Tender Value
₹1.3 Cr
EMD Value
₹2.5 L
Closing Date
25 Jan 2023, 3:00 pmClosed
Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, Installation and Commissioning of Air Conditioning system for the 750 seated capacity Auditorium of Tripura Medical College, Agartala, Tripura
2023_CEPWD_36739_1
26/B/DNIeT/SE-IV/PWD(RANDB)/20
Open Tender
Electrical Works
Works
180 days
AGARTALA
Please refer Tender documents.
7 documents required · 7 mandatory
₹4,000
₹2.5 L
10 Apr 2023
14 Jan 2023
25 Jan 2023
14 Jan 2023
25 Jan 2023
14 Jan 2023
Amount
Providing, Installation & Commissioning in/c vaccumising, Nitrogen pressure leak testing, lifting, sifting, placing at machine room etc. of 22 TR floor mounted ductable AC units (Indoor & Outdoor Unit) working on 3 Phase 380 to 415 V (±) 50Hz power supply , Machine should be designed on inverter technology and functional with suitable refrigerant as per design parameter of manufacturer etc. complete as per direction of Engineer -in- charge.
Providing Refrigerant Gas 410/410A or equivalent as a standard requirement for charging etc. complete as per direction of the Engineer- in-charge.
Providing & Installation of Hard Drawn Copper piping complete (without insulation) as per direction of the Engineer- in-charge. 1 ⅛ inch OD
Providing & Installation of Hard Drawn Copper piping complete (without insulation) as per direction of the Engineer- in-charge. 5/8 inch OD.
Providing & installation of 25 mm NB PVC drain piping complete as per direction of the Engineer -in-charge.
Supply & erection of GI Ducting complete as per direction of the Engineer- in-charge. 22G GSS Sheet.
Supply & erection of GI Ducting complete as per direction of the Engineer- in-charge. 24G GSS Sheet.
Supply & erection of inside Duct acoustic insulation with 10 mm thick (Class -1 Accosound) Nitrale with perforated aluminium sheet complete as per direction of the Engineer -in-charge.
Supply & erection of Thermal insulation with 13 mm thick Nitrale with aluminium foil complete as per direction of the Engineer- in-charge.
Providing & connecting Electric control cables between indoor & outdoor, Machine room Supply point to indoor machine suitable cable for 3-phase line in/c Neutral etc complete as per direction of the Engineer -in-charge.
Supply & erection Canvas connection complete as per direction of the Engineer- in- charge.
Providing & installation Outdoor structure or Pedestal complete as per direction of the Engineer- in-charge.
Providing & Installation Grilles/Diffusers complete as per direction of the Engineer in charge.
Providing & Installation VI Pad for outdoor unit complete as per direction of the Engineer- in- charge.
Providing & Installation Fire dampers with fusible link complete as per direction of the Engineer- in-charge.
Supply & erection under deck insulation of with 50 mm thick thermocol slab or 32 mm XPL sheet complete as per direction of the Engineer- in-charge.
Supply & erection duct dampers (Manual GI material) complete as per direction of the Engineer in charge.
Supply & erection MS Collar Dampers complete as per direction of the Engineer in charge.
Providing fitting fixing of thermal insulation of 50 mm thick resin bonded fibber glass or 32 mm glass wool insulation covered tissue board/ XPL sheet on the wall and ceiling fixed with frame work with GI channel covered with 26G AL perforated sheet and finally fixing with Al flat in complete as per direction of the Engineer- in-charge.
Providing of Split type High wall minimum 2.00 TR (6,000 Kcal/ hr.) split A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must have copper pipe) suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge.
Standard installation testing and commissioning of 1.5 TR/ 2TR capacity High wall split Air Conditioner in/c making necessary scaffolding as per requirement etc complete as per direction of the Engineer-in-charge.
Supplying and installation of additional length of copper pipe of suitable diameter for suction and liquid line with insulation and necessary wiring between indoor and outdoor units beyond the standard length etc. complete as per direction of the Engineer- in-charge.
Fabrication of MS platform for placement of condensing unit by using MS Angle of (50 x 50 x 5) mm size base plate nuts & bolts etc. or suitable Cradle In/c painting fitting fixing grouting by cement mixture / fitting fixing of cradle of suitable sizes as per direction of the Engineer- in-charge.
Opening/ making hole, cutting of wall of the auditorium for supply & returned duct of Stage portion, Middle Portion, (as required) & related wall of the machine rooms and after completion of the ducting work repaired the same holes gaps by bricks & cement plastering, painting etc . Complete as per direction of the Engineer- in-charge.
Supply & erection of Thermal insulation with 50 mm thick thermocol slab or 32 mm thick XPL/ Nitrile sheet for outside duct complete as per direction of the Engineer- in-charge.
Sand Cement Plastering (1:4) of the outside Duct in/c wrapping Chicken Wire Mesh on the insulated duct & necessary M.S. angle Support as per direction of the Engineer- in- charge.
Making Bamboo Scaffolding for erection/ installation of Duct, under deck insulation, fitting Fixing of Defuser griller etc. complete as per direction of the Engineer- in-charge.
Providing for Installation of Variable Refrigerant Flow (VRF) System Outdoor units of AC machines minimum capacity of 22 HP or 17.6 TR each Top discharge, Modular type only cool, next generation VRF, each outdoor unit comprises of 100% inverter Driven Hermetically sealed Scroll Compressors , air cooled condenser with protective coated fins heat exchangement corrosion fin factory coated propeller type fan with motor , specially designed ODUs with refrigerant cooled heat sink , nonstop working at 56 degree C, with R410A or equivalent Refrigerant , working on 3 phase AC range of 380 volt to 420 (±5%)Volt, 50Hz , the outdoor unit should contain error code LED display for ease of operation, auto addressing setting refrigerant cool PCB, Electronic expansion Valve, microprocessor controller, VRF unit should be compatible with AHU/TFA etc. complete as per direction of the Engineer- in-charge.
Providing for Installation of Variable Refrigerant Flow (VRF) System type indoor unit comprising of Copper coil section, filter section, micro processor type PCB , the unit shall be ceiling suspended type and complete with all standard accessories etc. complete as per direction of the Engineer in charge VRF four way cassette unit Capacity minimum 2.8 TR.
Providing & Installation of Remote Controller Compatible of VRF indoor Unit, Cordless controller etc. complete as per direction of the Engineer- in-charge.
Providing & fitting fixing of copper individual Refnet Y distribution joint IDU etc. complete as per direction of the Engineer -in-charge.
Providing & fitting fixing of copper individual Refnet Y distribution joint ODU etc. complete as per direction of the Engineer- in-charge.
Supply, installation, and commissioning of Cu refrigerant pipes (required as per OEM design) duly installed with 19 mm/ 13 mm close cell electrometric nitrile rubber insulation between each set of outdoor and indoor units (VRF) 41.3 mm dia. with 19 mm thick insulation.
Copper pipe 34.9 mm dia. with 19 mm thick insulation.
28.6mm dia. with 19 mm thick insulation
22.2 mm dia. with 19 mm thick insulation
19.1 mm dia. with 19 mm thick insulation
15.9 mm dia. with 13 mm thick insulation
12.7 mm dia. with 13 mm thick insulation
9.5 mm dia. with 13 mm thick insulation
Supply & installation testing of PVC pipe (for drainage of water from IDU) with 6 mm thick Nitrale Rubber insulation) Drain pipe 25 mm with 6 mm thick Nitrale Rubber insulation.
Drain pipe 32 mm with 6 mm thick Nitrale Rubber insulation.
Supply & lying of Copper conductor scheduled flexible communication cabling between ODU and IDU as per OEM specification (VRF) cable shall be lying through hard PVC conduit pipe.
Supply & fitting fixing of G.I. Cable Tray for laying of copper pipe support along with fittings as per required size 100 mm.
Supply & fitting fixing of G.I. Cable Tray for laying of copper pipe support along with fittings as per required size 150 mm.
Supply & filling of First charge of refrigerant R 410 A.
RS COOLING APPLIANCES
RBS REFRIGERATION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_37320.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .