Electrical General work in Connection with "ABSS: At Aluabari Road Jn. - Provision of Approach Road and Improvement of Circulating Area at 2nd Entry".
29_2026
29_2026
Open
6 Months
Unknown (Unspecified Location)
₹0
₹1.5 L
13 Jun 2026
13 Jun 2026
23 Jun 2026
Approach Road and Improvement of Circulating Area at 2nd Entry".
Item- 1 Please see item breakup for details.
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply & testing of GI octagonal pole 6 mt long Numbers 60.00 14193.00 851580.00
with foundation bolt, loop box of bakelite sheet
with one 6A SP MCB and 16 sq mm stud type
connector etc. The octagonal pole shall be hot dip
galvanized in single dip. Technical specification
of pole as following:- Height - 6 mt Top dia (A/F) -
70 mm Bottom dia (A/F) - 130 mm Sheet
thickness - 3 mm Base plate (L x B x T) - (200 x
200 x 12) mm Foundation Bolt size (no.x dia) - 4
x 20 dia mm Pitch Circle Dia (PCD) - 200 mm Bolt
length - 600 mm Projected Bolt Length - 100 mm
2 2 Supply & fixing of 1 mtr GI Single arm bracket Numbers 60.00 1615.00 96900.00
(header) and holder with Nut & bolt as per
instruction of Engineer incharge at site.
KATIHAR DIVISION-ELECTRICAL/N F RLY
3 3 Erection of Rail/Tubular/Octagonal pole to 1/5 th Numbers 60.00 1712.00 102720.00
of its height with CC foundation from base block
(30 cm x 30 cm x 15 cm) including digging &
refilling of earth to a height of 30 cm above
ground level as per drawing
no.CEE/OH@47'40@FGA) in ratio 1:3:6 by cement
sand & Chips 19 mm & down including
excavation of earth.
4 4 Supply, installation, testing & commissioning of Numbers 60.00 14159.00 849540.00
150 Watt LED Street Light made up of pressure
die cast aluminium housing with high efficiency
LEDs as lighting source and lens embedded PC
cover having TOP Opening seperate driver
compartment with IP66 protection and impact
resistance of IK08. as per instruction of Engineer
incharge at site.
5 5 Supply, testing & fixing of LED Rope Light 50 Numbers 18.00 7237.00 130266.00
Meters (Red, Yellow, Blue, Green, White as
required) Waterproof, IP 65 or above as per
instruction of Engineer Incharge at Site.
6 6 Supply, erection, testing & commissioning of 16 Set 1.00 740228.00 740228.00
mt long High Mast Tower with 8 nos. x 250 watt
LED luminaries in symmetrical arrangement
complete with all accessories (Double drum
winch, SS wire rope, integral power tool motor,
head frame, junction box, foundation bolt, LED
aviation light, Fedder pillar with single dial timer
& raising lowering mechanism etc.) including
shallow foundation with M20 grade concrete etc.
as per instruction of Engineer Incharge at Site.
7 7 Supply, installation, testing & commissioning of Numbers 20.00 16193.00 323860.00
250 watt LED flood light luminaires complete with
pressure die cast aluminium housing, IP 66,
Luminous efficacy 120 lm/watt with heat sink
feature, surge protection etc including wire
connection as per instruction of Engineer
incharge at site.
8 8 Supply, wiring, testing & commissioning of FL Numbers 150.00 184.00 27600.00
point/ Lamp point/Fan point (loop wiring) with
angular/ batten holder by FR PVC insulated and
unsheathed single core, 1.5 sq mm multistranded
copper cable to be drawn through rigid PVC
conduit pipe not less than 20 mm dia medium
gauge including bends, joints etc. from main line
under PP shed and 1 sq mm single core FR PVC
insulated and unsheathed copper wire for earth
continuity without controlling switch under PP
shed/FOB as per instruction of Engineer incharge
9 9 Supply, fixing, connection, testing & Numbers 225.00 4503.00 1013175.00
commissioning of Surface/Suspended mounted
LED Trunking Batten 40 watt, extruded aluminum
housing provided for efficient heat dissipation
with polycarbonate diffuser & Built-In electronic
driver. IP 54, CRI 80, THD(%) 10, CCT. 6500 K
Power Factor 0.95, Operating temperature: -10 C
to +50 C, Operating voltage range: 165 V - 270 V,
Average life 50000 hours, LED lumen efficacy 145
lm/W with a viewing angle of 120, Powered by
built-in electronic driver (SMPS based constant
current supply) with Output Open/Short-circuit,
Thermal fold back, 440V 8 Hrs protection, Surge
protection 4 KV & others safety test as per
IS:15885 Part 2/Sec 13. Havells Model No.
ACETRUNKINGADVS40WLED865PSYMBOPCWHT.
KATIHAR DIVISION-ELECTRICAL/N F RLY
10 10 Supply, wiring, testing & commissioning of Numbers 136.00 797.00 108392.00
concealed point wiring by FR PVC insulated and
unsheathed 1.5 sq mm, single core multi strand
copper wire with earth continuity wire by PVC
insulated and unsheathed 1 sq mm , single core
multi strand copper wire concealed on wall
through PVC rigid conduit pipe of dia not less
than 20 mm dia heavy duty including all types of
joints and bends as required, complete with 6
amps flush type controlling modular switch to be
mounted on modular GI inner plate and modular
mounting frame of suitable module as per
requirement complete to be concealed in wall as
per instruction of Engineer Incharge at site.
Existing wall should be cut and re-mended to
original finish by contractor's own material. (a) FL
Point/LED Tube Point/LED Recess Light Point/Wall
Bracket Fan Point/LED Mirror Light Point with
12 12 (c) Fan point with c/rose and 5 step fan regulator Numbers 20.00 1450.00 29000.00
14 14 Supply, wiring, testing & commissioning of Numbers 20.00 737.00 14740.00
concealed plug point on separate board complete
with 2 x 6 Amp modular socket and 6/10 amps
modular switch to be mounted on modular GI
inner plate 6M and 6M modular mounting frame
with GI box to be concealed in wall as per
instruction of Engineer Incharge at site. Existing
wall should be cut and re-mended to original
finish by contractor's own material.
15 15 Supply, wiring, testing & commissioning of Numbers 30.00 855.00 25650.00
concealed 6/16 amps power plug point on
separate board complete with modular 16 amps
switch (with indicator) and 6/16 amps 3 pin
combined shuttered socket to be mounted on
modular GI inner plate 4M or suitable size with
modular mounting frame to be concealed in wall
as per instruction of Engineer Incharge at Site.
16 16 Supply, wiring, testing & commissioning of mobile Numbers 20.00 231.00 4620.00
charging point complete with 3 nos 6 A flush type
controlling switch and 3 nos 6 amps, 5-pin socket
and 1 no MCB DP 10 amps fitted on separate half
flush MS board with hylem sheet top including
provision of painted MS tray of size (8 x 6) inch
for mobile holding as per instruction of Engineer
incharge at site.
17 17 Supply, fixing, connection & testing of 40 Watt Numbers 100.00 1890.00 189000.00
LED Tubelight, Surface/ Pendent mounting LED
Battens in Extruded aluminium housing as per
instruction of Engineer Incharge at Site.
18 18 Supply, installation, testing & commissioning of Numbers 20.00 2303.00 46060.00
Surface/Recessed LED luminaire with slim line
CRCA sheet metal body, square type, (System
wattage-18 Watt, Nominal system efficacy 120
lm/watt) suitable for 600 x 600 mm modular
ceiling as per instruction of Engineer incharge at
19 19 Supply and testing of wall mounted bracket fan Numbers 10.00 1998.00 19980.00
400 mm sweep complete with all accessories to
be fixed on wall by suitable fixing arrangement
including connection by 2 core, 1.5 sqmm PVC
insulated and FR PVC Round Sheathed, Copper
Conductor (flexible) industrial cable as per
instruction of Engineer Incharge at Site.
KATIHAR DIVISION-ELECTRICAL/N F RLY
20 20 Supply, fixing, connection, testing & Numbers 6.00 1336.00 8016.00
commissioning of surface mounting sleek LED
mirror light 5 W or 7 W, IP 20, 1 ft version powder
coated CRCA housing, high output diffuser
including suitable fixing arrangement on surface
as per instruction of Engineer incharge at site.
21 21 Supply, fixing & testing and commissioning of Numbers 20.00 670.00 13400.00
LED 12 W B22 CDL INVERTER BULB V2 as per
instruction of Engineer Incharge at Site.
22 22 Fixing, testing & commissioning of ceiling fan Numbers 20.00 46.00 920.00
with supply & fixing of MS clamp with hook, nut,
bolt, washer etc. as per instruction of Engineer
incharge at site. (Fan will be supplied by Railway)
23 23 Supply, installation, testing & commissioning of Numbers 12.00 2824.00 33888.00
300 mm sweep (metallic) heavy duty exhaust
fan, 1400 RPM complete with fixing on wall by
suitable size bolts & nuts grouted on wall as per
instruction of Engineer incharge at site.
24 24 Supply, wiring & testing of main wire by 2.5 sq Metre 800.00 75.00 60000.00
mm, Single Core FR-LSH PVC Insulated Industrial
Grade Copper Conductor (Unsheathed) Flexible
Cables, 1100 Volts and earth continuity wire by
1.0 sq mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694
concealed in wall through PVC rigid conduit pipe
not less than 20 mm dia as per instruction of
Engineer incharge at site.
25 25 Supply, wiring & testing of main wire by 4 sq mm, Metre 800.00 87.00 69600.00
Single Core FR-LSH PVC Insulated Industrial
Grade Copper Conductor (Unsheathed) Flexible
Cables, 1100 Volts and earth continuity wire by
1.0 sq mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694
concealed in wall through PVC rigid conduit pipe
not less than 20 mm dia as per instruction of
Engineer incharge at site.
26 26 Supply, wiring & testing of main wire by 6 sq mm, Metre 500.00 100.00 50000.00
Single Core FR-LSH PVC Insulated Industrial
Grade Copper Conductor (Unsheathed) Flexible
Cables, 1100 Volts and earth continuity wire by
1.0 sq mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694 through
PVC rigid conduit pipe/polythene pipe not less
than 20 mm dia as per instruction of Engineer
incharge at site.
27 27 Supply, wiring & testing of main wire by 10 sq Metre 500.00 110.00 55000.00
mm, Single Core FR-LSH PVC Insulated Industrial
Grade Copper Conductor (Unsheathed) Flexible
Cables, 1100 Volts and earth continuity wire by
1.0 sq mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694 through
PVC rigid conduit pipe/polythene pipe not less
than 25 mm dia as per instruction of Engineer
incharge at site.
28 28 Supply, installation, testing & commissioning of Numbers 8.00 1193.00 9544.00
modular power unit complete with 32 Amp mini
MCB DP "C" series 3kA , 25 amps starter, 25 Amp
Socket and 25 Amp plug to be mounted on 6
module GI box, 6 module combined plate
concealed on wall and wiring by 6 sq mm, Single
Core FR-LSH PVC Insulated Industrial Grade
Copper Conductor (Unsheathed) Flexible Cables,
1100 Volts with earth coninuity wire by 1 sq mm
copper cable Conforming to IS: 694 to be drawn
through Rigid PVC conduit pipe not less than 20
mm dia as per instruction of Engineer incharge at
site. (For AC & Geyser)
KATIHAR DIVISION-ELECTRICAL/N F RLY
29 29 Supply, installation, testing & commissioning of Numbers 6.00 54091.00 324546.00
Inverter Split Air Conditioners 1.5 Ton, (BEE star
rating-5 star, Coil material-Copper, Echo-friendly
refrigerant, Nominal cooling capacity in Ton /
(kcal/hr)-1.5 Ton / 4500 kcal/hr) with all
accessories as per OEM suitable for operation on
230V AC ,single phase, 50 Hz as per instruction of
Engineer incharge at site. Re-mending work
should be done after installation of RAC. (with 1
pair outdoor wall stand) (Industrial AC/Heavyduty
30 30 Supply, installation, testing & commissioning of Metre 200.00 1561.00 312200.00
Hot Dipped Galvanized Wire Mesh Cable Tray of
size (Depth- 54 x Width- 150) mm, made of
carbon steel (ASTM A510, Grade-1008 specified)
finished by electrozinc plating (ASTM B 633
specified) alongwith all accessories like suitable
type of splices, locking tab, divider coupler,
preclick, SWK, clamp, Tee, bend, bracket, nut,
bolts etc. Trays should comply standard EN ISO
1461: atleast 550 h of SST. Assemblies with
specific fire resistant properties must have an
E30-E90 certificate. Rod-dia must be from 3.9
mm to 5.9 mm or higher and as per site site
requirement and as per instruction of engineer
incharge at site.
31 31 Supply, installation, commissioning & testing of Square 72.00 1772.00 127584.00
LED indication station name board (Length of Foot
board will be as per proportion of letter so that all
the 4 side of the board will have extra space)
with channel letters with 3.75 ft. in lenght with
suitable widen and 4 mm projection size which
inside ACP board (Brand- ALUDECOR, category-
AL 33 series exterior & thikness-3 mm) with
acrylic face on front and having Sumsung 5630
LED's (Shape- Lens type, operating voltage- 12 V
DC, carring current-80 mA, power Dissipation-
0.96 watt, working hours-50000, case material-
ABS ,protection-IP68) inside for illumination
letters in English, Hindi, Bengali or regional
language complete with all materials including
provision of erection structure made of MS
angle/channel/flat duly painted with aluminium
paint over a coat of red oxide primer with CC
foundation (1:3:6) of cement, sand and stone
chips as required at site and as per instruction of
Egnineer incharge at site.
32 32 Design, manufacture, display of wall /hanging / Square 40.00 2868.00 114720.00
floor mounting type LED illuminated sign / Foot
direction boards in half elliptical shape. The
display sheet shall be of unbreakable 040
translucent polycarbonate sheet of 2 mm
thickness. The text / graphics matter visibility
shall not be less than 160 deg. The approved
colour text and graphics shall be printed / router
cut on monomeric calendered vinyl of 70 mm
thickness and shall be firmly pasted on display
sheets. The mounting arrangement shall be
hanging, wall mounting, ceiling mounting, pole
mounting or floor mounting and as per site
requirement. The signage shall have the integral
mounting arrangements with sturdy structural
frame and ACP cladding on the back side of the
signage to avoid rusting and entry of dust. The
LED board shall have uniform illumination with 4-
8 W / sq. ft and with brightness more than
ambient light. Suitable size end cap of 1.5 mm
thick SS 304 should be provided. (Signage Board
should as per Railway Board Letter No. 2023/SD-
KATIHAR DIVISION-ELECTRICAL/N F RLY
33 33 Erection and installation of wall / hanging / floor Square 40.00 287.00 11480.00
mounting type LED illuminated sign / direction Foot
boards in half elliptical shape. The display sheet
shall be of unbreakable 040 translucent
polycarbonate sheet of 2 mm thickness. The
text/graphics matter visibility shall not be less
than 160 deg. The approved colour text and
graphics shall be printed / router cut on
monomeric calendered vinyl of 70 mm thickness
and shall be firmly pasted on display sheets. The
mounting arrangement shall be hanging, wall
mounting, ceiling mounting, pole mounting or
floor mounting and as per site requirement. The
signage shall have the integral mounting
arrangements with sturdy structural frame and
ACP cladding on the back side of the signage to
avoid rusting and entry of dust. The LED board
shall have uniform illumination with 4-8 W / sq. ft
and with brightness more than ambient light.
Suitable size end cap of 1.5 mm thick SS 304
should be provided. (Signage Board should as per
Railway Board Letter No. 2023/SD-II/22/07/02
34 34 Supply, installing, testing & commissioning of Numbers 1.00 404250.00 404250.00
High Volume Low Speed (HVLS) FAN, 3 Phase, 1.2
KW, 20 ft. Diameter, 6 (Six) Blade with Control
Panel and all acessories as per Instruction of
Engineer Incharge at Site.
35 35 Horizontal machine boring of 300 mm dia hole Metre 100.00 2538.00 253800.00
across track/Road/High drain etc. at a depth of
1.0 mtr below of ground level with suitable boring
instruments & neessary arrangement and as per
technical procedure.
36 36 Supply, laying, commissioning & testing of CI Pipe Metre 150.00 877.00 131550.00
100 mm dia Class LA type (IS 1536-2001) to be
laid partly along the pole and partly through
ground under railway track/road in cable trench
for protection of cable with suitable fixing
arrangement by MS clamp, nut,bolt,washer
etc.as per instruction of Engineer incharge at
37 37 Supply, laying, commissioning & testing of HDPE Metre 300.00 383.00 114900.00
pipe 110 mm dia PN-6 grade conforming IS
4984/1995 or latest to to be laid partly along the
p o l e with suitable fixing arrangement by MS
clamp m ade of MS flat of size 50x6 mm and
suitable size nut, bolt, washer as per instruction
of Engineer incharge at site.
38 38 Supply, laying, commissioning & testing of HDPE Metre 1000.00 70.00 70000.00
pipe 50 mm dia, PN-6 grade to be laid partly
along the p o l e / w a l l with suitable fixing
arrangement by MS clamp made of MS flat of size
50x6 mm and suitable size nut, bolt, washer etc
as per instruction of Engineer Incharge at site.
39 39 Supply, fixing, testing & commissioning of IP Numbers 10.00 10035.00 100350.00
66/67 thermoplastic cable junction box / loop box
of size (300 x 450 x 170) mm with knockouts &
04 nos terminals as per instruction of Engineer
Incharge at Site.
40 40 Supply, fixing, testing & commissioning of IP Numbers 15.00 5291.00 79365.00
66/67 thermoplastic cable junction box / loop box
of size (210 x 310 x 116) mm with knockouts &
04 nos terminals as per instruction of Engineer
incharge at site.
KATIHAR DIVISION-ELECTRICAL/N F RLY
41 41 Supply & Erection of earth by 50 mm dia 3 Mtrs. Numbers 30.00 4349.00 130470.00
long (3.6 mm thickness) GI pipe, 32x6 mm GI
strip- 5 Mtrs, GI nuts, bolts including masonry
materials for earthing pit, salt, charcoal, soldered
end terminal etc. and construction of earth pit
covered with RCC cover slab12.7 mm thickness
and watering pipe as per Drg. No.-
PCEE/ELG/DRG/2024/1 Date:- 30.09.2024 and as
per instruction of Engineer Incharge at site.
42 42 (a) Supply, installation, testing & commissioning Set 2.00 12330.00 24660.00
of 4 way VTPN MCCB DB (MCCB+12 modules)
with IP 43 grade protection, metal door with wire
sets, busbar, earth bar, blanking plates, cable
ties etc with supply and fixing of following
MCCB/MCB as per instruction of Engineer
incharge at site.
Conforms to IS/IEC 60898 - 1:2002
45 45 (a) Supply, installation, testing & commissioning Set 6.00 2005.00 12030.00
of 12 way SPN Distribution Board, Flush/Surface
mounting, IP 43 grade protection with copper bus
bar, fully shrouded neutral bar, earth bar, cable
ties, metal double door as per IS 8623 - III with
supply and fixing of following RCBO/MCB's as per
instruction of Engineer Incharge at Site.
Conforms to IS/IEC 60898 - 1:2002
Conforms to IS/IEC 60898 - 1:2002
48 48 (a) Supply, fabrication, erection, testing, Set 1.00 32916.00 32916.00
commissioning & painting of floor mounted
powder coated cubicle panel board (Modular look)
of suitable size (neither big nor small) ), outdoor
type with double door made of suitable size
MS/GI angle 50 x 50 x 6 mm, MS/GI flat 50 x 6
mm, 14 SWG MS sheet/Powder coated CRCA
sheet with provision of weather proof,rust
proof,dust proof,water proof having internal
rubber gasket with supply and fixing of following
ACB/MCCB/Bus bar/Meter etc. (Connections to be
made by copper strips, glands should be
provided at cable entry and exit, components
should be compartmentalized, Each compartment
will be provided with the door and pad locking
arrangement. The compartment illumination
lamp with door operated switch shall be provided
for each compartment. Panel board drawing
approval must be obtained with clear indication
of make of items of components):-
52 52 (e) Copper bus bar 200 amps made of electrolytic Set 1.00 1222.00 1222.00
grade copper consisting of 4 bars ( 3 Ph and
Neutral ) ( Bus bar should have insulation cover)
53 53 (f) Digital voltmeter (0-500) amps and Digital Set 1.00 5581.00 5581.00
ammeter (0-500) amps with s/switch and CTs
55 55 (h) Supply, installation and testing of Astro Set 1.00 9777.00 9777.00
(Analog) time switch with 3 pole 63 amp
contractor and suitable thermoplastic box and
fitted on mounting plate/DIN rail.
KATIHAR DIVISION-ELECTRICAL/N F RLY
56 56 Supply, laying & testing of 3 core, 2.5 sq mm PVC Metre 745.00 147.00 109515.00
insulated and FR PVC Round Sheathed, Copper
Conductor (flexible) industrial cable, 1100 Volt,
conforming to IS 694 as per instruction of
Engineer Incharge at Site.
57 57 Laying, commissioning & testing of HT/LT Metre 2000.00 55.00 110000.00
XLPE/PVC cable of different sizes partly along the
pole and partly through ground in cable trench by
excavation of ground below 1.5 mt from ground
level with suitable fixing arrangement by MS
clamp of size 50x6 mm and suitable size nut,
bolt. Loading, Unloading & Carrying of cable to
actual work site by contractor's own
arrangement. (Aluminium Crimping Socket
should be provided for each Cable Termination).
(Cable will be supplied by Railway)
58 58 Excavation of cable trench (0.3 x 1.5) mtr below Metre 1010.00 148.00 149480.00
ground level for laying of cable & refilling the soil
after digging the earth as per instruction of
Engineer incharge at site. Cable should be laid on
bedding of height 75 mm sand at the bottom of
trench, and covering it with additional sand of
height 75 mm and thereafter protecing it by
mean of bricks before refilling the soil as per IS
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril-2022PDFwithallACS_compressed.pdf
ATTACHMENT
NITABSSAUBApproachRoadcirculatingArea2ndEntry.pdf Tender Paper
ATTACHMENT
NITABSSAUBApproachRoadcirculatingArea2ndEntry.pdf
ATTACHMENT
Download all tender documents and submit your bid