protection of cable complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Mohinder Pal and Sons
unique power & control system
Saurav Enterprises
M/s Kang Builders & Developers
S.R. Constructions
Alpha Engineers and Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .