Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | L1 | Accepted-AOC Awarded to lowest | |
| 2 | L2₹11.1 L+₹45,920 (4.32%)Rejected-Finance | L2 | Rejected-Finance Bidder is L2 | |
| 3 | L3₹11.3 L+₹65,650 (6.17%)Rejected-Finance | L3 | Rejected-Finance Bidder is L3 |
| Sl No | Description | Qty | Unit | Sourab Kuthiala L2 | upvinder kumar L3 | M/s Jamwal nxt gen energy solutions L1 |
|---|---|---|---|---|---|---|
| 1.00Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. (Make:-Finolex,KEI,Anchor,L&T for wire) [Legrand (Myrius),L&T(Oris),Anchor(Roma plus) for accessories] | ||||||
| 1.01 | Group C. | 200 | P/Point | 1,800 ₹3,60,000 | 1,700 ₹3,40,000 | 1,650 ₹3,30,000 Lowest |
| 2.00Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. (Make:-Finolex,KEI,Anchor,L&T for wire) [Legrand (Myrius),L&T(Oris), Anchor (Roma plus) for accessories] | ||||||
| 2.01 | Group C. | 3 | P/Point | 1,850 ₹5,550 | 1,750 ₹5,250 | 1,700 ₹5,100 Lowest |
| 3.00 | Wiring for light plug with 2x2.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.2.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T ) | 250 | P/metre | 260 ₹65,000 | 260 ₹65,000 | 250 ₹62,500 Lowest |
| 4.00 | Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T ) | 230 | P/metre | 300 ₹69,000 Lowest | 320 ₹73,600 | 300 ₹69,000 Lowest |
| 5.00 | Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T ) | 120 | P/metre | 400 ₹48,000 Lowest | 420 ₹50,400 | 400 ₹48,000 Lowest |
| 6.00Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(Make:-Finolex,KEI,Anchor,L&T ) | ||||||
| 6.01 | 2x2.5 Sq. mm. | 312 | P/mtr | 260 ₹81,120 | 260 ₹81,120 | 250 ₹78,000 Lowest |
| 6.02 | 2x6.0 Sq. mm. | 12 | P/mtr | 380 ₹4,560 | 370 ₹4,440 Lowest | 380 ₹4,560 |
Tender Value
₹7.6 L
EMD Value
₹15,200
Closing Date
29 Jul 2021, 5:00 pmClosed
Executive Engineer
Elect. Division HPPWD Palampur
Construction of PWD Division office building at Nagrota Bagwan in Distt. Kangra, HP (SH- Providing E.I. therein)
2021_PWD_50225_2
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
365 days
Nagrota Bagwan in Distt. Kangra
Please refer Tender documents.
10 documents required · 10 mandatory
₹350
₹15,200
23 Feb 2026
22 Jul 2021
30 Jul 2021
22 Jul 2021
29 Jul 2021
22 Jul 2021
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. (Make:-Finolex,KEI,Anchor,L&T for wire) [Legrand (Myrius),L&T(Oris),Anchor(Roma plus) for accessories]
Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. (Make:-Finolex,KEI,Anchor,L&T for wire) [Legrand (Myrius),L&T(Oris), Anchor (Roma plus) for accessories]
Group C.
Wiring for light plug with 2x2.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.2.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T )
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T )
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T )
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(Make:-Finolex,KEI,Anchor,L&T )
2x2.5 Sq. mm.
2x6.0 Sq. mm.
2x10 Sq. mm.
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T )
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T )
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.(Make:-Finolex,KEI,Anchor,L&T )
3x2.5 Sq. mm.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required(Make:-BEC, AKG, Kalinga / Diplast )
25 mm dia
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:-
2 modules (78mmx78mmx50mm)(Make:-Legrand,L&T,Schneider )
6 modules(205mmx78mmx50mm)(Make:-Legrand,L&T,Schneider )
Supplying and fixing Electric Switch board having 3 No. of 5 amp switches and socket on suitable size of G.I Modular box of 205 mmx135 mm x60mm deep size with modular plate and cover in recess including providing and fixing 3 No 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.(Make:-Legrand,L&T,Schneider)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.Make:-Legrand (Myrius),L&T(Oris),Anchor(Roma plus)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as requiredMake:-Legrand (Myrius),L&T(Oris),Anchor(Roma plus).
Supplying and fixing following rating Moduler switch /socket on the existing switch box / cover including connections etc. ,as required.
S.P. 25 Amps one way Modular switch.
25 Amps Socket Modular .
Make:-Legrand (Myrius),L&T(Oris),Anchor(Roma plus)
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(Make:-Hagger,Legrand,L&T )
6 amp Single pole. Cat-A.
16 amp Single pole. Cat-A.
25 amp Single pole. Cat-A.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make:-Hagger,Legrand,L&T )
40 Amps. Cat-A.
63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make:-Hagger,Legrand,L&T )
40 Amps. Cat-A.
63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-(Make:-Hagger,Legrand,L&T )
Double door-6 way
Double door-12 way
Double door-16 way
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 50 sq. mm (3.5 core)
Sourab Kuthiala
upvinder kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .