Loading…
Loading…
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
14 Aug 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS 2
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less: where V= Advertised value of the tender in crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Electrical contractor license: - The contractor should have valid electrical contractor license issued by government and submit along with tender document. If valid electrical contractor license is not submitted along with tender document, then offer will be summarily rejected.
3 conditions · 1 needing a document upload
Bidder / Tenderer should submit GST registration certificate along with PAN card & Bank mandate while bidding / uploading tender documents.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I / We have visited the works site and I / We am / are aware of the site conditions.
Electrical work in connection with (i) Provision of new block station between SBLT- OCH in RKB-JSM Section. (ii) Provision of new block station between THM-JCH in RKB-JSM Section.
GSUELECTG-13of2026-27
GSUELECTG-13of2026-27
Open
Works - General
12 Months
Jodhpur, Rajasthan
₹0
₹3.8 L
14 Aug 2026
23 Jul 2026
31 Jul 2026
165 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,91,51,772.91 | ||
| — | 300.00 | — | — | ||
| Supply of material and wiring of LP/TP/FP/Ex. Fan point with 1.5sqmm PVC single core multi-stranded copper wire insulated concealed in stone/brick masonry wall in19/20 mm PVC conduit with 1.5sqmm PVC wire insulated copper for earth wire 1-way/2-way switch 5/6A as required and good quality ceiling rose including connection (MODULAR)as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,09,431 | |
| — | 40.00 | — | — | ||
| Supply and fixing ceiling of fan regulator electronic type 5-step as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 15,225.6 | |
| — | 20.00 | — | — | ||
| Supply and fixing 12 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC (Inspection: Consignee, Inspection Charges: None) | — | — | — | 5,067.6 | |
| — | 20.00 | — | — | ||
| Supply and fixing 8 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC (Inspection: Consignee, Inspection Charges: None) | — | — | — | 5,462.4 | |
| — | 40.00 | — | — | ||
| Supply and fixing 6 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC (Inspection: Consignee, Inspection Charges: None) | — | — | — | 6,983.6 | |
| — | 40.00 | — | — | ||
| Supply and fixing 4 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC (Inspection: Consignee, Inspection Charges: None) | — | — | — | 7,270.4 | |
| — | 40.00 | — | — | ||
| Supply, install, test & commission of 3Moduler metal flush box with suitable size cover &base frame as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 8,250 | |
| — | 20.00 | — | — | ||
| Supply and fixing 2 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,339.6 | |
| — | 40.00 | — | — | ||
| Supply, fixing and connecting modular type exhaust fan 225/250mm as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 31,860.4 | |
| — | 80.00 | — | — | ||
| Supply, install, test &commission of Modular6amp, 5 Pin Socket as per specifications. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 10,088.8 | |
| — | 200.00 | — | — | ||
| Supply, install, test & commission of Modular6amp one way/SP Switch, ISI marked as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 13,202 | |
| — | 80.00 | — | — | ||
| Supply, install, test & commissioning of Modular 16 amp, 3/3(6Pin) Socket as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 16,216.8 | |
| — | 110.00 | — | — | ||
| Supply, install, test & commission ofModular16 amp one way/SP Switch , 2 Modular ,ISI marked including connection / wiring on lighting switch board as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 15,297.7 | |
| — | 140.00 | — | — | ||
| Supply, install, test &commission of Modular blank plate as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,650.6 | |
| — | 50.00 | — | — | ||
| "B" Class 50 mm dia GI pipe earth Station with digging pit & refilling with charcoal & salt as per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 69,276.5 | |
| — | 50.00 | — | — | ||
| Inspection Chamber with cover as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 19,322 | |
| — | 500.00 | — | — | ||
| Supply & laying of earth connection from earth electrode with 4 mm GI wire properly fixed on wall with wooden gutties etc. as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 5,865 | |
| — | 200.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x6 sq mm PVC insulated multi-strand ( 84 /.30 mm ) copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 25,124 | |
| — | 640.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x4 sq mm PVC insulated multi-strand ( 56 /0.3 mm ) copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm as per specifications attached as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 56,896 | |
| — | 160.00 | — | — | ||
| Wiring of main (for individual qtr.) with 2x4 sq mm 56/.30 PVC insulated multi-strand copper cable in 19/20 mm dia MS conduit pipe to be fixed properly with saddles, gutties & other fixtures and continuous running of PVC insulated copper earth wire as per specifications attached. Including supply of material as required. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 20,827.2 | |
| — | 1600.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x2.5 sq mm PVC insulated ( 36 /0.3 mm ) multi-strand copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,11,712 | |
| — | 1600.00 | — | — | ||
| Supply and Fixing of 20 mm dia medium class P.V.C. Pipe along with accessories as required in recess on walls/roof properly including cutting of wall /roof and making good the damages as per specifications attached. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,30,064 | |
| — | 200.00 | — | — | ||
| Supply and Fixing of 20 mm dia medium class PVC Pipe along with accessories as required in surface on walls/roof properly with saddles and wooden gutties etc. complete as per specifications attached. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 10,652 | |
| — | 400.00 | — | — | ||
| Supply of material & commissioning of PVC casing caping 25X12 mm with accessories for surface wiring as per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 9,796 | |
| — | 2000.00 | — | — | ||
| Supply of 3 Core 2.5 sq. mm PVC Copper Circular Sheathed Cable with Rigid Conductor as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,20,000 | |
| — | 300.00 | — | — | ||
| Assembling, fixing, hanging and making connection of Surface pendent mounted box type tube light fitting/street light fitting as per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 20,577 | |
| — | 220.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-MCB (SP-) 6-32 A (Inspection: Consignee, Inspection Charges: None) | — | — | — | 52,888 | |
| — | 30.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-RCCB - 25 A/30mA (Inspection: Consignee, Inspection Charges: None) | — | — | — | 76,035.6 | |
| — | 24.00 | — | — | ||
| Supply. fixing, testing and commissioning of SPN DB 8-way with provision of incoming MCB of 63A,IP 43/IK09, double door at suitable locations. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 61,504.8 | |
| — | 4.00 | — | — | ||
| Supply, Fixing, testing and commissioning of TPN DB 8-way with provision of incoming MCCB of 125A, IP43/IK09, double door at suitable locations. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 61,675.92 | |
| — | 4.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached- MCCB 4-pole 100/125A, 25 KA (Inspection: Consignee, Inspection Charges: None) | — | — | — | 55,535.6 | |
| — | 4.00 | — | — | ||
| Supply, Fixing of MCB TPN to be provided in the MCBDB including supply of material as required & as per specifications attached-MCB(TPN)-63A (Inspection: Consignee, Inspection Charges: None) | — | — | — | 7,896.08 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 25A,RCBOdouble pole, 30mA with Earth leakage, overload and short circuit protection as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 21,255.3 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 63A,RCBO Four pole, 30mA with Earth leakage, overload and short circuit protection as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 13,403.44 | |
| — | 300.00 | — | — | ||
| Supply of material and wiring of shed TP/FP with 1.5 sq mm single core multi- stranded copper wire PVC insulated in conduit 1.5mm thick 19mm size white colour shall be fixed with junction box TEE and 1.5minsq PVC CU cable insulated multi stranded for earth wire and 5/6A,ceiling rose. The conduit shall be fixed with raw plugs/ tied with 14SWG copper wire including connection as per spec. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 36,039 | |
| — | 400.00 | — | — | ||
| Supply and fixing of PVC cable duct 40 x 60 (w x h) 1 M STD slot greenish gray of standard make as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 41,752 | |
| — | 600.00 | — | — | ||
| Supply, drawing, testing and commissioning of PVC copper wire 6 sqmm as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 21,210 | |
| — | 20.00 | — | — | ||
| Supply of Phenolic top sheet wooden board size 7'' x 4'' with one no. 5x15 amp switch socket combined & one nos. 5 amp switch ISI mark make- Anchor/Vinay/ABB/Cona/Legrand as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,700 | |
| — | 10.00 | — | — | ||
| Supply of Phenolic top mobile charging wooden board size 6''x15'' fitted with 4 nos. switch & 4 nos. socket of 6 amps with internal wiring of 1.5 sq. mm with base plate of both side particle board for mobile with hanging clip as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,480 | |
| — | 27000.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec ( trench work may be on kuchcha/ pucca land and all type of soil as per site requirement and without protective layer of brick). Surface of trench shall be made good in all respect and satisfaction of site engineer. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 10,98,630 | |
| — | 1600.00 | — | — | ||
| laying cable in Air/Wall/Pole with fixture(02 nos. per mtrs) as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 38,912 | |
| — | 80.00 | — | — | ||
| Supplying., laying of GI pipe size 50 mm dia. B class as per IS1239 for cable use as per specification enclosed (Inspection: Consignee, Inspection Charges: None) | — | — | — | 27,540.8 | |
| — | 80.00 | — | — | ||
| Supplying., laying of GI pipe size 100 mm dia. B class as per IS1239 for cable use as per specification enclosed (Inspection: Consignee, Inspection Charges: None) | — | — | — | 54,004.8 | |
| — | 27000.00 | — | — | ||
| Supply & laying of HDPE pipe of 75/80mm dia, wall thickness3mm. The work involves laying of HDPE pipe & laying cable in HDPE pipe. As per specification (Inspection: RITES, Inspection Charges: To be borne by Railways) | — | — | — | 27,75,060 | |
| — | 2000.00 | — | — | ||
| Drilling of horizontal bore below track/road by pushing method for laying of RCC/HDPE/DWC pipe of various sizes (As per specifications) (Inspection: Consignee, Inspection Charges: None) | — | — | — | 28,48,800 | |
| — | 2000.00 | — | — | ||
| Supply & laying of HDPE pipe, dia 160 mm under road/ground/floor/railway track or as per site requirement in already excavated trench. (As per specification) (Inspection: RITES, Inspection Charges: To be borne by Railways) | — | — | — | 15,80,320 | |
| — | 2000.00 | — | — | ||
| Laying, connecting & commissioning of cable in pipe/trench etc. with complete lug, glands & transportation of cable etc. as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 4,84,220 | |
| — | 40.00 | — | — | ||
| J' type cable route marker made of cast iron as per approved Railway drawing. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 8,692.8 | |
| — | 98.00 | — | — | ||
| Supply, fixing, testing and connecting of wall mounted heavy duty Air Circulator of 24''(600mm) size with built in 3 speed regulator, delivers Air 280Cu.m/min, similar to M/s Almonard make with all accessories complete confirming to IS specification with latest amendments. The Air Circulator is to be fixed by suitable MS clamps of size 50x50x6mm / flats of size 40x6mm with bolts and nuts etc., complete as desired by site engineer. (Inspection: RITES, Inspection Charges: To be borne by Railways) | — | — | — | 9,89,614.78 | |
| — | 40.00 | — | — | ||
| Supply, Testing & Fixing of wall mounted cabin fan with regulator three speed, suitable for 220- 230 volt ,50HZ AC supply .Model No-Media BW 04 of Bajaj or similar to Usha/ Crompton Greaves /Philips . (Inspection: Consignee, Inspection Charges: None) | — | — | — | 78,820 | |
| — | 120.00 | — | — | ||
| Supply and provide MS flat of iron size40x3mm with spacers and fixing clamps as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 17,925.6 | |
| — | 80.00 | — | — | ||
| Fixing of ceiling fan with clamp, hooks and down rod as per requirement and connection as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 15,028.8 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing and commissioning of Distribution Board double door, 3-phase and neutral with incoming 63A 4-pole MCB and outgoing 12Nos. MCB 6-32A single pole as per spec. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,02,434.6 | |
| — | 87.00 | — | — | ||
| Supply and fixing casing caping of PVC size 75x75mm and 2mm thick with suitable nut bolts for fixing or tied with copper wire 14swg for 5/7 nos. of copper wire & earth wire as per spec. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 11,814.6 | |
| — | 115.00 | — | — | ||
| Supply fabrication, erection, testing and commissioning of G.I. octagonal pole 5 mtrs. long double arm suitable for street light fixture, 2 x 36w including digging of pit, making foundation and muffing with cement, concrete 1:2:6. As per specification. (Inspection: RITES, Inspection Charges: To be borne by Railways) | — | — | — | 11,98,747.35 | |
| — | 45.00 | — | — | ||
| Supply, Erection of 7 mtrs high single arm hot dip galvanized Steel Octagonal "Smart poles" with galvanized base plate of 220 x 220 x 12 mm Foundation PCD 205 & Bolt size (4x20 mm dia X 700 mm) length in position including excavation of pit and filling the same with concrete 50 cm ground level from base plate mounting including supply of material as required The pole shall be galvanized internally & externally by single dipping method .Make BAJAJ Model BOP -7030, GE, Crompton Greaves, Philips or similar to this model. (Inspection: RITES, Inspection Charges: To be borne by Railways) | — | — | — | 5,54,186.7 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing and commissioning of fabricated Feeder Pillar distribution box made of MS sheet 1.6mmthick size 600x300x600mmwith suitable MS stand Copper bus bar of 200Acapacity and 2x63A MCB 4pole as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,16,812.8 | |
| — | 8.00 | — | — | ||
| Supply installation, testing and commissioning of 0.5 HP Mono block Pump as per specification (Inspection: Consignee, Inspection Charges: None) | — | — | — | 50,536.24 | |
| — | 8.00 | — | — | ||
| Supply, fixing, testing & commissioning of AC single phase static Energy Meter 5-30 A capacity to measure & display of unit (KWH), Ampere (I), Voltage (V), Load (KW), maximum demand (KW) including last six month history of Energy etc. of accuracy class 1.0, 240 V, 50 Hz with backlit LCD display confirming to IS:13779 or latest. Make: Indotech, L&T, HPL, CG, Genus. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 20,012.88 | |
| — | 8.00 | — | — | ||
| Supply, Fixing testing and commissioning of Key Card Switch 2M with Key Tag 40 Amp, 230 V, 2NO 2 M white plate, Flush Box, contactor and SP/DP plastic enclosure, Make Legrand or similar (Inspection: Consignee, Inspection Charges: None) | — | — | — | 35,490.4 | |
| — | 4.00 | — | — | ||
| L.T. Panel-I Manufacturing, supplying, testing and commissioning of wall/floor mounted (as per site requirement) LT Distribution board with 01 No. 200 Amp. 4 pole 415 Volt, 50 Hz, thermal magnetic MCCB as incoming and 02 No.100 Amp. 4 pole MCCB, 03 Nos. 40 Amp. 4 pole MCCB as outgoing. .(As per Specification attached) (Inspection: Consignee, Inspection Charges: None) | — | — | — | 4,74,426.96 | |
| — | 2.00 | — | — | ||
| Supply, erection, testing & commissioning of 12.50 Mtrs. high mast shaft totally hot dip galvanized and suitable for wind velocity as per IS 875 PART 3. The mast shaft shall be in two finished section. it shall also include accessories for 12.5 Mtrs. high mast including head frame, steel wire rope 6 mm dia. (7/19 construction ) double drum winch, galvanized lantern carriage arrangement suitable for 6 luminaries symmetrically and its control gear boxes and lighting finial with integral power tool. The work also include design and casting of suitable foundation bolts with M-15 Concrete for high mast considering the safe soil bearing capacity at site as 10T per Sq. mm at 2 Mtrs. depth. the foundation should be casted with foundation bolt manufactured with special steel along with nuts, washers, anchors plates and templates as required make: BAJAJ/PHILIPS. The mast shall have one longitudinal weld and single dipping (hot dip galvanized) per section (as per specification attached). (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,18,450.3 | |
| — | 2.00 | — | — | ||
| Supply & installation of control panel housing suitable timer contactor circuit for Automatic switch ON & switch OFF of the mast at a preset time. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 36,161.96 | |
| — | 4.00 | — | — | ||
| Supply and fixing of aviation light luminaires of BGAV 302 LED of Bajaj or similar comprising of aluminium housing with polycarbonate enclosure (1 fitting per mast is necessary if no taller structures are in the vicinity). Fitting should be of reputed make and as per tech. spec. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 17,094.28 | |
| — | 8.00 | — | — | ||
| Supply, install, test & commission of Ray roll plug socket 20amp SPN Ray Roll Plug socket including connection /wiring of "C" series 32 amps SP-MCB as per specification. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 7,183.44 | |
| — | 2.00 | — | — | ||
| Battery Charging rectifier set complete with all accessories having, earthing connection and masonry works e.t.c. as required. at site. The Rectifier set shall have 2 set of Knife Switches as outgoing as per specifications attached Input- 3 phase 415 Volts A.C. Output -110 volt to 150 volt 200 Amp. D.C. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 4,58,799.68 | |
| — | 24.00 | — | — | ||
| Supply of material, fabrication, installation and commissioning of Rolling in Examination lighting MS box of suitable dimensions as per specifications attached at specified locations. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,45,687.2 | |
| — | 40.00 | — | — | ||
| Fabrication, supply, fixing and commissioning of Battery charging board /box emergency terminal box two ways outdoor type as per RDSO Drg. No. SKE-3929 as per specifications attached. (Inspection: Consignee, Inspection Charges: None | — | — | — | 34,934.8 | |
| — | 22.00 | — | — | ||
| Supply, erection, testing and commissioning of pre-cooling points having BCH 500 volt 63 A plug switch unit combined set (male-female both) including aluminium four pole bus bar chamber of 250 Amps capacity complete inside MS enclosure having suitable design for incoming and outgoing 3 ½ core 120 sq. mm XLPE cable with earthing of the pre-cooling point as per the detailed technical specification and site requirement this item includes the supply of 63 amp. MCCB 4pole. size of MS box (70 x40x30mm)as per site requirement and drawing. (Inspection: Consignee, Inspection Charges: None | — | — | — | 4,03,064.2 | |
| — | 2000.00 | — | — | ||
| Supply, erection and commissioning of auxiliary cable tray made from angle 35x35x5 mm and MS plate 35x5 mm to be fixed on already grouted MS bolts on the pillar/ platform or washing line of 260 mm vide & (as per technical specification attached.) (Inspection: RITES, Inspection Charges: To be borne by Railways) | — | — | — | 9,52,000 | |
| — | 200.00 | — | — | ||
| Supply, fixing, testing & connecting of LED backlit single sided signage boards withn IP-65 CRCA housing, vinyl print on acrylic sheet which is backlit with high grade, high brightness LED modules, inbuilt SMPS driver, without battery backup, operating voltage 80v-270V AC, life period >50000 hrs, LPM technology, including fabrication and supply of clamping arrangements as desired by site engineer. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,08,156 | |
| — | 130.00 | — | — | ||
| Supply, fixing, testing & connecting of LED backlit double sided signage boards withn IP-65 CRCA housing, vinyl print on acrylic sheet which is backlit with high grade, high brightness LED modules, inbuilt SMPS driver, without battery backup, operating voltage 80v-270V AC, life period >50000 hrs, LPM technology, including fabrication and supply of clamping arrangements as desired by site engineer. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,59,243.3 | |
| — | 4.00 | — | — | ||
| Supply of Cable junction Box for 2x185 sqmm cable with Al Bus bar for single phase with neutral suitable for termination of 150 Amps CLS panel for 25 KVA Auto transformer as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 35,658.48 | |
| — | 2.00 | — | — | ||
| Erection of Distribution Box /Junction box for 10 KVA and 25 KVA Auto transformer as per spec (Inspection: Consignee, Inspection Charges: None) | — | — | — | 533.02 | |
| — | 2.00 | — | — | ||
| Supply, fixing and commissioning of 150 Amp. Capacity 240 volts, 50 Hz. for 25 KVA AT automatic Change Over Control and Distribution panels for CLS as per Latest RDSO Specification No. TI/SPC/ PSI/CLS/ 0020 with A & C Slip 1 to4. CORE approved drawing no.: COS/CORE/2005/01 Rev.02 or latest (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,93,304.72 | |
| — | 120.00 | — | — | ||
| Design, Manufacturer, Supply, fixing at Specified given locations and testing, commissioning of LED based station Name Board in Hindi/English as per given size of letters and as per specification. (Inspection: RITES, Inspection Charges: To be borne by Railways) | — | — | — | 8,64,452.4 | |
| — | 4.00 | — | — | ||
| Supply, lowering , testing & commissioning of 3 star and above rated mono block submersible pump cap., 10 HP, head 35 m, dis. 510 LPM. As per BEE approved MONOBLOCK (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,51,156.2 | |
| — | 4.00 | — | — | ||
| Design, manufacture, Supply, fixing, testing & commissioning of Fully automatic type Star Delta Starter panel for Submersible pumps Of Model No.MUG-20 Relay Range 13-21 of L&T or Similar model of BCH,C&S (Inspection: Consignee, Inspection Charges: None) | — | — | — | 36,716.48 | |
| — | 1200.00 | — | — | ||
| Supply and drawing of PVC insulated 3 core sheathed Flat copper submersible cable 1100 volt grade conf. to IS: 694/1990 with latest amendments, size 6 sq mm. Approved make list is attached. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 3,40,116 | |
| — | 400.00 | — | — | ||
| Supplying, connecting, fixing and lowering of GI pipe 2" Dia ISI marked medium density within the tube well / UG tank including supply & fixing of suitable size accessories like flange ,safety clamp , cable clamp, pipe fittings, bends, socket etc. as required and excluding flat copper cable. This work is to be replaced with existing work and released GI pipe shall be deposit in the store of site supervisor. Approved make list is attached (Inspection: Consignee, Inspection Charges: None) | — | — | — | 2,13,316 | |
| — | 160.00 | — | — | ||
| Supply, installation, testing & commissioning of (150 mm width x 50 mm depth x 1.6 mm thickness) perforated Hot Dipped Galvanized Iron Cable Tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections fixed with MS Angle frame duly painted of 35 mm x 5 mm thick and all hardware complete in all respect. (Inspection: Consignee, Inspection Charges: None) | — | — | — | 1,11,998.4 | |
| — | 120.00 | — | — | ||
| Supply, installation, testing & commissioning of (100 mm width x 50 mm depth x 1.6 mm thickness) perforated Hot Dipped Galvanized Iron Cable Tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections fixed with MS Angle frame duly painted of 35 mm x 5 mm thick and all hardware complete in all respect (Inspection: Consignee, Inspection Charges: None) | — | — | — | 77,880 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACS1TO11COMPRESSED1_1.pdf ACS01t11of GCC2022
ATTACHMENT
SORTECHNICALSPECGSU13of202627
ATTACHMENT
TDGSU-13of2026-27.pdf
ATTACHMENT
ACS1TO11COMPRESSED1_1.pdf
ATTACHMENT
SORTECHSPECGSUSBLT-OCHTHM-JGSU13of2026-27.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .