Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹47.5 L+₹3.5 L (8.04%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹48.9 L+₹4.9 L (11.2%)Rejected-Finance JYOTISH ROAD TEZPUR DISTT SONITPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | L3 | Rejected-Finance NOT L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
2 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) TEZPUR
GE (AF) TEZPUR POST-SALONIBARI DIST- SONITPUR ASSAM-784104
REPAIR/MAINTENANCE WORKS IN WSA AREA AT AF STN TEZPUR UNDER GE (AF) TEZPUR
2023_MES_597171_2
GE/AF/TEZ/8875/E8
Open Tender
Civil Works - Others
Item Rate
180 days
TEZPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) TEZPUR
₹96,000
20 Feb 2024
14 Sept 2023
4 Oct 2023
14 Sept 2023
2 Oct 2023
19 Sept 2023
Amount
Demolition of cement concrete (un reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level),complete all as directed.
Dismantling asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings,complete all as directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc.laid,bedded and pointed in any mortar,complete all as directed.
Materials and Labour for,sand filling under floors or in foundations including watering and consolidation,complete all as specified and directed.
Materials and Labour for plain cement concrete (1:3:6) Type C-2 using 40 mm graded aggregate,in foundations,filling and mass concrete including demolition of existing cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for,complete all as specified and directed.
Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in filling gaps between roofing sheets and walls (Gap size 60 mm wide and 40mm-60 mm deeep),rounded or chamfered on edges,complete all as specified and directed.
Supply only liquid water proofing compound all as specified
Materials and Labour for brick work with Sub Class ‘B’ bricks straight or curved on plan exceeding 6M mean radius built in cement mortar (1:4) including demolition of existing brickwork or stone/ boulder masonry, built in cement mortar or lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles,complete all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frame) not exc. 1.5 Sq. M each, complete all as directed.
Supply and Fix, solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, fixed in opening all as specified and directed.
Supply and Fix, factory made solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail: Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, fixed to door frame complete all as specified and directed.
Supply and Fix, medium wight, cold rolled mild steel butt hinges,75 mm size, complete all as specified and directed
Supply and Fix, Aluminium anodized barrel tower bolts of extruded section, 100 mm long complete all as specified and directed.
Supply and Fix,aluminium handles,cast type,anodised, 100 mm size, complete all as specified and directed.
Supply and Fix in repairs,stainless steel (Silver Satin Finish), mortice lock with striker,lock matching standard screws (04 Nos.; M3x5- 03 Nos) shape of head (02) Square; length(D)x width(E)x thickness(F) 160 mm x18 mm x 3 mm, cylinder operation,key lock type,size 160 mm (L) x 90 mm (W) x 80 mm (H),lockcase size 74 mm (B) x backset 50 mm (H) suitable for Home and Office Doors,complete all as specified and directed.
Servicing/Repairs to existing steel rolling shutters of size 6000 mm (W) x 6000 mm (H) (Approx),with top cover, hasp and staple, push pull or manual type/ gear operated type with bevel gear box and crank handle by greasing of guide channels, hasp and staple,roller springs,bearings etc., including replacement of unserviceable nuts,bolts & washers in roller pulley and top cover,alignment of laths etc. for smooth operation of shutter,complete all as specified and directed. Notes:- (i) Height considered from the bottom of the lintel to the finished floor cill level. Width considered inclusive of the width of the side guides. (ii) Cost of materials such as lubricants,screws, nuts, bolts & washers etc.shall be deemed to be inclusive in the quoted rate.
Materials and Labour for, black hollow steel sections for structural use, conforming to IS 4923:1997 (Reaffirmed 2009),designation CF, in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Square or Rectangular Hollow Sections) including distance pieces, cleats etc.including dismantling of wrought iron or mild steel work of any description not otherwise specifically provided for,complete all as specified and as directed.
Material and Labour for pre-painted,galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self-tapping screws,complete all as specified and directed.
Material and Labour for pre-painted, galvalume aluminium zinc coating GI based plain steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self-tapping screws,complete all as specified and directed.
Taking down existing cement plaster/screed, roughening surfaces of old concrete roof slab/chajjas by picking, sweeping clean and washing down with water to remove dust, etc.,brushing neat cement slurry with 3.0 kg of cement per sq. metre and rendering 10 mm thick, cement plaster/screed, in cement mortar (1:3) mixed with water proofing compound as per manufactures instructions (waterproofing compound measured and paid seperately) and finishing surface even and smooth without using extra cement including provision of water proofing treatment over smooth finished surfaces by application of cold applied bituminous primer as per manufacturer's instructions, providing and laying 3.00 mm thick, plain finish, APP modified bitumenous waterproofing and damp proofing membrane with polyester reinforcement (Non-Woven Polyester Mat), conforming to IS 16532 :2017 (Dimensions and weight of APP membrane polyester as per Table 2 of IS), by forced (torch on) application, with minimum 75 mm overlap on longitudinal direction and 100 mm overlap on the transverse direction, complete all as specified and directed.
Materials and Labour for,machine pressed precast concrete interlocking paver block with grey cement and pigment,any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade,complete all as specified and directed.
Materials and Labour for 50 mm thick plain cement concrete (1:2:4) Type B1 using 20 mm graded aggregates as in floor/path/ hardstanding including finishing surfaces even and smooth without using extra cement, complete all as specified and directed.
Materials and Labour for 100 mm thick plain cement concrete (1:3:6) Type C2 using 40 mm graded aggregates as in floor/path/ hardstanding, complete all as specified and directed.
Materials and Labour for, glazed ceramic coloured tiles, 450 X 300 X 7mm thick, conforming to IS 15622,Grade B III, on vertical surface of wall such as dados, skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:3) and including dismantling existing floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises,complete all as specified and directed.
Materials and Labour for,Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, conforming to IS 15622, Grade B IIa,in floors etc.,set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed or bedding layer of cement mortar (1:6) and including dismantling existing floor, hearth or wall tiling including cement mortar bedding (but not backing),removing serviceable tiles and rubbish off the premises,complete all as specified and directed.
Materials and Labour for,Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, conforming to IS 15622, Grade B IIa,in floors etc.,set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed or bedding layer of cement mortar (1:6) and including dismantling existing floor, hearth or wall tiling including cement mortar bedding (but not backing),removing serviceable tiles and rubbish off the premises,complete all as specified and directed.
Materials and Labour for,Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, conforming to IS 15622, Grade B IIa,on vertical surface of wall such as dados,skirting etc,,set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed of cement mortar (1:3) and including dismantling existing floor, hearth or wall tiling including cement mortar bedding (but not backing),removing serviceable tiles and rubbish off the premises,complete all as specified and directed.
Materials and Labour for machine cut Kota stone slab flooring 20-25 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20 mm thick screed bed or bedding layer of cement mortar (1:4),including demolition of existing stone slabs and tiles of any description or thickness, laid bedded and pointed in any mortar, complete all as specified and directed.
Materials and Labour for machine cut Kota stone slab 18-20 mm in raisers of steps, skirting, dado and pillar,laid over and including 10 mm thick screed bed of cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing,including demolition of existing stone slabs and tiles of any description or thickness,laid bedded and pointed in any mortar,complete all as specified and directed.
Materials and Labour for rendering 15 mm thick,cement plaster, in cement mortar (1:4) on fair faces of brick work or concrete surface in walls including taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc.,complete all as specified and directed.
Materials and Labour for rendering,15 mm thick,cement plaster, in cement mortar (1:4) on fair face of brick work or concrete surfaces in walls and finishing surface even and smooth without using extra cement including applying three coats of white wash,complete all as specified and directed.
Material and Labour for,3 mm thick sheet glass,ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane,including hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones,complete all as specified and directed.
Material and Labour for preparing old surfaces plastered or unplastered and applying one coat of white wash,on walls, complete all as specified and directed.
Material and Labour for washing,rubbing down and stopping of distempered and painted surfaces and applying one coat of distemper oil emulsion,on walls, complete all as specified and directed.
Material and Labour for washing,rubbing down and stopping of distempered and painted surfaces and applying one coat of plastic emulsion paint,on walls, complete all as specified and directed.
Material and Labour for washing,rubbing down and stopping of distempered and painted surfaces on walls and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm,complete all as specified and directed.
Materials and Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. Notes:- (Applicable for Serial Item No.36 & 37) (i) Painting shall be done in camouflage pattern as per existing shade(s) and pattern(s). (ii) The Contractor shall furnish guarantee for the exterior acrylic emulsion paint and shall be responsible for effectiveness of the UV Resistance, Alkali & Fungal Resistance and Dirt Resistance of the painted areas during the guarantee period.
Material and Labour for applying one coat of fire resisting paint on old painted surfaces of any description wood,steel, iron, concrete,brick, stone, etc., exceeding 10cm in width or girth including preparation of surfaces,complete all as specified and directed.
Material and Labour for applying one coat of aluminium paint on old painted steel and iron surface of any description,over 10 cm in width or girth, not otherwise described,including preparation of surfaces complete all as specified and directed.
Material and Labour for applying one coat of synthetic enamel paint (ordinary tint) on old painted wood or wood based surface of any description,over 10 cm in width or girth,not otherwise described,including preparation of surfaces complete all as specified and directed.
Material and Labour for applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide zinc chrome primer on new or previously untreated steel and iron surface of any description,over 10 cm in width or girth, not otherwise described, including preparation of surfaces complete all as specified and directed.
Material and Labour for 2000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I ,including ball valves high pressure of PTMT (Minimum weight 210 gms) with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe, 20 mm bore and fixed and including dismantling existing water tanks exc. 1000 but not exc.2000 litres capacity and removing to store, complete all as specified and directed.
Materials and Labour for,racking out of old existing sealant compound and back up rod of the existing dummy joints by special tools like cutting blades/ machines,widening of joints by 2 mm by using cutting blades of appropriate size,straight and smooth edges,joints cleaned throughly with application of compressed air,joints shall be made dry,vacuum cleaned and free of dirt,oil, vegetation and other debries. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealent. Thereafter filled with closed cell, medium density cross linked polyethylene foam back up rod of 8 mm dia for complete length of the joint,over it to be filled with polyurethane joint sealent meeting the requirements mentioned in BS-5212, BS-4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of ± 30%,complete all as specified and directed.
Materials and Labour for,racking out of old existing sealant compound and back up rod of the existing dummy joints by special tools like cutting blades/ machines,widening of joints by 2 mm by using cutting blades of appropriate size,straight and smooth edges,joints cleaned throughly with application of compressed air,joints shall be made dry,vacuum cleaned and free of dirt,oil, vegetation and other debries. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealent. Thereafter filled with closed cell, medium density cross linked polyethylene foam back up rod of 12 mm dia for complete length of the joint,over it to be filled with polyurethane joint sealent meeting the requirements mentioned in BS-5212, BS-4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of ± 30%,complete all as specified and directed.
SHRI D. C. BISWAS
Shri A. K. Goswami
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .