Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹80.8 L
EMD Value
₹1.6 L
Closing Date
24 Mar 2025, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER SIG
16 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. (As per Rly. Bd. letter No. 2022/CE-I/CT/GCC-2022/Policy dated 14.07.2022).
As per tender document attached and GCC-2022.
15 conditions · 10 needing a document upload
As per tender document attached and GCC-2022.
As per tender document attached and GCC-2022.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Supply, Installation and Commissioning of Lightning and Surge Protection Systems for E.I Installations at Matari & Singrauli Stations in the DHN DIV.
SG-664-29-sig-2024-25
SG-664-29-sig-2024-25
Open
Works - General
6 Months
Dhanbad, Jharkhand
₹0
₹1.6 L
24 Mar 2025
3 Mar 2025
63 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 80,83,857 | ||
| — | 20.00 | — | — | ||
| Air Termination Network. (i) Supply of single spike air terminals of 17.2 mm dia. & 2000 mm length as required and as per site conditions. The air terminal shall be manufactured with Copper Bonded Steel & shall be as per IEC 62561-2. The air terminal shall be fixed with conceret base arrangement. Inspection- RITES | — | — | — | 1,20,000 | |
| — | 6.00 | — | — | ||
| Air Termination Network. (ii) Supply of single spike air terminals of 10 mm dia. & 1200 mm length as required and as per site conditions. The air terminal shall be manufactured with Copper Bonded Steel & shall be as per IEC 62561-2. The air terminal shall be fixed with Z clamp arrangement. Inspection- RITES | — | — | — | 10,530 | |
| — | 782.00 | — | — | ||
| Air Termination Network. (iii) Roof Conductor : Supply of 8 mm dia Copper Bonede Steel round conductor (250 Micron) for air termination network at terrace level and Roof and shall meet the requirement of IEC 62561-2.Inspection- RITES | — | — | — | 3,12,800 | |
| — | 693.00 | — | — | ||
| Air Termination Network. (iv) Supply of Roof Conductor holder for holding of 8 mm dia. round conductor (for RCC roof). The conductor holder shall be of Stainless steel which is mounted on plastic base support and shall meet the requirements of IEC 62561-4.It should be installed at every 1 mtr. Inspection- RITES | — | — | — | 2,25,225 | |
| — | 129.00 | — | — | ||
| Air Termination Network. (v) Supply of parapet conductor holder(with Glue) for holding 8 mm dia. round conductor (for metallic sheet). The conductor holder should be installed at every 1 mtr . The conductor holder shall be made with Z type metal shed holder & as per IEC 62561-4. Inspection- RITES | — | — | — | 51,600 | |
| — | 15.00 | — | — | ||
| Air Termination Network. (vi) Bridging cable: Supply of 16sq.mm. copper cable along with lugs, having 500mm length & as per IEC 62561-1 so as to connect air termination rod with any metallic structure on the roof. Inspection- RITES | — | — | — | 4,800 | |
| — | 115.00 | — | — | ||
| Air Termination Network. (vii) Supply of Universal Connector for making straight, Tee & Cross joint of 8 mm Aluminium Conductor to 8 mm dia Aluminium conductor on parapet wall, roof and vertical facade of masonery / glass / metallic work.Inspection- RITES | — | — | — | 33,810 | |
| — | 320.00 | — | — | ||
| Down Conductor. (i) Supply of 8 mm dia Copper Bonded Steel round conductor ( 250 Micron) for Down conductors to be installed on vertical wall, facade of masonary / glass / metalic work. It shall meet the requirements of IEC 62561-2. Inspection- RITES | — | — | — | 1,28,000 | |
| — | 320.00 | — | — | ||
| Down Conductor. (ii) Supply of Down Conductor holder for holding of 8 mm dia. round conductor (for RCC wall). The conductor holder shall be of Stainless steel which ismounted on plastic base support and shall meet the requirements of IEC 62561-4.It should be installed at every 1 mtr. Inspection- RITES" | — | — | — | 1,04,000 | |
| — | 30.00 | — | — | ||
| Down Conductor. (iii) Supply of Test Clamp to disconnect the down conductor from the earth termination network for regular checks of the earth termination resistance value which shall be of Stainless steel and suitable for connecting 8 mm aluminium round conductor to 25x2mm Copper conductor (with enclosure). It shall meet the requirements of IEC 62561-2. Inspection- RITES | — | — | — | 37,500 | |
| — | 34.00 | — | — | ||
| Down Conductor. (iv) Supply of Expansion piece made of 8mm dia. Copper Bonded Steel & as per IEC 62561-2 along with 2MV clamps used as connecting accessory from both the ends. It shall be installed at every 20 mtr to maintain the flexibility to the conductor due to heat. Inspection- RITES | — | — | — | 30,192 | |
| — | 8.00 | — | — | ||
| Down Conductor. (v) Supply of Digital Lightning Strike counter Model: JMV/DLSC-3D or better for counting the number of lightning strikes and has a 3 Digit display facility and also records date and time . The Counter should be mounted on the Down Conductor. The Lightning Counter should be IP 67 rated enclosure suitable for external application.It shall meet the requirements of IEC 62561-6. Inspection- RITES | — | — | — | 1,60,000 | |
| — | 38.00 | — | — | ||
| Earth Termination Network. (i) Supply of maintenance free earthing as per RDSO/SPN/197 Version 1.0 or latest. Inspection- RITES | — | — | — | 4,18,000 | |
| — | 937.00 | — | — | ||
| Earth Termination Network. (ii) Supply of 25x2mm Copper Strip laid at below the ground, as Required and as per specification and code of practice. Inspection- RITES " | — | — | — | 10,49,440 | |
| — | 38.00 | — | — | ||
| Earth Termination Network. (iii)Supply of UL Listed Welding Material for 2DT Exothermic joint Between 25 x 2mm Horizontally laid Copper Strip to 25 x 2mm Horizontally laid Copper Strip. Inspection- RITES | — | — | — | 66,120 | |
| — | 32.00 | — | — | ||
| Earth Termination Network. (iv) Supply of UL Listed Welding Material for Straight Exothermic joint Between 25 x 2mm Horizontally laid Copper Strip to 25 x 2mm Horizontally laid Copper Strip. Inspection- RITES | — | — | — | 73,440 | |
| — | 76.00 | — | — | ||
| Earth Termination Network. (v) Supply of UL Listed Welding Material for Exothermic T joint Between 25 x 2mm Horizontally laid Copper Strip to 200 x 25 x 6mm Copper Bus Bar. Inspection- RITES | — | — | — | 87,400 | |
| — | 1.00 | — | — | ||
| Installation and commissioning of External Lightning Protection (ELP), Class A as per IS/IEC62305 and NBC 2016 of supplied items in schedule No.1(S.No. 1 to 17). at main building Battery, IPS Room Matari and SGRL Station. For installation & commissioning , required necessary materials to be supplied by the contractor. | — | — | — | 9,00,000 | |
| — | 8.00 | — | — | ||
| Surge Protection Device for LPS. (i) Supply Installation, commissioning of Class B/Type I Single Phase Surge Protection Devices as per IEC 62305-4 and tested according to IEC 61643 - 11, DIN Rail mountable with Maximum Continuous Operating Voltage of 320 V and Voltage Protection Level of 2.5 kV. Response Time should be less than 100 ns. The maximum impulse test current should be 50 kA (10/350 s) per pole and 100 kA (10/350 s) neutral to protective earth. The surge protection devices shall be enclosed in polycarbonate enclosure of IP 65 rating. Inspection- RITES | — | — | — | 1,20,000 | |
| — | 11.00 | — | — | ||
| Surge Protection Device for LPS. (ii) Supply Installation, commissioning of Class C/Type II Single Phase Surge Protection Devices as per IEC 62305-4 and tested according to IEC 61643 - 11, DIN Rail mountable with Maximum Continuous Operating Voltage of 320 V and Voltage Protection Level of 1.5 kV. Response Time should be less than 25 ns. The maximum impulse discharge surge current should be 20 kA (8/20 s) per pole and 40 kA (8/20 s) neutral to protective earth. The surge protection devices shall be enclosed in polycarbonate enclosure of IP 65 rating. Inspection- RITES | — | — | — | 1,21,000 | |
| — | 113.00 | — | — | ||
| Surge Protection Device. (i) Supply Installation, commissioning of Class C SPD 110 V AC, pluggable, with mechanical indication and potential free contacts, The supplied SPDs Shall have certification (CERTIFICATE ATTACHED) of IEC Standard-- National/ International Labs like CE/KEMA/EAC/UL/NABL or any other accredited test lab Inspection. Inspection- RITES | — | — | — | 5,65,000 | |
| — | 63.00 | — | — | ||
| Surge Protection Device. (ii) Supply Installation, commissioning of Class C SPD 110 V DC, pluggable, with mechanical indication and potential free contacts, The supplied SPDs Shall have certification (CERTIFICATE ATTACHED) of IEC Standard-- National/ International Labs like CE/KEMA/EAC/UL/NABL or any other accredited test lab Inspection . Inspection- RITES | — | — | — | 3,15,000 | |
| — | 4.00 | — | — | ||
| Surge Protection Device. (iii) Supply Installation, commissioning of Class B&C Combined Coordinated Single Phase SPD, pluggable, with mechanical indication and potential free contacts, The supplied SPDs Shall have certification (CERTIFICATE ATTACHED) of IEC Standard-- National/ International Labs like CE/KEMA/EAC/UL/NABL or any other accredited test lab Inspection . Inspection- RITES" | — | — | — | 88,000 | |
| — | 35.00 | — | — | ||
| Surge Protection Device. (iv) Supply Installation, commissioning of Class C SPD 400V AC, pluggable, with mechanical indication and potential free contacts, The supplied SPDs Shall have certification (CERTIFICATE ATTACHED) of IEC Standard-- National/ International Labs like CE/KEMA/EAC/UL/NABL or any other accredited test lab Inspection .Inspection- RITES | — | — | — | 2,10,000 | |
| — | 132.00 | — | — | ||
| Surge Protection Device. (v) Supply Installation, commissioning of Class C SPD 12V DC, pluggable, with mechanical indication and potential free contacts, The supplied SPDs Shall have certification (CERTIFICATE ATTACHED) of IEC Standard-- National/ International Labs like CE/KEMA/EAC/UL/NABL or any other accredited test lab Inspection . Inspection- RITES | — | — | — | 6,60,000 | |
| — | 111.00 | — | — | ||
| Surge Protection Device. (vi) Supply Installation, commissioning of Class C SPD 24V DC, pluggable, with mechanical indication and potential free contacts, The supplied SPDs Shall have certification (CERTIFICATE ATTACHED) of IEC Standard-- National/ International Labs like CE/KEMA/EAC/UL/NABL or any other accredited test lab Inspection . Inspection- RITES | — | — | — | 6,66,000 | |
| — | 190.00 | — | — | ||
| Surge Protection Device. (vii) Supply Installation, commissioning of Class D SPD 12V dataline SPD , pluggable, with mechanical indication and potential free contacts, The supplied SPDs Shall have certification (CERTIFICATE ATTACHED) of IEC Standard-- National/ International Labs like CE/KEMA/EAC/UL/NABL or any other accredited test lab Inspection . Inspection- RITES | — | — | — | 9,50,000 | |
| — | 2.00 | — | — | ||
| Allied Products & Accessories. (i) Supply of Surge Protective Device (SPD) Life Tester, designed for on-site testing of Surge Protection devices. It allows checking and indicating the health status of GDT/MOV Based SPD of voltage range up to 1000V. It shall indicate the status of SPD by measuring its electrical parameters.Inspection- RITES | — | — | — | 1,70,000 | |
| — | 2.00 | — | — | ||
| Allied Products & Accessories. (ii) Supply & Installation of Remote monitoring of SPD through a Centralized Monitoring System with following features: 1. Easy remote monitoring of the health of SPD's in a block section at single location.Inspection- RITES | — | — | — | 1,50,000 | |
| — | 2.00 | — | — | ||
| Allied Products & Accessories. (iii) Supply & Installation of Isolating spark Gap for lightning equi-potential bonding of different earth grids according to IEC 62561 part-3 at 100kA impulse current, IP 68, fire retardant enclosure.Inspection- RITES | — | — | — | 56,000 | |
| — | 2.00 | — | — | ||
| Allied Products & Accessories. (iv) Supply of Smart Earth Monitoring System which can offer real time monitoring of resistance remotely. The system shall allow continuous and immediate surveillance of resistance levels, providing valuable alert insights and information data from various locations, in real time without the need for physical presence.Inspection- RITES | — | — | — | 2,00,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .