Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.4 Cr
EMD Value
₹1.4 L
Closing Date
12 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
building Department, Bhavnagar Municipal Corporation, Sir Mangalsinhji Road, Kalanala, Bhavnagar - 364001
PROPOSED WORK FOR CONSTRUCTION OF COMMINITY HALL AT TPS NO- 8(RUVA) F.P. NO-30 AT RUVA (PHASE-II)
356627
BUILDING/ RUVA COMMUNITY HALL PHASE-II /2026-27
Open
Civil Works - Buildings
Works
Bhavnagar
8 documents required · 8 mandatory
₹3,600
commissioner of bhavnagar municipal corporation
₹1.4 L
19 Oct 2026
19 Oct 2026
19 Oct 2026
12 Nov 2026
19 Oct 2026
NAME OF Work : PROPOSED EXTENTION OF COMMUNITY HALL AT T.P.S NO :- 8 (RUVA) F.P. NO :- 30, AT :- RUVA, DIST :-
NAME OF DOCUMENT: Schedule - B
Rate Total Amount
Rate Total Amount
Item No. Item Description Quantity Unit
1) The method of excavation shall be approved by
the Engineer in charge before execution.
2) Excavation shall be carried out very carefully
without damaging existing structures and
surrounding if any.
3) If required, the contractor shall provide
stabilization by any means to protect the
foundation of the existing structure and building
without any extra cost.
4) Rate shall include dewatering work (pumping
out and removing slush) while execution in
underwater condition if required.
Excavation for foundation in any kind of soil incl.
sand, soft or hard marum, soft rock not requiring
Blasting incl. dewatering if required at cost and risk of
agency incl. shoring, struting, making the bottom level
and sides in plumb incl. watering, raming and
1 consolidating the bottom etc. incl. removing the 3.75 Cmt 211.23
surplus stuff and black cotton soil if any within all lead
and lift using the selected stuff for back filling to
foundation, in side trenches and plinth in layers of
cms. th. with watering, consolidating etc. comp. as
directed. (A) up to 1.50mt.
Boring holes 3.5 m deep in ordinary soil (for cast in
situ piles) and getting out the soil and disposal of the
surplus excavated soil as directed within a lead of
Meter for following diameter of pipes. (iii) 300 mm
Filling available excavated earth (excluding rock) in
trenches. plinth, sides of foundations etc. in layers not
exceeding 20 cm. in depth consolidating each
disposited layer by ramming and watering.
1) All types of shuttering shall be designed by the
contractor and submitted to the
Engineer-in-Charge along with design
calculations (if required) and approved by the
Engineer-in-Charge. However, the stability and
compatibility of shuttering shall be the
responsibility of the contractor. Shuttering shall
be executed as per the approved shop drawing.
No extra payment shall be made for the above.
2) Rate shall be inclusive of dewatering work
(pumping out and removing slush) while
execution in underwater conditions. The
contractor shall not claim for dewatering if
3) Rate shall be inclusive of providing grooves,
drip moulds, pockets, cut-outs, etc., and
co-ordination of insert sleeves, insert plates (cost
of insert sleeves/plate shall be paid separately),
encasing if any wherever required while casting
for all level all height.
4) With reference to the testing of piles on site,
following types of tests need to be done without
any extra cost:
a) Initial Load Test: Minimum 2 number of
separate Test Piles (other than foundation piles)
to be casted and tested in near vicinity. These
piles to be tested to maximum of ultimate load
and 2.5 times the estimated safe load. Report
shall be submitted to the Engineer-in-Charge from
authorized agency.
b) Routine Test: 1% of total piles (minimum
piles) to be tested for Compression, Tension, and
Lateral Capacity of piles separately, i.e. 2 for
Compression, 2 for Tension, and 2 for Lateral
Capacity of piles.
5) Only the following approved brands of cement
shall be used for all works: [ultratech], [sanghi],
[Siddhi], [Hathi] and [Ambuja]. Use of any other
brand shall not be permitted without prior written
approval of the Engineer-in-Charge.
6) If the concreting quantity is more than 5 cum in
a day, then the casting shall be carried out using
RMC (Ready Mix Concrete).
If the concreting quantity is 5 cum or less in a day,
then the casting shall be done manually.
All concreting work shall be carried out strictly as
per the advice and instructions of the
Engineer-in-Charge.
Providing and laying cement concrete 1:3:6
(1-Cement : 3- coarse sand : 6- hand broken stone
4 aggregates 40 mm nominal size) and curing complete 0.45 Cmt 3106.67
excluding cost of formwork in (A) Foundation and
Providing and laying in position Ready Mixed M-250
grade concrete for reinforced cement conctere work,
using cement content as per approved Design Mix
manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead
up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of
5 R.M.C. from transit mixer to site of laying, including 1.46 Cmt 5727.96
the cost of centering, shuttering, finishing, admixtures
in recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve
workability without impairing strength and durability
but excluding the cost of reinforcement as per
direction of the Engineer-in-charge. Without Fly Ash
(Min cement level as per latest IS 456 shall be
maintained) (A) Foundation
Providing and laying in position Ready Mixed M-250
grade concrete for reinforced cement conctere work,
using cement content as per approved Design Mix
manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead
up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of
6 R.M.C. from transit mixer to site of laying, including 2.43 Cmt 9410.42
the cost of centering, shuttering, finishing, admixtures
in recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve
workability without impairing strength and durability
but excluding the cost of reinforcement as per
direction of the Engineer-in-charge. Without Fly Ash
(Min cement level as per latest IS 456 shall be
maintained) (D) Columns
Providing and laying in position Ready Mixed M-250
grade concrete for reinforced cement conctere work,
using cement content as per approved Design Mix
manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead
up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of
7 R.M.C. from transit mixer to site of laying, including 13.12 Cmt 6526.60
the cost of centering, shuttering, finishing, admixtures
in recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve
workability without impairing strength and durability
but excluding the cost of reinforcement as per
direction of the Engineer-in-charge. Without Fly Ash
(Min cement level as per latest IS 456 shall be
maintained) (C) Coping and Beams
Providing and laying controlled cement concrete
8 M-250 for R.C.C. bored piles of 1.20 Mt. diameter 3.36 Cmt 4802.65
including ramming, vibrating and finishing complete.
Providing and laying in position Ready Mixed M-300
grade concrete for reinforced cement conctere work,
using cement content as per approved Design Mix
manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead
up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of
9 R.M.C. from transit mixer to site of laying, including 27.59 Cmt 9602.41
the cost of centering, shuttering, finishing, admixtures
in recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve
workability without impairing strength and durability
but excluding the cost of reinforcement as per
direction of the Engineer-in-charge. Without Fly Ash
(Min cement level as per latest IS 456 shall be
maintained) (D) Columns
Providing and laying in position Ready Mixed M-300
grade concrete for reinforced cement conctere work,
using cement content as per approved Design Mix
manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead
up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of
10 R.M.C. from transit mixer to site of laying, including 85.23 Cmt 6718.60
the cost of centering, shuttering, finishing, admixtures
in recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve
workability without impairing strength and durability
but excluding the cost of reinforcement as per
direction of the Engineer-in-charge. Without Fly Ash
(Min cement level as per latest IS 456 shall be
maintained) (C) Coping and Beams
Providing and laying in position Ready Mixed M-300
grade concrete for reinforced cement conctere work,
using cement content as per approved Design Mix
manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead
up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of
R.M.C. from transit mixer to site of laying, including
the cost of centering, shuttering, finishing, admixtures
in recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve
workability without impairing strength and durability
but excluding the cost of reinforcement as per
direction of the Engineer-in-charge. Without Fly Ash
(Min cement level as per latest IS 456 shall be
maintained) (C) Slabs, landing, shelves and
Providing TMT Bar CRS - FE 500D reinforcement for
R.C.C. work including bending, binding, placing in
12 position, hooking, tying welding and including forming 33193.33 Kg 77.29
the cage and lowering it in position etc. complete of
Specific brands - Tata Tisco/Vizag/ET/JSW/SAIL
1) Masonry work shall be carried out for all floors, all
levels, all heights, and all locations, including loading,
unloading, stacking, transporting, hoisting, and
erecting by any means (mechanical or manual)
2) Only the following approved brands of cement
shall be used for all works: [ultratech], [sanghi],
[Siddhi], [Hathi] and [Ambuja]. Use of any other brand
shall not be permitted without prior written approval of
the Engineer-in-Charge.
Brick work using common burnt clay building bricks
having crushing strength not less than 35 kg./Sq.Cm.
13 in superstructure above plinth level upto floor two 128.73 Cmt 4599.16
level in Cement Mortar 1:5 (1- Cement : 5 -fine sand)
(B) Conventional
Half brick masonry in common brunt clay building
bricks having crushing strength not less than
14 Kg/Sq.Cm. in in superstructure above plinth level upto 27.18 Smt 683.87
floor two level in Cement mortar 1:4 (1- Cement :
-coarse sand ) (B) Conventional
1) All loose samples of materials shall be
approved by the Engineer in charge.
2) The contractor shall prepare shop drawings
based on intent/ concept drawing and get
approval from the Engineer-in-Charge. The
contractor shall prepare mock-up of doors,
windows, and other elements with all required
hardware and approved by the
Engineer-in-Charge before execution of work.
Work shall be carried out as per the final
approved shop drawing and approved mock-up.
The contractor shall be responsible against
stability, safety, leakage, etc all complete. Testing
work shall be carried out by the Contractor as
suggested by the Engineer in charge. (If required).
3) All Doors, windows, and other elements shall
be fabricated and finished at the factory/
workshop, and only fixing and final finishing shall
be executed at the site unless otherwise approved
by the Engineer-in-charge.
4) Door, window and other elements work shall be
carried out for all floor, all level, all height, all
places including loading, unloading, stacking,
transporting, hoisting, erecting by any means
(mechanical or manual).
5) Engineer incharge reserves right to reject part
or all work of sub standard or not in confirmation
to sample approved/or not as per mock up and in
such case contractor required to re do the same
work confirming with approved sample/mockup
without any extra cost. Approved mock up works
shall be measured for payment without any
wastage However, rejected Mock up shall not be
measured for payment.
Providing and fixing 35 mm thick flush door shutter
flat pressed wood based exterior grade bonded
BWP/BWR synthetic resin having stamped IS
grade I type II including both sides 1 mm thick
Decorative laminated and 6 mm thick I.T.W. beading
all around by using 120 m.m. x 80m.m.. solid core
malemine faced three layered I.T.W. frame with
15 necessary groove cutting and Stainless steel 20.68 Smt 4217.27
decorative type designs fixtures / fastening
2Nos.Satin Finish Mortise Handle with lock, towerbolt,
Floor door stopper, hinges etc. including I.T.W.
triangular batten patti of size 30m.m.x30m.m.etc. as
per architectural requirement and as directed by
engineer in charge. (Double Shutter)
Providing 30mm thick 100% Solid WPC (Wood
polymer Composite) Solid Plain (wooden figure)
Flush Door Shutter of required size comprising of
virgin PVC resin of K Value 57-60 (Suspension
Grade) with Door Frame 100 mm x 50 mm Single
Rebated made from Wood Polymer Composite
(Single Extruded Process) material comprising of
virgin PVC polymer of K Value 57-60 (Suspension
Grade), Calcium Carbonate and natural Fibers (Wood
16 Powders/ rice husk/ wheat husk) and Non toxic 14.08 Smt 5715.76
additives, made from Extrusion process WPC foam
sheet Single Extruded (Inner) For WC / Bathroom /
Toilet / Kitchen / Balcony Doors Including all required
hardware materials labours and equipments with
fixing as per approved sample detailed specification
as directed Engineer in charge with all lead and lift.
As per attached Detail specification. (including all
2Nos.Satin Finish Mortise Handle with lock, towerbolt,
Floor door stopper, hinges etc. complete)
Providing and fixing window having extruded
aluminum Colour anodized section frame main outer
size 95 mm x 24 mm x 1.17 mm @ wt. of
Kg/mt, horizontal Three track member size 92 mm x
31.75 mm x 1.30 mm, @ Wt. 1.07 Kg/mt, vertical
member of size 92 mm x 31.75 mm x 1.50 mm @ Wt.
1.06 Kg/mt with sliding shutters of horizontal member
size 40 mm x 18 mm x 1.29 mm @ wt. of
Kg/mt, vertical member of size 40 mm x 18 mm x
mm @ wt. of 0.456 Kg/mt / with 5 mm thick
transparent bronze colour tinted float glass with
powder coated aluminum fittings and fixtures and
transparent silicon sealant glass fixing to frame as per
Providing and fixing standared extruded of
alluminium section of size 63.50 x 38.10 x 1.95 mm @
Wt 1.094 Kg/Rmt with colour anodized alluminium
18 frame with 5 mm thick transparent bronze colour 4.56 Smt 1301.82
tinted float glass with colour anodized alluminium
frame for ventilation with 5 mm thick frosted glass as
details etc complete.
Providing and fixing Aluminium Framed & 12 mm
thick toughened glass door shutter of approved brand
and manufacture, including providing and fixing top &
bottom fitting arrangement and making necessary
holes etc. for fixing required door fittings, all complete
as per direction of Engineer-in-charge.
1) All types of loose and laid samples of flooring
shall be approved by the Engineer-in-charge.
The contractor shall apply approved Stone
Impregnation primer/ sealer coat on both sides
and all edges (after cutting and finishing the stone
as per size) of stones in a minimum of two coats
as per the manufacturer's specification and as
directed by the Engineer-in-charge. No extra shall
be paid for the same.
2) Contractor shall co-ordinate and execute for all
services in flooring and wall lining/ cladding work
i.e. making openings/ cut-outs for any services
(i.e. elevator operating panel in lift wall cladding,
raceway in flooring, junction box, etc), and
making good as per the satisfaction of
Engineer-in-charge.
3) Flooring and wall cladding/ lining work shall be
carried out for all floors, all levels, all heights, and
4) Rate shall be inclusive of all types of wastage
of all material.
5) Only the following approved brands of cement
shall be used for all works: [ultratech], [sanghi],
[Siddhi], [Hathi] and [Ambuja]. Use of any other
brand shall not be permitted without prior written
approval of the Engineer-in-Charge.
Providing and laying polished Kota stone slab flooring
over 20 mm (Average) thick base of cement mortar
1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5
20 (1-Limeputty : 1.5-coarse sand) laid over and jointed 7.80 Smt 1019.40
with grey cement slurry mixed with pigment to match
the shade of slab including rubbing and polishing etc.
complete. (A) 25mm thick
Providing and laying polished kota stone slab 25 mm
thick in risers of steps, skirting Dedo and pillars laid
on10 mm thick cement mortar 1:3 (1-Cement :
3-coarse sand) and jointed with gray cement slury
mixed with pigment to match the shade of slab
including rubbing and polishing etc. complete.
Providing and laying Polished Granite stone flooring
and skirting in required design, colour and patterns, in
linear as well as curvilinear portions of the building all
complete as per the architectural drawings with
mm thick stone slab over 20 mm (average) thick base
22 of cement mortar 1:4 (1 cement : 4 coarse sand) laid 153.95 Smt 3695.31
and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching
shade including rubbing, curing and polishing etc. all
complete as specified and as directed by the
Engineer-in-Charge.
Providing and fixing of minimum 16 mm thick
telephonic Black Granite stone slab for jambs of doors
and window. Black Granite should be spotless,
without any crack, vain or other damages joined with
grey cement slurry and matching pigment in vertical
and horizontal member, including rubbing and
polishing and full round edge molding on both the
sides( edge), Mirror polishing curing of the Black
Granite stone as per detail design and instruction.
The door frame should have sandwich type Jambs
23 stone fitting to accommodate fixing of door where 79.23 Smt 2571.06
required, the fixing of jambs with necessary binding
wire tiles piece, adhesive, clamp, fastener, white
cement and matching pigment other consumable,
molding and polishing machinery other tools, tackles
required to complete the item and where two member
vertical and horizontal meet it should cut 45 degree
angle etc up to all floor with all lead & lift etc
complete. The Black Granite stone size and quality
should be as per sample approved by architect and
Engineer in charge.
Providing and fixing 750 mm wide Granite sand
which type platform, counter wash basin including
supplying and fixing granite stone 18 mm thick mirror
polished 1st quality Granite stones in top and side
posiition and vertical strip at front over 25 mm thick
polished kotah stone platform fixing in top and sides
and itermediates supports fixing with cement mortar
and adhesivee and finishing including providing &
cutting of kitchen sink (as directed) 600 mm x 450 mm
x 150 mm size stainless steel sink (as directed by
engineer incharge) at required position etc complete.
Providing and laying coloured glazed tiles of the size
1200 mm x 600 mm x 8 mm in skirting, risers of steps
25 and dedo on 10 mm. thick cement plaster 1:3 (1 229.08 Smt 1523.67
cement : 3 coarse sand) & jointed with white cement
P & L 48" x 24" vitrified 8 mm thick tile flooring over
mm (average) base of cement mortar 1:6 ( 1 cement:
6 coarse sand) on new surface or fixing on existing
26 flooring by adhesive material including dismentaling of 400.21 Smt 1472.92
existing flooring and jointed with color cement slurry
including finised with flush pointing & cleaning the
surface etc. complete for antiskid
1) Contractor shall correlate all services drawings
from different installers and prepare a clash free
shop drawing as per the architectural drawings
for RCP, with all services integrated, vis a vis
HVAC, FFTG, PLUMBING, ELE, ELV & any other
services planned and part of the design.
2) The method statement for execution of all
services coordinated with the ceiling execution
shall be submitted by the Contractor for approval
of the Engineer-in-charge before commencing
execution work at site.
3) Quality check and sequence of execution along
with relevant documentation to be ensured by the
site project team for inspection and quality
4) The false ceiling work to be strictly supervised
for alignment, line & level and overall quality of
installation and the Contractor to strictly follow
the approved methodology statement.
5) The false ceiling suspension work shall be
strictly from the mother slab or secondary
supports installed for the false ceiling and not
from any suspension members of other services.
6) All services equipment & light fixtures, curtains
etc. to be fixed with a separate suspension
system from the mother slab, not on the false
ceiling tiles or false ceiling members.
7) For gypsum ceilings, the Contractor shall
provide perimeter channels at the periphery of all
services cutouts for strengthening the system.
8) If required, additional supports to be provided
for fixing the false ceiling (in case of special
shape, more height etc).
9) In case the height of suspension system is
more than what is recommended by the
manufacturer, separate MS supports to be
provided from the mother slab and the false
ceiling to be suspended from the MS supports.
Design and shop drawing for the MS fabrication
work and connections with the structure members
shall be submitted by the Contractor for approval
by the Engineer-in-charge. MS framework to be
designed to accommodate other services, if
required. Such MS frame work shall be paid under
relevant Tender items.
10) The sequence of execution of the different
services to be aligned with the RCP to avoid any
11) Movement joints/groove to be provided in the
boards or grid ceiling system in large span areas.
12) Contractor to quote the rate considering all
points mentioned in the specifications.
Providing and fixing eco-friendly light weight calcium
silicate false ceiling tiles having Tegular edge &
mm Thick Densified edges on the Tile Periphery for
Extra Strength The Light weight calcium silicate
ceiling tiles shall have , light reflection 85%
non-combustible as per B.S. 476 part IV, 100%
humidity resistance and also having thermal
conductivity0.043° w/m KC.for the best thermal
Insulation . The Light weight calcium Silicate tile shall
be of approved texture Fine fissured/
Spintone/Cosmos having NRC value of 0.5 & Globe
having NRC value of 0.75 NRC or equivalent of size
595 X 595 mm to be laid on true horizontal level
suspended inter locking metal grid of hot dipped
galvanized steel sections (galvanizing @120 grams
per sqm including both side) consisting of main ‘T’
runner suitably spaced at joints to get required length
and size of 24X38mm made from 0.30 mm thick
(minimum) sheet, 1200mm centre to centre, and
cross ‘T’ of size 24X28mm made out of 0.33mm
(Minimum) sheet spaced 1200mm along spaced
between main ‘T’ at 600mm centre to centre to form
agrid of 1200X600mm and secondary cross ’T’ of
length 600mm and size 24x28mm made of 0.30 mm
thick (Minimum) sheet to be interlocked at middle of
the 1200X600mm panel to form grid of size
600X600mm resting
on periphery walls/partitions on a perimeter wall angle
pre-coated steel of size (24X24X3000mm made of
0.40mm thick (minimum) sheet with the help of rawl
plugs at 450mm centre to centre with 25mm long dry
wall screws @ 230mm interval and laying 15mm thick
Densified edges light weight calcium silicate ceiling
tiles of approved texture (Fine
Fissured/Cosmos/Spintone) in the grid including,
cutting /making opening for services like diffusers,
grills, light fittings, fixtures, smoke detectors etc.,
wherever required, Main ‘T’ runners to be suspended
from ceiling using G.I. slotted cleats of size
25X35X1.6mm fixed to ceiling with 12.5mm dia and
50mm long dash fasteners, 4mm G.I. adjustable rods
with galvanized steel level clips of size
85X30X0.8mm, spaced at 1200mm
centre to centre long main ‘T’ bottom exposed with
24mm of all T-sections shall be prepainted with
polyester baked paint, for all heights, as per
specifications, drawings and as directed by
engineer-in-charge.Note:- Only calcium silicate false
ceiling area will be measured from wall to wall. No
deduction shall be made for exposed frames/opening
(cut outs) having area less than 0.30 sqm. The
calcium silicate ceiling tiles shall have NRC. Value of
0.50 (Minimum) for Fine fissured/Spintone/Cosmos
and 0.75 NRC for Globe, light reflection 85%
non-combustible as per B.S. 476 part IV, 100%
humidity resistance and also having thermal
conductivity. 0.043° w/m KC.for the best thermal
Providing and fixing gypsum board false ceiling
consists at G.I perimeter channels of size 0.55 thick
having one flange of 20 mm and another flange of
mm and web of 27 mm along with perimeter of ceiling,
screws fixed to brick work / concrete / partition with
help of nylon sleeves and screws at 610 mm centre.
The suspending G.I. intermediate channels of size
mm(0.9 mm thick with 2 flangs at 15mm each from
the soffit at 1220 mm centrewith ceiling angles of
width 25mm x 10mm x 0.5 mm thick fixed to soffit
withG. I cleat and steel expansion fastners ceiling
section of .55 thick having kurled web 51.5 mm and
flangs at 26 mm each with lip at 10.5 mm are fixed to
intermediate channel with help of connecting clips and
in direction perpendicular to the intermediate channel
at 450mm centre to centre including 12.5 mm tapered
edge Gyp board conforming to IS 2095 – 1982 is then
screw fixed to ceiling section with 25mm dry wall
screws of approved quality and make at 230mm
centre, screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges at the cupboard are to be joint and finished so
as to have a flush look which includes filling and
finishing with jointing compound, paper tape etc.
complete. Rate to be included all kinds of profiles,
upright, curves,cutouts required for light fixtures,
speakers, sprinklers, smoke detectors, trap doors,
A.C. grill, diffuser etc including additional support if
required of duct portion, marking grid on ceiling,
including all drops, offsets, curvature small moulding
and in desired geometrical pattern, including 2 coats
of primer, plaster putty and minimum 3 coats of plastic
Emulsion paint as per manufactures specification,
scaffolding. Note:-As per drawings and design
supplied by architect and instruction given by
authority and E.I.C.
Providing and fixing moisture proof Calcium Silicate
Board false ceiling consists at G.I perimeter channels
of size 0.55 thick having one flange of 20 mm and
another flange of 30 mm and web of 27 mm along
with perimeter of ceiling, screws fixed to brick work /
concrete / partition with help of nylon sleeves and
screws at 400 mm centre. The suspending G.I.
intermediate channels of size 45 mm(0.9 mm thick
with 2 flangs at 15mm each from the soffit at
mm centrewith ceiling angles of width 25mm x 10mm
x 0.5 mm thick fixed to soffit withG. I cleat and steel
expansion fastners ceiling section of .55 thick having
kurled web 51.5 mm and 2 flangs at 26 mm each with
lip at 10.5 mm are fixed to intermediate channel with
help of connecting clips and in direction perpendicular
to the intermediate channel at 450mm centre to
centre including 8 mm tapered edge alcium Silicate
Board conforming to IS 8154 – 1993 is then screw
fixed to ceiling section with 25mm dry wall screws of
29 approved quality and make at 200mm centre, screw 53.86 Smt 1254.71
fixing is done mechanically with drilling machine with
suitable attachment. Finally tapered edges at the
cupboard are to be joint and finished so as to have a
flush look which includes filling and finishing with
jointing compound, paper tape etc. complete. Rate to
be included all kinds of profiles, upright,
curves,cutouts required for light fixtures, speakers,
sprinklers, smoke detectors, trap doors, A.C. grill,
diffuser etc including additional support if required of
duct portion, marking grid on ceiling, including all
drops, offsets, curvature small moulding and in
desired geometrical pattern, including 2 coats of
primer, plaster putty and minimum 3 coats of plastic
Emulsion paint as per manufactures specification,
scaffolding. Note:-As per drawings and design
supplied by architect and instruction given by
authority and E.I.C.
1) Rate shall be inclusive of any type of groove
and drip mould in all type of plaster work.
2) The rate shall be for all height, all level in any
3) Curing method shall be approved by Engineer
4) Contractor shall provide mesh/ natural fibres
i.e. jute, core at junctions, corners, surround
electrical cut-out, services chiselled area etc.
5) Engineer incharge reserves right to reject part
or all work of sub standard or not in confirmation
to sample approved/or not as per mock up and in
such case contractor required to re do the same
work confirming with approved sample/mockup
without any extra cost. Sample and mock shall not
be payable if rejected or casted in other location
(not in scope of work area).
6) In all plaster work, chicken mesh shall be
provided at the junctions of masonry and
concrete works to prevent cracks. The mesh shall
be properly fixed and embedded before
plastering, and the finishing shall be done smooth
and even, as per the instructions of the
Engineer-in-Charge. (The cost of providing and
fixing chicken mesh shall be paid separately as
per the relevant tendered item rate.)
7) Only the following approved brands of cement
shall be used for all works: [ultratech], [sanghi],
[Siddhi], [Hathi] and [Ambuja]. Use of any other
brand shall not be permitted without prior written
approval of the Engineer-in-Charge.
Providing throating or plaster drip and moulding to
R.C.C. Chhajja.
31 Provideing & fixing Chicken wire mesh with plaster 100.00 Smt 184.03
Providing 10mm thick cement plaster in single coat on
brick/concrete walls for interior plastering upto floor
two level and finished even and smooth in (i)Cement
mortar 1:3 (1-cement:3-sand)
Providing 15mm thick cement plaster in single coat on
Rough (Similar)side of single or half brick walls for
33 interior plastering upto floor two level and finished 944.50 Smt 176.15
even and smooth in (ii) Cement mortar 1:4 (1-cement
20mm thick mala / sand faced cement plaster on
walls upto height 10 metres above ground level
34 consisting of 12mm thick backing coat of C.M. 1:3 737.87 Smt 350.58
(1-cement : 3-sand) and 8mm thick finishing coat of
C.M. 1:1 (1-cement : 1-sand) etc. complete.
1) Contractor shall prepare shop drawing base on
concept design/ drawing for any type of
fabrication work and get approved. Contractor
shall prepare mock-up/ prototype (as suggested)
as per approved shop drawing for approval. Work
shall be carried out as per approved shop
drawing, approved mock-up/ prototype and as
suggested by Engineer in charge.
2) Rate shall be for all floor, all level all height.
3) The rate shall include cost of all types of
fasteners (ETA approved) to be used for fixing.
4) Structural stability shall be responsibility of
contractor for all kind of metal work.
5) All elements shall be factory fabricated and
finished, only final finishing to be made on site
with all precautions.
6) Contractor shall coordinate all services work
(cut-outs and provisions) in metal work. All
cut-out and services provisions shall be finished
at factory/ work shop.
7) Contractor shall provide PVC/ nylon separator,
where two different metals connect to avoid
galvanic reactions.
Providing, fabricating, assembling, hoisting/ erecting
and fixing in position at all heights/ all shapes & sizes
with all leads & lifts using MS Rolled Steel Sections,
Hollow sections, MS Plates/ sheet, Flats, Bright Bars,
Anchor bar, deep threaded MS bolts, threaded J bolts,
insert plate, support plate etc as per drawing and all
confirming to latest relevant IS codes for steel
structures like staircases, railings, handrail, pergola,
decorative gate, grills, platforms, brackets, monkey
ladder or similar etc. including straightening, cutting,
bending, bolting and welding the members,
scaffolding/ staging etc. complete and comprising of :
i) Profile Cutting of components to required length/
width and shape/ profile;
ii) Smooth grinding/ machining of edges/ faces/ all
welding joints;
iii) Necessary welding (electric arc welding) in
35 required weld length and size; 3596.80 Kg 103.57
iv) Machine drilling of holes for joining/ anchoring
Standard measurements will be paid for as actual cut
length used at site. The rate shall include dry sanding,
degreasing (wet cleaning) & preparation of rust free
surface manually or mechanically, metal putty to make
the surface even and smooth, 2 coat zinc chromate
yellow oxide primer and 2 coat of enamel paint of
approved make, shade and finish over all the surfaces
of the steel sections.
Note: The contractor shall be submit shop/ fabrication
drawings based on construction drawings for approval
from the Architect and Engineer in charge. The
fabrication work shall start only after approval of the
fabrication drawings submitted by contractor.
Fabrication shall be in a perfect architectural
workmanship manner and as provided in section V &
1) Paint shall be applied after thoroughly brushing
the surfaces, free from mortar dropping and other
foreign matter, preparing the surface even and
sand papered smooth etc, after applying every
coat of putty and primer complete.
2) If necessary more coats shall be applied till the
surface presents a uniform appearance without
any extra cost.
3) Paint shall be applied with any means (i.e.
brush, roller, spray etc)
4) Contractor shall prepare sample of minimum
three shades as suggested by engineer in charge
5) The rate shall be applicable for all floor, all
level, all height by any means of scaffolding.
6) emultion paint quality should be simmiler of -
asian paints premium emulsion, dulux velvet
touch, Berger Silk
7) Exterior paint shall be applied over a
waterproof primer of approved make, as directed
by the Engineer-in-Charge.
Providing and applying external finish of average 2 to
2.5mm thick acrylic polymer based texture Plaster
Terre Plaette and pattern with standard tool and
applicator as specified by manufacturer on exterior
surfaces at all heights including scaffolding to give
even shades including thoroughly brushing the
surfaces free from mortar droping and other foreign
matter and sand paper smoothed etc. complete as
per the manufacture specifications and up to the
satisfaction of Engineer in-charge/ Architect. The rate
includes making of grooves, pattas and finishing as
directed by Architect/ EIC. Paint shall be measured
and paid in seperate tender item. (Item should be
executed by approved applicator only.)
Applying two coats of putty & two coats of primer of
approved brand and manufacture on new wall surface
37 to give an even shade including thoroughly brushing 1507.69 Smt 40.60
the surface free from mortar dropping and other
foreign matter and sand papered smooth.
Wall painting (two coats) with emulsion paint of
approved brand and manufacture on undecorated
38 wall surface to give an even shade including throughly 1507.69 Smt 84.82
brushing the surface free from mortar droppings and
other foreign matter and sand papered smooth.
Finishing wall with weather proof exterior emulsion
paint on wall surface (two coats) to give an required
39 shape even shade after thoroughly brushing the 737.87 Smt 122.14
surface to remove all dirt, and remains of loose
powdered materials. etc complete
1) All the waterproofing treatment/ work shall be
executed through an approved water-proofing
agency of an approved manufacturer. The
contractor shall submit a technical data sheet of
each product, which will be used for execution.
2) The contractor shall submit a methodology
statement with all details in illustrative sketch
form and get approved by the Engineer-in-charge.
3) Waterproofing shall be executed under the
supervision of the technical team of the
manufacturer. Waterproofing shall be tested and
approved by the Engineer-in-charge before
proceeding with subsequent activities.
4) The Contractor shall repair the concrete
element by injection grouting of suitable
non-shrink grout and other suitable methods in
case of defective concreting of retaining walls,
water tanks, slabs, beams, etc., for which nothing
extra shall be payable.
5) Rate shall be inclusive of surface preparation,
repairing, injection grouting, saw cutting of
construction joints and filling with patch repair
mortar, making polymer mortar /Polymer CC fillets
at horizontal as well as vertical corners, etc
complete. The rate shall be inclusive of testing of
elements and system before and after
waterproofing application.
6) The latest technical system/ product shall be
adopted at the time of execution.
Providing and laying water proofing treatment on
roofs of slabs by applying cement slurry mixed with
water proofing cement compound consisting of
(a) after surface preparation, first layer of slurry of
cement @ 0.488 kg/ sqm mixed with water proofing
cement compound @ 0.253 kg/sqm.
(b) laying second layer of Fibre glass cloth when the
first layer is still green. Overlaps of joints of fibre cloth
should not be less than 10 cm.
40 (c) third layer of 1.5 mm thickness consisting of slurry 563.19 Smt 695.79
of cement @ 1.289 kg/sqm mixed with water proofing
cement compound @ 0.670 kg/sqm and coarse sand
@ 1.289 kg/sqm. This will be allowed to air cure for
hours followed by water curing for 48 hours. The
entire treatment will be taken upto 30 cm on parapet
wall and tucked into groove in parapet all around.
(d) fourth and final layer of china mosaic (which will
be paid for separately.
For the purpose of measurement the entire treated
surface will be measured.
Providing and laying broken chine mosaic flooring for
terrace using 12 mm to 20 mm broken pieces of
glazed tiles to be laid over cement mortar 1:3 to plain
or slope and to be tempered to bring mortar creme
out upto surface using white cement including
rounding off junctions and extending them upto 15 cm
along the wall, clearing with water and oxalic acid etc.
Providing and fixing 25 mm thick decorative polyester
acoustic wall panels, manufactured from 100%
polyester fibre, having density in the range of
100–240 kg/m³ (±10%), of approved colour, texture,
pattern and finish, with square/bevelled/mitred edges
as required. The 25 mm thick acoustic panel shall
have NRC 0.70 (without air gap), with sound
absorption coefficients approximately 0.07 at 125 Hz,
at 2000 Hz and 0.98 at 4000 Hz. Panel shall have
42 Class ‘A’ Fire Rating as per ASTM E-84 Tunnel Test. 112.56 Smt 2951.67
Panels shall be fixed directly onto the prepared
wall/substrate using manufacturer-recommended
adhesive, including necessary cutting to required
sizes/patterns, making openings for
electrical/services, edge finishing, proper joint
alignment, adhesive, wastage, scaffolding, labour,
tools and all necessary accessories, complete as per
approved drawings, manufacturer's specifications and
directions of Engineer-in-Charge. includeing plywood
Providing, supplying, installing, testing and
commissioning of decorative wall-mounted cascading
water fountain/water feature, comprising SS-304
water distribution channel/weir for uniform sheet flow
of water over approved stone/tile finished wall
surface, bottom water collection trough/tank with
complete waterproofing treatment, suitable
43 recirculation pump, filter/strainer, UPVC/PVC suction 1.00 Each. 89667.80
and delivery piping, valves, fittings, drainage/overflow
arrangement, waterproof LED illumination, electrical
connections, necessary supports, fasteners and
accessories, including cutting, fixing, plumbing, wiring,
testing and commissioning, complete in all respects
as per approved design and directions of
Engineer-in-Charge.
1) All natural stones shall be free from cracks,
lines, stains, and white spots of efflorescence,
and even in shade for all kinds of stonework.
2) All natural stones shall be selected and sorted
for uniform colour, figure, and thickness and
approved by Engineer-in-charge prior to
3) All natural stones shall be from the same lot
and/ or source (stone quarry) for the same kind of
work to avoid shade variation and as approved by
the Engineer-in-charge.
All types of loose and laid samples of flooring
shall be approved by the Engineer-in-charge.
The contractor shall apply approved Stone
Impregnation primer/ sealer coat on both sides
and all edges (after cutting and finishing the stone
as per size) of stones in a minimum of two coats
as per the manufacturer's specification and as
directed by the Engineer-in-charge. No extra shall
be paid for the same.
4) Contractor shall co-ordinate and execute for all
services in flooring and wall lining/ cladding work
i.e. making openings/ cut-outs for any services
(i.e. elevator operating panel in lift wall cladding,
raceway in flooring, junction box, etc), and
making good as per the satisfaction of
Engineer-in-charge.
5) Flooring and wall cladding/ lining work shall be
carried out for all floors, all levels, all heights, and
6) Rate shall be inclusive of all types of wastage
of all material.
7) Only the following approved brands of cement
shall be used for all works: [ultratech], [sanghi],
[Siddhi], [Hathi] and [Ambuja]. Use of any other
brand shall not be permitted without prior written
approval of the Engineer-in-Charge.
Providing and laying Polished Rajula slat stone work
on wall top / flooring in required colour, design and
patterns, in linear as well as curvilinear portions all
complete as per the architectural drawings with
mm thick stone slab over 20 mm (average) thick base
44 of cement mortar 1:4 (1 cement : 4 coarse sand) laid 1.00 Smt 2613.60
and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching
shade including rubbing, curing and polishing etc. all
complete as specified and as directed by the
Engineer-in-Charge.
Providing and fixing Rajula slat stone work (polished
and machine cut) of thickness 20 mm for wall lining
(veneer work) in linear as well as curvilinear portions,
backing filled with a grout of average 12 mm thick in
45 cement mortar 1:3 (1 cement : 3 coarse sand), 1.00 Smt 4563.03
including pointing with white cement mortar 1:2 (1
white cement : 2 stone dust) with an admixture of
pigment to match the stone shade etc. all complete as
specified and as directed by the Engineer-in-Charge.
1) Pipes and fittings shall be ISI marked and of
2) Pipes & fittings shall be of specific brands like
Supreme Industries Ltd, Prince Pipes & Fittings
Ltd, Finolex Industries Ltd, Astral Limited and
other similer brands as per approval of
Engineer-in-Charge.
3) Valves, cocks, traps and fixtures shall be of
standard quality and as per Engineer-in-Charge’s
4) All pipelines shall be laid true to line, level, and
properly supported.
5) Concealed lines shall be pressure-tested before
plastering/ finishing.
6) Traps and fittings shall be fixed with proper
alignment and water seal.
7) Openings and chases for pipes shall be made
good after installation.
8) Water supply lines shall be hydraulically tested
to required pressure.
9) All rates shall be inclusive of material, labour,
scaffolding, cutting, chasing, testing, and making
10) Work shall be carried out strictly as per
manufacturer’s instructions and direction of
Engineer-in-Charge.
Providing and fixing wash down wall mounting
EWC-P of approved shade, conforming to Pattern 2 of
IS: 2556 (Part -II), with SWR Self it Soil PVC pipe and
plug bend as per specifications; glazed vitreous /
Coloured European Water Closet with Metropole flush
valve, connecting PVC 110mm dia soil pipe with PVC
coupling, nuts, Ragbolt, Gasket Fitiiing and solid
46 verity heavy duty plastic seat cover as per IS-2548, of 8.00 Each 17405.03
approved make; hole in walls/slab/beam and making
good etc. complete as per directed by the Engineer's
Representative.
W.C Wall Hung : Jaquar, Model No. :
CNS-WHT-963UFSM
Metropole flush valve : Jaquar, Model No. :
Providing and fixing in position 15 mm C.P. brass bib
cock of best quality including cutting and making good
47 the wall where required etc. complete as per directed 8.00 Each 2624.08
by the Engineer's Representative.
Bib Cock : Jaquar, Model No. : OPP-CHR-15037PM
Providing and fixing 15mm C.P. brass angle valve with
wall flange complete, including cutting and making
48 good the wall where required etc. complete as per 8.00 Each 1737.30
directed by the Engineer's Representative.
Angle Valve :Jaquar, Model No. : OPP-CHR-15053PM
Providing and fixing of Hand Shower (Health Faucet),
with 8mm Dia,1Rmt Long pvc Tube and Wall Hook
49 accessories to .complete the item etc. complete as 8.00 Each 1838.68
per directed by the Engineer's Representative.
Health Faucet :Jaquar, Model No. : ALD-CHR-565
Providing and fixing White glazed vitreous Oval Wash
Basin WALL HUNG, size 560x430x195 mm., with
supporting M.S. or C.I. Brackets, necessary pipe
connection up to the outside face of the wall, Waste
coupling 32 mm size full thread with 80 mm height
Chrome plated, Bottle trap Chrome plated
Pressmatic Pillar Cock including necessary fittings
50 with wall Flange etc. complete in all respects including 8.00 Each 8746.74
cutting and making good the walls etc. complete as
per directed by the Engineer's Representative.
Wash basin : Jaquar, Model No. : CNS-WHT-811
Waste coupling : Jaquar, Model No. :
ALD-CHR-705L130
Bottle trap : Jaquar, Model No. :
ALD-CHR-769L300X190
Providing and fixing of C.P. copper connecting pipe
450 mm long and nuts, washer and brass flange
complete, including cutting and making good the wall
51 where required etc. complete as per directed by the 8.00 Each 459.55
Engineer's Representative.
Braided Hose Copper Pipe : :Jaquar, Model No.
Providing and fixing Pressmatic Pillar Cock of best
quality necessary fittings with wall Flange etc.
complete in all respects including cutting and making
52 good the walls etc. complete as per directed by the 8.00 Each 2772.91
Engineer's Representative.
Pressmatic Pillar Cock : Jaquar, Model No. :
Providing and fixing Long Body Bib Cock with Wall
Flange best quality including cutting and making good
the wall where required etc. complete as per directed
by the Engineer's Representative.
Long Body Bib cock : Jaquar Continental, Model No:
OPP-CHR-15037PM
Providing and fixing white vitreous china flat back
Urinal of size 385x325x635mm as per IS-2556
(Part-2) with C.I. hangers and pipe to wall with C.P.
flange with AUTO CLOSING CONCEALED Type
Urinal flush valve, complete including cutting and
54 making good the walls wherever required etc. 5.00 Each 14069.45
complete as per directed by the Engineer's
Representative.
Urinal :Jaquar, Model No. :URS-WHT-13253N
Urinal Flush valve ,Jaquar, Model No. :
Providing and fixing in position best Indian make toilet
recessed type paper holder complete in all respects
including cutting and making good the walls etc.
55 complete as per directed by the Engineer's 8.00 Each 1585.84
Representative.
Toilet Paper Holder : Jaquar, Model No.
Providing and fixing in position best Indian make C.P.
brass twin way QUOTE and hat hooks fixed into wall
with C.P. Brass screws and rawlplugs etc. complete
including cutting and making good the walls etc.
complete as per directed by the Engineer's
Representative.
Twin Way coat Hook: Jaquar, Model No.
Providing and fixing electrical hand dryer, fully
automatic type etc. complete as per directed by the
Engineer's Representative.
Hand Dryer : Jaquar, Model No. :HDR-SSF-AK2803D
Providing and fixing C.P. brass liquid soap container
of best quality etc. complete as per directed by the
58 Engineer's Representative. 6.00 Each 1433.76
Liquid Soap Container : Jaquar, Model No. :
SDR-WHT-DJ0010F
Providing and fixing of 2 way Single Lever Diverter
Mixer including of Concealed Fitting with Built in Non
return Valve , concealed stop cock for hot and cold
water supply controlling with Diverter Handle with
Spout and overhead shower etc. complete as per
directed by the Engineer's Representative.
Diverter, Make : Jaquar, Model :
59 KUP-CHR-35065NKPM 2.00 Each 15317.99
Concealed body for Diverter : Jaquar, Model :
Shower head, Make : Jaquar, Model :
Shower arm, Make : Jaquar, Model :
SHA-CHR-455L400
Spout, Make : Jaquar, Model : SPJ-CHR-35429PM
Providing & fixing stainless steel recessed type soap
dish of approved make. Including providing & fixing
screws, washers, cutting & making good the walls etc.
complete as per directed by the Engineer's
Representative.
Soap Dish : Jaquar, Model No. : ACN-CHR-1131N
Providing and fixing towel rail of approved make
including, providing and fixing C.P. brass screws,
61 making holes in walls and making good etc. complete 2.00 Each 1560.49
as per directed by the Engineer's Representative.
Towel Rail : Jaquar, Model No. : ACN-1111BNM
Providing and fixing of Handicap toilet cruse set
complete set including EWC, Flushing cistern, soft
close seat cover, twin flush fitting, Washbasin, single
lever basin mixture, wall mounted grab bar, wall
mounted hinged handrail, bottle trap including jointing
62 the trap with soil pipe in cement mortar 1:1 (1 cement 1.00 Each 50335.37
: 1 fine sand) including providing and fixing plastic
seat cover for wash down W.C. with C.P. brass hinges
and rubber buffers white plastic seat and jet spray
including cutting holes in walls and making good etc.
complete as directed by Engineer In Charge.
Providing and fixing 600mm x 450mm bevelled edge
mirrror of superior glass mounted on 6mm thick A.C.
sheet or plywood sheet and fixing to wooden pluge
with C.P. brass screws and washers.
Providing and fixing brass screw down stop tap.(A)
Providing and fixing brass screw down stop tap.(B)
Providing and fixing brass screw down stop tap.(C)
Providing and fixing Gun metal check or non-return
fullway wheel valve.(A) 15mm dia.
Providing and fixing Gun metal check or non-return
fullway wheel valve.(B) 20mm dia.
Providing and fixing Gun metal check or non-return
fullway wheel valve.(C) 25mm dia.
Providing and fixing Gun metal check or non-return
fullway wheel valve.(D) 32mm dia.
Providing and fixing Gun metal check or non-return
fullway wheel valve.(E) 40mm dia.
Providing and fixing C.I. Manhole cover 0.60 M. x
0.45M. size having weight not less than 35Kg.
Providing and fixing cast iron steps of size 500mm x
73 150mm x 22.5mm and painting with two coats of 0.00 Each 155.11
Anti-corrosive paint etc. complete.
Providing and fixing concealed center point to wall
ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for potable
water of following dia. nominal bore tube fittings and
clamps including making good the wall, ceiling and
floor etc. complete.[A] 15 mm.
Providing and fixing concealed center point to wall
ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for potable
water of following dia. nominal bore tube fittings and
clamps including making good the wall, ceiling and
floor etc. complete. [B] 20 mm.
Providing and fixing concealed center point to wall
ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for potable
water of following dia. nominal bore tube fittings and
clamps including making good the wall, ceiling and
floor etc. complete. [C] 25 mm.
Providing and fixing concealed center point to wall
ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for potable
water of following dia. nominal bore tube fittings and
clamps including making good the wall, ceiling and
floor etc. complete. [D] 32mm.
Providing and fixing concealed center point to wall
ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for potable
water of following dia. nominal bore tube fittings and
clamps including making good the wall, ceiling and
floor etc. complete. [E] 40mm.
Providing and fixing concealed center point to wall
ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for potable
water of following dia. nominal bore tube fittings and
clamps including making good the wall, ceiling and
floor etc. complete. [F] 50mm.
Providing and fixing Gun metal check or non-return
fullway wheel valve.(C) 25mm dia.
Providing and fixing Gun metal check or non-return
fullway wheel valve.(E) 40mm dia.
Providing, laying and jointing in true line and level
diametre U.P.V.C (Type B) conforming to IS
13592-1992 with one end plain and other end
socketed with rubber ring, & fittings conforming to ISI
14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with
rubber lubricant, pipe shall be fixed on wall using of
PVC clamp of the size 160 mm diametre x 210 mm
length x 196 mm heigh at every 2000 mm center to
center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc.
including testing of pipes and joints and jointed with
adhesive solvent cement including cost of all
Providing, laying and jointing in true line and level
diametre U.P.V.C (Type B) conforming to IS
13592-1992 with one end plain and other end
socketed with rubber ring, & fittings conforming to ISI
14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with
rubber lubricant, pipe shall be fixed on wall using of
PVC clamp of the size 110 mm diametre x 149 mm
length x 145 mm heigh at every 2000 mm center to
center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc.
including testing of pipes and joints and jointed with
adhesive solvent cement including cost of all
Providing and fixing PVC SWR Nahni trap IS
for drain - 100 mm diameter with jali of the following
84 nominal diameter of self cleansing design with C.I 15.00 Each 600.24
scread down or hinged grating including the cost of
cutting and making good the walls.
Providing erecting and fixing double coated ISI water
85 tank of required capacity each with all necessary 35000.00 Ltr 3.95
fitting and connection etc. complete on terrace
Providing and fixing ball cock of approved. quality as
directed.(A) Copper Metal (i) 25mm dia.
Providing and fixing ball cock of approved. quality as
directed.(A) Copper Metal (ii) 50mm dia.
Providing and fixing S.W. gully trap with C.I. grating
brick masonry chamber and water tight C.I. cover with
88 frame of 300mm x 300mm size (inside) with standard 12.00 Each 1292.20
weight.(i) Square mouth traps. (A) 100mm x 100mm
Providing laying (to level or slopes) and jointing
reinforced concrete Light duty non-pressure pipes I.S.
89 class NP2 of the following internal diameter with 35.00 Rmt 444.62
collars and butt ends prepared for collar joints
including testing of joints complete. (D) 300mm
Providing laying (to level or slopes) and jointing
reinforced concrete Light duty non-pressure pipes I.S.
90 class NP2 of the following internal diameter with 25.00 Rmt 805.45
collars and butt ends prepared for collar joints
including testing of joints complete. (E) 450mm
Constructing Manhole with R.C.C. top slab in 1:2:4
mix (1-cement :2-coarse sand : 4-graded stone
aggregate 20mm nominal size) foundation concrete
1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats
+ 50mm size) inside plastering 15mm thick with
Cement Mortar 1:3 (1-Cement : 3-coarse sand)
finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix
(1-Cement :2-Coarse sand :4-stone aggregate 20mm
91 nominal size) finished smooth complete including 4.00 Each 11029.97
curing and festing (i) Inside size 900mm x 1200mm
and 1.5M. deep including C.I. cover with frame size
560mm diameter total weight of cover and frame to be
not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of
frame 64 Kg.)(A) With 230mm thick walls of brick
msonry using brick having crushing strength not less
than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1-
Cement: 5-Coarse sand) (1) A type depth 0.90 Metre
for 150mm diameter sewer.
Constructing Manhole with R.C.C. top slab in 1:2:4
mix (1-cement :2-coarse sand : 4-graded stone
aggregate 20mm nominal size) foundation concrete
1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats
+ 50mm size) inside plastering 15mm thick with
Cement Mortar 1:3 (1-Cement : 3-coarse sand)
finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix
(1-Cement :2-Coarse sand :4-stone aggregate 20mm
92 nominal size) finished smooth complete including 5.00 Each 19349.64
curing and festing (i) Inside size 900mm x 1200mm
and 1.5M. deep including C.I. cover with frame size
560mm diameter total weight of cover and frame to be
not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of
frame 64 Kg.)(A) With 230mm thick walls of brick
msonry using brick having crushing strength not less
than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1-
Cement: 5-Coarse sand) (2) B type depth 1.50 Metre
for 150mm diameter sewer.
Constructing brick masonry chamber for underground
C.I. Inspection chamber and bends with bricks having
crushing strength not less than 35Kg/Cm2 in C.M. 1:5
C.I. cover with frame (Light duty) 455mm x 610mm
intenal dimensions total weight of cover with frame to
be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt.
of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix
(1-cement :2- coarse sand :4-graded stone aggregate
20mm size) foundation concrete 1:5:10 inside plaster
15mm thick with cement mortar 1:3 finished smooth
with a floating coat of neat cement on walls and bed
concrete etc. complete.(ii) Inside dimensions 500mm
x 700 mm and 450mm deep for pipe line with one or
Providing and laying (to level or slopes) and jointing
with stiff mixture of
94 Cement Mortar in proportion 1:1 Salt glazed 15.00 Rmt 211.58
stoneware pipes including
testing of pipes and joints complete.(A) 100mm dia.
Providing and laying (to level or slopes) and jointing
with stiff mixture of
95 Cement Mortar in proportion 1:1 Salt glazed 30.00 Rmt 305.14
stoneware pipes including
testing of pipes and joints complete.(B) 150mm dia.
Providing and laying Cement concrete 1:5:10
(1-Cement : 5-Fine sand :10- Graded stone aggregate
40mm nominal size) bedding for stoneware pipes of
following internal diameters with necessary formwork
and curing complete.(A) 100 mm dia. (112 mm
Ave.bed thickness)
Providing and laying Cement concrete 1:5:10
(1-Cement : 5-Fine sand :10- Graded stone aggregate
40mm nominal size) bedding for stoneware pipes of
following internal diameters with necessary formwork
and curing complete.(B) 150mm dia. (166mm Ave.
Supply, Installation, Testing and Commissioning of
Electric driven fire pump suitable for
automatic/manual operation and consisting of
following: complete in all respect as required.
(a) Monoblock pump to ensure a minimum pressure
of 3.5 kg / sq.cm. at highest and farthest outlet at
specified flow of 900 lpm at 65 m. head conforming to
Supplying, Installation, Testing and Commissioning of
Control Panel suitable for automatic/manual operation
of fire fighting pumps consisting
(a) Necessary cabling, wiring, earthing frompanel to
individual equipment shall be included in the quoted
(b) Facility for more selections i.e auto or manual.
(c) Protection failure and control cabling.
(d) interlocking of pressure switch with pumps
(e) soft starter
Supply, Installation, Testing and Commissioning of
150 mm dia Pressure Gauge of range 0-16 Kg/cm²
conforming to IS-3624 having bourdon tube of
stainless steel 310 in cast aluminium, stove
enameled, black, weather proof case with outer,
screwed aluminium bezel and complete with
necessary U-type stainless steel siphon tube and
cock including providing suitably painted angle iron
support to the tube etc. as per specification complete
Supply, Installation, Testing and Commissioning of the
following sizes of flange jointed / screwed / welded,
M.S Pipes of Class C (Hevy class) ISI marked
including accessories such as MS bracket, U clamps
with Anchor fasteners, tees / elbows / reducers /
101 couplings / unions / bends / flanges etc., and laying 45.00 Rmt 1674.89
on the surface including painting with one coats of
anticorrosive primer and one coats of approved red
enamel paint after laying and testing after Installation
etc. as per specifications complete as required.
(a) 100 mm dia.
Supply, Installation, Testing and Commissioning of the
following sizes of flange jointed / screwed / welded,
M.S Pipes of Class C (Hevy class) ISI marked
including accessories such as MS bracket, U clamps
with Anchor fasteners, tees / elbows / reducers /
102 couplings / unions / bends / flanges etc., and laying 6.00 Rmt 1152.21
on the surface including painting with one coats of
anticorrosive primer and one coats of approved red
enamel paint after laying and testing after Installation
etc. as per specifications complete as required.
Supply, Installation, Testing and Commissioning of the
following sizes of flange jointed / screwed / welded,
M.S Pipes of Class C (Hevy class) ISI marked
including accessories such as MS bracket, U clamps
with Anchor fasteners, tees / elbows / reducers /
103 couplings / unions / bends / flanges etc., and laying 2.00 Rmt 365.88
on the surface including painting with one coats of
anticorrosive primer and one coats of approved red
enamel paint after laying and testing after Installation
etc. as per specifications complete as required.
Supply, installation, testing and commissioningof C.I.
Butterfly valve (PN1.6) with flanges, nut bolts, gaskets
complete as required.
(a) 100 mm dia.
Supply, Installation, Testing and Commissioning of
105 NON RETURN VALVE. 1.00 Nos 6074.65
(a) 100 mm dia.
Supply, installation, testing and commissioning Single
Headed Fire Hydrant Valve with 80 mm N.B. flanged
inlet, 63 mm dia female instantaneous outlet type.
S.S.coupling, blankcap, chain, twist release type lug &
all accessories Conforming to IS:5290. Including
fixing with supports, flanged tapping from wet riser,
orifice plate complete as required by the Local Fire
Supply, Installation, Testing and Commissioning of
Weather proof Standard MS Fire Hose Cabinet wall
mounting type (450 mm x 600 mm x 250 mm deep)
having single opening with necessary locking
arrangement by allan key suitable for housing 1 no.
hosepipe, 1no. Branch pipe & nozzle spanner.
Supply, installation, testing and commissioning
non-percolating rubber reinforced lined fire Hose pipe
(as per IS:636) of 63 mm dia and 15 mtrs long. The
108 hose shall be rated for burst pressure of 35.7 1.00 Nos 5137.32
Kg/sqcm. Hose shall be complete with ISI marked SS
male & female coupling (IS:903) bound & riveted to
hose pipe with SS rivets & 1.5 mm SS wire.
Supply, Installation, Testing and commissioning of
mm dia instantaneous pattern Alluminium short
109 branch pipe, 20 mm dia nozzle conforming to IS:903, 1.00 Nos 1945.52
suitable for inter connection to hose pipe coupling
complete as required by the Local Fire Authority.
Supply, installation, testing and commissioning of First
Aid Hose Reel equipment conforming to IS:884
comprising of hose reel drum, 8 mm shut off nozzle,
110 Rubber hose reel tubing as per IS: 444 of 25 mm dia 1.00 Nos 7201.30
x 30 mtr. long, painting, Manual fix type with fixing
bracket, anchor fastener, bolts & nuts etc. complete
as required by Local Fire Authority
Supply, installation, testing and commissioning of SS
111 Ball Valve. 2.00 Nos 1800.33
Supply, installation, testing and commissioning of
Cast lron Two Way Fire Brigade Inlet as per IS:904
112 having 63 mm dia inlet with blank cap and chain with 1.00 Nos 7950.47
necessary fittings, flanges, nut bolts etc. complete as
Supply, Installation, Testing and Commissioning of
113 Gun Metal Air Release Valve with necessary fittings. 1.00 Nos 1562.22
Size: 25 mm (For Riser)
Supply, installation, testing and commissioning of
114 Pump on / off Remote switches to each internal 2.00 Nos 754.98
hydrant valve with required accessories.
Supply, installation, testing and commissioning of
XLPE insulated copper Cable from each Pump on/off
switches to Panel with all necessary accessories.
Size: 2 core 1.5 mm
Providing and fixing of Manual Fire Alarm system as
per requirement and specification consisting of
following items.
(a) Manual call point (FR-Polymer)
Providing and fixing of Manual Fire Alarm system as
per requirement and specification consisting of
following items.
(b) Hooters (FR-Polymer)
Providing and fixing of Manual Fire Alarm system as
per requirement and specification consisting of
118 following items. 55.00 Rmt 127.77
(c) Cable & other accessories: 3 C XLPE insulated
Providing and fixing of Manual Fire Alarm system as
per requirement and specification consisting of
following items.
(d) Manual Fire Alarm Panel
Supply, installation, testing and commissioning of
Carbon Dioxide (Co2) type Fire Extinguisher of 4.5 kg
120 confirm to IS:15683, with ISI marked / TAC approved 2.00 Nos 1986.17
fitted with required accessories including wall
suspension brackets.
Supply, installation, testing and commissioning of
ABC type 6 kg confirm to IS:15683, with ISI marked /
TAC approved fitted with required accessories
including wall suspension brackets.
122 Power Cablel (ALUMINIUM ARMOR) 42.00 Rmt 220.69
123 Consulting charges with documents work NOC fee 1.00 Nos 25250.00
1) All materials shall be ISI marked/ conforming to
relevant IS/ IEC standards and of approved make.
PVC pipes & accessories: Precision, BLP, Vraj or
equivalent approved.
Wires/ Cables (FRLS type): RR Kabel, KEI,
Cables (power/ control): HMT, Cable Corp,
Cablecel or equivalent.
Switchgears: Schneider, Siemens.
DB/ MCB/ RCCB: Schneider, Legrand, Hager.
Switches & accessories: Schneider, Legrand.
Light panels: Crompton, Philips.
Ceiling fans: Crompton, Usha, Havells.
Exhaust fans: Crompton, Usha, Havells.
Post-top lamps: Philips, K-Lite, Crompton.
LED flood lights: Crompton, Nissan.
Water cooler: Usha, Blue Star.
Pressure pump: Grundfos.
Cable lugs: Dowells, 3D.
2) All conduits shall be laid in proper alignment,
concealed/ surface as per Instructions, with
necessary saddles, junction boxes, bends, tees,
and inspection boxes.
3) Wiring shall be done with proper ferrules/
numbering and lugs. No loose joints/ taped
connections shall be permitted.
4) Switches, sockets, and accessories shall be
installed in flush metal boxes/ PVC boxes with
proper earthing.
5) Distribution boards shall be properly mounted,
dressed, and labelled.
6) Fans, lights, and fixtures shall be installed with
necessary supports and tested.
7) All wiring circuits shall be tested for continuity,
insulation resistance, and polarity before
8) Earthing shall be provided as per IS 3043 with
earth electrodes/ pits tested for resistance ≤
9) All equipment, DBs, panels, and circuits shall
be checked for phase sequence, load balancing,
and proper functioning.
10) Contractor shall provide test reports and
completion certificate before handing over.
11) Work shall be coordinated with other services
to avoid clashes.
12) All rates shall be inclusive of supply,
installation, testing, commissioning, scaffolding,
cutting/ chasing, and making good.
13) Entire work shall be executed as per relevant
IS standards, IE rules, and direction of
Engineer-in-Charge.
Constructing brick masonry chamber for underground
Inspection chamber and bends with bricks having
strength not less than 35Kg/Cm2 in C.M. 1:5 C.I.
frame (Light duty) 455mm x 610mm intenal
dimensions total
weight of cover with frame to be not less than 38Kg.
cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top
slabe with 1:2:4 mix (1-cement :2- coarse sand
:4-graded stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm thick with
cement mortar 1:3 finished smooth with a floating coat
of neat cement on walls and bed concrete etc.
complete.(i) Inside dimensions 455mmx 610mm and
450mm deep for single pipe line.
Providing and laying in trenches galvanised mild steel
tubes (Medium grade) of the following nominal bore,
tube fitting (Earthwork in trenches to be measured
for separately)(E) 65mm
Providing and laying in trenches galvanised mild steel
tubes (Medium grade) of the following nominal bore,
tube fitting (Earthwork in trenches to be measured
for separately)(D) 40mm
Providing and laying in trenches galvanised mild steel
tubes (Medium grade) of the following nominal bore,
tube fitting (Earthwork in trenches to be measured
for separately) (C) 25mm
Point wiring for Light / Bell with 2-1.5 sq.mm &
earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below
type of pipe erected with 6A Modular type switch /
bell push & accessories and earth continuity of
following type, erected on PVC / Metallic/Wooden
box, single mounting base frame covered with
128 textured/metallic/white front plate modules erected on 108.00 Pt. 493.89
/ in wall / ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (Green) both are of .ISI marked 1.1 KV
Grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected
with 6A Modular type switch and hum free EME step
type electronic fan regulator mounted and
accessories with earth continuity of following type
erected on PVC / Metallic/Wooden box, single
mounting base frame covered with
textured/metallic/white front plate modules erected on
/ in wall / ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling complete
Point wiring for on board Looped Plug with 6A
Modular type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate
modules erected on / in wall / ceiling with following
type accessories
Point wiring for Individual Plug with & earth wire of
1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in wall /
ceiling as per pipe erected with following type of
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu.
Wire from nearby switchboard/mcb db board
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling complete
Point wiring for Individual Plug with & earth wire of
1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in wall /
ceiling as per pipe erected with following type of
[III] For 16A Plug and 16 amp switch with 2-4 sq.mm
Cu. Wire with 2.5 sq.mm ( green) earthing wire from
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling complete
Providing and erecting Mains with 1.1 KV grade FRLS
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected concealed
in /flushed on wall/ceiling, with 1.5 sq. mm copper
133 conductor FRLS PVC insulated stranded wire of 375.00 Mtr. 90.90
green colour for earth continuity of following size
(A) With medium class Rigid PVC pipe and
(b) 2 wire 2.5 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected in / on wall
/ ceiling with 2.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth
continuity of following size
(A) with medium class Rigid PVC pipe and
(a) 2 wire 4 sq. mm
providing and erecting Mains with ISI marked, 1.5KV
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms
to IS 694, IEC - 227 erected in existing pipe of
135 following size (Specifically for control panel, relays, 50.00 Mtr. 40.40
power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if
(d) One wire 4.00 sq. mm
Providing and erecting Sheet Steel powder coated
MCB distribution board - flush / surface mounted fitted
with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
(B) three phase incoming and single phase horizontal
type outgoing Per phase isolation type (PPI)
(b) sheet steel double door
Providing and erecting Sheet Steel powder coated
MCB distribution board - flush / surface mounted fitted
with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
(B) three phase incoming and single phase horizontal
type outgoing Per phase isolation type (PPI)
(b) sheet steel double door
Providing and erecting Sheet Steel powder coated
MCB distribution board - flush / surface mounted fitted
with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
(A) single phase incoming and horizontal single phase
(b) sheet steel double door (IP-43)
Providing and erecting Sheet Steel powder coated
MCB distribution board - flush / surface mounted fitted
with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
(A) single phase incoming and horizontal single phase
(b) sheet steel double door (IP-43)
Supplying KITKAT pattern porcelain cut-out fuse with
base of following current capacity erected on existing
140 block board. 3.00 Ea. 494.90
Providing and erecting busbar chamber confirming to
IS-375 fabricated from 16 G.M.S. sheet, dust &
vermin proof having hinged door with rubber gasket
and necessary busbar supports with COPPER busbar
having current density not more than 1.6 Amp. /
sq.mm (Rated current / cross section area) duly
141 wrapped with colour insulation tape for phase 1.00 Mtr. 6761.95
sequence, three phase & neutral each suitable for
following current capacity with necessary painting
mounted on wall or pedestal frame of required size
with necessary connections.
(B) Suitable for 200 Amp. capacity
Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 35 KA. at 415 V. having normal
current rating 125A. with Fixed thermal & magnetic
142 release suitable to work on A.C.supply 50 c/s. with all 1.00 Ea. 9504.10
internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 25 KA. at 415 V,having normal current
rating up to 25 A to 100A. with Fixed thermal &
magnetic release suitable to work on A.C. supply
143 c/s. with all internal connections, spreader tinned 1.00 Ea. 7282.10
copper & complete erected in existing 16 G.M.S.
ICS=100% of ICU only Cat III
Providing and erecting Approved make RCCBs
conforming to IS: 12640 and having sensitivity of
mA and Short Circuit withstand capacity of 10 KA and
suitable for operation on 3 phase and neutral
415V,50Hz. having characteristic of quick action &
144 tripping with all advance feature & do not incorporate 3.00 Ea. 3585.50
any electronic component for following Max. rating
erected as directed.
(iii) 63 Amps. FP
Providing & erecting 415V MCB Four Pole Switch for
Lighting Load (B curve) having 10KA breaking
capacity & confirms to IS :8828 in existing box having
145 following capacity 3.00 Ea. 681.75
(a) 6 to 32 Amp.
Providing & erecting 415V MCB Four Pole Switch for
Lighting Load (B curve) having 10KA breaking
capacity & confirms to IS :8828 in existing box having
146 following capacity 2.00 Ea. 681.75
(a) 6 to 32 Amp.
Providing & erecting 240 V MCB double pole switch
for lighting Load (B Curve) having 10 KA breaking
capacity & confirms to IS : 8828 in existing box having
147 following capacity 1.00 Ea. 328.25
(A) 6 to 32 Amp.
providing and erecting Miniature circuit breaker single
pole 6A to 25A suitable to operate on 240 V A.C.
system and having breaking capacity 10 KA to be
148 erected in existing box. confirming to IS 8828/1996 100.00 Ea. 131.30
"Supplying and erecting LED indoor fittings with LEDs
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder
coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.95, THD <
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges
(A) Square/ Circular shaped Surface/Recessed Mount
Downlight with provision for spring loaded mounting
clips complete.IP20
(v) 24 watts, 12" x 12" , Surge-2 KV
"Supplying and erecting LED indoor fittings with LEDs
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder
coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.95, THD <
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
150 LED driver efficiency > 85 % 48.00 Ea. 503.99
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges
(A) Square/ Circular shaped Surface/Recessed Mount
Downlight with provision for spring loaded mounting
clips complete.IP20
(ii) 11-15 watts, Surge-2 KV
Providing & erecting Approved make Ceiling Fan with
double ball bearing ISI mark with Condenser 230 volt
A.C.50 Hz 1200 mm sweep complete having
151 blades aluminium body and blade sets having 20.00 Ea. 2727.00
ornamental design shanks , canopy erected with
earthing. [ Make shall be approved by Engineer in
Providing & erecting fresh air fan 250 mm dia with
square frame make of ABS body with louvers
"Supplying and erecting LED indoor fittings with LEDs
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and
high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor
more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
153 LED driver efficiency > 85 % 2.00 Ea. 439.35
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges
(A) Tube Light with integral driver
(iv) 22-24 Watts, Surge - 2KV,IP-20, conventional
Providing and erecting approved make split
air-conditioning unit consisting of copper condensing
unit with fan motor, hermetically sealed rotary
compressor with accessories etc. duly connected
separately erected evaporating unit and blower motor
with its accessories by means of extra supplied
154 proper insulated copper tubing,drain PVC pipes 12.00 Ea. 49540.50
suitable for ( cost includes powder coated Stand, Eco
Friendly green gas charging, 15A plug top & Remote
Control) with necessary core cutting.
(c) for 2 ton capacity
For 3 Star Rating of current year
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables
(C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
Providing and erecting XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
1.1 KV. to be laid on wall with necessary clamps or in
156 existing trench / pipe of following size of cables 10.00 Mtr. 176.75
(A) 4 core 16 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
1.1 KV. to be laid on wall with necessary clamps or in
157 existing trench / pipe at road crossing or floor of 20.00 Mtr. 793.86
following size of cables.
(A) 4 core 10 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Copper conductor
for 1.1 KV. to be laid on wall with necessary clamps
158 or in existing trench / pipe at road crossing or floor 50.00 Mtr. 597.92
of following size of cables.
(C) 4 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Copper conductor
for 1.1 KV. to be laid on wall with necessary clamps
159 or in existing trench / pipe at road crossing or floor 175.00 Mtr. 426.22
of following size of cables.
(B) 4 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Copper conductor
for 1.1 KV. to be laid on wall with necessary clamps
160 or in existing trench / pipe at road crossing or floor 375.00 Mtr. 317.14
of following size of cables.
(A) 4 core 2.5 Sq. mm
Supplying and erecting Flexible PVC insulated multi
strand multi core 1.1 kv grade ISI marked copper
wires of following size to be erected as directed.
(e) 1.50 Sq.mm 3 core round PVC sheathed
Solder less crimping type Aluminium lugs conforming
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
162 switchgear terminals with brass/cadmium plated nut 12.00 Ea. 23.23
bolts in an approved manner.
Solder less crimping type Aluminium lugs conforming
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
163 switchgear terminals with brass/cadmium plated nut 4.00 Ea. 17.17
bolts in an approved manner.
Solder less crimping type Aluminium lugs conforming
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut
bolts in an approved manner.
Solder less crimping type Aluminium lugs conforming
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut
bolts in an approved manner.
Solder less crimping type Copper lugs conforming to
IS suitable for cable of following size evenly crimped
with high pressure tool & connected to switchgear
166 terminals with brass/cadmium plated nut bolts in an 8.00 Ea. 11.11
approved manner.
Solder less crimping type Copper lugs conforming to
IS suitable for cable of following size evenly crimped
with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an
approved manner.
Solder less crimping type Copper lugs conforming to
IS suitable for cable of following size evenly crimped
with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an
approved manner.
Supplying & erecting in earthpit of minimum bore dia.
225mm size approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS
3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 80 mm having
80-200 Micron galvanising, Inner pipe dia of 40 mm
having 200-250 Micron galvanising, connection
terminal dia of 14 mm with constant ohmic value
surrounded by highly conductive compound with high
charge dissipation suitable for following type of
applications with chamber and heavy duty cover
(A)(approved make OEM has to submit test
certificate including value of earth resistance of
installation duly stamped and signed by agency and
169 officer Incharge has to ensure the value of earthing 3.00 Ea. 8370.88
resistane mentioned in test Certificate) & having back
filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as
per IEC 62561-2017, Voltage drop:- < 1 volt at no load
& dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable
to retain moisture for long time Necessary test report
must be submitted by Agency.
"[B] For Electrical installation up to 11 KV located
in other than normal soil i.e. Soft Rock, Marshy
-Length of Pipe : 2 mtr
-Back filling Compound :1 no. Bag of 25 Kg. "
Providing and erecting Annealed bare Copper wire
Providing & erecting water cooler having storage
capacity 150 Ltr. & cooling capacity 150 Ltr.per hour
@ an ambient temp of 45˚ C. The outlet temp. of the
water should drop by 15˚C within a hour, The water
cooler should be comprising of hermetically sealed
compressor, fan motor, condensing unit, water tank
surrounded by evaporating, coil, thermostats, relay
etc.complete with necessary inlet & outlet connection.
The body of water cooler will be made from Stainless
Supplying and erecting Fully Automatic hydro
pneumatic booster system with cast iron housing
Enclosure class IP44 minimum, with built in PTO
motor protection and stainless steel impeller pump,
pump model GRUNDFOS CMB 5-46 series or
equivalent with 24 Liter hydro pneumatic pressurized
tank capacity : 3.1 m3/hr,Rated head :25 mtr motor
172 rating : 1 H.P. includes pressure switches, Non Return 1.00 Ea. 35552.00
Valve, Pressure Gauge, 5 way Brass connector, with
necessary Plumbing work of 25mm dia suction and
delivery pipe which includes all required size of pipes
which includes all required size of pipes, Joints
valves, Bypass valve, labor all accessories required
for installation of pressure pump ( Foundation work
and base stand cost included)
S.I.T.C. of single phase submersible pump set
suitable for 100 mm size or more dia bore well having
motor capacity and discharge as under with
necessary panel box. Lifting and Lowering taken
(c) Motor rating 2 HP (17 stage) pump having
capacity of 106 LPM at 40 mtr head suitable for
mm dia. delivery pipe
Supplying and erecting Direct - On - Line Starter with
18 A. rating contactor and with 3.5 Amp. 18A range
directly operated in totally insulated elegant enclosure
for single phase operation up to 3 HP as per IS
174 complete erected on P.W. Block with necessary 1.00 Ea. 2477.53
Providing and, fixing heavy duty flange type brass
double compression type cable gland with rubber
ring for PVC insulated armoured cable complete with
out going tails, insulating tape etc for following size of
(A) 3 & 1/2 / 4 core 25 Sq. mm
Providing and, fixing heavy duty flange type brass
cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails,
176 insulating tape etc for following size of cables. 2.00 Ea. 54.54
(D) 2 to 4 core 16 Sq. mm
Providing and, fixing heavy duty flange type brass
cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails,
177 insulating tape etc for following size of cables. 4.00 Ea. 43.43
(B) 2 to 4 core 6 Sq. mm
Providing and, fixing heavy duty flange type brass
cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails,
178 insulating tape etc for following size of cables. 110.00 Ea. 37.37
(A) 2 to 4 core 2.5 / 4 Sq. mm
15A. 10 way bakelite connector duly erected on
existing board.
Providing & laying approved make Double walled
corrugated pipes (DWC) of polyethylene(conforming
to IS 14930 II )with necessary connecting
accessories of same material at required depth in
existing trench for laying of cable. below ground /
road surface for enclosing cable
(A)50 mm outer dia
Making trench in soft soil of suitable width of 90 cm
deep for laying cable or locating the fault all over the
run and back filling the same and making the surface
as normal ground.
Supplying & erecting Steel tubular pole (Swaged)
confirming to IS - 2713 (Part-II) 1980. Manufacturing
process of steel tubular pole should be as per IS
specification. Basic steel tube should be ISI Marked.
Pole should be painted by one coat of Zinc comet
Primer and two coat of Aluminium /approved paint to
be erected on / in existing Foundation. The length of
poles are as below.
(C) 9.0 mtr. Long Swaged Steel tubular pole
(i) Pole as per IS code 410-SP-25 with 300 X 300 X
mm base plate with necessary G.I. J Bolts
(Approximate weight 78 Kg) For burial erection
(ii) Add Extra for M.S. Base plate 300 X 300 X 16 mm
for pole, mounting on surface of foundation on GI
foundation bolt. with required stiffeners.
(iii) Add Extra for PU base primer and PU Paint on
Providing and erecting street light pole bracket
comprising main B Class MS pipe of 4.2 cm/require
outside dia. complete with suitable B Class M.S.
sleeve tubing of approx. 45cms.length and suitable for
76.5 mm / 80mm. / require size pole top having
sufficient fasteners for fixing the brackets and having
spread of 1 mtr. length with suitable rise as per site
condition & suitable welded stiffener reducer and
nipple with check nut complete painted with one coat
of Red oxide / PU base primer and two coats of
Aluminium / PU paint. paint with following nos of
[C] Three Arm Bracket 1 Mtr
Supplying & erecting Galvanized M.S pipe post “B”
class 88.9 mm O.D 4 mtr. Long duly painted with two
coats of aluminium paint complete with metallic base
plate of 300 mm x 300 mm x 4mm thick for using as a
compound light pole with approx. weight 32 Kg.
Supplying & erecting approved make SMC press
moulded composite FRP. loop-in, loop-out approx.
2mm thick box complete with Bakelite connector strip
5way(3P+N+E),DIN rail for mounting mob & hinged
doors as per requirement having locking
arrangements with mounting clamp with nuts, bolts &
washers suitable for erection on pole with cable
clamps& earth bolt of following size of box.
(E) 200mm x 140mm x 125mm [deep]
Providing and erecting Pipe type earthing having
cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth
pit complete with necessary 8 SWG earth wire.
"Providing 1:2:4 cement concrete foundation & 70 %
PCC from bottom including excavation for the pole of
size 60 x 60 x 150 cm. Deep in below ground level
187 with plinth of 45 cm x 45 cm(or 45 cm dia x 45 cm) 50.00 Ea. 1949.30
high upper ground level with necessary curing and
finishing in approved manner.
( for 9 & 10 mtr pole)"
For using salt and charcoal / coke as required for pipe
Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free High pressure
die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95,
THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required LM-79 &
LM-80 certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity
between the ranges shown.)
(C) Post Top Lantern LED fitting comprises of finish
cast aluminum spigot and spun aluminum canopy
fixed with opal polycarbonate, pipe arrangement for
vertical mounting driver and accessories wired upto
terminal block.IP
Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free High pressure
die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95,
THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required LM-79 &
LM-80 certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity
between the ranges shown.)
(B) Flood Light (IP-65), Surge protection -4KV
integral and ,Light must have 440VAC line supply with
over-voltage protection.
(v) above 120 to 160 watts
Supply, Installation, testing and commissioning
including vaccumiazation and Nitrogen testing of
following nominal sizes of soft/hard drawn copper
refrigerant piping for VRV system, complete with
fittings, with suitable adjustable ring type hanger
supports, jointing/brazing including accessories,
insulated with XPLE Class-0 tubular insulation/with
191 Class-0 closed cell elastometric nitrile rubber tubular 120.00 Mtr. 515.10
sleeves sections of specified thickness as given
below for Suction and Liquid lines, all accessories as
per specifications etc with necessary refrigerant joint
(C.) 12.7 mm dia (OD) (Soft drawn) with tube
thickness 1.2 mm with 19 mm thick insulation
Supplying and erecting approved make water filter
having outer body of tough polycarbonate with fitter
cartridge having filter to trap micro elements with
coupling suitable for erection on pipe line.
Providing & laying approved make ISI marked Rigid
PVC pipe having 6Kg / cm2 (Class-3) to be erected at
road crossing on or floor as directed for laying of
193 cable. The pipes as following size of dia & weight per 50.00 Mtr. 146.45
(D) 75 mm inner Dia. (5.5 Kg/6RMT)
Supplying & erecting approved make LAN cable of
following size in existing pipe as per direction
Providing and erecting ISI mark Medium class RIGID
PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in approved
manner as directed
196 provideing & fixing 16 CH N.V.R 1.00 Ea. 16160.00
197 provideing & fixing 2 Mp camera 12.00 Ea. 3232.00
198 provideing & fixing Pob switch 2.00 Ea. 4545.00
PGVCL lisening work for getting 3 phase power
199 connection including payment of fq and all other 1.00 Ea. 40400.00
charges on behalf of commissioner BMC.
Total Amount Without GST
Total Amount Without GST
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. NIT.pdf
2.SBD.pdf
04_SPECIFICATION_INDEX.pdf
05_DETAIL_SPECIFICATION.pdf
06_CEMENT_CONSUMPTION.pdf
07_STEEL_CONSUMPTION.pdf
08_Building_Work_Specification_Booklet.pdf
09_Road_Work_Specification_Booklet.pdf
10_Electric_Work_Specification_Booklet.pdf
11.vendor list merged.pdf
11_Fire_Work_Specification_Booklet.pdf
13_Make_List.pdf
14.CONTR AGENCY 10 percentage DEPO.pdf
15.CHECK LIST.pdf
Special notes for this Tender.pdf
16.Ruva_Party_Plot_Extention schedule b (1).pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .