Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance JALALIYA BUILDING 1ST FLOOR MASJID ROAD ALUVA ERNAKULAM 683101 | ALUVA | ERNAKULAM | KERALA | 683101 | Admitted-Finance |
| 2 | Admitted-Finance 38 1067 NEAR POORNATHRAYEESA TEMPLE TRIPUNITHURA P O ERNAKULAM 682301 ERNAKULAM ERNAKULAM KERALA 682301 | ERNAKULAM | KERALA | 682301 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-Electrical Inspectorate License of Firm Not Submitted |
Tender Value
₹33.3 L
EMD Value
₹66,596
Closing Date
17 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer(E), BSNL
O/o Executive Engineer(E), Electrical Division, BSNL Central Telephone Exchange, Trivadrum-695001.
Maintenance of EA sets in various BSNL BTS sites in Trivandrum BA for a period of one year
2022_BSNL_104470_1
13/EDT/2021-2022
Open Tender
Electrical Works
Item Rate
365 days
Trivandrum BA
Please refer tender documents
2 documents required · 2 mandatory
₹590
Yes
Accounts Officer(Cash), BSNL, Trivandrum BA
₹66,596
Yes
11 Mar 2022
5 Feb 2022
21 Feb 2022
5 Feb 2022
17 Feb 2022
5 Feb 2022
90 days
Amount
PART A ( Preventive Maintenance) Providing preventive service maintenance of E/A sets of following capacities as per the BSNL standard maintenance scope & conditions attached. The work includes checking of all physical/functional parameters of EA set, control panel and associated accessories, dedusting the EA set, checking oil ,checking and topping up of coolant/battery water, attending faults of minor nature like minor fuel/oil/water leakages, starting failures, air locks, loose connections, servicing of starting motor/stop solenoid/ charging alternator and attending other minor electrical / mechanical complaints, checking insulation values of Alternators checking of radiator hoses and replacement if required, replacement of faulty safety fuses, overall cleaning of DG set including canopy etc. ( where ever suitable spare items are not available, the spares from shut down/ scrapped DG sets of BSNL can be reutilised as per technical feasibility, availability and with the permission of site in charge without any extra cost)
Note-1. Periodic preventive maintenance site visit shall be done once in three months.However, breakdown maintenance during this period shall be promptly attended as per the terms and conditions of the agreement and cost of spares not covered in the above item No.1 will be paid extra
Note-2. Items not included under the scope of the preventive maintenance are included as per Part B and C of this schedule.
Note-3. For any unforeseen major works/service /accessories for which rates are not stipulated in this agreement that may arise during the period of this contract, for such works,BSNL will make necessary arrangement as per prevailing norms
Note-4. This item is for DG sets working in Manual condition and for sets which are brought to manual working condition by executing this item. The DG sets which needs to run in manual condition will be continued in this item. Other sets to be made in to auto condition at the earliest possible by utilising the items available in items A, B &C. of this schedule. The preventive maintenance of a particular EA set commences when it is in working condition / made in to working condition and first service shall be recorded as first measurement. once executed, the interval for the next service shall be after 3 months.
up to 10 KVA (per site once in three months)
Above 10 KVA up to 15 KVA (per site once in three months)
Above 15 KVA and up to 30 KVA (per site once in three months)
Providing periodical preventive maintenance of E/A sets withAMF panel of following capacities as per the BSNL standard maintenance scope & conditions attached. The work includes checking of all physical/functional parameters of EA set, AMF control panel and associated accessories, and dedusting the EA set, checking of oil ,checking and topping up of coolant/battery water, attending faults of minor nature like minor fuel/oil/water leakages, starting failure, air locks, loose connections, servicing of starting motor/stop solenoid/charging alternator and other minor electrical / mechanical complaints, checking insulation values of Alternators checking of radiator hoses and replacement if required, replacement of faulty safety fuses, overall cleaning of DG set including canopy etc. ( where ever suitable spare items are not available, the spares from shut down/ scrapped DG sets can be utilised as per technical feasibility, availability and with the permission of site in charge without any extra cost)
Note-1. Periodic preventive maintenance site visit shall be done once in three months.However, breakdown maintenance during this period shall be promptly attended as per the terms and conditions of the agreement and cost of spares not covered in the above item will be paid extra
Note-2. Items not included under the scope of the preventive maintenance are included as per Part B and C of this schedule.
Note-3. For any unforeseen major works/service /accessories for which rates are not stipulated in this agreement that may arise during the period of this contract, for such works,BSNL will make necessary arrangement as per prevailing norms
Note-4. This item is for DG sets which are in Auto mode and sets which were made in auto mode by migrating from item No.Part A.1 or after getting repaired using items available in this agreement. The preventive maintenance of a particular EA set commences when it is in working condition / made in to working condition and first service shall be recorded as first measurement. Once executed, the interval for the next service shall be after 3 months.
up to 10 KVA (per site once in three months)
Above 10 KVA and up to 15 KVA (per site once in three months)
Above 15 KVA and up to 30 KVA (per site once in three months)
Part A (Total 210 DG sets taken at an average 4 visits/ DG with in an Year)
Part B: Consumables (Oil Servicing and Batteries )
This item to be executed only where ever required and as per the instructions of engineer in charge
Carrying out oil servicing of following capacity EA set i/c draining the existing lub oil and supplying and filling of superior quality and suitable grade for the engine lub oil ( 15 W 40 grade ), replacing of fuel filters, lub oil filters etc complete as per the maintenance schedule, terms and conditions and specifications attached.
up to 10 KVA
Above 10 KVA and up to 15 KVA
Above 15 KVA and up to 30 KVA
Note :The oil servicing of the EA sets has to be done once in a year or at 250-500 hours or as reccomended by the OEM as per direction of Engineer in charge. ( In case of oil change required before the said period like idleness of EA set or any other fault, the same may be done with the approval of Engineer in charge of the station). The date of changing of oil and hours may be recorded in Log Book.
Providing 12Volts Lead acid batteries of following capacities of automotive duty with Minimum 36 months Warrantee suitable for BSNL EA sets in fully charged condition for replacing of faulty batteries which are life expired/ damaged. (Make :BSNL approved makes). The date of installing battery and site name to be written with permanent marker on battery without erasing bar code. Also details to be entered in DG log book also, Interchanging batteries to be avoided and if any reqd to be noted in log book. The warrantee card with dated seal and site name to be submitted to Engineer In charge ( No buy back and dismantled battery shall be handed over to site in charge)
NOTE: Faulty Batteries whose life has exceeded 3 years /in damaged condition/ not in good condition due to prolonged non usage are included in the scope of this item. For batteries less than 3 years and in good condition at the time of taking over, the date of previous installation of battery shall be noted by the agency, countersigned by Engineer in charge of the station and note the same in DG Log book. The site code and date shall be noted with permanent marker on battery during taking over and during new installation. In such sites, the agency shall arrange spare service battery, free of cost till expiry of above 3 years or contract period whichever is earlier.
PART C : Supply and fixing of Spares
Note:1: This item to be executed only where ever required and as per the instructions of engineer in charge. As far as possible the DG sets to be made in to working condition utilising items in Part A & B.
Replacement of faulty Microprocessor based AMF Controller with new one suitable for the required capacity single/ three phase EA sets compatible for Water/Air cooled Engine in the existing AMF control panel including disconnecting and dismantling the faulty one, including providing and fixing all accessories , making necessary wiring arrangements, providing necessary support with hylum sheet./ metallic sheet so as to avoid water entry, including functional testing and commissioning with 1 year warranty and as per site conditions and specifications attached. (Make:SIAS /Deep sea/Bernini/C&S)
Replacement of faulty 4 Pole 415V Power contactor of following ratings, of suitable voltage i/c dismantling the item, giving connection , testing and commissioning as reqd. AC-1 Rating (Existing makes:MCX type-L& T / Schneider Electric/ Siemens/ Telemecanique or similar superior).Add block to be provided where ever reqd
50 A contactor ( up to 30 KVA EA sets)
63A contactor ( In sites where existing contactor of same rating is only feasible and to avoid replacing both EB and DG contactors )
100A contactor ( In sites were existing contactor of same rating is only feasible and to avoid replacing both EB and DG contactors )
Replacement of faulty contactor kit/ coil of suitable voltage for the existing Contactor of up to 63A i/c dismantling the item, giving connection , including testing and commissioning as reqd. (Make:M/s L& T / Schneider Electric/ Siemens/ Telemecanique/ Similar superior makes)
L&T MCX 11/ SS make - Contactor kit
L&T MCX 12 / SS make - Contactor kit
L&T MCX 11/ SS make - Contactor coil
L&T MCX 12 / SS make - Contactor coil
Rewinding of faulty starting motor with copper conductor including baking / heating varnishing for EA sets upto 30 KVA etc as reqd
Replacement of faulty Battery charger unit with new one, SMPS based ,Horizontal mounting type, input voltage 170-260 V AC,50 Hz ,Output 12 V DC @ 10 A suitable for Battery including mounting, making connections ,testing and commissioning as required.( One Year Warranty)
S/F of the following spares for the E/A set and its controls for the smooth functioning of the system i/c checking the items and replacing the faulty one. giving necessary connections testing and commissioning etc as reqd. ( For EA sets up to 30 KVA)
LVM relay
START/STOP push button
START/STOP relay
Analogue hour meter
Electronic hour meter
Fuel gauge
V belt
12V ,Stop solenoid ( one year warranty)
32 Amps ," c " series ,TP , MCB
32 Amps ," c " series ,4P , MCB
32 Amps ," c " series , DP , MCB
10 Amps ," c " series , DP , MCB
63A ,4P , 3way + off,Changeover switch
Add on block (2NO+ 2NC)
Metallic braided Diesel flexible pipe lenth up 1Mtr
Metallic Diesel braided flexible pipe lenth above 1 Mtr and up to 2Mtr
Copper battery cable (1 pair)
Copper sockets of battery cable (1 set)
LLOP sensor
HCT sensor
12 V /24 V OEN/Pla relay plug in type
Electronic AVR suitable for EA set up to 30 KVA ( one year warranty)
415V 63A ,4P,MCCB ,36KA breaking capacity .(Make L&T/SS)
415V, 63A ,4P, on load change over switch without enclosure (Make HPL/SS)
415 V 63A ,4P, on load change over switch with enclosure , (Make HPL/SS)
Blower fan bearing
Mechanical interlock for 2 Nos, 32/63A, 4 Pole contactors
S/F of Generator Protection unit suitable for DG sets up to 30 KVA (SIAS- SUN/ C&S/SS make)
Arresting exhaust leakage of the exhaust line and silencer i/c dismantling the same from flange , welding , re-fixing etc complete as required
Supplying and fixing 65mmdia 30 cm length metallic flexible hose for DG silencer i/c welding ,fixing etc complete as required .
Supplying and fixing rubber type AVM pad suitable up to 30 KVA EA set , M/s Eicher /Mahindra /Kirloskar/Lister peter make Engine Alternator by lifting /raising the engine from base , dismantling the faulty one ,fixing ,testing, commissioning etc complete as required.(Make : Polybond/s.s make )(note: Rate per piece)
Supplying and fixing rubber type EA coupling i/c dismantling the faulty one as required .( up to 30 KVA)
Rewinding the following portions of alternator after disconnecting the existing Alternator of all makes from the 3 Phase DG set , transporting the same to work shop for rewinding ,dismantling the alternator , removing the damaged copper winding wire , rewinding with class F insulated enameled round copper winding wire, fiber glass tape, wedge, sleeve, sheet etc, insulating with superior quality varnish ,soldering copper sockets, drying, backing , reassembling the same , transporting back to site ,reconnecting , testing at site including loading, unloading, transportation etc complete as required. copper scrap value to be considered.
30 KVA main stator
30 KVA Main rotor
30 KVA exciter armature
30 KVA exciter rotor
30 KVA Alternator bearing assembly
15 KVA main stator
15 KVA Main rotor
15 KVA exciter armature
15 KVA exciter rotor
15 KVA Alternator bearing assembly
Supplying and fixing 85mmdia 30 cm length metallic flexible hose for DG silencer i/c welding ,fixing etc complete as required .
Servicing of clogged radiator using pressurized pump, cleaning with chemical solution, refilling of coolant, minor repairs etc
Repairing of existing AMF controller with help of respective OEM ,to and fro transportation ,giving connection ,testing etc as required
Repairing of existing 12 Volt battery charger as required .
Repairing of fuel injector of fuel injection pump as required(Rate is for servicing of each injector )
Dismantling of existing 88/100 lead acid battery ,re-charging the battery by replacing the acid ,to and fro transportation ,re-fixing the same as required .
Supplying and Fixing 380mm sweep heavy duty fresh air fan in the existing DG set canopy up to 30 KVA i/c providing necessary clamping arrangement ,nuts ,bolts ,giving connection etc complete as required .(Make : Almonard /s.s make )
Rewinding of 250/380mm sweep heavy duty fresh air fan /exhaust fan in the existing up to 30 KVA DG set canopy i/c to and fro transportation ,fixing etc as required .
Supplying and laying 4x16 Sq: mm aluminum conductor armoured cable in surface /pipe /loose in panel as required for replacing faulty cable between Meter bord, DG etc
Supplying and laying 4x10 Sq: mm aluminum conductor armoured cable in surface /pipe /loose in panel as required .
Supplying and filling 15 W 40 engine oil suitable for various capacity engine as required. ( for using in sites where only top up is reqd during initial visit)
Providing hinges for the canopy door/ rapairing the same so as to close the door of canopy, painting the repaired portion with anticorrosive paint etc as reqd ( Per hinges)
Attending to roof leak of DG canopy by fixing tar sheet on roof, after cleaning the surface and applying one coat of anti corrocive paint etc as reqd.
Replacing 1 No 63A Porcelain fuse unit from exisiting meter board, giving connection etc as reqd ( For EB connection burned sites)
Minor patch work of KSEB meter board,arresting holes to prevent water and rodent entry,tightening the connections of cable and wires, applying one coat of anticorrosive paint and sign writing as reqd. ( for one time maintennace of meter board)
Providing and Fixing of 63A 4 Pole 300 mA ELCB (RCCB) in BTS sites after removing existing faulty one etc as reqd.
Providing and Fixing of LED indication lamp after removing existing faulty one etc as reqd.
Arranging trolley/platform mounted accoustic type DG sets on daily rental basis of different capacities as per the load requirement in sites ,with required safety and technical requirements,including connecting the cable to control panel inside the BSNL site for using in times for DG failure /contingencies minimum 1 day and maximum of 5 days in a site ( specific approval of competant authority needed for further extension and diesel will be supplied by BSNL) The operating procedure shall be trained to the person deputed by BSNL for opearting the DG set. The capacity will be initmated by BSNL and shall be minimum and sufficient to meet the load requirement of site.
a) 15 kVA EA set
b) 30 kVA EA set
Total for Part A + Part B +Part C
ELECTROTEK ENGINEERS PVT LTD
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .