Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.8 LAccepted-AOC | 1 | Accepted-AOC lowest bidder | |
| 2 | Rejected-Technical CA 325 SA767 PWD K EL 13 1 472 CASAMARINA COMPLEX TALAP KANNUR | KANNUR | KANNUR | KERALA | 670101 | - | Rejected-Technical second lowest bid |
Tender Value
Refer Docs
EMD Value
₹35,637
Closing Date
30 Jan 2025, 6:00 pmClosed
Executive Engineer PWD Electrical Division Kannur
PWD Electrical Division Kannur
LAC-ADS-2023-24 Taliparamba LAC - Sri M V Govindan Master MLA - Beautification of Malapattam - Munambukadavu bridge- Providing decorative Street Lights on Malapattam - Munambukadavu bridge-General Electrical Work
2025_PWD_729506_1
PWD/BLDG/TR/15655/2024_6_1_1/1
Open Tender
Electrical Works
Item Rate
150 days
Thaliparmba
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹35,637
22 Feb 2025
23 Jan 2025
31 Jan 2025
23 Jan 2025
30 Jan 2025
23 Jan 2025
Amount
Providing Decorative Poles
OD234100/2024-2025:Supply conveyance installation, testing and commissioning of Decorative Pole 6 metre height above the ground level made out of GI, pipe section with die cast aluminium embellishments including connector foundation bolt 4 nos fixed in existing RCC foundation. The poles should have diameter of 114mm to 140mm at the bottom minimun 2000 mm length 60mm to 90mm at the middlle minimum 3000 mm length and 40mm to 50mm at top minimum 1000mm length . The pole should should be pure polyester based powder coated with high corrosion resistance and chemical chromatised protection. The base should be made of die cast MS with holes suitable for 16/20/24 mm foundation bolts including supply and fixing Hot Dipped Galvanised single arm decorative bracket (Model No: Crompton HM DECO SA NS) tightened to the pole to mount the luminaries etc as required shall be incorporated. The pole shall be with inbuilt junction looping box at bottom section with 32 A heavy duty 4 way connector for loop in and loop out and 1 no 6 A SP MCB and with MS base plate. The pole shall be suitable for wind loading and as per IS 875 part 3 1987: ( Make Crompton Voila HM-DECO/ K lite Pelican Orion /Keslec technically equivalent)
OD181418/2024-2025:SITC of LED Decorative Classic luminaire of system wattage 60 W suspended type asymmetrical light distribution Clear acrelic/poly carbonate diffusser with minimum 425mm diameter , BIS certified with a body and frame of high pressure die cast aluminium, separate optical and control gear compartment accessed by opening four screws at the top of the luminaire, a vent pressure equalization unit and pre-cabled as required. The luminaire shall have ingress protection of IP65. Highly efficient temperature resistant lenses for light distribution with several optical options providing excellent photometry to optimally cater to different applications. Overall system efficiency of minimum 125lm/W at correlated colour temperature (CCT) 3000K (ww), rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240V AC , Power Factor >0.95, with BIS certified potted driver having internal surge protection of minimum 6 kV . ( K lite Pelican Fort Mini 4897 WW LED/ Kesslec Porto NU WW with opal shallow PMMA protector /Crompton Empire WW equivalent)
OD181422/2024-2025:Fabrication , supply , erection and assembling GI clamps made of 32x6mm G.I. strip with suitable nuts and bolts for fixing pole or pipe including painting whole portion as per standards
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD120629/2024-2025:Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
OD120630/2024-2025:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel as required.
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
OD181427/2024-2025:Supply and fixing Digital Time switch 240V AC DIN/BASE mounting in the existing enclosure and giving connection as required- (L&T110-240 V Digital Time Switch 67DDTO)
OD181428/2024-2025:Supply and fixing 25A AC3, MNX 25, 2 Pole power contactor (L&T) conforming to IS/IEC 60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required-
OD120634/2024-2025:Supply and fixing 32A HRC fuse base with HRC fuse link-
OD120635/2024-2025:Supply and fixing of Neutral link 32 A, 2 Way neutral links mounted on DMC/SMC base-
90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD120637/2024-2025:Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25 mm X 3 mm G.I. strip
OD120638/2024-2025:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm GI strip
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
OD120639/2024-2025:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 25x3 mm brass nut and bolt
OD120640/2024-2025:Supply, Installation, Testing, and Commissioning of 1 kWp on-grid Solar PV Modules of the crystalline silicon type- mono perc Half cut, Conforming to MNRE specification mounted on Aluminium frame (minimum thickness 35 mm) With minimum module efficiency of 20%, manufactured in India with On grid inverter . As per latest edition of IEC PV module qualification test or equivalent BIS standards Crystalline Silicon, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required :a) Solar Photovoltaic Module conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. ,Interconnecting between panels using solar dc cable of min 4 sqmm . PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) and 240 V AC, single phase, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency, The PCU/ inverters should be tested from the MNRE approved test centres / NABL /BIS /IEC accredited testing calibration laboratories ,Manufacturing warranty10years.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories, etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, a main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.g) Statutory fees such as KSEB Fees
OD120641/2024-2025:Providing Structure work required for installation of Solar plant with purlin/single section with G I round/ rectangular pipes including cutting, hoisting, fixing in position and two coat painting with suitable paint over a coat of approved steel primer, including welding and bolted with special shaped washers etc. complete as required.
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
OD120642/2024-2025:Fabrication, supply, conveyance and installation of Granite name board with table rubbed, edges rounded and polished, of size 75x50 cm or nearest size deep and 1.8 cm thick , with inscription there on indicating name of project the cost involved, the dates of commencement, completion, inauguration etc , fixing it on suitable place including fixing charge etc as required .
Sajju T (BID ID -2084015)
Bidder Name
Sajju T
Vinod Kumar M
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1162836.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .