| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹10.7 L+₹13,699 (1.30%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹11.5 L+₹90,805 (8.60%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹11.7 L+₹1.1 L (10.9%)Rejected-Finance JAGAT BERH SRIPALLY PURBA BARDHAMAN WEST BENGAL 713103 | SRIPALLY | PURBA BARDHAMAN | WEST BENGAL | 713103 | L4 | Rejected-Finance L4 | |
| 5 | L5₹12.3 L+₹1.7 L (16.0%)Rejected-Finance P O SASINDA VILL KASHIYA P S BELDA WEST MEDINIPUR PIN 721445 | BELDA | PASCHIM MEDINIPUR | WEST BENGAL | 721445 | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | Messrs HI- Q - ENTERPRISE L2 | FAIRWAY ENTERPRISE L1 | RIDDHI (INDIA) L3 | BARSHA ENTERPRISE L5 | JOY MAA TARA ELECTRICAL CO L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling charges for existing old dist. Wiring, Different type distribution board, computer board, Switch board, fittings, fixture etc. as per direction of EIC. | 1 | job | 6,000 ₹6,000 | 1,250 ₹1,250 Lowest | 9,000 ₹9,000 | 2,500 ₹2,500 | 1,506 ₹1,506 |
| 2.00 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles as to GS.
a) 19 mm dia 3 mm thick polythene pipe with 1x14 SWG GI
earth continuity wire | 256 | RM | 55 ₹14,080 | 63 ₹16,128 | 70 ₹17,920 | 61 ₹15,616 | 27.5 ₹7,040 Lowest |
| 3.00 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed]
a) Average run 8 mtr | 65 | pt | 850 ₹55,250 Lowest | 970 ₹63,050 | 900 ₹58,500 | 950 ₹61,750 | 1,024 ₹66,560 |
| 4.00 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.
a) Average run 8 mtr | 35 | Pt | 900 ₹31,500 | 864 ₹30,240 | 700 ₹24,500 Lowest | 850 ₹29,750 | 1,152 ₹40,320 |
| 5.00 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) do-----do----as per GS..
On Board | 15 | Pt | 200 ₹3,000 | 162 ₹2,430 | 90 ₹1,350 Lowest | 202 ₹3,030 | 256 ₹3,840 |
| 6.00 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
25 mm size | 195 | Mtr | 50 ₹9,750 | 65 ₹12,675 | 45 ₹8,775 Lowest | 65 ₹12,675 | 72 ₹14,040 |
| 7.00 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe/ PVC Rigid Conduit and by the prelaid GI fish wire and making necy. connection as required
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC(For SPN DB) | 195 | Mtr | 105 ₹20,475 | 143 ₹27,885 | 160 ₹31,200 | 100 ₹19,500 Lowest | 228 ₹44,460 |
| 8.00 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 40 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required of 4x16sqmm+2x10 sqmm ECC (from VTPN to HTPN) ( make: Gloster/ Polycab/Havells/as per direction of EIC). | 190 | Mtr | 720 ₹1,36,800 | 866 ₹1,64,540 | 630 ₹1,19,700 Lowest | 750 ₹1,42,500 | 942 ₹1,78,980 |
| 9.00 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2x22/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) (For Separate Board) | 250 | Mtr | 75 ₹18,750 Lowest | 101 ₹25,250 | 90 ₹22,500 | 80 ₹20,000 | 109 ₹27,250 |
| 9.01 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) (For Computer Board Power Board) | 1,450 | Mtr | 90 ₹1,30,500 Lowest | 113 ₹1,63,850 | 135 ₹1,95,750 | 100 ₹1,45,000 | 133 ₹1,92,850 |
Tender Value
Refer Docs
EMD Value
₹27,442
Closing Date
22 May 2026, 11:00 amClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
Electrical Installation work and SITC of air conditioning system for renovation and modification work at room no. 318 and 319 Paschim Banga Ayurved Parishad 3rd Floor Purta Bhawan Salt lake Kolkata-700091 ---EI Work
2026_WBPWD_5013835_1
WBPWD/EE/BED/e-NIQ-182/2025-26 2nd call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Purta Bhawan
Please refer Tender documents.
6 documents required · 6 mandatory
₹27,442
23 Jun 2026
7 May 2026
25 May 2026
8 May 2026
22 May 2026
8 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling charges for existing old dist. Wiring, Different type distribution board, computer board, Switch board, fittings, fixture etc. as per direction of EIC. | 1 | job | - | - |
| 2 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles as to GS.
a) 19 mm dia 3 mm thick polythene pipe with 1x14 SWG GI
earth continuity wire | 256 | RM | - | - |
| 3 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed]
a) Average run 8 mtr | 65 | pt | - | - |
| 4 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.
a) Average run 8 mtr | 35 | Pt | - | - |
| 5 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) do-----do----as per GS..
On Board | 15 | Pt | - | - |
| 6 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
25 mm size | 195 | Mtr | - | - |
| 7 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe/ PVC Rigid Conduit and by the prelaid GI fish wire and making necy. connection as required
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC(For SPN DB) | 195 | Mtr | - | - |
| 8 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 40 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required of 4x16sqmm+2x10 sqmm ECC (from VTPN to HTPN) ( make: Gloster/ Polycab/Havells/as per direction of EIC). | 190 | Mtr | - | - |
| 9 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2x22/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) (For Separate Board) | 250 | Mtr | - | - |
| 9.01 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) (For Computer Board Power Board) | 1,450 | Mtr | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.89 MB
2911_ii.pdf
Tender Documents • 0.50 MB
BOQ_5081696.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .