| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC D NO 38 22 40 NEAR LAKSHMI NARASHIMA THEATER 104 AREA VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹48.3 L+₹1.9 L (4.14%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L2 | Rejected-Finance NOT LOWEST TENDER | |
| 3 | L3₹48.8 L+₹2.4 L (5.19%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L3 | Rejected-Finance NOT LOWEST TENDER | |
| 4 | L4₹49.1 L+₹2.7 L (5.92%)Rejected-Finance D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L4 | Rejected-Finance NOT LOWEST TENDER | |
| 5 | L5₹49.7 L+₹3.3 L (7.06%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST TENDER |
| Sl No | Description | Qty | Unit | M/s DIAMANTO VERTICALS L5 | SRIVALLI ENGINEERS L4 | AYYAPPA CONSTRUCTIONS L1 | M/S CHANDRA ENGINEERS AND CONTRACTORS L2 | LAKSHMI SAI CONSTRUCTIONS L6 | GVR CONSTRUCTIONS L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00NOTES/INSTRUCTIONS FOR STRICT COMPLIANCE (a) The contractor shall obtain sample approval for all materials for incorporating in the work as per condition 10 of IAFW-2249 and Para-12 of Special Conditions of tender document mentioned here-in-after. (b) The GE may direct the contractor in writing to procure and deposit up to 80% of the material required for the complete scope of work. The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material under intimation to GE to the store of concerned subdivision within 30 days from the receipt of written direction. Failure to do so shall result in a penal recovery of Rs 2000/- per week, levied on the dues of contractor, maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as plumber, welder, helper etc readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge/GE | |||||||||
| 1.01NOTES(Contd---) (e)The breakdown/Leakeges should be attended well within time mentioned here-in-after from the time of intimation (through Verbal/Site Order/Written) by the Engineer-in-Charge/GE, failing which a penal recovery of Rs 500/- per hour shall be deducted from contractors dues: Size of Pipe Time limit to attend Breakdown & Completion Upto 50mm 6 Hrs 50mm-100mm 8 Hrs More than 100mm 12 Hrs (f) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery, Arrangements of Manual Dewatering/Dewatering pumps and Temporary lighting arrangements for work during night time etc as per site requirement. (g) The quoted rates shall be inclusive of cost for necessary scaffolding for working upto 9th floor level of multi-storyed Buildings under AoR of GE (U-II). | |||||||||
| 2.00 | Material and labour for Stainless steel Single Headed Oblique Type Hydrant Valve (Type 'A') with Cast Iron operating wheel, Inlet 80mm & Outlet 63mm Instantaneous, IS:5290, ABS Blank Cap including taking down unserviceable hydrant valve of any description, complete all as specified and directed by Engineer-in-Charge. | 20 | Each | 4,050 ₹81,000 Lowest | 8,610 ₹1,72,200 | 8,500 ₹1,70,000 | 8,450 ₹1,69,000 | 8,520 ₹1,70,400 | 8,500 ₹1,70,000 |
| 3.00 | Material and labour for Stainless steel Double Headed Oblique Type Hydrant Valve (Type 'B') with Cast Iron operating wheel, Inlet 100mm & Outlet 63mm Instantaneous, IS:5290, ABS Blank Cap including taking down unserviceable hydrant valve of any description, complete all as specified and directed by Engineer-in-Charge. | 30 | Each | 5,500 ₹1,65,000 Lowest | 18,050 ₹5,41,500 | 17,000 ₹5,10,000 | 17,440 ₹5,23,200 | 20,000 ₹6,00,000 | 18,800 ₹5,64,000 |
| 4.00 | Material and labour for 63 mm dia instantaneous Male & Female Coupling stainless steel as per IS:903. including taking down unserviceable coupling of any description, complete all as specified and directed by Engineer-in-Charge. | 12 | Each | 1,405 ₹16,860 Lowest | 1,750 ₹21,000 | 2,000 ₹24,000 | 1,890 ₹22,680 | 1,912 ₹22,944 | 1,900 ₹22,800 |
| 5.00 | Material and labour for stainless steel hand controlled Nozzle hydraulically crimped to hose with metal crimping, Spray and Shut off functions, Operating at 10 bar working pressure, with 20mm diameter including taking down unserviceable nozzle of any description, complete all as specified and directed by Engineer-in-Charge. | 40 | Each | 675 ₹27,000 | 460 ₹18,400 | 350 ₹14,000 Lowest | 450 ₹18,000 | 455 ₹18,200 | 460 ₹18,400 |
| 6.00 | Material and labour for PCC (1:3:6) type C2 using 40 mm graded stone aggregate as a base foundation for the pipe lines including one coat of white wash and necessary form work complete all as specified.
Note:- The quoted rates shall be inclusive of removing the damaged PCC base foundation, levelling surface as directed. | 2 | Cum | 9,000 ₹18,000 | 8,010 ₹16,020 | 6,000 ₹12,000 Lowest | 7,800 ₹15,600 | 7,910 ₹15,820 | 7,900 ₹15,800 |
| 7.00 | S & F in repair single hydrant stand post made of MS pipe of size 80 mm bore heavy grade, 1.50 m height with 90°, duck foot bend both end flanged and including welding if required to suit single/ double fire hydrant valve and testing, complete all as specified and directed. | 6 | Each | 4,500 ₹27,000 Lowest | 8,210 ₹49,260 | 7,000 ₹42,000 | 8,250 ₹49,500 | 8,290 ₹49,740 | 8,300 ₹49,800 |
| 8.00 | Taking down & refixing the old fire hydrant valves of size 63/80mm dia from hydrant post and removing the corrosion, changing the damaged pins from pivot end, softening the shaft of iron wheel and applying the greese for lubrication of fire hydrant valves, complete all as specified and directed.
Note:- The quoted rates shall be inclusive of Nut & Bolts, rubber gaskets and other connected items. | 20 | Each Job | 1,800 ₹36,000 | 1,100 ₹22,000 | 1,000 ₹20,000 Lowest | 1,150 ₹23,000 | 1,169 ₹23,380 | 1,160 ₹23,200 |
| 9.00 | Repair/ maintenance of fire hose box by changing of damaged doors along with locking arrangements, front glass of existing size, PCC foundation and necessary rubber gaskets for doors complete all as directed by Engineer-in-Charge.
Note:- The quoted rate shall be inclusive of one coat red-oxide paint, paint red and inside clean white paint and numbering of box as directed. | 30 | Each Job | 1,431 ₹42,930 | 590 ₹17,700 | 1,000 ₹30,000 | 550 ₹16,500 Lowest | 580 ₹17,400 | 580 ₹17,400 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
10 Sept 2025, 6:00 pmClosed
Garrison Engineer Utility-II Visakhapatnam
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
REPAIR/MAINTENANCE OF FIREFIGHTING SYSTEM, FIRE HYDRANT VALVES, BOX, FIRE PUMPS/ MOTOR AND CONNECTED MICS WORKS AT NAVAL BASE AREA AND ADJACENT AREAS UNDER GE (U-II) VISAKHAPATNAM
2025_MES_726567_1
8107(A)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer Utility-II Visakhapatnam
As per NIT Conditions
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Utility-II
₹90,000
Yes
11 Oct 2025
19 Aug 2025
11 Sept 2025
19 Aug 2025
10 Sept 2025
5 Sept 2025
19 Aug 2025 - 26 Aug 2025
Amount
NOTES/INSTRUCTIONS FOR STRICT COMPLIANCE (a) The contractor shall obtain sample approval for all materials for incorporating in the work as per condition 10 of IAFW-2249 and Para-12 of Special Conditions of tender document mentioned here-in-after. (b) The GE may direct the contractor in writing to procure and deposit up to 80% of the material required for the complete scope of work. The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material under intimation to GE to the store of concerned subdivision within 30 days from the receipt of written direction. Failure to do so shall result in a penal recovery of Rs 2000/- per week, levied on the dues of contractor, maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as plumber, welder, helper etc readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge/GE
NOTES(Contd---) (e)The breakdown/Leakeges should be attended well within time mentioned here-in-after from the time of intimation (through Verbal/Site Order/Written) by the Engineer-in-Charge/GE, failing which a penal recovery of Rs 500/- per hour shall be deducted from contractors dues: Size of Pipe Time limit to attend Breakdown & Completion Upto 50mm 6 Hrs 50mm-100mm 8 Hrs More than 100mm 12 Hrs (f) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery, Arrangements of Manual Dewatering/Dewatering pumps and Temporary lighting arrangements for work during night time etc as per site requirement. (g) The quoted rates shall be inclusive of cost for necessary scaffolding for working upto 9th floor level of multi-storyed Buildings under AoR of GE (U-II).
Material and labour for Stainless steel Single Headed Oblique Type Hydrant Valve (Type 'A') with Cast Iron operating wheel, Inlet 80mm & Outlet 63mm Instantaneous, IS:5290, ABS Blank Cap including taking down unserviceable hydrant valve of any description, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Stainless steel Double Headed Oblique Type Hydrant Valve (Type 'B') with Cast Iron operating wheel, Inlet 100mm & Outlet 63mm Instantaneous, IS:5290, ABS Blank Cap including taking down unserviceable hydrant valve of any description, complete all as specified and directed by Engineer-in-Charge.
Material and labour for 63 mm dia instantaneous Male & Female Coupling stainless steel as per IS:903. including taking down unserviceable coupling of any description, complete all as specified and directed by Engineer-in-Charge.
Material and labour for stainless steel hand controlled Nozzle hydraulically crimped to hose with metal crimping, Spray and Shut off functions, Operating at 10 bar working pressure, with 20mm diameter including taking down unserviceable nozzle of any description, complete all as specified and directed by Engineer-in-Charge.
Material and labour for PCC (1:3:6) type C2 using 40 mm graded stone aggregate as a base foundation for the pipe lines including one coat of white wash and necessary form work complete all as specified. Note:- The quoted rates shall be inclusive of removing the damaged PCC base foundation, levelling surface as directed.
S & F in repair single hydrant stand post made of MS pipe of size 80 mm bore heavy grade, 1.50 m height with 90°, duck foot bend both end flanged and including welding if required to suit single/ double fire hydrant valve and testing, complete all as specified and directed.
Taking down & refixing the old fire hydrant valves of size 63/80mm dia from hydrant post and removing the corrosion, changing the damaged pins from pivot end, softening the shaft of iron wheel and applying the greese for lubrication of fire hydrant valves, complete all as specified and directed. Note:- The quoted rates shall be inclusive of Nut & Bolts, rubber gaskets and other connected items.
Repair/ maintenance of fire hose box by changing of damaged doors along with locking arrangements, front glass of existing size, PCC foundation and necessary rubber gaskets for doors complete all as directed by Engineer-in-Charge. Note:- The quoted rate shall be inclusive of one coat red-oxide paint, paint red and inside clean white paint and numbering of box as directed.
Material and labour for ISI marked non-percolating flexible firefighting delivery hose of length 15 meters, synthetic fiber circular woven jacketed, bearing IS:636-2018, 63 mm dia, complete with stainless steel instantaneous male & female coupling (IS:903), and Copper Wire binding including taking down unserviceable firefighting delivery hose of any description, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Swinging Hose reel Type-A, Wall Mounted with 180° swing, specifications as per IS-884: latest revision made of high quality mild steel, powder coated in red colour, Hub width approx 230 mm, Maximum operating pressure 10 bar, Flow rate 22.5 lpm at 7 bar pressure including taking down unserviceable hose reel drum of any description, complete all as specified and directed by Engineer-in-Charge.
S & F in repair two way fire brigade inlet connection with isolation valve with instataneous gun metal coupling 63mm dia complete all as per fire standards made out of 150mm dia class 'B' MS pipe, complete all as specified and directed.
S & F in repair four way fire brigade inlet connection with isolation valve with instataneous gun metal coupling 63mm dia complete all as per fire standards made out of 150mm dia class 'B' MS pipe, complete all as specified and directed.
Material and labour for Fire Hose Box fabricated from 18 gauge CR sheet with double door, with full front glass inspection window and locking arrangement (Common Key Lock), duly painted with PO Red colour outside and white colour from inside (two coats of synthetic enamel paint), Size 30"X24"X10", 3mm thick Acrylic glass, (Suitable to accommodate 2 lengths of 15mtr, Hoses & 1 no. branch pipe with Nozzle) including taking down unserviceable fire hose box of any description, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Fire Hose Box fabricated from 18 gauge CR sheet with double door, with full front glass inspection window and locking arrangement (Common Key Lock), duly painted with PO Red colour outside and white colour from inside (two coats of synthetic enamel paint), Size 24"X18"X10", 3mm thick Acrylic glass, (Suitable to accommodate 1 lengths of 15mtr, Hoses & 1 no. branch pipe with Nozzle) including taking down unserviceable fire hose box of any description, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Stainless Steel Short Branch pipe, with 63mm male instantaneous inlet, male threaded outlet, with 20mm bore hexagonal base nozzle, bearing IS:903 mark including taking down unserviceable branch pipe of any description, complete all as specified and directed by Engineer-in-Charge.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as directed by Engr-in-charge.
M&L for construction of brick masonary valve chamber of following dimensions with angle iron frame and MS sheet cover 3mm thick duly painted 2 coats of red oxide/ zinc chromate primer including lifting handle, locking arrangement, excavation and earth work, plastering including dismantling of old valve chamber of any size and taking out rusted MS sheet with angle iron frame, complete all as specified and directed:-
900 mm x 900 mm x 900 mm
1200 mm x 1200 mm x 1200 mm
Supply and fix FRP Composite for following sizes OHT / UG Water Tank Cover made of standard designs conforming to IS:1726-1991, having load bearing of 2.5 TON including frame, complete all as specified and directed:-
90 cm x 90 cm
60 cm x 60 cm
45 cm x 45 cm
Labour for pressure testing of existing 150 mm DI/MS fire main system , identifying for leakages for rectifications including replacement of gland packing of sluice valves, rubber insertion packing, nut ,bolts etc of flanged joints/ defective flanges etc complete for making the system leak proof, complete all as specified and directed. Note:- (a) The rate quoted shall deemed to be inclusive of T&P such as air compressor for pressure testing etc (b) Earthwork, DI/MS pipe & specials required for rectiifcation shall be measured and paid separately under relevant items BOQ.
Excavation in trenches in soft/lose soil n.exc. 1.5M wide & n exc 1.5M deep for laying of GI/CI pipe line & getting out including forming bottom surface, complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layer n.exc. 250 mm in any type of soil after the pipe laid & tested, complete all as specified and directed.
Removing excavated surplus soil to a distance n.exc. 50mtr and depositing where directed at a level n.exc. 1.5 m above the starting point, complete all as specified and directed.
Material and labour for Overhauling to Jockey pump set and motor 20 HP to 35 HP as per the original assembly after replacing the worn out unserviceable parts,including cleaning replacing the bearings for both pumps & motors including packing bolts, nuts washers and MS clamps etc and applying one coat of approved enamel paint on exposed steel surface, making the pump and motor fully serviceable including machine work etc and testing the both after refixing and commissioning for satisfactory operation on its full load, complete all as specified and directed.
M&L for disconnecting and removing the existing defective Mono block / centrifugal pumpset motor of any make of following capacity from the installed position by putting dummy plate to suction and delivery removing the burnt out winding and re-winding the same with super enamelled copper wire of same gauge and same No of turns of existing make insulating winding with existing class of insulation varnishing baking up including replacement of base foundation nuts, bolts and re-installation of pump, testing to satisfactory performance, complete all as specified and directed:- Note :- Bearings, CI gland plates, Terminal block, shaft shall be measured and paid separately under relavent items of BOQ
100 HP to 125 HP
40 HP to 80 HP
Upto 20 HP
M&L for overhauling of centriifugal pump set of following capacities of any make, dismantling and taking down pump after disconnecting water supply connections,decoupling from motor removing out impeller, cleaning, descaling, greasing to bearings incl replacement of unserviceable parts such as bearings DE & NDE, pump shaft sleeves, coupling pully, pump shaft etc. Assembly in the pump with new packing materials, nuts, bolts& washers , gland bolt & packing,coupling bushes, coupling bolts and coupling with motor checking for vibration & alignment connecting delivery and suction pipe, testing the pump set, complete all as specified and directed:- Notes:- (i) The cost of small U/S parts such as new packing materials, nuts, bolts & washers , gland bolt & packing, coupling bushes, coupling bolts shall deemed to be included in quoted rates (ii) The major unserviceable spares as listed shall be measured and paid separately as supply only.
100 HP to 125 HP
40 HP to 80 HP
Upto 20 HP
M&L for replacement of pumpset coupling star/ rubber with rubber band, nuts and bolts for the following capacity, complete all as specified and directed:-
Upto 20 HP
M & L in repairs for gland packing of required size gland superior quality to centrifugal / monoblock pumps of following capacities all as specified and directed :-
Upto 20 HP
Supply only ball bearings suitable for centrifugal and mono block pumps motors as existing at site, complete all as specified and directed:-
Upto 20 HP
Supply only CI gland plate high tension studs for Centrifugal / mono block pumps for the following capacity, complete all as specified and directed:-
Upto 20 HP
Supply only CI impeller suitable for centrifugal / mono block pumps for the following capacities, complete all as specified and directed:-
Upto 20 HP
Supply and fix 3 pole power contactor of existing model for AC 415 Volts, 50 Hz, 3 Phase suitable for electric motor of following capacity including removing existing unserviceable one from star delta starter, complete all as specified and directed:-
100 to 125 HP capacity.
40 to 80 HP capacity.
20 to 35 HP capacity.
Upto 20 HP
Supply and replace burnt bimetal over load relay suitable for the following capacity of motor starters as existing at site, complete all as specified and directed:-
100 to 125 HP capacity (relay range 180-300 Amps)
40 to 80 HP capacity (relay range 45-75 Amps)
20 to 35 HP capacity (relay range 20-33 Amps)
Upto 20 HP
Supply and replace Pump Shafts as per existing Model with necessary metal filling and machine suitable for the following capacity of pump sets, complete all as specified and directed:-
Upto 20 HP
20 to 35 HP capacity
40 to 80 HP capacity
100 to 125 HP capacity
Supply and replace Casing ring for Centrifugal / mono block pumps for the following capacity, complete all as specified and directed:-
Upto 20 HP
20 to 35 HP capacity
40 to 80 HP capacity
100 to 125 HP capacity
Supply and replace unserviceable brass air cock of suitable size to pump sets, complete all as specified and directed
Labour only for attending break down of CI/DI/MS pipe line upto 200 mm bursting / cracks and including cleaning / removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes, CI / DI Collar / mechanical Joints etc as per site requirement, testing for leakages of lead joints, testing and necessary dewatering, complete all as specified and directed by Engr-in-Charge. Note 1 :- The quoted rate shall be deemed to be included the following:- (i) Arrangement of suitable Pump sets for dewatering at the time of attending break down. (ii) Necessary labour/trade men for attending break down. (iii) Labour element required for fixing CI/DI/MS pipes, specials, fittings etc. Note 2 :- M & L for Lead joints, DI/ MS pipes, specials, fittings and Excavation will be measured and paid seperately under relevant items.
Burning out lead joint in position including removing old lead to store for the following sizes, complete all as specified and directed:-
150 mm bore
200 mm bore
250 mm bore
Material and labour for run lead joint for spigot and socket pipes (CI/DI) and fittings of following sizes, complete all as specified and directed by Engr-in-Charge:-
150 mm dia
200 mm bore.
250 mm bore.
Supply only DI Specials (any type radius and angle) tapers any type straight increasing decreasing or double socket and ''Y junction double branch, Collar, cross (all sockets or socket and spigot) caps and plugs upto 300 mm bore, complete all as specified and directed.
Supply only Ductile Iron pipe of following sizes conforming to IS-8329:2000, with socket & spigot ends, Class "K9" including flexible push on joint in any length laid in trenches, complete all as specified and directed:-
150 mm dia
200 mm dia.
Supply & laying MS ERW pipe of following dia heavy grade for inserting in position, making leak proof joints including fittings and testing the pipe line for leakage, taking down unserviceable including painting with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
200 mm dia
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Supply and fix Sprinkler Quick / Early response type as per IS 15105/TAC guidelines 79 degree temperature rating pendant type including taking town old one, complete all as specified and directed.
All as Srl per item No. 43.00 here-in-before but upright type complete.
Supply and fix flange joint with rubber or fibre board gasket with welding including suitable bolts, nuts and washers for 200 mm NB pipe, complete all as specified and directed.
Supply and fix flange joint with rubber or fibre board gasket with welding including suitable bolts, nuts and washers for 150 mm NB pipe, complete all as specified and directed.
Supply and fix flange joint with rubber or fibre board gasket with welding including suitable bolts, nuts and washers for 100 mm NB pipe, complete all as specified and directed.
Supply and fix flange joint with rubber or fibre board gasket with welding including suitable bolts, nuts and washers for 80 mm NB pipe, complete all as specified and directed.
Supply and lay in repair GI water tubing galvanised medium grade in floors/ on roof /on wall / trenches including all fittings of following sizes, complete all as specified and directed:-
20 mm dia bore
25 mm dia bore
40 mm dia bore
50 mm dia bore
80 mm dia bore
Supply and fix gun metal gate valve with iron wheel head screwed both ends for iron pipe of following size including dismantling old one, complete all as specified and directed:-
20 mm dia bore
25 mm dia bore
40 mm dia bore
50 mm dia bore
80 mm dia bore
M & L for arresting water leakage from sluice valve, by refacing, regrinding of sluice Valve, Repacking stuffing box of sluice valve spindle including taking apart and reassembling the same including replaceing old check nuts with new one made out of MS/CI material, with and including replacing perished gland packing, rubber gasket, bolts and nuts, complete all as directed by Engineer-in-charge.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
S&F in repair Sluice valve of following sizes cast iron body with flanged ends duly drilled ISI marked as per IS (14846-2000) PN - 1.6 with brass spindle and check nut including operating wheel etc. and fixed with new bolts, nuts, washers and rubber insertion packing, complete all as specified and directed:-
200 mm dia
150 mm Dia
100 mm Dia
80 mm Dia
Supply and fix in repair Cast carbon steel non-return valve swing type as per BS.1868 Class -300 & flange drilling ANSI B.16.5 Class-300, with body disc & cover, CCS-SA 216 Gr WCB Body & Disc seat-ring SS-410/304, Hinge pin SS-410, Bolts & nuts SA 193/194 Gr B7/2H etc complete including replacement of perished nuts, bolts, washers and rubber gasket etc.of following sizes, complete all as specified and directed by Engr-in-Charge.
100 mm dia
150 mm dia
200 mm dia
Supply and fix in repair CI foot valve ball type with necessary rubber gasket, bolts, nuts and washers for following size, complete all specified and directed:-
80 mm bore
100 mm bore
150 mm dia.
200 mm dia.
Supply and fix in replacement of CI Butterfly valve of size 150mm nominal bore as per IS 13095, PN 16, wafer type without lugs, suitable for clamping between flanges as per ANSI B 16.1 CI-125, including flanges, fittings, gasket, nuts, bolts, washers etc. including taking up / down of existing unserviceable butterfly valve of any description, complete all as specified and directed.
All as per item No. 55.00 here-in-before but of size 100mm NB
All as per item No. 55.00 here-in-before but of size 80mm NB
Supply and fixing in replacement of pressure switch in IP55 enclosure CE marked suitable to use in auto fire pump control system, permissible operating pressure 18 bar, pressure setting range 4-12 bar and differential 0.5-1.6 bar, pressure connection G 1/4A, with silver contact material, rubber cable gland for cable entry including taking down of existing unserviceable pressure switch of any description, complete all as specified and directed.
Supply and connecting in replacement of 2 core, 2.5 sqmm power cable with copper conductor, PVC insulated, cores laid up, PVC inner sheathed, armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V grade as per IS:1554(Part-1) laid / fixed in cable duct / fixed to walls / steel posts etc including taking out of existing unserviceable control cable of any description, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of 3 phase digital Voltmeter / Ammeter, Cl 0.5 flush mounting suitable for fixing in existing panel, complete all as specified and as directed.
Supply and fixing in replacement of Programmable Logic Control (PLC) system suitable for existing automatic fire fighting pumps control panel, complete all as specified and directed by Engineer-in-Charge.
Labour only for thorough checking of existing automatic fire fighting pump set control system for serviceability of each and every component such as Pressure switches, sensors, gauges, PLC system, electromagnetic power relay, contactors, OLR, Timer, preventor, control wiring, panel accessories etc complete and identifying and replacing the defective components for satisfactory functioning of automatic fire fighting control panel based on pressure sensing in the fire mains by deploying qualified and experienced technician in the relevant field, complete all as specified and directed by Engineer-in-Charge. Note: Spare parts required shall be measured and paid separately under relevant items of BOQ. However, cost of minor spare parts costing up to Rs. 1500/- shall deemed to be included in the quoted rate.
Material and labour for Supply, installation and testing of LED flex Glow Sign Board for frontlit office / installation boards prints stretched on a metal frame, where the sun or the ambient light lends visibility to the board complete comprising of the following components with below given detailed specifications including taking down of existing unserviceable office / installation sign board of any description, complete all as specified and directed:- (i) Metal Frame / Box: The base structure of board should be made of a metal frame in the form of a box of 6 – 8 inches deep and the width and the height and shape of the frame are as per site requirement and as directed by Engineer-in-Charge by using 0.5 – 0.75 inch thick, metal pipes to fabricate the box. (ii) Tin Sheet / Patra: The above box should be wrapped by a tin sheet or ‘patra’ on the back and the sides in a standard black or white colour as directed by Engineer-in-Charge. (iii) LED tubes as a Source of Light: LED tubes as the source of light for GSB, fitted inside the box. Qty of LED tubes shall be as per the manufacturers recommendations based on the size of GSB decided by Engineer-in-Charge.
(Item No 63.00 Contd--) iv) Brackets to Hold the Board in Place: Completed board shall be fitted on wall / metal structure with suitable shaped brackets, nuts, bolts and washers etc and GI wires as per site requirement and as directed by Engineer-in-Charge. (v) Printed Star Flex: The office / installation board design / art work shall be as per sample given by GE / Engineer-in-Charge printed on a specialised media known as Backlit Star Flex 350 GSM with UV ink prints / Eco Solvent ink prints layered in a double strike. This print should has the following characteristics:- Flex is a printable roll of plastic with a cloth like weave on the back. The front surface should specially coated to receive inkjet inks. Print should be waterproof, scratch-resistant and fade-resistant. The denier or the weave on the back lends strength to the print. The weave and printable top layer of backlit flex should be translucent. It should allow light to pass through and when this happens, the print on top gets a very beautiful glow. ‘Star’ is a premium brand of flex. Prints on Star flex have a very high resolution extremely vibrant colours.
(Item No 63.00 Contd--) Note:- (a) The size, dimensions and shape of varying dimensions shall be as per site requirement and as specified and directed by GE / Engineer-in-Charge. (b) The measurement of the completed board shall be measured in square feet on the front face only and hence the quoted rate shall deemed to be included for the depth of the board i.e. 6 to 8 inches. (c) The quoted rate shall be inclusive of cost of transportation to site and installation at any height / in any position and the fixing brackets and accessories and dismantling of existing unserviceable sign board of any description complete all as specified and directed by Engineer-in-Charge.
Material and labour for sun boards or foam boards for offices / installations made of 3 mm-thick foam with a smooth matte printing surface in customisable design templates in any size and shape and printing the details as provided by Engineer-in-Charge as per his directions. The printing shall be done using digital technology that should give the sun board a sharp and professional look. The Vinyl sun boards should have a stiff property with good protection against direct sunlight to avoid colour fading & cracking, resulting in good shelf life. including MS frame as per site condition, complete all as specified and directed by Engineer-in-Charge. Note:- (a) The quoted rate shall deemed to be inclusive of transportation to site and fixing with suitable fixing accessories complete all as specified and directed by Engineer-in-Charge. (b) The measurement of the completed board shall be measured in square feet. (c) Quoted rate shall be inclusive of custom printing charges. (d) Quoted rate shall deemed to be inclusive of dismantling and taking down of existing unserviceable sign boards of any description.
Material and labour for Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment inclusive of one primer coat, one under coat and one finishing coat of paint of approved colour including cutting and removing old corroded MS sheet / plate of any description, complete all as specified and directed by Engineer-in-Charge.
Supply and replace LED tube light fitting alongwith with fixture 22 Watts complete all as specified and directed.
M&L Synthetic mat (rubber matting) suitable for 11000 Volts electrical grade 2mx1mx19mm thick chequered top, ISI marked to be laid in front of LT panel board, complete all as specified and directed.
Servicing of soft starter 415 Volts suitable off size of different capacity installed at various location, dismantling the existing soft starter, servicing the same, replacing the defective spare parts and refixing it at the original place, complete all as specified and as directed by Engr-in-Charge
Supply and replace PVC cooling fan suitable for the existing motors of various capacity including testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
Supply, fixing and testing of soft starter 415 Volts suitable for Pump of capacity 30 to 80 HP in existing LT panel with necessary fixing arrangements including taking down existing unserviceable, complete all as specified and as directed by Engr-in-Charge
All as per Item No. 69 of the above but of capacity 100 HP to 125 HP.
M&L for disconnecting / removing the old unserviceable starters from the panel and supply and fix DOL/ starter Delta Starter for AC, 415V 50 Hz 3 phase suitable for following capacity of electric motor, complete all as specified and directed by Engineer-in-Charge:-
Upto 20 HP
Taking down carefully existing motor and pump set from the unserviceable bed and taking up the complete MS bed from the PCC and cleaning and levelling the bed including new PCC work including with fabrication of new MS bed by using new MS work with foundation bolts and nuts suitable for mounting/re-erecting the pump and motor after necessary minor repairs complete with two coats of existing colour painting over a coat of red oxide and testing and commissioning up to satisfaction levels, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for painting to old painted steel surfaces of Centrifugal/ monoblock Pump sets of following capacity with one coat of synthetic enamel paint including cleaning, scraping foreign material and degreasing surfaces, complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparing new or previously untreated / old painted steel surfaces of water pipe lines of size 200mm dia, in any position, with two coats of synthetic enamel paint over one coat of red oxide primer with & including marking direction of flow / name of feeder, complete all as directed by Engineer-in-Charge.
All as Srl per item No. 75.00 here-in-before but of size 150mm dia
All as Srl per item No. 75.00 here-in-before but of size 100mm dia
All as Srl per item No. 75.00 here-in-before but of size 80mm dia
All as Srl per item No. 75.00 here-in-before but of size 50mm dia
Material and labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, 25x4mm galvanised iron strip including taking down of existing corroded GI earth continuity conductor of any description, complete all as specified and directed by Engineer-in-Charge.
M&L for stone masonry for walling of random rubble, uncaused, well bonded, built in cement mortar 1:4 for construction of thrust block for the support of water supply pipe line including demolition of existing masonry work, complete all as directed by Engr-in-charge.
Supply and fix water pressure gauge standard dia 4" dia dial , Range 0-21 Kgs at the delivery side of pump sets complete tubing, fitted with stop cock etc, complete all as specified and directed by Engineer-in-Charge.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core in conduit pipe of 20/25 mm size complete with PVC rectangular block with 3mm thick for mounting switch/ sockets regulators etc.and with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one light/ fan point controlled by one switch including taking down of old wiring, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 83 above but for 3 pin socket outlet point controlled by one, one way switch on the same board.
All as per serial item No. 83 above but for one 3 pin switch socket combination of 5 Amp capacity on independent board.
All as per serial item No. 63 above but for 3 pin switch socket combination of 15 Amp on independent board with cable 4 sqmm unsheathed stranded 1100 Volts grade complete with 4.0 sqmm PVC insulated earth wire and connecting to earth dolly, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix switch piano type 5 Amp single pole one way, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 2 in 1 , 3 pin 5 Amp flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing stepped type, electronic ceiling fan regulator, complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling rose surface backelite three terminal, complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SPN 240 Volts 32 Amp breaking capacity 10 KA rating, complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating, complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 12 way DB double door with din rail and bus bar including making good to the disturbed surface matching with the existing, complete all as specified and as directed by Engineer-in-Charge.
All as per Serial item No. 93 above but for 08 Way DB.
Supply and fix in repair 3 core 1.5 sqmm PVC copper cable multi stranded drawn through inside pole from the bottom connector to fitting including providing necessary lugs complete incl taking down the existing wire, complete all as specified and directed.
S & F in repair of Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 ltrs hoisted and fixed in position incl dismantling of old water tanks, complete all as specified and directed.
All as per Srl Item No. 96 above but of capacity 1000 ltrs.
S&F in repair MCCB 4 Pole, 415 V, fixed type, 63 to 125 Amps with breaking capacity 16 KA, complete all as specified and directed.
S&F in repair MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 36 KA, complete all as specified and directed.
S&F in repair MCCB 4 Pole, 415 V, 200 Amps with breaking capacity 36 KA, complete all as specified and directed.
S&F in repair MCCB 4 Pole, 415 V, 400 Amps with breaking capacity 36 KA, complete all as specified and directed.
S&F in repair MCB 4 Pole, 415 V,,40 to 63 Amps, C Curve with breaking capacity 15 KA, complete all as specified and directed.
Supply and fix in repair Flood light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
Supply and fixing in repairs water level indicator, 36" dia as per IS and including numbering with radium stickering heavy duty float, counter weight heavy duty driving gear nylon wire fitted in all in GI housing, cutting the RCC slab and making good the slab, painting the exposed surface with two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised iron or steel, earth strip 32 x 6 mm size by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth strip protected by galvanised iron pipe 40 mm bore, medium grade and connected to main switch board or main control board / DG Set as directed and including concrete pit in PCC (1:3:6) type C1, pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 3 of MES Schedule Part- I and testing on completion, complete all as specified and directed.
M & L for servicing of LT panels of any size by cleaning the panel, bus bar chamber with CTC solution, and welding the door using arc welding and fixing hinges, necessary nut and bolts, washers and made it completely functional for open/ close including painting of panel by spraying with two coats of epoxy based paint over a coat of red oxide primer, after cleaning of rusty panel surface both inside/ outside by emery paper and necessary preparation of smooth surface suitable for painting and including checking of incoming and outgoing connections, Re-fixing of existing ACBs & MCCBs, testing & commissioning, connected PCC & frame works, rewiring of control and power wiring with suitable size of FRLS copper cable but not less than 1.5 Sqmm, replacing of various unserviceable ON/ OFF switches, lugs etc making the panel fully functional, complete all as specified and as directed.
Surface dressing in soft/loose soil not exeeding 15 cm deep, across the pipe lines and including site clearence, cutting and cleaning of branches / bushes / plants / grass obstructing the pipe lines / valves / chambers / sumps / OHTs on either sides and water supply Installation area including disposal of materials up to a distance not exceeding 50 m, complete all as specified and directed by Engr-in-Charge.
SCHEDULE OF CREDIT Note :- Amount of Rs. 2,06,400.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
M/S CHANDRA ENGINEERS AND CONTRACTORS (BID ID -3421500)
GVR CONSTRUCTIONS (BID ID -3421417)
SRIVALLI ENGINEERS (BID ID -3421254)
M/s DIAMANTO VERTICALS (BID ID -3421224)
LAKSHMI SAI CONSTRUCTIONS (BID ID -3420672)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .