Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹38.3 L+₹2.5 L (7.03%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹38.8 L+₹3.0 L (8.34%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹39.6 L+₹3.8 L (10.6%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹40.1 L+₹4.3 L (12.0%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹33.2 L
EMD Value
₹66,400
Closing Date
2 Nov 2021, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPL REPAIRS TO BLDG NO. T-227 AND PROVN OF CATTLE FENCING WITH SECURITY LIGHTS NEAR BLDG NO. PB-24 AT KANCHRAPARA UNDER GE BARRACKPORE
2021_MES_481495_1
8572/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹66,400
Yes
30 Nov 2021
13 Oct 2021
4 Nov 2021
13 Oct 2021
2 Nov 2021
28 Oct 2021
Amount
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed.
Taking down chowkats or frame (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down chowkats or frame (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surface channel and drains etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) used as in bed block, hold fast, coping, door cills and like etc including necessary form work complete all as specified and directed.
M&L for cutting chases, in brick wall, pinning in and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing etc and making good the disturbed surface, cutting not exceeding 10cm girth complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
S&F for second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints of second class hard wood etc complete all as specified and directed.
S&F for second class hardwood small fittings such as brackets of any type, latch and hinge blocks, shapes door and window stops and the like including all necessary articles not exceeding 200 Cucm each complete all as specified and as directed.
S&F for 35mm thick (factory made) plain, second class hard wood, framed, panelled shutters (three panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F for 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
S&F for factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified and directed.
S&F for 18-20 mm thick PVC solid board with one side decorative choice laminated and other side balancing white as in kitchen cabinate, cupboard etc fixed with screw to steel/timber frame work etc complete all as specified and directed.
S&F for 300mm long, MS ordinary rat tail rod pattern spring including roller & roller plate as in repair complete all as specified and directed.
S&F for 300 mm aluminum alloy, anodised, sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F for 125 mm long aluminium anodised hasp & staple safety type including hinge pin, bolt to hinge plate etc complete all as specified and directed.
S&F for 50 mm long stainless steel butt hinges complete all as specified and directed.
S&F for 75 mm long stainless steel butt hinges complete all as specified and directed.
S&F for 25mm dia aluminium, powder coated (wood colour finished), single curtain rod (wall thickness not less than 1mm) including funnels etc as in repair complete all as specified and directed.
S&F for MS bracket (heavy duty), powder coated of best quality as approved by GE suitable for fixing 25mm bore curtain rod (CP) fixed in wall complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F for mild steel hold fast/wind tie made out of flat iron (25mm x 3mm or equivalent size) including tarring or coal tar black paint and with drilling necessary holes etc conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing of Fe-410 (Gde E-250) quality 'A' complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including where required drilling, fittings, riveting or welding connecting with fish plate, gusset plates etc of Fe-410-W (Gde E-250) quality 'A' complete all as specified and directed.
S&F for bands, straps, supports or stays for rainwater, ventilating pipes including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fast, wind ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-e-165 complete all as specified and directed.
S&F for angle iron works as in post and struts in fencing post including cutting tops to shape as directed, drilling holes, bolting or riveting, notching for wire etc conforming to Fe. 290 Gde E-165 complete all as specified and directed.
S&F for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5 cm but not exceeding 10 cm long with dia meter of neck 11 to 15mm dia complete all as specified and directed.
S&F for pressed steel frames (factory made) for door of size 165mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded crushed stone aggregate) with and including applying of two coats of black bituminous paint (shop coat) to back of chowkats complete all as specified and directed.
S&F for pressed steel frames (factory made) for door of size 105mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded crushed stone aggregate) with and including applying of two coats of black bituminous paint (shop coat) to back of chowkats complete all as specified and directed.
S&F for pressed steel frames (factory made) for door of size 75mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded crushed stone aggregate) with and including applying of two coats of black bituminous paint (shop coat) to back of chowkats complete all as specified and directed.
S&F for steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed
Supply only MS round bars 10mm dia for securing chain link fencing fixed to RCC/mild steel fencing posts as per Fe-410-W (Gde- E-250) quality 'A' or Fe-290 (Gde E-165) complete all as spccified and directed.
S&F for galvanised iron chain link fencing with 4 mm dia of wire made up into matresses with mesh of any size and type and fixed with 10 mm dia MS round bars and straining including provision of binding wire for securing chain link fencing complete all as specified and directed. (Note: 10 mm dia MS round bar shall be measured and paid separately as supply only)
S&F for anodized aluminium frame for window with one or more rebates, anodized aluminium window, sliding type shutters, sliding on three way aluminium channel, without sash bars, sliding on separate track, made out of aluminium section weighing 0.55 Kg/RM and necessary jointing cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, fittings such as suitable anodized aluminium locking type handle etc. with and including supply and fixing of 4mm thick sheet glass, tinted for two channels and stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm for one channel to make the window fly proof complete all as specified and as directed.
S&F for anodized aluminium frame for window with one or more rebates, anodized aluminium window, sliding type shutters, sliding on two way aluminium channel, without sash bars, sliding on separate track, made out of aluminium section weighing 0.55 Kg/RM and necessary jointing cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, fittings such as suitable anodized aluminium locking type handle etc. with and including supply and fixing of 4mm thick sheet glass, tinted for two channels complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws after and including dismantling of existing unserviceable sheet complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws after and including dismantling of existing unserviceable sheet complete all as specified and directed.
S&F for false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee gird false ceiling using “T” Gird System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board (Make: Everest, type/pattern -oceanic or equivalent of Armstrong/Charminar) of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T gird Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Gird module to form after and including dismantling of existing unserviceable false ceiling complete all as specified and directed.
M&L for 18/19 mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber or steel frame work for cupboard shutter/shelves complete all as specified and directed.
M&L for roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove, dust etc complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection & hard standing including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 100mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate), as in sub base of floor complete all as specified and directed.
M&L for 40 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor complete all as specified and directed.
M&L for 25mm (avg) thick PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in roof padding / levelling course with WPC as per manufacturer's instructions complete all as specified and directed. (Note : WPC shall be measured and paid separately).
M&L for 18-20 mm thick granite slab (of any type) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the of granite stone including grinding and polishing over and including 15 mm thick screed bed of cement mortar (1:6) complete all as specified and directed.
M&L for 18-20mm thick granite (of any type) tiles machine cut, in wall/pillar/skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including a backing coat of 10mm thick plastering in cement mortar (1:4) complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
All as per Item No.64.00 here-in-before but in skirting/dado over and including a backing coat of 10mm thick cement plaster in cement mortar (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface of size 450 mmX 300 mmX7 mm thick or equivalent set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering of cement mortar (1:4) complete all as specified and directed.
M&L for 20-22mm thick machine cut kota stone slab flooring (pre-mirror polished) over and including 20mm thick screed bed of cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 20-22mm thick machine cut kota stone slab in riser of steps, skirting, dado and pillar laid over and including 10mm cement plastering in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for pre-polished coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for 20 mm thick rendering in wall, 1st coat 15mm thick in cement mortar (1:6) & 2nd coat 5mm thick in cement mortar (1:4) mixied with water proofing compound as per manufacturer's instructions, plastered surface shall be finished even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately, WPC shall be used in second coat only)
M&L for applying three coats of white wash on wall surface including preparation of new plastered surface complete all as specified and directed.
M&L for applying three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and directed.
M&L for two coats of white wash on old plastered surfaces of wall after preparation of old plastered surfaces complete all as specified and directed.
M&L for two coats of white wash on old plastered surfaces of ceiling after preparation of old plastered surfaces complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of cement based paint on old plastered surface of walls after complete removal of existing treatment complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty on old decorated plastered surface of wall after and including complete removal of existing treatment and preparation of surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick wall care putty on wall after preparation of newly plastered surfaces of walls complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer after preparation of new steel surfaces of any description not exceeding 10 cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth complete all as specified and directed.
M&L for preparing new or previously untreated small articles and applying two coats of synthetic enamel paint over one coat of pink primer such as rafter feet, brackets or cantilevers not exceeding 30 cm projection and blocks, labels, etc. not exceeding 0.1 sqm each complete all as specified and directed.
S&F for 4mm thick figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm each pane complete all as specified and directed.
S&F for 15mm dia bib taps, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed as in repair complete all as specified and directed.
S&F for 15 mm bore angular stop valve, fancy type, chromium plated , cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions as in repair complete all as specified and directed.
S&F for 15 mm bore stop valve, fancy type chromium plated with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions as in repair complete all as specified and directed.
S&F for 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes as in repair complete all as specified and directed.
S&F for brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges as in repair complete all as specified and directed.
S&F for15 mm dia PVC connection pipe of length 600 mm with PTMT nuts as in repair complete all as specified and directed.
S&F for 125mm size brass chromium plated shower roses with arms, swivel joints, including fixing to steel pipe or union as in repair complete all as specified and directed.
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
S&F for 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for 15 mm bore pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for 20 mm bore pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
S&F for 20mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe & fixed (minimum weight 210 gms) as in repair complete all as specified and directed.
S&F for 1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer), ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
S&F for vitreous china wash basin, white, flat back, size 550 X 400 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand as in repair complete all as specified and directed.
S&F for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor as in repair complete all as specified and directed.
S&F for vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:5:10) type E2 using 40mm nominal brick ballast and connection to trap with cement mortar, and making good to floor after and including demolition of PCC / lime concrete bedding of existing pan as in repair complete all as specified and directed.
S&F for 32mm waste coupling of PTMT (half and full threaded) (minimum weight 45gms) as in repair completed all as per specified and directed.
S&F for sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm as in repair complete all as specified and directed.
S&F for 125mm dia grating doom with waste hole , fancy type, chromium plated complete all as specified and directed.
S&F for stainless steel kitchen rack plate of size 900mmX600mmX250mm, 1mm thick, fabricated type with all fixings accessories as in repair complete all as specified & directed.
S&F for 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB, urinal etc. complete all as specified and directed.
S&F for 50mm bore high density polyethylene pipes (HDPE) of pressure rating 6kgf/cm2 fixed complete to wall, ceiling or in floors etc. complete all as specified and directed.
S&F for 100mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, laid in trenches or in floors or fixed to walls after and including dismantling of existing pipe complete all as specified and directed.
S&F for 75mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, laid in trenches or in floors or fixed to walls after and including dismantling of existing pipe complete all as specified and directed.
S&F for 100 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) complete all as specified and directed.
S&F for 75 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) complete all as specified and directed.
S&F for 100 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) fixed with oval access door complete all as specified and directed.
S&F for 75 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) fixed with oval access door complete all as specified and directed.
S&F for 100mm dia CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F for 100mm dia CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access door complete all as specified and directed.
Taking down existing electric meter carefully from the meter box and re-fixed the same in the existing or new location including supply and fix PVC enclosed for meter box alongwith suitable cut out complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of top cover , blanking plate as per numbers of switches, sockets, fan regulators, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as sunken box, top cover , blank plate, MS box, screws, washers etc are to be used of same make/brand only and cost of the same shall be deemed to be included in quoted rate only.)
One light point controlled by one switch .
One ceiling fan/exhaust fan point controlled by one switch .
One bell/buzzer point controlled by one bell push.
One light point controlled by two Nos two way switches .
One 3 pin 5 amps socket point controlled by one 6 amps switch on independent board .
One 3 pin 5 amps socket point controlled by one 6 amps switch on same board .
All as per Item No.122.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15/16 Amps socket outlet on independent board complete all as specified and directed .
S&F for stepped type (0-4/5 step) electronic fan regulator for ceiling fan 1200 mm, 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F for bell push switch, single pole, one way, flush type, 6 Amps, 240 volts, ISI marked complete all as specified and directed.
S&F for call bell, AC, 230 Volts single pole, buzzer type ISI marked complete as in repair all as specified and directed.
S&F for ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 and15/16 Amps, 240 volts, AC, ISI marked complete all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F for switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F for switch piano flush button single pole one way 15/16 amp 240 volts, AC, ISI marked complete all as specified and directed.
S&F for switch piano, flush type, single pole, two way, 5/6 Amps, 240Volts, AC, ISI marked complete all as specified and directed.
S&F for batten holder /angle lamp holder, PVC/polycarbonate type, ISI marked complete all as specified and directed.
S&F for decorative box type 20 -22watt LED fitting with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC as approved for LED lamp as approved)
S&F for 36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable with and including street light bracket made out of GI pipe of 40mm dia medium grade bent to shape of 1.2 mtr long including clamps made out of 40 mm x 6 mm flat iron for fixing bracket including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer after and including taking down street light fittings alongwith brackets complete all as specified and directed. (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED as approved)
S&Ffor LED flood light fitting of capacity 100 Watt in aluminium PDC housing with LED lamp, toughened glass cover with IP66 protection with 4/5 KV inbuilt surge protector and cable connection from looping box to light fitting at any height and testing complete all as specified and directed . (Make:-Crompton Cat ref No.CFS-504-100-57-60D-SL-GL-NSG/Havells cat No. JETAIRISFLS100WLED757APWBLTG /Bajaj Cat No.BJFL 100W LED I or equivalent model of Surya as approved)
S&F powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat as in repair complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08D / L&T Cat No.DBSPN008GD as approved)
S&F for powder coated sheet metal enclosure with metal type acrylic door, 415 volts, AC, VTPN DB (V-vertical type distribution board) 4 way plus 24 modules, for flush mounting with 200amps copper busbar, 2 neutral/earth bar for ease of installation and MCCB incomer of rating upto 200Amps, FP and MCB SP /TP MCB's as outgoing and complete connecting cable links with top and bottom with IP43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat as in repair complete all as specified and as directed. (Make: Legrand cat No.5077 30, 4 way / Hager Cat No.VYVO4DM-P / L&T Cat No.DBVTH004DD as approved)
S&F for MCB SPN 32 Amps, 10 KA, 'C' series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed.
S&F for MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
S&F for MCCB, 63 Amps, 3 pole, 16KA breaking capacity Icu at 415 Volt with thermal magnetic release, 50 Hz after and including taking down existing unserviceable MCCB complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically (earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value complete all as specified and directed. (Galvanised iron wire of 4mm dia upto 7.5m including testing consider in this item).
M&L for rigid steel conduit welded having external dia meter of conduit 20mm , ISI marked fixed with steel tubular poles upto 9 mtr long with suitable size of MS clamp and nuts and bolts etc and applying two coats of aluminium paint over a coat primer complete all as specified and directed.
S&F for heavy duty type exhaust fans AC single phase 230/240 V of size 300 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects complete all as specified and directed. (Make : Havells model No Turbo Force SP 300mm-900RPM or equivalent model of Crompton Greaves as approved)
S&F for ceiling fan of size 1200 mm sweep, high speed, single phase, 240Volts, AC, 50Hz, BEE 5 Star rated as approved colour and including hanging GI hook with necessary suitable MS clamps and connecting cable three core 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing after and including taking down ceiling fan from existing position and deposited to MES Store Yard complete all as specified and directed. (Make:- Havells model No. Samraat or equivalent model of Crompton Greaves/Usha/Bajaj as approved)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 35 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking down existing cable of any type and any size complete all as specified and directed . (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for 1100 KV grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire one 2 core cable flat or circular of size 4 Sqmm multi stranded conductor complete all as specified and directed.
Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points as in soft/loose soil all as specified and directed.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed.
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
M&L for providing cement concrete (1:4:8), type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling for poles complete all as specified and directed
M&L for providing cement concrete (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work after and including taking down of old existing one complete all as specified and directed . (Note : Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit and chase cutting shall be measured as one unit)
S&F for water storage heater (geyser) of 25 ltrs capacity, vertical type with copper inner tank, 240 volts, BEE 5 Star rated, AC, 50Hz and fixing arrangement on wall including providing hole fastners-04 nos, hot & cold water PVC pipes 15 mm bore approximate 600 mm long -2 Nos, chromium plated brass stop cock 15 mm bore -01 No and including necessary plumbing work, tesing complete all as spcified and directed. (Make: Havells/Crompton Greaves /Racold as approved)
M&L for GI pipe 50mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection complete all as specified and directed.
M&L for GI pipe 40mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, on wall, floors, on roof, on pole for cable protection complete all as specified and directed.
M&L for boring holes horizontally under road without damaging the surface of road (minimum 1.0m bellow the road surfaces) with the help of GI tubing of any dia not exceeding 100mm dia for passing of UG cable complete all as specified and directed.
S&F for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified conforming to IS- 2317/1980 type 410 SP-31 (9 metres long) complete with cast iron base plate including staying the poles in a truly vertical position till the foundations are properly set, including painting to pole (inside & outside) with two coats of aluminium paint on exposed surfaces of poles and two coat of black bituminous paint on embedded portion complete all as specified and directed. (Note: Excavation, foundation concrete and coping will be measured and paid separately)
S&F for hot press moulded SMC junction box of size 350mm X250mm X150mm hinged type with incoming and outgoing connector/terminals-04 Nos of 415 Volt -TPN and comprising of MCB, SP, 6 Amps, 240V, 10KA, 'C' Series and including MS flat iron clamps of size 25X5mm thick -02 Nos, nuts, bolts & washers etc for fixing on Steel tubular pole complete all as specified and directed. (Make:- Sintex/Hensel )
INDUSTRIAL CONSTRUCTION
M/S D K Singha
TIMBA
CHATTERJEE ENTERPRISE
B.N. SADHUKHAN
M/S KARTICK CHANDRA CHAKRABORTY
S..S. ELECTRIC CO.
DE CONSTRUCTION CO
R N CHATTERJEE
RISING ENTERPRISE
M/S H.P Singha
TAMALIKA ENTERPRISE
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .