Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.4 L+₹63,282 (4.59%)Rejected-Finance NORTH BEYPORE CALICUT 15 KERALA | KOZHIKODE | KERALA | 612906 | L2 | Rejected-Finance L2 |
Tender Value
₹12.5 L
EMD Value
₹31,350
Closing Date
7 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assisstant Executive Engineer
Office of the Assisstant Executive Engineer PWD Electrical Subdivision Thalassery
GENERAL-Budget 2024-25- Beautification of Small Towns at Dharmadam LAC-Chambad - Town beautification at Chambad - Providing Decorative Lights-General Electrical Work
2024_PWD_701197_1
PWD/BLDG/TR/15138/2024_6_2_1/2
Open Tender
Electrical Works
Item Rate
180 days
KANNUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹31,350
31 Mar 2025
1 Nov 2024
11 Nov 2024
1 Nov 2024
7 Nov 2024
1 Nov 2024
Amount
Footpath Lighting
OD134168/2024-2025:SITC of Decorative Pole 3 metre height above the ground level made out of GI, tubular pole ‘T’ washed and primered (ASTM A123) with dia of 76mm. The pole shall be with inbuilt junction looping box at bottom section with 32 A heavy duty 4 way connector for loop in & loop out and with MS base plate.The pole shall be suitable for wind loadings as per IS 875 part 3 1987. Design comply EN40 standard and basic wind speed 169kmph. Pole should be hot dip galvanized to 65 microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with two coats of epoxy primer and above that it should be given with polyurethane UV resistant coating (painted with avg. DFT of 70μm). The complete system should be hot dipped Galvanised. (3M pole Kesclec make ECO POLE/rila pole/ equivalent)
OD134169/2024-2025:SITC of Decorative classic Post top LED street lantern of system wattage of 45W, BIS certified with a Graphite grey powder coated die- cast aluminum alloy spigot, Diffuser- Optical grade opal/ frosted PMMA with high bright discrete LED, with an optical block (IP65) with heat sink and an anti UV PC protector (IK06). Constant current electronic driver provided with high voltage and open circuit protection suitable for 60mm dia pole. Overall system efficiency of 70 lm/W at correlated colour temperature (CCT) of 3045K, colour rendering index (CRI)more than 70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor more than0.95, with BIS certified potted driver having internal surge protection of 4 kV (BAJAJ BCF ANT 45W WW OP PT 70lm/W./ Equivalent)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD134170/2024-2025:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more.
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.16.2.4:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD134171/2024-2025:Supply and fixing 25A AC3, MNX 25, 3 Pole power contactor (L&T) conforming to IS/IEC 60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required-
OD134172/2024-2025:Supply and fixing Time switch 240V AC DIN/BASE mounting in the existing enclosure and giving connection as required- (L&T J648B1-Analog version/Hager EH111 Quartz Analog Daily Timer Switch)
OD134173/2024-2025:Supply and fixing 32A HRC fuse base with HRC fuse link-
OD134174/2024-2025:Supply and fixing of Neutral link 32 A, 2 Way neutral links mounted on DMC/SMC base-
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD134175/2024-2025:Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25 mm X 5 mm G.I. strip
OD134176/2024-2025:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 5 mm GI strip
OD134177/2024-2025:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 25x6 mm brass nut and bolt
OD134178/2024-2025:Supply and fixing 32 mm dia G.I. Pipe (light class) pipe including fixing the pipe with clamp/clips etc as required (For Service Pipe)
OD134179/2024-2025:Supply, installation testing and commissioning of bollard light of 650 mm height, 9w WW Led IP65 rated, with powder coated G. I. pedestal on existing concrete foundation with foundation bolts etc. as required.(Bajaj - BOLLARD LIGHT Tulip BGBOM 650 9W LED/equivalent)
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
OD134180/2024-2025:Supply Conveyance, installation, testing and commissioning of 12W, round surface mounting down light fittings of all types directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.
OD134181/2024-2025:Supply Conveyance, installation, testing and commissioning of 20W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD134182/2024-2025:Supply, conveyance & installation of Hensel make IP 66 / IP 67 weather proof 180x 130 x 77 mm cable junction Box ( KF 1006 B) with Terminal Set 2.5-6 sq.mm Copper
OD134183/2024-2025:Hire and Labour charges for Conreate core cutting
gopakumar.kv (BID ID -1968608)
Bidder Name
gopakumar.kv
PRADEEP KUMAR.V.K
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1095749.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .