Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹21.9 L+₹18,100 (0.83%)Rejected-Finance SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹22.6 L+₹82,055 (3.77%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹22.7 L+₹90,260 (4.15%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹24.6 L+₹2.9 L (13.2%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹29.8 L
EMD Value
₹59,640
Closing Date
3 Mar 2023, 6:00 pmClosed
Garrison Engineer, Banar
Garrison Engineer, Banar, Jodhpur-342027
REPAIR/MAINT OF LT PANEL, UG CABLES, LT OVERHEAD CONDUCTOR AT RALAWAS UNDER GE BANAR
2023_MES_578856_1
8822/74/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹59,640
Yes
27 Mar 2023
3 Feb 2023
6 Mar 2023
3 Feb 2023
3 Mar 2023
17 Feb 2023
Amount
M & L for painting to internal and external surface of LT Feeder Pillar Box/Panel Boards various sizes with two coats of synthetic enamel paint over a coat of primer including making necessary surface preparation by scrapping the old painted surfaces with wire brush/emery paper complete as per specified
Supply and fix in repair Mild steel barrel tower bolts, 300mm long stove enamelled black, bright bolt. With connected accessories fixed on Front and rear side of the Doors for locking of LT FP Boxes complete all as per specified
Material and labour for clamps and back plates fabricated from steel sections size of upto 1.5x2mtr including nuts, bolts, washers, welding, bending, drilling holes for bolts, in any shape or size inclusive of one primer coat, one under coat and one finishing coat of aluminium paint all complete as per dirtected by EIC
Material and labour for MS sheet Min 3mm thick for making doors of panel boards/feeder pillar boxes including taking out the old damaged doors complete all as specified.
M&L Replacement of LT panel corroded / damaged doors of panel boards/feeder pillar boxes front side by cutting, bending, welding MS sheet to suit with the existing MCCB's including providing hinges ,door locking system complete all as specified.
Material and labour for bus bar made out of aluminium strip as per existing suitable size(R-Y-B) colour insulated sleeve for phases and black colour for netural with suitable size of clamps made out of flat iron, nuts, bolts and washers including cutting, bending, welding etc and suitable as per existing complete as directed by Engineer-in-Charge.
M&L for replacement of GI earth wire of 4 mm dia for guard on Overhead line by providing reels and clamps and any other items required for fixing as per site requirement complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement DIN rail of width upto 35mm for mounting of Add on block/MCBs and other electrical items into LT panel/feeder pillar/juncation box complete all as specified.
Supply and fix in replacement DIN rail terminal block for 4 wire termination of LT cables complete as per specified and directed by EIC
Taking out/Dismantling of existing unserviceable UG Cable of any size after disconnetion from LT panel/feeder pillar and poles and Supply,Laying and testing in trenches or fixing or passing through pipe 1100 volts grade heavy duty cable XLPE Insulated multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and over PVC sheathed of following sizes.
3.5 core 150 Sq mm
3.5 core 120 Sq mm
3.5 core 95 Sq mm
3.5 core 70 Sq mm
3.5 core 35 Sqmm
4 core 25 Sqmm
4 core 16 Sqmm
4 Core 10 mm
Excavation in trenches not. exc. 1.5m wide and not exc. 1.5 deep and getting out in soft/loose soil complete all as specified.
Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified.
Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified.
Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified
M&L for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for UG cable protection complete all as specified.
Laying only Old quarry faced stone slab retrived from Ser Item No 10.01 to 10.08 hereinbefore complete all as specified.
Dismantling of existing unserviceable GI pipe 80/40mm complete all as specified.
Boring under road and foot path for inserting 40/80 mm bore GI tubing for drawing UG cable, complete all as per specified NOTE- GI Pipe shall to be paid separatly.
Material and labour for 80 mm dia galvanized iron tube medium grade for cable protection pole ,plinth protection, road crossing, trenches, footpath etc, complete all as specified and directed including clamps, nut bolt and washers complete all as specified.
Material and labour for 40 mm dia galvanized iron tube medium grade for cable protection pole ,plinth protection, road crossing, trenches, footpath etc, complete all as specified and directed including clamps, nut bolt and washers complete all as specified.
Supply and fix LT straight through joint out door type of size 70 sqmm to 120 Sqmm 3.5 core suitable for PVC / XLPE power cables complete all as specified.
Supply and fix LT straight through joint out door type of size 25 sqmm to 50 Sqmm 3.5 core suitable for PVC / XLPE power cables complete all as specified.
Supply and fix LT Outdoor End termination joint out door type of size 25 sqmm to 50 Sqmm 3.5 core suitable for PVC / XLPE power cables complete all as specified.
Supply and fix LT Outdoor End termination joint out door type of size 70 sqmm to 120 Sqmm 3.5 core suitable for PVC / XLPE power cables complete all as specified.
Supply and fix LT Indoor End termination joint out door type of size 70 sqmm to 120 Sqmm 3.5 core suitable for PVC / XLPE power cables complete all as specified.
Supply and fixing in replacement MCCB 4 Pole 630 Amp 415 volt breaking capacity 36 KA with adjustable thermal and megnetic setting complete all as specified.
Supply and fixing in replacement MCCB 4 Pole 320 Amp 415 volt breaking capacity 18 KA with adjustable thermal and megnetic setting complete all as specified.
Supply and fixing in replacement MCCB 4 Pole 250 Amp 415 volt breaking capacity 18KA.with adjustable thermal and megnetic setting complete all as specified.
Supply and fixing in replacement MCCB 4 Pole 200 Amp 415 volt breaking capacity 16 KA.with adjustable thermal and megnetic setting complete all as specified.
Supply and fixing in replacement MCCB 4 Pole 125 Amp 415 volt breaking capacity 16 KA.with adjustable thermal and megnetic setting complete all as specified.
Supply and fixing in replacement MCCB 4 Pole 63 Amp 415 volt breaking capacity 16 KA.with adjustable thermal and megnetic setting complete all as specified.
Supply & fix in replacement digital power factor meter in existing APFC panels of sutable size having range of 1/5 A and 110v/230v/440v with all acessories complete all as specified.
Supply and fix in replacement CTs of ratio 200/5 A indoor resin cast ring type used on existing panel complete all as specified.
Supply and fix in replacement CTs of ratio 100/5 A indoor resin cast ring type used on existing panel complete all as specified.
Supply and fix in replacement CTs of ratio 50/5 A indoor resin cast ring type used on existing panel complete all as specified.
Supply and fixing in replacement LED type indicator lamp (RYB) (Set of three) complete all as specified.
Supply and fix in replacement Spreaders For LT Line heavy duty complete all as specified.
Supply & lay electrical insulation rubber matting of size 1mx2 mtrx19mm complete all as specified.
Dismantling of existing damaged unserviceable earth pits, test points, GI wire / GI Strip / copper strip of any size and M&L for new earth pit with Cover ,existing earth strip clamps properly,clean the earth pit, new funnel complete as per site requirment directed by Engr-in-Charge
M & L in replacement earthing complete with galvanised steel earth plate electrode 60 x 60x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron strip 32x6mm as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 40mm dia GI medium grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation of hard /dense soil and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 all as directed by Engr-in-Charge
M&L in replacement for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex head screw complete as specified
M&L in replacement for Earth continuity conductor or main earthing lead fixed to wall /floor connection of earthing lead to equipment fixed to poles or any other indicated situation for loop earthing etc as required 32X6 MM dia galvanised iron strip complete as specified
M & L in replacement Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps bolts and nuts of approved for LT 440 volts, of size 25 X15cms complete as specified.
Material & Labour for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundation of LT panel as per directed by Engr-in -charge.
Material & Labour for PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in copping of LT panel as per directed by Engr-in -charge.
Cleaning the Surrounding area (not less than 2.5X2.5 mtr) of Two/Four pole structure,Lt panel area, cutting the bushes,grass by root and leveling the soils, dressing the cables and two coat white wash on the panel foundation ,earth pit near around the Lt Panel etc complete as per directed by Engr-in-Charge
M&L for writing of LT panel number with black/blue colour on panels/feeder pillar box by professional painter with suitable size, height and width complete as specified.
M&L for White wash (Chunna) jodhpuri in rock foam two coat after cleaning of surface as per specified and as directed by Engr-in-Charge
Supply and fix front mounting Add on auxilary contact blocks of MO type as per existing NO+NC includling 2.5mm copper control cable upto 0.5 meter complete all as specified.
Supply and fix Side mounting Add on auxilary contact blocks of MO type as per existing NO+NC includling 2.5mm copper control cable upto 0.5 meter complete as specified and directed by EIC
Supply and fix Spare coil contact MO32 of L&T complete all as specified.
Supply and fix Spare coil contact MNX40/MO40 of L&T complete all as specified.
Supply and fix Electronic timer Type ST100 3-30 Sec for 240/415V 50Hz for switching loads on and off repetitively in equal intervals complete all as specified.
Supply and fix Handle assembly suitable for 100 to 800A ON/OFF complete all as specified.
Supply and fix Extended ROM for MCCB any size as per exisiting pannel complete all as specified.
Supply and fix Castell type Panel door lock set stainless steel surface mounted using suitable fasteners single key operated complete all as specified.
Supply and fix Tear drop Knobs upto 400A suitable as per exisiting complete all as specified.
Supply and fix Aluminium cable lugs for size Pin/bottle type upto 16 sqmm complete all as specified.
Supply and fix Aluminium cable lugs for size Pin/bottle type 16sqmm to 35 sqmm complete all as specified.
Supply and fix Aluminium cable lugs for size Pin/bottle 50 sqmm to 120 sqmm complete all as specified.
Supply and fix cable gland for different size per site requirement complete all as specified.
Re-routing /Re-Laying of Lt cables in trenches or passing through pipe 1100 volts grade heavy duty cable XLPE Insulated multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and over PVC sheathed of following size Note:-Excavation work,sand cushing etc paid separately
upto 50 Sqmm 3.5/4 core
50 Sqmm to120 sqmm 3.5 core
150sqmm to 240 sqmm 3.5 core
Dismantling of old ACSR conductor from Poles of any size and removal from site complete all as specified.
Supply and Fixing ACSR conductor on poles including stringing and fixing in position and binding to insulators and jumpers, complete all as specified
All as per Ser Item No 66.00 above but except ACSR conductor. Note: ACSR conductor shall be reused as obtained serviceable from Item No 65.00 above.
Dismantling and taking down cross arms of MS channel or angle sections, clamps, nut and bolt, washers, back plate of any size/shape complete and removal from site.
Supply and fixing cross arms, bracing supports clamps,ms sheet from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts in any shape or size complete all as specified.
M&L for painting with two coats of synthetic enamel paint over a coat of cross arms, bracing supports clamps,MS sheet from structural steel sections including steel poles complete all as specified. Note :- The item included in the painting 3 Nos 30 cm wide bands black & White synthetic enamel paint in alternate layer upto 1.0 mtr high above foundation and writing the pole No in 5 cm wide on base of Black colour with HT/LT as per direction of Engr-in-Charge.
Dismantling old unserviceable stay assembly complete including necessary excavation and demolition of concrete and removal from site complete all as specified.
Supply and fixing stay assembly complete with accessories as shown in electrical plate No. 1 of MES schedule part I with and including 20 mm dia stay rod, stay clamp and galvanized stay strand of size 7/4 mm including necessary clamps, nut, bolts etc complete all as specified.
Dismantling of unserviceable insulators of any type/size and Supply and fix shackle type vitreous white, brown or green insulators for working pressure 1100 volt of 90 mm dia and 75 mm height including galvanized mild steel straps of 31x3 mm size 12 mm dia insulator bolts, nuts & washers complete all as specified.
Dismantling of unserviceable insulators of any type/size and Supply and fixing pin type porcelain, vitreous, white, brown or green insulators including galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nuts, 100 mm height 65 mm dia for 1100 volts grade complete all as specified.
Dismantling of unserviceable insulators of any type/size and Supply and fixing loop type insulators vitreous, porcelain white, brown or green large size with over all dimensions of 90 x 140 mm clearance or hole 25.5 mm complete all as specified.
Perventive maintance of LT panels/feeder pillar box/Electric meter panel box comprissing of following works to be carried out as under:- (i) Cleaning of panel boards by hand/air blower after switching off main supply.(II) tighting of all electrical termination joints (iii) Dresing of internal control wiring and repairs of minor defects on the spot.
M & L for replacement of transformer LT bushing in site suitable for 1100 volts grade complete with brass rod, rubber bush washers nuts and cork sheet gasket for the rating 63 to 500 KVA indoor/outdoor transformer complete all as specified.
Supply and laying for 12.5 to 40mm Graded stone aggregate in area of installation arround the panel area and substation or as dirtected after cleaning the existing ground surface and removing grass and unorganic particales all as reqd and as directed at site complete all as specified.
S&F pasting transparent glass cover plate of 4x4inch size or as per existing suitable for electric meter panel board Top cover complete including four nos screwing complete all as specified.
M&L for Cutting of road, hard standing,PCC 45cmX45 cmmx30cm for laying of cable and making good surface give the shape of as cable trench as per site requirement as per directed by Engr-in-Charge
Dismantling of unserviceable LT pole of any type/size and removal from site complete all as specified.
Supply & install, Prestressed concrete pole 9 metres long 102mmx172mm at top and 112mmx279mm at bottom class 10 complete all as specified. Note: Earth work shall be measured & paid separately
Material & Labour for PCC 1:3:6 type C2 using 40mm graded aggregate as in coping/collar of poles and foundation of stay assembly etc complete all as specified
Dismantling of unserviceable LT Panel of any type/size and removal from site. and Supply, Installing,testing and commissioning of LT Panel factory made Outdoor type (CPRI) as per latest IS mark with following minimum thickness - Load bearing member/Doors - 3mm, Non-load bearing member/internal partitions - 3mm, Glandplate/Base channel-3MM , board floor mounted, dust and vermin proof, 3 phase 4 wire with rated operational voltage 415V, rated insulation voltage of 1000V and Impulse withstand of 12kV and minimum internal Arc with-stand of 65kA, 500mSec as per latest IS mark, weather proof, with separate hinge door for each compartment with Operating handle & locking arrangement with back door common openable(screwed/Lockable), grouted in PCC 1:2:4 Complete. Painting as per defined 7 Tank process with epoxy powder polymerized at high temperature and aluminium busbar (TPN) suitable for 500A with double compression aluminium cable glands with the following accessories with IP 54 rating :- (a) Incoming - MCCB 320 Amp 4 pole 415 V 35 kA rating (b) Outing - (i) MCCB 125 Amp 4 Pole 415V 18 kA - 02 Nos (ii) MCCB 63 Amp 4 Pole 415V 18kA - 04 Nos (iii) Spare compartment for MCCB - 01 No (iv) LED indicating lamps for main supply (R-Y-B) (v) Amp meter (vi) Volt meter
Dismantling of unserviceable LT Panel of any type/size and removal from site and Supply, Installing,testing and commissioning of LT Panel factory made Outdoor type (CPRI approved ) as per latest IS mark with following minimum thickness - Load bearing member/Doors - 3mm, Non-load bearing member/internal partitions - 3mm, Glandplate/Base channel-3.5MM , board floor mounted, dust and vermin proof, 3 phase 4 wire with rated operational voltage 415V, rated insulation voltage of 1000V and Impulse withstand of 12kV and minimum internal Arc with-stand of 65kA, 500mSec as per latest IS mark, weather proof, with separate hinge door for each compartment with Operating handle & locking arrangement with back door common openable(screwed/Lockable), grouted in PCC 1:2:4 Complete. Painting as per defined 7 Tank process with epoxy powder polymerized at high temperature and aluminium busbar (TPN) suitable for 350A with double compression aluminium cable glands with the following accessories with IP 54 rating :- (a) Incoming - MCCB 200 Amp 4 pole 415 V 35 kA rating (b) Outing - (i) MCCB 125 Amp 4 Pole 415V 18 kA - 01 Nos (ii) MCCB 63 Amp 4 Pole 415V 18kA - 04 Nos . (iii) SPN 32Amp - 02 Nos (iv) LED indicating lamps for main supply (R-Y-B) (v) Amp meter (vi) Volt meter
Sachiyay maa Electricals
Nvimal Engineers and Contractor
M/S SHREE AAINATH ENTERPRISES
Shri Electrical Enterprises
Anil Builders
M/s Vishaka Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .