| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹37.7 L+₹2.8 L (7.99%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹38.4 L+₹3.5 L (10.1%)Rejected-AOC | L3 | Rejected-AOC Not lowest | |
| 4 | L4₹39.0 L+₹4.1 L (11.8%)Rejected-AOC 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-AOC Not lowest | |
| 5 | L5₹39.4 L+₹4.5 L (13.0%)Rejected-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L5 | Rejected-AOC Not lowest |
Tender Value
Refer Docs
Closing Date
8 May 2021, 6:00 pmClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR AND MAINT OF DG SET AND AMF PANEL AT AF STN JODHPUR
2021_MES_435843_1
8450/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
Exempted
19 May 2021
12 Apr 2021
10 May 2021
12 Apr 2021
8 May 2021
26 Apr 2021
Amount
Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity 5KVA & up to 100 KVA at 250 running hours , dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform,removal of sludge from platform & also from inside of canopy of DG set including minor material like ; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection , testing on full load complete to the entire satisfaction of the Engineer in Charge. Note : - (a) If any part will be replaced it will be measured and paid as supply only in respective items given here in after. (b) The rate quoted for this item also includes quarterly maintenance of DG Sets like cleaning of DG Sets ; tightening of nut bolts, checking of control wiring connections, cleaning of platform and removal of sludge from platform & inside canopy of DG set as directed by the Engineer in charge. A register shall be maintained by the JE Concerned & to signed by the JE, AGE and contractor. (c) DG Sets are of the Makes ; Kirlosker/Birla Power/Volvo/TATA/ Mahindra/Crompton Greaves/Ashok Leyland/Cummins
Supply only diesel filter suitable for DG set of capacity upto 100 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only Engine oil filter suitable for DG sets of capacity upto 100 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only Air filter suitable for DG set of capacity upto 100 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.Crompton Greaves.
Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity beyond 100KVA & up to 250KVA at 250 running hours , dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform,removal of sludge from platform & also from inside of canopy of DG set including minor material like ; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection , testing on full load complete to the entire satisfaction of the Engineer in Charge. Note : - (a) If any part will be replaced it will be measured and paid as supply only in respective items given here in after. (b) The rate quoted for this item also includes quarterly maintenance of DG Sets like cleaning of DG Sets ; tightening of nut bolts, checking of control wiring connections, cleaning of platform and removal of sludge from platform & inside canopy of DG set as directed by the Engineer in charge. A register shall be maintained by the JE Concerned & to signed by the JE, AGE and contractor. (c) DG Sets are of the Makes ; Kirlosker/Birla Power/Volvo/TATA/ Mahindra/Crompton Greaves/Ashok Leyland/Cummins
Supply only diesel filter suitable for DG set of capacity above 100 KVA and upto 250 KVA. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only Engine oil filter suitable for DG sets of capacity above 100 KVA and upto 250 KVA. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only Air filter suitable for DG set of capacity above 100 KVA and upto 250 KVA. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only Diesal filter suitable for 250 KVA Volvoline DG set.
Supply only Engine oil filter suitable for 250 KVA Volvoline DG set.
Supply only Air filter suitable for for 250 KVA Volvoline DG set.
Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity beyond 250 KVA & up to 400 KVA at 250 running hours , dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform,removal of sludge from platform & also from inside of canopy of DG set including minor material like ; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection , testing on full load complete to the entire satisfaction of the Engineer in Charge. Note : - (a) If any part will be replaced it will be measured and paid as supply only in respective items given here in after. (b) The rate quoted for this item also includes quarterly maintenance of DG Sets like cleaning of DG Sets ; tightening of nut bolts, checking of control wiring connections, cleaning of platform and removal of sludge from platform & inside canopy of DG set as directed by the Engineer in charge. A register shall be maintained by the JE Concerned & to signed by the JE, AGE and contractor. (c) DG Sets are of the Makes ; Kirlosker/Birla Power/Volvo/TATA/ Mahindra/Crompton Greaves/Ashok Leyland/Cummins
Supply only diesel filter suitable for DG set of capacity above 250 KVA and upto 400 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only Engine oil filter suitable for DG sets of capacity above 250 KVA and upto 400 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only Air filter suitable for DG set of capacity above 250 KVA and upto 400 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves..
Supply and filling Premixed coolant complete all as specified and directed by the Engineer-in-Charge. Make :- Volvoline, Koel, Fleetguard, Castrol, Bosch & Servo.
Supply and fixing in replacement engine oil, multi grade 15w40 in engine complete all as specified and directed by the Engineer-in-Charge.Make :- Indian oil/ Hindustan Petrolium/ Castrol / Pride /Servo
Material and Labour for replacement turbo of DG set having capacity upto 160 KVA of oringinal make as per existing in DG Set at site complete all as specified and directed by the Engineer-in-Charge.
Material and Labour for dismantling the radiator and fan from the engine of DG set of capacity upto 400 KVA for cleaning of copper tubes and cooling fins by using descaling solution and soldering, patch work; including water pumps assembly for replacement of defective water pumping assembly of oringinal make as per existing in DG Set, and transporting to repair workshop, bringing back & including reinstallation at site complete all as specified and directed by the Engineer-in-Charge.
Material & labour for Repair/replacement of water temperature sensor unit Complete all as specified and directed by the Engineer-in-Charge. Make :- Kirloskar, Cummins,CG & Ashok Leyland.
Supply and fixing in repairs all type of hose pipe, over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittings of original make existing in the DG set Complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs BATTERY 12 Volt 180 AH capacity Complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs BATTERY 12 Volt 150 AH capacity Complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs BATTERY 12 Volt 100 AH capacity Complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs BATTERY 12 Volt 42 AH capacity for 5 KVA UPS with all connecting cable and accessories complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs MCCB 400 Amp 4 pole 415 V with incoming and outgoing spreaders complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs MCCB 250 Amp 4 pole 415 V with incoming and outgoing spreaders complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs MCCB 200 Amp 4 pole 415 V with incoming and outgoing spreaders complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs MCCB 160 Amp 4 pole 415 V with incoming and outgoing spreaders complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs MCCB 125 Amp 4 pole 415 V with incoming and outgoing spreaders complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs MCCB 100 Amp 4 pole 415 V with incoming and outgoing spreaders complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Four Pole Contactor ,240 Volt AC, 2 NO+NC, or 01 NO NC of capacity 100 Amps Complete all as specified and directed by the Engineer-in-Charge .
Supply & Fixing in repairs Four Pole Contactor , 240 Volt AC, 2 NO+NC, or 01 NO NC of capacity 200 Amps Complete all as specified and directed by the Engineer-in-Charge .
Supply & Fixing in repairs Four Pole Contactor ,240 Volt AC, 2 NO+NC, or 01 NO NC of capacity 160 Amps Complete all as specified and directed by the Engineer-in-Charge .
Supply & Fixing in repairs Four Pole Contactor ,240 Volt AC, 2 NO+NC, or 01 NO NC of capacity 250 Amps Complete all as specified and directed by the Engineer-in-Charge .
Supply & Fixing in repairs Four Pole Contactor ,240 Volt AC, 2 NO+NC, or 01 NO NC of capacity 300 Amps Complete all as specified and directed by the Engineer-in-Charge .
Supply & Fixing in repairs Four Pole Contactor coil 240 Volt AC of capacity 100Amps Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Four Pole Contactor coil 240 Volt AC of capacity 160Amps Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Four Pole Contactor coil 240 Volt AC of capacity 200Amps Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Four Pole Contactor coil 240 Volt AC of capacity 250Amps Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Four Pole Contactor coil 240 Volt AC of capacity 400Amps Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Four Pole Contactor coil 240 Volt AC of capacity 600Amps Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Autocut Electrical Battery Charger Unit 12V DC, 10 Amp SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Type Rectifier Unit etc. Complete all as specified and directed by the Engineer-in-Charge. Make:- NHP, MNM, Teknica, AE, Max Power or other makes given in Appx 'B'.
Supply & Fixing in repairs Autocut Electrical Battery Charger Unit 24V DC, 10 Amp SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Type Rectifier Unit etc. Complete all as specified and directed by the Engineer-in-Charge. Make:- NHP, MNM, Teknica, AE, Max Power or other makes given in Appx 'B'.
Supply & Fixing in repairs Voltage Monitor Relay, 3 Phase AC, 110/415V, AC Setting 75-100/300-400V, Trip Time 0-10 Sec Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs indicating lamp set RYB for phase indication operating 240 volt 50 HZ AC with new one LED panel mounting type complete to match existing one Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Timer AC/DC on Delay, AC 110/220V AC DC 24, 1-10, 3-30, 10-100 Sec Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Engine Start Relay, 12 V DC, For Gensets 3 Cranks No & Off 0-30 Sec Each Setable. Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repair of Engine Start Relay, 24 V DC, For Gensets 3 Cranks No & Off 0-30 Sec Each Setable Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Earth Fault Relay, Non Direction, Definite Time & Current adustable Setting 0.4-4A/0.2-2A, Time 0-10 Sec Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Copper Conductor Control Cable of 12core, sectional area 1.5 Sqmm (each core) Multistranded for DG Set to AMF Panel Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Single Phase Preventer in AMF Panel Complete all as specified and directed by the Engineer-in-Charge. Make :- Teknika, L&T, Vinilec
Supply & Fixing in repair of DC 12V Self Solenoid Coil suitable for DG Set of any capacity of make as orginal existing in DG set Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs DC 24V Online Solenoid suitable for DG Set of make as orginal existing in DG set Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Microprocessor/Alfa-Numeric Based DG Set PLC for DG set (PS 500 unit for CUMMINS) Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Microprocessor/Alfa-Numeric Based DG Set PLC for DG set Kirloskar 380KVA Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Microprocessor/Alfa-Numeric Based DG Set speed control unit for DG set complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Microprocessor/Alfa-Numeric Based DG Set PLC for DG set up to 125KVA kirloskar engine set Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Microprocessor/Alfa-Numeric Based AMF Controler suitable for AMF Panel of DG Set. (PLC FOR Mahindera DG SETS) Complete all as specified and directed by the Engineer-in-Charge.
Material and labour for repair/overhauling of self starter upto 125 KVA 12 Volts of make : Lucas, including replacement of carbon brusses, bearing, bushes, rewinding of armature and field etc. and warnishing Complete all as specified and directed by the Engineer-in-Charge .
Supply and fixing in repairs Oil Pressure switch 2Pin or 3Pin of original make existing in self starter complete all as specified and directed by the Engineer-in-Charge .
Supply and fixing in repairs Battery terminal made of Brass of original make existing in self starter complete all as specified and directed by the Engineer-in-Charge .
Supply and fixing in repairs Battery Led of self starter of original make existing complete all as specified and directed by the Engineer-in-Charge .
Supply and fixing in repairs Fan Belt of self starter of original make existing complete all as specified and directed by the Engineer-in-Charge .
Material and labour for opening of AMF Panel, Cleaning of dust using blower & cleaning agents, Checking for faults, Removal of Faults, Re-wiring of old unserviceable wiring, Testing of Control Wiring complete as required and closing of AMF Panel after replacement of unserviceable parts and testing on completion of job on existing load including cleaning and removing the sludge from DG set Complete all as specified and directed.
Supply & fixing in repairs AMF Controller (PROCOM UNIT) for AMF Panel for 12V and 24 V both supply Complete all as specified and directed.
Supply & fixing in repairs Auxiliary Relay 14/11/8 Pin 230V AC relays, suitable for AMF Panel of DG Set Complete all as specified and directed.
Supply & fixing in repairs Auxiliary Relay 14/11/8 Pin 12/24 volts relays, suitable for AMF Panel of DG Set Complete all as specified and directed.
Supply & Fixing in repairs DC 12V Solenoid Coil left/right suitable for DG Set of orginal make as existing at site Complete all as specified and directed.
Supply & Fixing in repairs DC 24V Solenoid Coil left/right suitable for DG Set of orginal make as existing at site Complete all as specified and directed.
Supply & Fixing in repairs relay card suitable for AMF panel make Procom 12/24V orginal make as existing at site Complete all as specified and directed.
Supply & top up of battery distiled water used for led acid battery Complete all as specified and directed.
Supply & fixing in repairs DYNAMO 12 volts suitable for DG sets of capacity up to 125 KVA Complete all as specified and directed. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply & fixing in repairs DYNAMO 24 volts suitable for DG sets of capacity up to 400 KVA Complete all as specified and directed. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply & Fixing in replacement of liner of suitable size of original make existing in the DG capacity 25 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of Piston of suitable size of original make existing in the DG capacity 25 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of Tepid Valve of suitable size of original make existing in the DG capacity 25 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of Piston Ring of suitable size of original make existing in the DG capacity 25 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of Engine Gasket of suitable size of original make existing in the DG capacity 25 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of fuel injector pump of suitable size of original make existing in the DG capacity 25 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of O ring set of suitable size of original make existing in the DG capacity 25 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of Nosal of suitable size of original make existing in the DG capacity 25 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of CR bearing of suitable size of original make existing in the DG capacity 25 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of Engine head of suitable size of original make existing in the DG capacity 25 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in repairs water body for DG Set upto 160 KVA of orginal make as existing at site complete all as specified and directed by the Engineer-in-Charge.
Disconnecting , dismantling & taking down old unserviceable AMF panel and Supply, installation, testing and commissioning of AMF Panel outdoor type, 82.50 KVA with alluminium busbar of capacity 400 A, TPN powder coated (coloured) heat shrinkable sleeves, 3.15 mm CRCA sheet steel enclosure duly powder coated with inbuilt on load change over switch of 250 Amps, and consisting the following:-
Item No 87.00 Contd... INCOMING from 82.50 KVA (i) MCCB 200 Amps four pole 25 KA -01 No (ii) Spreaders 250 Amps four pole -01 Set (iii) Extended Rotary handle 250 Amps four pole -01 No (iv) Earth fault module 250 Amps four pole -01 No (v) Power Contractor 250 Amps four pole AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (vi) C.T. 100/5A CL-1.0 10 VA - 03 Nos (vii) Digital MF meter 96 x 96 mm with 485 Port CL1.0 - 01 No (viii) Indicating lights (Red-2, Yellow-2. Green-2) (ix) VMR - 01 No (x) Inbuilt on load change over switch of 250 Amps for bypassing of AMF panel - 01 No OUTGOING (i) MCCB 200 Amps four pole 25 KA -01 No (ii) Power Contractor 250 Amps four pole AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iii) SMPS 12V, DC, 10A -01 No (iv) Emergency stop P.B. -01 No (v) Digital Amp meter 24 V, DC - 01 No (vi) Digital Volt meter 24 V, DC - 01 No (vii) Hooter - 01 No (viii) Procom Unit (DGC6D) for control - 01 No
Disconnecting , dismantling & taking down old unserviceable AMF panel and Supply, installation, testing and commissioning of AMF Panel outdoor type, 125 KVA with alluminium busbar of capacity 450 A, TPN powder coated (coloured) heat shrinkable sleeves, 3.15 mm CRCA sheet steel enclosure duly powder coated with inbuilt on load change over switch of 315 Amps, and consisting the following:-
Item No 88.00 Contd... INCOMING from 125 KVA (i) MCCB 250 Amps four pole 25 KA -01 No (ii) Spreaders 250 Amps four pole -01 Set (iii) Extended Rotary handle 250 Amps four pole -01 No (iv) Earth fault module 250 Amps four pole -01 No (v) Power Contractor 300 Amps four pole AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (vi) C.T. 250/5A CL-1.0 10 VA - 03 Nos (vii) Digital MF meter 96 x 96 mm with 485 Port CL1.0 - 01 No (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) VMR - 01 No (x) Control MCB 6A SP 10KA C curve - 03 Nos (xi) Inbuilt on load change over switch of 250 Amps for bypassing of AMF panel - 01 No OUTGOING (i) MCCB 250 Amps four pole 25 KA -01 No (ii) Power Contractor 300 Amps four pole AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iii) AMF relay -06 Nos (iv) SMPS 12V, DC, 10A -01 No (v) Emergency stop P.B. -01 No (vi) Digital Amp meter 24 V, DC - 01 No (vii) Digital Volt meter 24 V, DC - 01 No (viii) Control MCB 6A SP 10KA C curve - 03 Nos (ix) Hooter - 01 No (x) Procom Unit (DGC6D) for control - 01 No
Material and labour for repair/overhauling of self starter above 125 KVA and upto 160 KVA, 24 Volts of make : Lucas, including replacement of carbon brusses, bearing, bushes, rewinding of armature and field etc. and warnishing Complete all as specified and directed by the Engineer-in-Charge .
Material and labour for repair/overhauling of self starter above 160 KVA and upto 400 KVA, 24 Volts of make : Lucas, including replacement of carbon brusses, bearing, bushes, rewinding of armature and field etc. and warnishing Complete all as specified and directed by the Engineer-in-Charge .
Supply and fixing in repairs control MCB 6 Amp single pole C curve type Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repair of DC 12/24V offline fuel Solenoid Coil suitable for DG Set of any capacity of make as orginal existing in DG set Complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs electronic governor with connecting accessories for DG set of make Mahindra, Ashok Leyland, having capacity upto 125 KVA Complete all as specified and directed by the Engineer-in-Charge.
Material and Labour for dismantling existing 100 KVA GD set properly disconnecting all electrical connections, panels and DG set, shifting to other location taking suitable safety measures while handling and shifting of DG set from current location to proposed location (withing 02 km) including transportaion, required foundation for panels and DG set, reconnection, testing and commisioning complete all as specified and directed by the Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 185 Sqmm 3.5 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor laid in trench/duct complete all as specified by Engineer-in-Charge.
Material & labour for Boring of holes for 40 mm di pipe under road, pavement, hard standing not less than 1200 mm deep, by trenchless technology using ultra sound technique and necessary machine including GI pipe of 40 mm dia, light grade complete all as specified and directed.
Material & labour for excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for cable trench/laying of pipe line/taking out pipe etc and getting out in any type of soil complete all as specified and directed by Engineer-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
Supply and filling dry clean sand in trenches for cushioning of underground cable including punning down complete all as specified and directed. Note:- Only Punned down thickness shall be maesured and paid
Supply and laying 40 to 50 mm thick rough dressed Jodhpur type stone slab cover 25 to 30 cm wide and 80 cm in length received from excavation, laid dry abutting each other with gap between adjacent slab not exceeding 10 mm for under ground protection complete all as specified and directed.
Material & labour for replacement of DG set self of 12 Volts capacity suitable for DG set of 125 KVA of make Lucas, Bosch complete all as specified and directed.
Material & labour for replacement of DG set self of 24 Volts capacity suitable for DG set of 250 KVA of make Lucas, Bosch complete all as specified and directed.
Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 150 Sqmm 3.5 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor laid in trench/duct for DG set to AMF panel complete all as specified by Engineer-in-Charge.
Material & labour in repairs for earthing complete with Copper electrode 60 cm x 60cm x 3.15mm buried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including copper strip of size 20x3mm by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dully all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in Any type of Soil, PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 25 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Material & labour for repair and maintenance of AMF panel including painting of panel dual coat of enamel paint, insulation of bus bars, welding of AMF panel to its angle iron frame, replacement of hinges, locking arrangement and all other small works complete all as specified and directed.
Material & labour for daily inspection and checking the serviceability of DG set including checking of engine oil, fuel, coolent, battery terminal on priority basis complete all as specified and directed.
Supply & fixing in replacement of tension pulley of 82.5 KVA Mahindra DG Set make as existing on site complete all as specified and directed by the Engineer-in-Charge.
Shri Electrical Enterprises
LOKESH ELECTRICAL WORKS CONTRACTOR
new india engineers
Nvimal Engineers and Contractor
M/S SUMAN ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .