| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | ₹2.3 Cr Quoted ₹2.4 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹2.8 Cr+₹47.9 L (20.2%)Rejected-Finance | ₹2.8 Cr+₹47.9 L (20.2%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹3.0 Cr+₹63.7 L (26.9%)Rejected-Finance C 301 SHREE BALAJI RESIDENCY BEHIND SANGATH SILVER APARTMENT SABARMATI GANDHINAGAR HIGHWAY MOTERA AHMEDABAD 380005 | AHMEDABAD | AHMEDABAD | GUJARAT | 380005 | ₹3.0 Cr+₹63.7 L (26.9%) | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹3.1 Cr+₹77.8 L (32.9%)Rejected-Finance | ₹3.1 Cr+₹77.8 L (32.9%) | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹3.4 Cr+₹1.0 Cr (43.0%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹3.4 Cr+₹1.0 Cr (43.0%) | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹3.5 Cr
EMD Value
₹4.3 L
Closing Date
28 Feb 2022, 6:00 pmClosed
CHIEF ENGINEER CG GOA
CHIEF ENGINEER CG GOA 403806
ADDN ALTN AND SPECIAL REPAIRS TO HANGAR DOOR WITH AUTOMATION AT ICGAE PORBANDAR
2021_MES_460002_4
81012E8
Open Tender
Civil Works
Item Rate
270 days
PORBANDAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE (I) (CG) PORBANDAR
₹4.3 L
Yes
19 Apr 2022
2 Feb 2022
2 Mar 2022
2 Feb 2022
28 Feb 2022
9 Feb 2022
Amount
NOTE: The rate quoted shall include for design of door as per parameters mentioned in the Schedule 'A' Note No 14. Also door designed shall be got vetted by an IIT/ Approved Govt. agency before commencement of work on ground. Taking down and refixing of hanger door of size 40M x 10M (each door consisting 08 leaf of weight 2.5 to 3 ton each ) ,dismantling of complete top tracks, dismantling of complete bottom guide rail,removal of all guide wheels top & bottom and Addn/Altr with following specifications :- (a) Supply & fixing of complete Top tracks(Apprx 310Rm), medium channel ISLC 150 of size, 150x75 mm shall be within the door pocket frame to be designed and installed independent of the hangar buildings. Top tracks will be suitably integrated with the main building structure. Suitable arrangements will be made by the manufacturer to attach the top tracks and sealings with the top girder in order to hold the door in place. (b) S&F of upper frame section of each leaf with a minimum of 2 horizontally arranged guide wheels. These wheels shall be fitted with low maintenance ball bearing made of steel which are mounted on a galvanized steel axis. This steel axis shall be fixed in the frame in a suitable manner that the door frame is held firmly and safely in event of thermal expansion and wind situations. (c) Supply & fixing vertical sealing between the two middle door leafs is affected via special two-piece EPDM profiles running along the entire length of the door panels. The vertical sealings between the adjacent door leaves as well as in between the building and the door leaves consist of a two piece EPDM rubber gasket with an efficient joint transmission coefficient value. (d) Replacement ,Supply & fixing of complete bottom rail (Approx 310 m), suitable size of weight 15 kg/mtr that shall prevent excessive deflection against the vertical loads of the door leaf panels and prevent the ingress of the adjoining concrete. The bottom tracks shall have inbuilt ingress for storm water collection in the tracks.
(e) Supply & fixing lower carrying rollers /wheels, 2 wheels per leaf , shall be made of casted MS . These running wheels shall be mounted in a MS casted housing. The wheel housing shall be bolted / welded in the corner area of the door leaf. (f) Water in the grooves to be drained through the galvanised drainage ducts mounted under th e bottom guide rails in regular intervals via collecting pipe. Each collecting pipe is equipped with one cleaning opening (g) Collision buffer to be mounted in the area of each top track. Each shock absorber unit to consist of a solid accommodation console of galvanized steel (h) Making good of disturbed surfaces is involved in the work, like demolition of RCC, steel reinforcement, epoxy flooring etc and to make good to the surfaces of RCC in beam with M-30 and PQC M-40, reinforcement shall be used TMT bars (CRS) of FE-500D, epoxy flooring with epoxy mortar to match with existing floor/construction. (j) Supply and fixing of PVC bird proofing zero size net with alluminium frame complete at top of track in horizontally portion.(Apprx 80Sqm) (k) Supply and fixing of galvalume plain sheet 0.5 mm thick on front face of top track to cover the channel. Misc ie.Supply and fixing of Vertical sealing between the two middle door,galvanised drain duct etc. It is the reponsibilty of the contractor to visit the site oprior to quoting the tender. (l) Safety edge control device: The squeezing and shearing joints are secured at the door leaf ends via appropriate electro mechanical safety edge control devices . The edge control device shall posses an overall height and switching effect upto 2.5m height and are mounted at the front of the vertical frame profiles. The safety edge control device shall consist of semi circular EPDM rubber profile and the ends of this profile are laterelly reinforced with special aluminium profiles. The door leaf shall stop in its moving direction and reverses its original position . (m) Audio visual alarm system: Each drive leaf is fitted on the inside face with an audible alarm and visual alarm. NOTE 1 Any other replacement required for efficient movement of doors is deemed to be included in quoted rates. NOTE 2 It shall be ensured that no derailing of wheels shall take place. Necessary provisions shall be made for efficient movement of doors. NOTE 3 Painting using epoxy paint shall be carried out on all steels surfaces. The rate quoted shall include for the same.
Dismantling plain or corrugated steel sheeting any gauge, thickness including naintal or similar pattern roof coverings/cladding/hangar door etc
Supply and fixing prepainted galvalume alumnium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in cladding, fixed with self tapping screws complete all as specified.
Supply and fixing prepainted galvalume alumnium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in cladding, fixed with self tapping screws complete all as specified.
Taking down old unserviceble cable from site of following size (a) 10 to 16 Sqmm
Taking down old unserviceble control cable of following size (a) 1.5 to 2.5 Sqmm multicore cable
Taking down old unservcable LT panel complete all as specified and as directed
Taking down old motor of any capacity and any make and deposited to MES store complete all as specified and as directed
Supply and fixing induction motor of1.5/ 2 HP 3 Phase 415 Volt 50 Hz 4 Pole coupled with suitable gear box complete all as specified and as directed Note :cost of control gears are included in the quoted rate Make Kirloskar /CG/ABB/Seimens
Supply installation and testing of 3 phase and neutral, 415 volts factory made, indoor type,IP 43 free standing, floor mounting, dust and vermin proof cubical type, LT panel fabricated from 1.6 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coated prewired with suitable size of copper strip comprising of the following (a) (incoming ) MCB 40 TPN 4 Pole 10KA -01 No (b) (Outgoing ) MCB 32 amp 4 Pole 10 KA -04 No (c) Contactor 10 Amps -08Nos (d) Digital Multifunctional Panel meter of size 96X96 mm and three current transformer of suitable ratio and capacity 01 SET. (e) Overload relay 2.5 to 4 Amp (f) SMPS 220/24 Volt DC capacity 5 Amp (g) Plug in Relay 14 Pin with base-02 No (h) LED Push button switch green and Red -02 Nos (j) Emergecny Off with lock & Key -01 No (k) Indicator Red & Green RYB-01 Set (l) Connector-12 nos (m) Adone Block (1No+1AC) -04 Nos (n) VFD Controls-4 No (o) Proximetry Senser -08 Nos
M & L for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, fabricated of, insulated, shock proof, dust proof, water proof, anticorrosive complete including copper bus bar 200 Amps 4 strip mounted on porcelain insulated & enclosed in chamber & connection from incoming and out going with openable shutter both sides comprising of following (a) Copper Bus bar RYB and N of 200 Amp capacity one set (b) Incoming : MCCB 4 Pole 63Amp,50Hz, 415 V with rupturing capacity 25 KA -01 No (c) (out going) MCB 40 Amp FP 415 Volt 10 KA -2 no (d) Digital Multifunctional Panel meter of size 96X96 mm and three current transformer of suitable ratio and capacity Each1
Supply , laying , jointing and testing XLPE armoured heavy duty electric able with aluminium conductor 1100 volts grade of size 16 Sq mm 4 Core complete all as directed.
Supply , laying , jointing and testing XLPE armoured heavy duty electric able with aluminium conductor 1100 volts grade of size 10 Sq mm 4 Core complete all as directed.
Supply, laying & testing PVC insulated, PVC sheathed cable electric control cables 1100 Volt grade with stranded copper conductor of size 4 Core 2.5 Sqmm .
Supply, laying & testing PVC insulated, PVC sheathed cable electric control cables 1100 Volt grade with stranded copper conductor of size 8 Core 1.5 Sqmm .
S & F Rigid steel ERW conduit of 25 mm dia ISI marked heavy duty with saddles complete all as specified and as directed
S & F Junction box with cover and oulet for rigid steel ERW of size 25 mm dia complete all as specified and as directed Note for item No 1.12 to 1.17 : Fixing accessories for cable and ERW conduit such as sadlles , screws & washers etc are deemed to be included in unit rate
M & L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised steel wire of diameter 4.0 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 15 mm diameter, connected to earthing test point, all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. as all specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised steel strip of size 32x6mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. as all specified and directed.
NEW GURBINDER INDUSTRIES
Hariom Projects Pvt Ltd
Hi Tech Transpower Pvt Ltd
VIJAY CONSTRUCTION CO
Gandhi Automations Pvt. Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .