Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical L2 |
Tender Value
₹1.2 L
EMD Value
₹2,942
Closing Date
6 Feb 2024, 6:00 pmClosed
Assistant Engineer
Assistant Engineer LID EW Section Nenmeni GP
Annual Plan-Electrification and Providing Pumpset at Neelamanga Colony-Proj No 349/2022- 23-General Electrical Work
2024_LSGD_651782_7
AE/LIDEW/NMN/05/2023-24
Open Tender
Electrical Works
Item Rate
270 days
Nenmeni GP
Please refer Tender documents.
8 documents required · 8 mandatory
₹555
₹2,942
Yes
18 Jul 2024
30 Jan 2024
8 Feb 2024
30 Jan 2024
6 Feb 2024
30 Jan 2024
Amount
Electrical
OD278111/2023-2024:Supply, installation testing and commissioning of 5 HP Vertical open well submersible pump set 2880 rpm at rated voltage 3 phase 415V 50HZ AC supply at 16-74 Mtr head delivery size 50 mm or nearest size having 21.6 - 1.8 discharge and 4.5 LPS at 50 Mtrs head using leak proof materials as required and suspended on existing rope/steel rope including fixing G.I. / uPVC Column heavy duty Pipe for Submersible Pumps as delivery pipe connected one by one to the motor up to the bottom of the well using leak proof materials as required with necessary supports on both sides of the motor including giving connection as per the direction at site. (Texmo/CRI/Kirloskar/Deccan)
OD278112/2023-2024:Supply, Installation, Testing and Commisioning of DOL MUG Starter Panel for 5HP Submerssible motor comprising of Relay, LED Indicator, Voltmeter, Ammeter, Contactor, Capacitor etc as required. L&T
OD278101/2023-2024:Supply threading, laying and joining of 50 mm/nearest size Submersible Column/HDPE Pipe for submersible pump, approved make specials as delivery pipe using required leak proofing materials etc. as required.
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD278102/2023-2024:Supply and providing 50 mm/nearest size dia Gun Metal Non return valve (ISI)
OD278103/2023-2024:Supply and providing 50 mm dia Full way valve (ISI)
OD278104/2023-2024:Supply and providing 50 mm dia Flange set
OD278105/2023-2024:Supply and laying of 20mm or nearest size Nylon rope
OD278106/2023-2024:Supply and providing 50 mm stainless steel Hose Collar with hose clip
OD278107/2023-2024:Supply and fixing flat iron clamps made from 2 nos. 50x6 mm flat iron clamp of 50 mm with suitable size bolt and nut for fixing delivery pipe on the top of the well as required
2.17:Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1.14.9:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
OD278108/2023-2024:Supply and installation of dust and vermin proof Three-phase sintex motherboard (GS MB?6535) 650*350*250 and to fix kseb meters, fuse unit, CTs, etc. as required including fixing it on the wall, making good the damages, color washing, etc. as required
OD278109/2023-2024:Supplying and fixing 32A, 2 way Neutral link mounted on DMC/SMC base with connection, in the existing meter board
OD278110/2023-2024:Supplying and fixing 32A, Bakelite HRC fuse with HRC fuse link with connection, in the existing meter board
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
Mahesh KR
Bidder Name
Mahesh KR
RASHEED PK
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .