XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
REPAIR UPGRADATION OF HVAC SYSTEM INSTALLED IN PEDIATRIC OT BLOCK AT GOVT. SMGS HOSPITAL, JAMMU
2024_PWDJK_243677_4
MHDJ/e-NIT 238 of 2023-24
Open Tender
Repair and Maintenance Services
Turn-key
30 days
SMGS HOSPITAL JAMMU
AS PERT E NIT
2 documents required · 2 mandatory
₹1,000
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
₹51,000
2 May 2024
22 Mar 2024
2 Apr 2024
22 Mar 2024
1 Apr 2024
27 Mar 2024
22 Mar 2024 - 1 Apr 2024
Amount
Supply, installation, testing and commissioning of outdoor units equipped with highly efficient scroll /Rotary compressors with ALL INVERTER type compressors only, special acryl precoated heat exchanger, low noise condenser fan, pre coated fin type heat exchangers. The outdoor and indoor units shall be integrated with special super wiring system with a remote controller into one common wiring independent to each outdoors. The Inverter Compressors system should reach full load rapidly providing less temperature fluctuation. Quote shall include imported refnet joints with piping system . Refrigerant should be R410A/Equiv. All structural frame work platforms required shall be of HVAC vendor as per site conditions. The electrical contractor shall leave the required specifications. The unit should operate from -15 °C TO 52 °C outdoor Temperature. The pedestals / MS frameworks for outdoor units shall be included in the quoted price. 12 HP VRF Outdoor Unit (2 Working 01 standby)
Supply, installation, testing and commissioning of outdoor units equipped with highly efficient scroll /Rotary compressors with ALL INVERTER type compressors only, special acryl precoated heat exchanger, low noise condenser fan, pre coated fin type heat exchangers. The outdoor and indoor units shall be integrated with special super wiring system with a remote controller into one common wiring independent to each outdoors. The Inverter Compressors system should reach full load rapidly providing less temperature fluctuation. Quote shall include imported refnet joints with piping system . Refrigerant should be R410A/Equiv. All structural frame work platforms required shall be of HVAC vendor as per site conditions. The electrical contractor shall leave the required specifications. The unit should operate from -15 °C TO 52 °C outdoor Temperature. The pedestals / MS frameworks for outdoor units shall be included in the quoted price. Supply, installation, testing and commissioning of suitable refrigerant controller kit with remote control
Supply, installation, testing and commissioning of outdoor units equipped with highly efficient scroll /Rotary compressors with ALL INVERTER type compressors only, special acryl precoated heat exchanger, low noise condenser fan, pre coated fin type heat exchangers. The outdoor and indoor units shall be integrated with special super wiring system with a remote controller into one common wiring independent to each outdoors. The Inverter Compressors system should reach full load rapidly providing less temperature fluctuation. Quote shall include imported refnet joints with piping system . Refrigerant should be R410A/Equiv. All structural frame work platforms required shall be of HVAC vendor as per site conditions. The electrical contractor shall leave the required specifications. The unit should operate from -15 °C TO 52 °C outdoor Temperature. The pedestals / MS frameworks for outdoor units shall be included in the quoted price. Supply, installation, testing and commissioning of DX COIL (6 ROW DEEP DX COIL WITH SUITABLE 3 Nos CIRCUIT)
Supply, installation, testing and commissioning of outdoor units equipped with highly efficient scroll /Rotary compressors with ALL INVERTER type compressors only, special acryl precoated heat exchanger, low noise condenser fan, pre coated fin type heat exchangers. The outdoor and indoor units shall be integrated with special super wiring system with a remote controller into one common wiring independent to each outdoors. The Inverter Compressors system should reach full load rapidly providing less temperature fluctuation. Quote shall include imported refnet joints with piping system . Refrigerant should be R410A/Equiv. All structural frame work platforms required shall be of HVAC vendor as per site conditions. The electrical contractor shall leave the required specifications. The unit should operate from -15 °C TO 52 °C outdoor Temperature. The pedestals / MS frameworks for outdoor units shall be included in the quoted price. All types of MS Works for Outdoor Units
REFRIGERANT PIPING FOR VRF SYSTEM : SITC of Copper Referigant piping of the required sizes for all the units with refnets as per specs. The insulation shall be of 19mm thick Armaflex/ KFlex make through out the running length of Ref. piping. The piping shall be well supported at specific intervals with GI supports with insulated PUF saddles and Exposed pipes shall be installed on GI cable trays supported from wall / roof with anchor fasteners & C type ms angle. The pipe sizes are tentitive, the vendors have to consider as per their manufacturing standards.Consider PVC Sleeves inplace of PUF Saddles & GI Cable tray is considered only at Terrace exposed area 34.9 mm O.D. (insulation – 19 mm thick)
REFRIGERANT PIPING FOR VRF SYSTEM : SITC of Copper Referigant piping of the required sizes for all the units with refnets as per specs. The insulation shall be of 19mm thick Armaflex/ KFlex make through out the running length of Ref. piping. The piping shall be well supported at specific intervals with GI supports with insulated PUF saddles and Exposed pipes shall be installed on GI cable trays supported from wall / roof with anchor fasteners & C type ms angle. The pipe sizes are tentitive, the vendors have to consider as per their manufacturing standards.Consider PVC Sleeves inplace of PUF Saddles & GI Cable tray is considered only at Terrace exposed area 15.9 mm O.D. (insulation – 19 mm thick)
REFRIGERANT PIPING FOR VRF SYSTEM : Nitrogen &pressure testing & additional gas charing for the entire length of copper pipes-refrigerant R410A environmental friendly refrigerant 1 HP VRF Outdoor Unit
SITC of Control cabling from Indoor to outdoor unit for all the units with the necessary fittings. The cabling shall be FRLS weather proof type as most of the cabling will have open exposure to atmosphere. The cabling shall be bundled properly and shall be neatly aligned with the Refrigerant piping. The cabling shall be well supported at specific intervals and & similar to refrigerant piping. (2 /4core x 1.5 Sq mm cu.cable )
DUCTING & INSULATION WORKS Sheet Metal Ducting Supply, Installation, Testing & Commissioning & Handing over of the following:Rectangular Aluminium ducting – Factory Fabricated complete with splitter dampers, turning vanes, access doors, supports, air tight joints with dual insulation to avoid leakage, applied with sealant etc. as per site requirement. The duct supporting shall be as per SMACNA standards. 22gauge galvanized sheet (0-750mm)
DUCT INSULATION SITC of Acoustic Insulation with 15 mm thick self adhesive open cell nitrile rubber as shown in the drawing ( Arma Cell / K/A/ Flex / Supreme make.)
OLD EXISTING DUCT Dismantle, repair, Reinstalation , Testing & commissioning of old & existing Aluminium duct
SITC of Aluminium volume control dampers constructed with exturded aluminium construction with PVC gear and opposed blades complete with handles, bushes, linkages within the enclosure as per specs. (Shall be suitable for motorised actuation) Rate per Sq.Mt of area
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .