Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.6 CrAdmitted-Finance | -14.99% | ₹2.6 Cr | L1 | Admitted-Finance |
| 2 | L1₹2.6 CrAdmitted-Finance AT PO PATASUNDARPUR KAKATPUR DIST PURI 752108 | KAKATPUR | PURI | ODISHA | 752108 | -14.99% | ₹2.6 Cr | L1 | Admitted-Finance |
| 3 | L1₹2.6 CrAdmitted-Finance | -14.99% | ₹2.6 Cr | L1 | Admitted-Finance |
| 4 | L2₹3.0 CrAdmitted-Finance | +0.00% | ₹3.0 Cr | L2 | Admitted-Finance |
| 5 | L2₹3.0 CrAdmitted-Finance | +0.00% | ₹3.0 Cr | L2 | Admitted-Finance |
Tender Value
₹3.0 Cr
EMD Value
₹3.0 L
Closing Date
16 Jan 2026, 5:00 pmClosed
CCE Khordha RandB Circle Khordha
O/o the Chief Construction Engineer Khordha R and B Circle Khordha
Construction of 6(Six) Numbers of D type flat quarters (G plus 2) in the Premises of commercial Tax Colony in Puri District .
2026_EICCL_124103_1
CCE KHORDHA R and B CIRCLE 09 2025-26
Open Tender
Civil Works - Buildings
270 days
Puri
3 documents required · 3 mandatory
₹10,000
₹3.0 L
Yes
23 Apr 2026
2 Jan 2026
17 Jan 2026
2 Jan 2026
16 Jan 2026
2 Jan 2026
2 Jan 2026 - 16 Jan 2026
Dismantling brick or stone masonry in lime or cement mortar under 3mtr height including stacking the useful materials for reuse and removing the debris within 50m lead Including all cost i.e cost of all materials, all labour, all T&P, royalty etc complete in all respect as per direction of Engineer in charge. Ground Floor
Dismantling and removing cement concrete including stacking the useful materials for reuse and removing the debris within 50m lead Including all cost i.e cost of all materials, all labour, all T&P, royalty etc complete in all respect as per direction of Engineer in charge. Ground Floor
Earth work in excavation in foundation in ordinary soils in trenches, column foundation, pit etc in hard soil including dressing of sides and levelling the bed upto the required depth and depositing the excavated materials away from the work site with initial lead of 50mt and all lifts including shoring, shuttering and dewatering (if required) with cost of labour , labour cess, hire and running charges of all materials complete Including all cost i.e cost of all materials, all labour, all T&P, royalty etc complete in all respect as per direction of Engineer in charge. Ground Floor
Supplying & Filling foundation trenches , plinth & ditches with clean coarse river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking, royalties and all cost & conveyance of water, cost of all Labour,labour ess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. Ground Floor
Supplying diluting and preparing chemical emulsion like CHLORPY RIPHOS or other chemicals approved by central insectiicides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as per constructional anti termite treatment and creating a chemical barrier under and column pits and trenches basement excavation top surface of plinth filling junction of walls and floors along with external perimeter of the building expansion joints surrounding the pipes and conduits etc complete at the rate of 7.5 litters or as directed by the Manufacturer per sqm on vertical and 5.0 litters per sqm on horizontal surfaces 50% of the emulsion to be filled in the holes made in trenches at 150mm centrer to center etc complete as per IS 6313/1981 (Part-II) and as per the direction of the Engineer-in-Charge including cost of all materials, labour,taxes etc complete.Ground Floor
Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size hard crusher broken granite stone aggregate and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including all cost, conveyance, royalties and cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge. Ground Floor
Fly Ash brick masonry in cement mortar (1:6) in Foundation and plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including all cost, conveyance, royalties with all labour,labour cess and T & P required for the work complete in all respect as per specification and direction of tne Engineer-in-Charge. Ground Floor
Fly Ash brick masonry in cement mortar (1:6) in Super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including all cost, conveyance, royalties with all labour,labour cess and T & P required for the work complete in all respect as per specification and direction of tne Engineer-in-Charge. Ground Floor
First Floor
Second Floor
Terrace Floor
Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 using 12 mm. to 20 mm. (½inch to ¾inch) size (20 mm. not to exceed 25%) hard crusher broken granite stone aggregate of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with all cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge. Ground Floor Foundation
b)Column upto plinth Ground Floor
c)Plinth Beam Ground Floor
d)Column upto roof Ground Floor
e)Lintel :Ground Floor
f)Chajja Ground Floor
g)Fin Ground Floor
h)Roof Beam : Ground Floor
i)Roof Slab :Ground Floor
j)RCC Parapet for Balcony Ground Floor
k)Stair case : Ground Floor
l)Shelve Ground Floor
a)Column First Floor
b)Lintel :First Floor
c)Chajja First Floor
d)Fin First Floor
e)Roof Beam :First Floor
f)Roof Slab : First Floor
g)RCC Parapet for Balcony First Floor
h)Stair case : First Floor
i)Shelve First Floor
a)Column Second Floor
b)Lintel :Second Floor
c)Chajja Second Floor
d)Fin Second Floor
e)Roof Beam : Second Floor
f)Roof Slab : Second Floor
g)RCC Parapet for Balcony Second Floor
h)Stair case :Second Floor
i)Shelve Second Floor
a)Column Terrace Floor
b)Lintel : Terrace Floor
c)Chajja Terrace Floor
d)Roof Beam : Terrace Floor
e)Roof Slab : Terrace Floor
Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / TATA / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including all cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Terrace Floor
Providing 12mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with all cost, conveyance, royalties, with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect and specification and direction of the Engineer in charge. Ground Floor
First Floor
Second Floor
Terrace Floor
Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with all cost, conveyance, royalties, with cost of all labour,labour cess, T&P and scaffolding required for the work etc. complete in all respect as per direction of the Engineer-in-charge . Ground Floor
First Floor
Second Floor
Terrace Floor
Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with all cost, conveyance, royalties, with cost of all labour,labour cess, T&P and scaffolding required for the work etc. complete in all respect as per direction of the Engineer-in-charge . Ground Floor
First Floor
Second Floor
Terrace Floor
Supplying, fitting & fixing of Granite Tiles of minimum 20mm thick and size above 0.40 sqm of approved make in floors over 20mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect and as per direction of the Engineer-in-charge Ground Floor
First Floor
Second Floor
Supplying and Fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour & size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP- 63:2018 and as per the direction of Engineer-in-charge. Ground Floor
Supplying, fitting & fixing of Vitrified colour printed series tiles of thickness 8mm to 10mm in floors of size 600mm x 600mm of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour, labour cess, T&P etc. required for the work all complete as per direction of the Engineer-in-charge Ground Floor
First Floor
Second Floor
Supplying, fitting & fixing of Vitrified colour printed series tiles of thickness 8mm to 10mm in dadoes, skirting and risers of steps of size 600mmx 600mm of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour , labour cess, T&P etc. required for the work all complete as per the direction of the Engineer-in-charge Ground Floor
First Floor
Second Floor
Supplying fitting and fixing of ISI marked 35mm thick flush door shutters confirming to IS: 2202 (Part-1) decorative type core of block board construction with frame of first class hard wood and well matched teak three ply veneering with vrtical grains or cross bands and face veneers on both face of shutter of approved design and quality including cost of all door fittings and fixtures etc. Complete as per direction of Engineer in charge. Ground Floor
First Floor
Second Floor
Terrace Floor
Supplying, fitting, fixing of two track UPVC Sliding Window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fittings and fixtures etc complete as per direction of Engineer in charge. Ground Floor
First Floor
Second Floor
Terrace Floor
Supplying of G.I. Grills/shutter of approved quality and design to windows and openings and staircase railing and parapet railings etc including making holes in walls and RCC structures or wood work etc in proper position making good the damages of walls or RCC or other structures complete including bending or cutting sizes or grooves in chowkhats with all cost and conveyance of all materials labour , labour cess with T&P required for the work and royalities etc.complete (including screws) in all respect in all floors as per the direction of Engineer-in-Charge . Ground Floor
First Floor
Second Floor
Terrace Floor
Priming one coat with approved Water Bound Wall cement Primer on Plastered Surface including sand papering, cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge. Ground floor
First Floor
Second Floor
Terrace Floor
Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including sand papering, cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge Ground floor
First Floor
Second Floor
Terrace Floor
Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion "Royale Shyne" of Asian Paints or equivalent of approved shade as per the instructions of the manufacturers; giving uniform shade etc in all heights of walls etc. including interior wall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge. Ground Floor
First Floor
Second Floor
Terrace Floor
Painting two coats with approved enamel paints of approved colour, shade over a coat of primer over new/ old new wood and Iron work including all cost of primer and paint, sand papering, polishing the surface, all cost, conveyances of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge. Ground Floor
First Floor
Second Floor
Terrace Floor
Supplying, fitting and fixing hand railing of Stainless steel of 304 grade using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with all cost, conveyance, taxes of all materials, cost of all labour, T&P etc. required for the complete in all respect as per direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Providing fitting fixing of false ceiling with Aluminium anodised T section No.3215 with 2'0" center to center, L section No.1705 on 4 walls to be fixed by means of steel screw and P.V.C. plug and the Aluminium grid 2'0"x2'0" with water proof Gypsum board suspended from ceiling including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge Ground Floor
First Floor
Second Floor
Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor. Terrace Floor
Providing and laying plain cement concrete of proportion (1:2:4) in foundation and floors using 12 mm. size hard broken granite chips and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including all cost, conveyance, royalties and cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge. Terrace Floor
INTERNAL ELECTRICAL WORK Internal Wiring including supply of all required materials Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 6Amp, 250V Modular switch(Legrand mylinc/ Schneider clipsal/Panasonic (vision) ) ISI marked and ceiling rose ISI marked mounted on metal box having front Modular cover of suitable size, metal box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection.(Make of wire-L&T/Anchor/Havells/V-Guard/Great White/HPL) Single light point controlled by one 6A switch or first light point or group control - Group-A .
Single light point controlled by one 6A switch or first light point or group control - Group-B .
Single light point controlled by one 6A switch or first light point or group control - Group-C .
Recessed wiring to exhaust fan point - Group-B .
Recessed wiring to call bell point - Group-B .
Recessed wiring to ceiling fan point including fixing of 5" dia ceiling fan box with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire-Finolex/ L&T/ Anchor/ Havells) & fixing of 5" dia ceiling fan box. (Space shall be provided for installation of electronics type stepped fan regulator)
Wiring for 2way 6A switch / Twin control light point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess PVC conduit with 2 way clip in modular type switch with ISI marked suitable size G.I modular box box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard ) Group C
Supply & fixing of 5 / 6 amp socket outlet on existing switch board with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge.
Supply, fixing with recessed wiring to 5 / 6 amp socket outlet on separate board 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.
Supply & fixing of 2 x 6 amp socket outlet for TV controlled by , 250 V clip in type switch modular ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge.
Supply, delivery, installation & testing of following plug boards including interconnections and making good the damages caused complete as required and as per direction of Engineer-in-charge. 6 / 16 ampere plug boards consisting of a 16 amp clip-in type modular switch with indicator and a 6/16 amp clip-in type modular shuttered plug socket fixed on metallic concealed box (for Kitchen,W/Mc )
6 / 16 ampere plug boards consisting of a 6/16 amp clip-in type modular shuttered plug socket fixed on metallic concealed box (for Geyser & AC outlet near IDU)
6 / 16 ampere switch boards consisting of a 16 amp clip-in type modular switch with indicator fixed on metallic concealed box (for Geyser)
25 ampere switch boards consisting of a 25 amp clip-in type modular DP switch with indicator fixed on metallic concealed box (for AC)
Wiring for circuits & submain with following number & sizes of FRLS PVC insulated 1100 volt grade multistranded copper conductor wire run inside 2mm thick PVC conduit pipe recessed in ceiling/ column/ walls of building including supply of all materials such as wires, PVC conduit, junction box & pull box etc complete with making good the damages caused as required and as per direction of Engineer-in-charge Inverter wiring to essential light points, Fan points, 6A plug points with 1.5-sqmm FRLS PVC insulated 1100 volt grade multi-stranded copper conductor wire for phase run inside existing 2-mm wall thick non-metallic PVC conduit pipe of circuit wiring, recessed in wall of the building complete as required and as per direction of Engineer-in-charge.
Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For subsequent point of group control )
Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (From BDB to Switch Board & 16A socket points )
Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (From BDB to A/C points )
Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For BDB-CS )
Distribution Board Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted following sizes, SPN, MCB, DB siutable for, 240 V, Single phase 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below. (But without MCB/RCCB/ Isolator) (make- L&T / Legrand / Schneider or equvalant reputed make) 12 Way SPN double door, MCB DB
Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted following sizes TPN , MCB DB suitable for 415 V, 3phase, 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.(But without MCB/ RCCB/ ISOLATOR) (make- L&T / Legrand / Schneider or equvalant reputed make) 6 Way (6 + 18) Double Door, Horizontal type
Supplying and fixing 40Amps rating,C series,10KA breaking capacity, DP 240 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years.
Supplying and fixing 63Amps rating,C series,10KA breaking capacity ,DP 240 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The MCB should be Replacement Warranty will be 3 years.
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
Cabling Work Supply of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade Al. conductor cable of following size. direct in ground including excavation , sand cushioning protective covering and refilling the trench etc.or on surface / on existing cable tray as required. ( Polycab / Finolex / Havells / Rhino / RR Kabel ) 2 core x 6 sqmm
Supply of materials and end termination of following cables including supply of single compression brass cable glands, cable sockets etc complete as required and as per direction of Engineer-in-charge. 2 core x 6 sqmm
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of following sizes on LAYING OF CABLE ON SURFACE as required. MV cable laying up to 25 sq.mm in ground
Fittings & Fixtures Supply, delivery, installation and testing of following types of fluorescent tube fixtures directly on wall / ceiling of building with all accessories such as electronics ballast, lamps, stove enamelled box, perpex sheet cover etc complete assembly and making connection from the suitable point outlet as per the direction of Engineer-in-charge.( For Common Service Areas) Angle Holder with 9 watt led bulb as per make approved by Architect/ Consultant.
Bulk Head Light fixture as per make approved by Architect/ Consultant. (Inside Lift Shaft)
1x18watt Celling Light as per make approved by Architect/ Consultant.(prefer company phillips / havels)
1x12watt Celling Light as per make approved by Architect/ Consultant.(prefer company phillips / havels)
1 x 20 watt LED tube fixtures as per make approved by Architect/ Consultant.(prefer company phillips / havels)
Supply and fixing of 70 W LED Street light (Make-Havells/ Cromption/ wipro/ panasonic/ Philips)
Supply, installation,testing and commissioning of 10Ltr storage type Gyser make - crompton
Supply, delivery, installation and testing of following sweeps of High Speed energy efficient A.C. ceiling fan complete with fan blades, down rod, canopies, capacitor etc including supply of sundry materials, making connection from the suitable point outlet but excluding cost of fan regulator complete as required and as per the direction of Engineer-in-charge. (Usha - striker/ Crompton - Super breeze Deco/ Havells - samraat/ Orient - pspo/ Or equivalent) 900 mm sweep
1400 mm sweep
Supply, delivery, installation & testing of electronic type stepped fan regulator fixed on existing sheet metal switch board including interconnections and making good the damages caused complete as required and as per direction of Engineer-in-charge.
Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required.
Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required.
Supply, Installation, Testing & Comissioning of 1550 VA/ 12V IGBT based .(Make: MICROTEK - Heavy duty UPS 1550 SW / LUMINOUS /Eq as per directio of E.I.C).
supply and fixing of 12 v , 200AH battery make -EXIDE- 6EL200 / EQ As per direction of E.I.C
supply and fixing of Battery rack for Battery / EQ As per direction of E.I.C
Earthing Supply of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. (ForQtrs 6Nos & Electrical Room 4nos)
Supply of materials and laying under ground / floor / wall including making end termination and testing of 6 swg G.I. wire for loop earthing of equipments, switch boards & panels as required complete as per direction of Engineer-in-charge.
Building Lightning Protection Earthing with G.I earth pipe 3 meter long 50 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required
Supply and fixing of lightning conductor finial made of 25mm dia 1000 mm long, G.I tube,having single prong at top,with 85mm dia 6 mm thick G.I base plate including holes etc. complete as required
Supply and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
Fixing of G.I tape 20 mm x 3 mm thick on parapet or suface of wall for lightining conductor complete as required. ( For horizontal run)
Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required.
Supply and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required.
Safety Equipments Supplying, installing and commissioning of ISI ABC Powder 4 Kg Fire Extinguisher containing Mono Ammonium Phosphate Powder 50, Stored Pressure Type,Pressure Gauge, fittted with discharge hose, wall mounting bracket etc., Discharge Time less than 15 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 8A, B Rating 34B, Can Construction : Deep drawn & Co2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, ISI approved as per IS:15683:2006(Make: superimax/Cese fire/Minimax)
Supplying, installing and commissioning of CO2 Type 4.5 Kg Fire Extinguisher containing Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, fittted with discharge hose, wall mounting bracket etc., Discharge Time less than 15 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 8A, B Rating 34B, Can Construction : Deep drawn & Co2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, ISI approved as per IS:15683:2006(Make: superimax/Cese fire/Minimax)
Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket.
Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
EXTERNAL ELECTRICAL WORK Supply of All-In-One Solar LED Streetlight luminaire with System lumen output of 8500 lumens. System Efficacy should be 180lm/W. Maximum Power Consumption should be 47W. AIO luminaire should have minimum 75Wp Mono Solar Panel with 12.8V 30AH LiFePo4 Battery.ithium Ferrophosphate (LiFePo4) Battery (BIS approved) which shall be inside the extruded aluminium luminaire housing (Theft retardant type), Battery should have lifeclass of minimum 2000 cycles with inbuilt BMS system.CCT should be 5700K (+/-500K) and CRI should be 70. The luminaire shall be with PIR sensor.The complete system & BMS should be designed to provide 2 nights (24 Hrs) back up in dimming mode by activating PIR sensor and battery should be kept inside the luminaire and Mono Crystalline Panel (Made in India ) to be mounted on the top of the luminaire housing. The luminaire must be having IP 65 protection for critical component like (LED compartment, Driver compartment & Battery) . The AIO street light is having IK 08 protection except for panel .The luminaire should have the provision the tiltable/ adjustable mounting bracket to mount it on the top of the pole directly. Warranty on the AIO street lights must be 5 years . The solar lighting company must be having in house Lab accriditted by NABL , Lighting design team and service facility in Odisha to provide immediate after sales service within warranty period. LM79 report from 3rd party NABL accredited lab must be substantiating Lumen output and system Efficacy. (Make-philips/havells/panasonic/equi as per direction of E.I.C.),
Supply and errection of 5mtr long Galvanised Octagonal pole having 3.1mm thick, 70mm of top outer dia and 155mm bottom outer dia with decorative double arm of 40mm dia, inbuilt junction box arrangement with base plate of 250X250X16 mm thick and foundation bolt with Anchor plate complete with nut bolt with PU Coating(Make-Velmont/Bajaj/Utkarsh/Skipper/equi as per direction of E.I.C.)
Constructing R.C.C. M-20 grade with 20mm and down grade C.B. chips of approved quality from approved quarry including hoisting, laying hire charges of concrete mixture, vibrator, watering, curing and cost of all materials and labour, T&P centering shuttering etc complete but excluding cost of reinforcement complete. foundation bolt & nut template (M-20,600 mm long) for erection of the above pole
Internal PH Works Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC/upvc pipes and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) In ground floor 20mm dia CPVC pipe
25mm dia CPVC pipe
25mm dia UPVC ASTM-D Pipes
32mm dia UPVC ASTM-D Pipes
In first floor 20mm dia CPVC pipe
25mm dia CPVC pipe
25mm dia UPVC ASTM-D Pipes
32mm dia UPVC ASTM-D Pipes
20mm dia CPVC pipe In second floor
25mm dia CPVC pipe In second floor
25mm dia UPVC ASTM-D Pipes In second floor
32mm dia UPVC ASTM-D Pipes In second floor
40mm dia UPVC ASTM-D Pipes In second floor
50mm dia UPVC ASTM-D Pipes In second floor
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground floor
In first floor
In second floor
Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge(3 layer) Fixing 2000Ltr Roto-moulded water storage tanks-On the roof of second floor.
Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. In Ground floor
In first floor
In second floor
Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge 15mm dia long body Bib Cock cock (Jaquar)-CON-CHR-107KN
15mm dia Two way Bib Cock (Jaquar)-CON-CHR-041KN
15mm dia CP angle stop cock (FLR-ACR-5053N)
20mm dia CP consealed stop cock(Jaquar)-CON-CHR-087KN
Revolving Shower with arm Jauar Cat NO--OHS-CHR-1709
25mm dia CPVC Ball valve(Supreme/Ashirvad)
32mm dia CPVC Ball valve(Supreme/Ashirvad)
40mm dia CPVC Ball valve(Supreme/Ashirvad)
50mm dia CPVC Ball valve(Supreme/Ashirvad)
15mm dia CP flange
15mm dia CP extension piece
HAND SHOWER (HEALTH FAUCET) WITH 1 METER (Jaquar- ALD-CHR-565
15mm dia CP Pillar cock (Jaquar)CON-CHR-021KN
15mm dia CP SINK cock (Jaquar)FLR-CHR-5347N
Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge 250mm to 375mm thick wall
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge 110mm dia U-PVC SWR pipe(Supreme/Ashirvad/Oriplast)
110mm U-PVC door Tee
110mm dia U-PVC Plain Tee
110mm U-PVC door bend
110mm U-PVC plain bend
110mm dia U-PVC plain shoe bend
110mm dia U-PVC offset without ear
110mm dia U-PVC 'P' trap
110mm dia U-PVC cowl
125mm dia CP grating
PVC clamp suitable for 50mm to 110mm dia pipe
50mm dia UPVC class- IV pipes
75mm dia U-PVC SWR pipe(Supreme/Ashirvad/Oriplast)
75mm dia U-PVC Plain Tee
75mm U-PVC plain bend
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral Por S trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with S trap plain (Parryware/Hendware/Cera/Somany/Kerovit)
Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. 580mmx440mm size Orissa pan ((Parryware/Hendware/Cera/Somany/Kerovit)
Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Parryware/Hendware/Cera/Somany/Kerovit)
Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge 600x450x250 mm stainless steel kitchen sink (Jayna make)
Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in charge 550mm x 400mm size W. H. Basin with Pedestal (Parryware/Hindware/Somany)
Half pedestal Basin(Hindware)No.91049+91115
Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge Design mirror(Parryware)
Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mmx600mm long CP towel rail(Jaquar make-AHS-CHR-1501)
CP Towel Ring (Jaquar) ACN-CHR-1121N
Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge 600mmx125mm size glass shelf with C.P guard rail
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
In first floor
In second floor
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
In first floor
In second floor
Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1"-6" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge. In first floor
In second floor
Providing and laying Vitrified floor tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. In ground floor
In first floor
In second floor
Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. (Glazed tile of size 60cmx30cm Kajaria/Somany/Johnson/Orient Bellto be pre-approved by the Engineer in charge) In ground floor
In first floor
In second floor
Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter with FRP frame of size 45x90mm. (Fiber space/ Darwaja/Tarini doors/Trinayan composits/SM doors) In ground floor
Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge Inside size 250mmx250mm
Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class KB brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Inside size 760mmx760mmx460mm
R.C.P.C Cover(18" round man hole cover)
Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Inside size 910mmx910mmx910mm
R.C.P.C Cover(24" round man hole cover)
Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Brick masonry soakway pit 1.40m dia x 2.00m deep
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class-3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturers specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge 110mm dia alround concrete
160mm dia alround concrete
Construction of 50 users RCC septic tank- 1 No Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge.
Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. 1x6.10x2.70x0.30
Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department.
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor (inside/outside)
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor (inside/outside)
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs up to 4.30m height
R.C.C beams,columns,girder and bressmer etc.
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge in F&P
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge 1x2x(5.80+2.40)x0.30x2.00
Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge 160mm U-PVC plain Tee
Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete.
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U-PVC SWR pipes(Supreme/Ashirvad)
110mm U-PVC cowl
(Sinking of 150mm size tube well through hand boring( water jet) method) Suplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge
Supplying all labour, T&P and transporting the boring pipes, top casing, grouting pipes, PVC pipes and fittings, PVC well screens, cement, bentinite and gravels etc to the worksite including loading and unloading etc all complete as per direction of the Engineer in charge.
Supplying all labours, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kind of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets ( whenever required) etc and withdrawing the boring pipes, washing and keeping the bore logging if required all complete as per direction of Engineer in charge Drilling pilot bore from 0 to 360 metres
Supplying all labour, T&P and reaming the pilot bore to the following sizes and depth without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction off Engineer in charge. Reaming 100mm to 150mm dia from 0-360 mtr
Reaming 150mm to 200mm dia from 0-360 mtr
Reaming 200mm to 300mm dia from 0-360 mtr
Supplyimg all labour, T&P and jointing materials & lowering the 300mm dia top casing pipes into the position and removing the same after all complete as per direction of Engineer in charge From 0-360 mtr
Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 150mm dia PVC casing pipe from 0 to 360 metres
Cost of 150 mm dia PVC ASTM pipe(sch-80)
Cost of 150mm dia Slott Cutting
150 mm dia C.I.end/top cutter plug
Cost & Conveyance of bentonite powder
Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction off the Engineer in charge. Labour charges
Cost and Conveyance of gravel
Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack all complete as per the direction of the Engineer in charge. Labour charges
Cost and Conveyance of sand
Supplying all labour, T&P including developing the tube well with compressor ( supplied by contractor ) continuiously worked till clear & adequate discharge is obtained from the tube well including supply and use of necessary equipments and labour as per direction of the Engineer in charge. Labour charges
Supplying all materials , labour, T&P and providing & fixing to wall or ceiling and floor pvc pipes confirming to HDPE pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction. 32mm dia HDPE Pipe
Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submerisble electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trail running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 1.50 single phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.P.M with outlet dia of 32mm
DOL Control panel
32mm dia steel short piece
Well cap
50mm size CI bracket
2.50 sqmm flat cable
Steel rope with cover
20mm dia rigid UPVC pipes
Supplying all materials, labour, T&P and providing & electrification to submerssible pump sets and service connection including fitting fixing of electric board & Switch etc all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T & P and constructing Bore well protection chamber of the inside size 650x650x1000 hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g. chips, 12mm thick cement plaster (1:4) inside and outside, RCC cover slab in (1:1.5:3) using 12 mm size h.g. chips, earthwork in excavation in all kind of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction pof the engineer in charge.
Construction of 30000 Liters RCC Under ground Reserver of Inside size- 5.00 X 3.00 X2.40m Earth work in excavation of foundation in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge. UGR - 1x6.90x4.90x1.50=50.72
-do- with Ist disintegrated rockadditional depth of 1.50 m over the initial lead and lift UGR - 1x6.90x4.90x1.10=37.19
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. UGR - 1x6.90x4.90x0.20=6.76
Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. UGR - 1x5.70x3.70x0.10=2.11
Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. @ 120 kg / cum =
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. RCC floor roof, chajja etc Roof Slab-
RCC Beam, Column, wall etc
RCC Plinth bend/ Raft Base slab 2(5.7+3.7)x0.50
Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site.
Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. Quantity same as item No-4
Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge(18" round man hole cover)
Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 1.50 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110 L.P.M with outlet dia of 25mm For Sump
DOL Control panel
2.50sqmm flat cable
Construction of 6.75mx3.60m x 1.40m(h) Rain water harvesting system- 1 Nos. Sinking of tube well through waterjet method(Hand Boring) Drilling 150mm dia- 0.0m to 30.00m
Reaming 100mm to 150mm dia from 0-360 mtr Reaming 100mm to 150mm dia from 0-360 mtr
Reaming 150mm to 200mm dia from 0-360 mtr
Reaming 200mm to 300mm dia from 0-360 mtr
Supplyimg all labour, T&P and jointing materials & lowering the 300mm dia top casing pipes into the position and removing the same after all complete as per direction of Engineer in charge From 0-360 mtr
Lowering of PVC casing pipe inside bore. 150mm dia- 0.0m to 30.00m
Cost.of 200mm dia (Sch.80)Pipe
Cutting slot in casing pipe for recharge of rain water
Labour for packing gravel outside the tube well 1x25.0mx22/28{(0.40)²-(0.20)²}=2.35
Cost of washed gravel.
Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge Roof slab
Supplying all materials, labour, T&P and providing reinforced cement concrete work of M-25 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Providing and filling filter media 40mm size bolder-1x1x6.0x2.50x0.85=2.75
20mm size washed gravel-1x1x6.0x2.50x0.40=6.00
Course sand-1x1x6.0x2.50x0.30=4.50
Providing fitting and fixing M.S.grill,Jalli cover over the harvesty pindi
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_2.pdf
PDF • 3.07 MB
Tendernotice_1.pdf
PDF • 1.61 MB
BOQ_574122.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid