| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 263 URBAN ESTATE PHASE II BATHINDA | BATHINDA | PUNJAB | 151001 | ₹1.1 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹1.1 Cr+₹51,566 (0.46%)Rejected-AOC | ₹1.1 Cr+₹51,566 (0.46%) | L2 | Rejected-AOC Not Lowest |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.2 Cr
EMD Value
₹2.3 L
Closing Date
29 Jul 2022, 2:00 pmClosed
Executive Engineer (Electrical)
Executive Engineer (Elect.), PAU, Ludhiana
Providing E.I. Work in Construction of main building of new College of Agriculture at Regional Research Station, Ballowal Saunkhri
2022_PAU_86962_1
Endst. No. 681-692 dated 17.06.2022
Open Tender
Electrical Works
Multi-stage
915 days
PAU
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
₹2.3 L
Yes
16 Sept 2022
18 Jun 2022
1 Aug 2022
18 Jun 2022
29 Jul 2022
18 Jun 2022
Amount
A. ELECTRICAL ACCESSORIES S/E of LED Tube light highly durable surface mounted with T-8 LED, 20 watt Tubular Lamp and decorative end caps etc. ,with 2 year onste warranty ,complete (Fitting & Tube lamp) in all respect as desired by Engineer-in-charge (Make: Crompton/Havells/Wipro/Phillips)
S/E of energy efficient LED batten highly durable surface mounted, 40 watt installed at 25Ft Approx , complete in all respect with two year on site replacement warranty as desired by Engineer-in-charge at site. (Make: Crompton/Philips/Wipro/Havell's)
S/E of Energy Saving LED Street Light 40w luminaire with system efficiency 110Lm/watt Aluminum PDC housing, with powder coated, IP 66 Protection, Fiberglass insulated multi strand wire, Covering heat resistant toughened glass. High bright white power LED Surge Protection Device should be Separate, installed in Luminaries up to 10KVwith 2 Year on site warranty,complete set along with all required accessories as desired by Engineer-In Charge at site. (Make Crompton/Wipro/Havells/Phillips)
S/E of Energy Saving LED Street Light 60w luminaire with system efficiency 110Lm/watt Aluminum PDC housing, with powder coated, IP 66 Protection, Fiberglass insulated multi strand wire, Covering heat resistant toughened glass. High bright white power LED Surge Protection Device should be Separate, installed in Luminaries up to 10KVwith 2 Year on site warranty,complete set along with all required accessories as desired by Engineer-In Charge at site. (Make Crompton/Wipro/Havells/Phillips)
S/E of Energy Saving LED Street Light 90w luminaire with system efficiency 110Lm/watt Aluminum PDC housing, with powder coated , IP 66 Protection, Fiberglass insulated multi strand wire, Covering heat resistant toughened glass. High bright white power LED Surge Protection Device should be Separate, installed in Luminaries up to 10KVwith 2 Year on site warranty,complete set along with all required accessories as desired by Engineer -In Charge at site. (Make Crompton/Wipro/Havells/Phillips)
S/E of vetilator plastic Exhaust Fan10'' complete in all respect with required fixing arrangements, as desired by engineer In charge (Make: USHA/Crompton/Havells)
S/E of Exhaust Fan12'' complete in all respect with required fixing arrangements, as desired by engineer In charge( Make: USHA-Turbo LD DBB /Crompton-TransAir/Havells)
S/E of Heavy Duty Exhaust Fan18'' complete in all respect with required fixing arrangements, as desired by engineer In charge (Make: USHA/Crompton/Havells/GEC)
S/E of ceiling fan 56" with required fixing arrangements, as desired by engineer In charge (Make: Crompton greaves- High Speed/USHA- striker,/Havell's-XP)
S/E of ceiling fan 48" with required fixing arrangements, as desired by engineer In charge (Make: Crompton greaves- High Speed /USHA- striker,/Havell's-XP)
S/E of wall fan 16" with required fixing arrangements, as desired by engineer In charge at site. (Make: Crompton/Havell's/Usha)
Supply & Erection of 600mmx600mm 36watt recessed mounted LED Fixture with full diffuser with minimum lumens efficiency of 100 Lm/watt with APFC constant current driver for proper driving of LED. The input voltage range shall be150 V to 270V.The LED driver shall be of isolated type with constant current and constant voltage topology to ensure optimum driving of LEDs .The LED driver shall be have minimum 2.5 KV of surge protection,complete in all respect as desired by Engineer-in-charge at site. (Make: Crompton/Wipro/Havell's/Phillips)
Supply & Erection of 300mmx1200mm 40watt Surface/Recessed mounted LED Fixture with full diffuser with minimum lumens efficiency of 100 Lm/watt with APFC constant current driver for proper driving of LED. The input voltage range shall be150V to 270V. The LED driver shall be of isolated type with constant current and constant voltage topology to ensure optimum driving of LEDs. The LED driver shall be have minimum 2.5 KV of surge protection,complete in all respect as desired by Engineer-in-charge at site. (Make: Crompton/Wipro/Havell's/ Phillips)
Supply & Erection of surface mounted Round LED 18/20 watt PDC PCA housing.The LED driver shall be of isolated type with constant current and constant voltage topology to ensure optimum driving of LEDs, Efficacy 100 lm/w complete in all respect as desired by Engineer-in-charge at site. (Make: Crompton/Wipro/Havell's/Phillips)
TRANSFORMER:- S/E Testing and commissioning of 11/.433 KV Compact substation (CSS) 315 KVA complete with fixed manual switch fuse unit in SF6 insulated stainless Steel Enclosure, 1 no incomer 11KV 630Amps 21KA, VCB Protection IP67, with series trip, self-powered microprocessor based numerical over current relay (IDMTL + Inst.) protection & LT Panel outgoing MCCB 630Amps 433V 4P 50Hz 36KA Fixed Manual Type (MCCB) with Microprocessor based overcurrent, short circuit & Earth Fault Release,Spreader links for two or More cable 3½ core 300 sqmm. 3½ Core 150 sqmm. Cables terminations,with Off load tap switch of rating +5% to -5% @ 2.5%. Insulation Class A. Temp Rise in Oil/Winding shall be 40/45º C respectively. along with protection relays,CT, PT's,OTI & WTI with alarm & trip contacts transformer 315 kVA copper wound oil type ONAN, BusBar, with all assecories complete along with (Foundation) CIVIL / MECHANICAL Structure Description as per DNIT item No. 43
Dismantling ,Shifting of existing HT/LT line /Poles conductor etc. Street light Pole ,change Single Arm brackets with new Double Arm brackets complete in all respect as desired by Engineer-in-charge.
Supply Erection of powder coated/anodized concealed Light Deep with PVC cover plate for fire detection system complete in all respect as desired by Engineer -In -Charge at site.
B. NETWORKING:- S/E and laying of CAT-6 Cable complete in all respect as approved by the Engineer-in-charge at site. ( Make: AMP, Schenider, MOLEX or Equivalent)
Supply Installation of 24 Port Patch Panels fully loaded complete in all respect as approved by the Engineer-in-charge at site. (Make: Molex/Extreme/schenider or Equivalent)
Supply Installation of Indoor Rack Mount Console Unit-12U, 1 no. PDU 5Amp socket 5 no.,cable manager, fan complete in all respect as approved by the Engineer-in-charge at site. (Make: NETRACK/WALRACK or Equivalent)
Supply Installation of Indoor Rack Mount Console Unit - 15U, 1 no. PDU 5Amp socket 5 no.,cable manager, fan complete in all respect as approved by the Engineer-in-charge at site. (Make: NETRACK/WALRACK or Equivalent)
C. AIR CONDITIONING S/E of 2.0 TR 4/5 Star Inverter Split Air conditioner (Copper) with rotary compressor to be installed on walls with stand for outdoor unit complete in all respect as desired by Engineer -In -Charge at Site. Make :- O General, Daikin, Hitachi, Mitsubishi
S/E of 1.5 TR Inverter Five Star Split Air conditioner (Copper) with rotary compressor to be installed on walls with stand for outdoor unit complete in all respect as desired by Engineer-In-Charge at site. Make :- O General, Daikin, Hitachi, Mitsubishi
S/E of copper refrigerant piping(15.88mm*6.35) complete with proper 9 mm insulation ,fittings, elbow,bends, with supporting arrangement for walls, civil work etc for 2TR/1.5 TR split air conditioner complete in all respect as desired by Engineer-In-Charge at Site. Make:- Totalline, Ryoku,VRV
S/E hard PVC Pipe of 25 mm dia to withstand pressure of 10kg/cm² for drain of Airconditioners complete in all respect as desired by Engineer-In -Charge at Site (Make-: Supreme/JINDAL/FINOLEX/DIPLAST)
SANT RAM KATHURIA
SANT RAM KATHURIA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .