Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.9 LAccepted-AOC C 23 CC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹55.9 L+₹4.0 L (7.74%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹56.3 L+₹4.4 L (8.53%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | Rejected-Technical DEHRADUN | - | Rejected-Technical REJECT | |
| 5 | Rejected-Technical DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | Rejected-Technical REJECT |
Tender Value
₹62.5 L
EMD Value
₹1.2 L
Closing Date
9 Sept 2021, 6:00 pmClosed
CWE(HILLS) DEHRADUN
Headquarters Commander Works Engineers (Hills) Military Engineer Services, Mall Road, Dehradun Cantt
ADDITION ALTERATION CUM SPECIAL REPAIR TO JCOS OR MD ACCN AT MIL STN RAIWALA
2021_MES_465503_1
86322/RWL/E8
Open Tender
Civil Works
Item Rate
180 days
AGE(I) Raiwala
Class C Cat a i
6 documents required · 6 mandatory
₹1,000
AGE(I) Raiwala
₹1.2 L
Yes
28 Oct 2021
5 Aug 2021
11 Sept 2021
5 Aug 2021
9 Sept 2021
28 Aug 2021
5 Aug 2021 - 12 Aug 2021
Amount
Removal of existing roof treatment i.e APP membrane, and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed. Note :- The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
M&L 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with SBR Latex liquid polymer as water proofing compound ((mixed as per manufacture instructions & will be paid under relivent item of Sch A)) over and incl one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete/ mortar to old surface as per manufacturer direction and finishing the surface even and smooth (without using extra cement) as in roof padding / sunken floor to receive water proof treatment complete all as specified and directed. Note :- The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance Note : 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
Demolition of lime concrete in floors and paving exe 15 cm thick above ground floor (sunken floor) including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material and removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
M&L for Concrete angle-fillets provided with a radiaus of 75mm to 100 mm at junctions between roofs/chhajja/ sunken floor and vertical faces of walls (parapet, pillar for tank staging and other similar situations) to ease up about corners.with cement concrete 1:2:4 type B0 (Using 12.5mm stone aggregate) mixed with SBR Latex liquid polymer (mixed as per manufacture instructions & will be paid under relivent item of Sch A) including using form work (straight or curved) as required complete as per direction by Engr-in-Charge. (Note :- The work is required to be carried out upto double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers. The rates quoted shall deemed to be included for these items.)
Providing and application two coat of acrylic polymer modified cementitious flexible waterproof coating on horizontal and vertical surface of sunken floor after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge . Note : Ponding test after water proofing coating willl be done for 48 Hrs .
M&L for 15 mm thick cement plaster in CM 1:4 on floor and wall surface of sunken portion with polymer modified repair mortar mixed with SBR Latex liquid polymer (mixed as per manufacture instructions & will be paid under relivent item of Sch A).Complete all as specified and directed
M&L for providing 40 mm dia GI pipe spout projecting at least 300 mm beyond outer face of wall or as per direction of Engr-in-charge
M&L for lean concrete 1:5:10 type E-2(using 40 mm graded stone aggregate) as in filling of sunken portion complete all as specified and directed.Complete all as specified and directed
M&L for 30 mm thick PCC Type B-0, 1:2:4, (using 12.5 mm graded stone aggregate) as in floor mixed with mixed with SBR Latex liquid polymer(mixed as per manufacture instructions & will be paid under relivent item of Sch A).Complete all as specified and directed by Engineer in Charge .
Demolition and breaking up drain pipes AC/PVC 100mm bore alongwith fittings and accessories, jointed in cement mortar and taking out of wall, floor and trenches if required .complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes ( ISI Marked), single socketed in any length with rubber ring joints laid in trenches or in floors.complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes, ( ISI Marked), single socketed in any length with rubber ring joints laid in trenches or in floors.complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring ( ISI Marked) joints fixed to walls.complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring ( ISI Marked) joints fixed to walls.complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius ( ISI Marked) . complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius with access door ( ISI Marked) . complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius ( ISI Marked). complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius with access door ( ISI Marked). complete all as specified and directed.
S & F 110 mm PVC (SWR) WC connector with lip ring ( ISI Marked) .complete all as specified and directed.
S & F PVC (SWR) reducers of size 110 mm x75 mm ( ISI Marked) . complete all as specified and directed.
S & F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door ( ISI Marked) .complete all as specified and directed.
S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door ( ISI Marked) .complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Vent Cowl ( ISI Marked) . complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Multi floor trap including jointing with solvent cement ( ISI Marked) . complete all as specified and directed.
S & F 110 mm bore PVC (SWR) P Trap ( ISI Marked) . complete all as specified and directed.
S & F 75 mm bore PVC (SWR) floor Trap ( ISI Marked), , plain with grating inclding jointing with solvent cement .complete all as specified and directed.
S&F in repair stack clamps out of 50mmx 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to walls or roof for 75 mm pipe, complete all as specified and directed.
S&F in repair stack clamps out of 50mmx 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to walls or roof for 100 mm pipe, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any position not otherwise specifically provided for and including reinforcement required to facilitate demolition upto and including on the roof top/mumty/parapet/RCC chajjas/RCC water tank and removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
M&L RCC 1:2:4 type B-1 (using 20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc.Complete all as specified and directed
M&L RCC 1:1.5:3 type A-0 (using 12.5 mm graded stone aggregate) in Chajjas/fins /facia including one coat of SBR latex as bonding of old concrete to new concrete .Complete all as specified and directed. Note:- (i) (SBR) latex liquid polymer will be measured and paid seperately under relevant item of Sch-A. (ii) The work is required to be carried out at for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
Form work to soffits of suspended slab such as RCC shelves, RCC Chhajja , floor slab, landing and similar work( horizontal or sloping ) not execeeding 200 mm thick . Complete all as specified and directed
Fair finished flat Form work to edges of concrete flats, treads, breaks infloors, window cills, concrete railings, openings in concrete walls floor and roofs not exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or slopping and similar work . Complete all as specified and directed
M&L factory made ,70 mm thick , Precast steel fibre reinforced concrete (SFRC) of any shape and size, manhole/drain cover(medium duty) provided with handle , including 8 mm dia MS TMT bar @150mm c/c in both way and 0.80 mm thick MS sheet frame epoxy painted provided to manhole/drain cover to prevant from chipping of edge Complete all as specified and directed by Engineer in Charge .
M&L for mild steel TMT bars10mm dia, cut to length, bent to shape required including welding to old bar , cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm diaComplete all as specified and directed by Engineer in Charge .
M&L for mild steel deformed bars or TMT bars 6mm to 8mm dia, cut to length, bent to shape required including welding to old bar, cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia Complete all as specified and directed by Engineer in Charge .
Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15cm thickness ( below or above ground level ) and including removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
M&L cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) 75 mm thick as in plinth protection surface finished even and smooth without using extra cement including 4 mm thick glass dividing strip of figured glass, pin headed type, 73 mm wide inserted in position Complete all as specified and directed by Engineer in Charge .
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each.Complete all as specified and directed
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm but not exceeding 4.0 Sq.m each.Complete all as specified and directed
Taking down chowkhats or frames of any description exe 1.5 Sqm but not exceeding 4.0 Sq.m each and refixing in the other opening including providing new MS holdfast after repairing tightening and making good joints of frame Complete all as specified and directed by Engineer in Charge .
Taking down shutter of any description exc 1.00 sqm, n exe 2.00 Sqm each and refixing the shutters in other opening of any descrption after easing and adjusting , repairing , tightening the joints of frame of shutter, changing the location of hinges and making good old hinge location by packing etc complete all as specified and directed
Taking down shutter of any description not exc 1.00 sqm each and refixing the shutters in other opening of any descrption after easing and adjusting , repairing , tightening the joints of frame of shutter, changing the location of hinges and making good old hinge location by packing etc complete all as specified and directed
M&L Second class hard wood plain, solid, straight chowkats (SAL) and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints.Complete all as specified and directed by Engineer-in-charge
M&L for Powder Coated (minimum thickness of powder coating 50 micron), Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. Complete all as specified and directed by Engineer-in-charge
M&L Powder Coated (minimum thickness of powder coating 50 micron), Anodised aluminium window and ventilator shutters, side / top hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) Complete all as specified and directed by Engineer-in-charge
S&F for Glazing with plain sheet glass, ordinary quality, 5.5 mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane.Complete all as specified and directed by Engineer-in-charge
S&F for 1.25 mm thick pressed steel frame for doors with one or more rebated including necessary fixing lungs, hinges, lock, strike plates etc complete all as specified and size of frame 105 x60 mm. Complete all as specified and directed by Engineer in Charge .
S&F for 1.25 mm thick pressed steel frame for doors with one or more rebated including necessary fixing lungs, hinges, lock, strike plates etc complete all as specified and size of frame 125 x60 mm. Complete all as specified and directed
M & L for PCC 1:3:6 type C-0(12.50 mm thick graded stone agg) for filling the core of pressed steel door /window frames .Complete all as specified and directed by Engineer in Charge .
M&L for 35mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both side with teak wood lipping on edges of shutter Complete all as specified and directed
S&F for 0.9 mm thick decorative laminates surface finish one side colour and pattern as approved,fixed with approved adhesive as per manufacture instructions. Complete all as specified and directed by Engineer in Charge .
M&L for 35mm thick , factory made, plain framed, pannelled shutters (Two panel) with lock rail and style of 2nd class hard wood and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces with 2nd class hard wood moulded bead shall be provided and planted round the panels for one side. The size of rail and stile as per IS : 1003 (Part-I), Kiln seasoned and chemically pressure treated Complete all as specified and directed by Engineer in Charge .
S & F 2nd class hard wood 30 mm thick glazed and skeleton shutters open rebated and prepared to rceieve glass, gauze,etc. (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred moulded beads for securing glass/gauze,etc, size of members of shutters as specified in SSR Part-1, Section 8, clause 8.24 (a) etc Complete all as specified and directed by Engineer in Charge .
S & F for fibre glass reinforced plastic (FRP) Door frames three lagged of cross section 90mm x 45mm having single rebate of 32mm x 15mm to receive shutter of 30mm thickness. The laminate door frame moulded with fire retardant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass from all sides. MS stay shall be provided at the bottom to steady the frame. Complete all as specified and directed. Make - M/s Ashwini and Sons Murad nagar, TATA FRP Doors Mumbai, AGEWS Ahemdabad Gujarat, Ashish Industries Ghaziabad
S & F FRP Door shutter 30mm thick glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacturer. Made with fire retardant grade unsaturated polyester resin moulded to 3mm thick FRP laminat for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP panels. complete all as specified and directed : Make - M/s Ashwini and Sons Murad nagar, TATA FRP Doors Mumbai, AGEWS Ahemdabad Gujarat, Ashish Industries Ghaziabad
S&F for 18 mm thick , prelaminated medium density fibre (MDF) , interior grade, prelaminated one side with decorative choice lamination and other side balancing white with lamination fixed with screw to timber/ steel frame work as in CB shutter, shelves etc with PVC liping on all exposed edges on same texture and shade. Stainless steel cleat of suitable size will be use to fix the shelves of CB and cabinets.
M&L for Plain fillets of second class hard wood ( SAL)(suitable for joiner’s and carpenter’s work, locally available) section area exceeding 3 Sq.cm and not exceeding 6 Sq.cm, square, bull nosed,splayed, champhered, moulded or rounded one eadge or face, wrought secured with nailsComplete all as specified and directed by Engineer in Charge .
S & F for Aluminium anodized barrel tower bolt of 12 mm dia and 300 mm length of extruded section .(ISI Marked). Complete all as specified and directed by Engineer in Charge .
S & F, in repair, for Aluminium anodized barrel tower bolt of 12 mm dia and 300 mm length of extruded section (ISI Marked) .Complete all as specified and directed by Engineer in Charge .
S & F for Aluminium anodized barrel tower bolt of 12 mm dia and 200 mm length of extruded section (ISI Marked). Complete all as specified and directed
S & F. in repair, for Aluminium anodized barrel tower bolt of 12 mm dia and 200 mm length of extruded section (ISI Marked) .Complete all as specified and directed
S&F for Extruded Aluminium alloy handles,fabricated type, anodised 125 mm long,(ISI Marked) all as specified and directed.
S&F, in repair, for Extruded Aluminium alloy handles,fabricated type, anodised 125 mm long,(ISI Marked) all as specified and directed
S & F for Aluminium alloy anodised sliding door bolt, of 16 mm dia and size 300mm (ISI Marked) , with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy.. Complete all as specified and directed
S & F for Aluminium alloy anodised sliding door bolt, of 16 mm dia and size 300mm (ISI Marked) , with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy, fixed in repair. Complete all as specified and directed by Engineer in Charge .
S&F Stainless non megnetic steel butt hinges of size 100mm.(ISI Marked). Complete all as specified and directed by Engineer in Charge
S&F for Continuous (piano) hinges, mild steel, bright finish or electrogalvanised ,Width of flap (when open), 40 mm . (ISI Marked). Complete all as specified and directed
S&F for hasp and staples,size 100mm, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws, fixed in repairs (ISI Marked) .Complete all as specified and directed
S&F for Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm (ISI Marked) .Complete all as specified and directed
S&F for Ball catches with 8mm dia steel ball, and brass body and striking plate including letting inComplete all as specified and directed by Engineer in Charge .
S&F, in repair, for Stainless steel wire cloth non megentic of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples. Complete all as specified and directed by Engineer in Charge .
S&F for Stainless steel wire cloth non megnetic of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples fixed to door/window shutter Complete all as specified and directed by Engineer in Charge .
S&F for Stainless steel curtain rod, 25mm dia with fixing brackets and decorative type knobs both side of each rod ,incl taking down old curtain rod or pelmet boxes..Complete all as specified and directed by Engineer in Charge . Note :- Measurement will be taken between end point of knobs.
S&F for Aluminium door seal upto 1000 mm long on bottom of door fixed with nails. Complete all as specified and directed
S & F for Magic eye for main door Complete all as specified and directed
M&L for Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0. Complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames glazed with putty or fixed with beads or from metal frames including punching or drilling out old glazing pins /spring clips and providing and fixing new one.Complete all as specified and directed
S&F for Glazing with plain sheet glass, ordinary quality, 4 mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane.Complete all as specified and directed
S&F for Glazing with figured glass (Frosted), pin head type, 4 mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane.Complete all as specified and directed
S&F aluminium Hat pegs, solid body,125mm to 175 mm complete all as specified and directed.
S&F aluminium Hat and coat hooks,solid body, 175mm to 250 mm complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width & girth not otherwise described and applying two coat of synthetic enamel paint (Ist quality)over a coat of red oxid primer. Complete all as specified and directed
Preparation of New wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint (Ist quality) over a coat of pink primer. Complete all as specified and directed
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated wood and wood based sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
M&L Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan to any radius in half brick thick built in cement sand mortar 1:4 complete all as specified.
M&L Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:4 complete all as specified.
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
M&L rendering 5 mm thick in CM 1:3 in ceiling / Chhajja's finished even and smooth (without using extra cement). Complete all as specified and directed
M&L for complete removal of existing treatment and preparation of old surface plastered or unplastered and applying two coat of white wash on ceiling complete all as specified and as directed by Engr-in-Charge.
M&L for white washing three coats on ceiling incl preparation of newly plastered surfaces.complete all as specified and directed by Engr In Charge.
M&L Rendering 15 mm thick cement plaster on concrete brick walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid seperately.
Supply only water proofing compound liquid ISI marked as approved by AGE(I) . Complete all as specified and directed by Engineer in Charge . .
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L Rendering 15 mm thick on fair faces of brick work or concrete walls internal surfaces in CM 1:6 finished to even & fair without using extra cement.Complete all as specified and directed by Engineer in Charge .
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper using roller all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge . Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises from MoD all as specified and directed.
Roughening surfaces of old concrete floor by tucking, picking, sweeping clean and washing down with water to remove dust, etc. to receive the screed layer for laying floor tile. Complete all as specified and directed
M&L for coloured vitrified tiles of any design and pattern, 600x600x9 to10 mm thick, as in floor etc incl 15 mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B1b with average water absorption between 0.08% to 3%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 4.0% (Max deviation). Centre & Edge curvature and warpage + 0.20% (Max Deviation). Breaking strength 1200 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I) Complete all as specified and directed
M&L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square/rectangular) area of each tile exe 0.11 sqm but not exe 0.18, in floor etc incl 15mm thick screed bed in CM 1:6 , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I)
M&L for Non- skid coloured ceramic tiles of any design and pattern, 300X300X7 to 8 mm thick, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles.Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note:- Shade of the tiles including Colour, design and pattern shall be approved by GE .Complete all as specified and directed
M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8 mm thick, as in dado etc incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I) .Complete all as specified and directed
M & L for 18-20 mm thick machine cut pre polished kota stone slab as in tread / cill in full length in single peace without joint, with groove cutting in triple line of stair width of stair case over and incl 20 mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing and polishing incl full round bull nosing complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, approns, kitchen plateform / shelves etc.Complete all as specified and directed
M & L of 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl 15 mm thick screed bed in cement mortar 1:6 incl full round bull nosing complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tank 1000 liters capacity, double layer construction out door type ISI Marked (cylindrical vertical closed top), hoisted & fixed in position including tank cover with looking arrangment all fittings complete all as specified and as directed.
S&F 20mm dia ball valve high pressure PTMT with epoxy coated aluminium rod & high pressure plastic ball screwed for iron pipe and fixed.complete all as specified and directed..
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia .complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .complete all as specified and directed.
M&L for cutting chases on brick or concrete surface for concealed water tubing or / similar work of girth n.exc 10cm including making good of disturbed surfaces with PCC 1:2:4 type B0 using 12.5 mm graded aggregate complete all as specified and directed.
S& F for GI tubing 15mm bore, medium grade ISI marked with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions, including short lengths etc.) ( heavy grade ISI Marked) , fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and directed.
S& F for GI tubing 20 mm bore, medium grade ISI marked with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions, including short lengths etc.) ( heavy grade ISI Marked) , fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and directed.
Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
S & F 15 mm dia Gun Metal, globe or Gate Valve class 150 with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs (ISI Marked ) .Complete all as specified and directed
S & F 20 mm dia Gun Metal, globe or Gate Valve class 150 with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs (ISI Marked ) .Complete all as specified and directed
S&F Stop angle valves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type) of size 15mm bore, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete (fixed in repairs) Make : Jaquar Essco model Cat Part No MQT-526KN or equivalent model of make MARC or Hindware .complete all as specified and directed.Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
S&F in repair bib tap cast copper alloy with crutch or butter fly handle, screwed down for iron pipe 15 mm bore of tubing fancy type cromium plated (ISI Marked).Make : Jaquar Essco model Cat Part No MQT-512KN or equivalent model of make MARC or Hindware complete all as specified and directed. ( Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
S&F in repair Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure with long screwed shanks and fly-nuts, screwed for iron pipe screwed down for 15 mm dia bore GI pipe complete all as specified and directed Make : Jaquar Essco model Cat Part No MQT-508 KN or equivalent model of make MARC or Hindware ( Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
S&F in repair, Stainless steel non megnatic Towel Rail 20 mm dia, 600 mm long fixed with and including Chromimum plated brass screws and wooden plastic cleats. Make : Jaquar Essco model Cat Part No AEC-1111N or equivalent model of make MARC or Hindware Complete all as specified and directed . Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, with arm including fixing to steel pipe or union. complete all as specified and directed Make of shower rose : Jaquar Essco model Cat Part No EOS-542A,Make of shower arm : Jaquar Essco model Cat Part No ALE-536A or equivalent model of make MARC or Hindware .Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site
S & F for Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long. Make Pryag Cat Part No.BEA -45 or equiavlent in Pearl ,polytuff, commander or equiavlent as approved by AGE(I) Complete all as specified and directed
S&F for PVC Connections 15mm size with PTMT nuts of length 600 mm (ISI Marked). complete all as specified and directed.
S&F in repair Wash hand basin 555x410mm vitreous china (flat back type) incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fittings.Make : Jaquar Essco model Cat Part No ECS-WHT-801 or equivalent model of make MARC or Hindware complete all as specified and directed.
S & F for Grating , stainless steel with or without hole, round 100/125 mm dia chromoum plated.(fixed in repairs)Complete all as specified and directed
S&F in repairs PVC valveless, syphonic action type flushing cistern (Dual action ISI Marked), low level , white, with inlet ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity of approved make .Complete all as specified and directed
S&F in repairs Vitreous china Squatting pan (Ist quality) , 'Orissa pattern, white, with integral foot rest excluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete including making good to floor. Make : Jaquar Essco model Cat Part No ECS-WHT-451 or equivalent model of make MARC or Hindware . Complete all as specified and directed
S&F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover, incl all joints. Make : Jaquar Essco model Cat Part No ECS-WHT-551SSPP or equivalent model of make MARC or Hindware complete all as specified and directed.
S&F 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe fixed in repair. complete all as specified and directed.Make : Jaquar Essco model Cat Part No MQT--516AKN or equivalent model of make MARC or Hindware Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site
Supply & fix in repair wall mixer with L bend pipe for connection to over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15mm bore pipes complete all as specified and directed.Make : Jaquar Essco model Cat Part No MQT--517BKN or equivalent model of make MARC or Hindware Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site
S&F in repair Hand shower ( health faucet) with 1 mtr long long Easy flex Tube in chrome Finish and wall hook with N.R.V( Back Flow Preventer) tube & hook (braded Tube) Make : Jaquar model Cat Part No ALD-579 or equivalent model of make MARC or Hindware complete all as specified and directed. Note- Chromium plated fitting shall be brought in store yard first as approved by AGE(I) and will be issued subsequently for fixing at site .
S&F in repairs toilet paper holder, chromium plated fixed to wall with chromium plated (CP) brass screws Make : Jaquar model Cat Part No ACN-1151N or equivalent model of make MARC or Hindware . Complete all as specified and directed by Engineer in Charge . Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site
S&F 32 mm dia low density polyethylene pipe (LDPE) of pressure rating @ 6Kg per Cm Square fixed to walls, ceilings or in floors etc.Complete all as specified and directed by Engineer in Charge .
Taking out existing stainless steel kitchen sink with drainage board and refixing the same after cleaning with cleaning powder with plugs, washers & wastes incl bedding in cement mortar to dwraf wall or incl fixing cantilever brackets and connecting union to pipe.Complete all as specified and directed by Engineer in Charge .
S & F in repairs Sinks with drainage board( ISI marked only) made of stainless steel 1.0 mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 and bowl size 410mm x 330 mm x 160mm.Make Pryag cat Part No. 1239 D or equivalent in Bluestar, Nirali Complete all as specified and directed by Engineer in Charge . Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site
S&F in repair, for Stainless steel kitchen plate rack made out of 0.9 mm thick steel sheet of over all size 750x600x250mm fixed with steel screws and steel rawal plugs Complete all as specified and directed
S & F Rolled Mild Steel sections confirming to Fe 410 - W (grade E 250 Quality)as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates. Complete all as specified and directed by Engineer in Charge .
S & F Expanded metal cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia., or fixing with steel staples to wood or steel members, weight not exceeding 4 Kg per Sq. M.Complete all as specified and directed by Engineer in Charge .
M&L for post construction Anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors.Complete all as specified and directed by Engineer in Charge .
M&L for post construction Anti termite treatmentAlong the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron .Complete all as specified and directed by Engineer in Charge .
Demolition and breaking up drain pipes , 100 mm dia (Salt glazed stone ware or Reinforced concrete) set in cement mortar. .Complete all as specified and directed by Engineer in Charge .
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation in hard/ dense soil and getting out.Complete all as specified and directed by Engineer in Charge .
Demolition of cement concrete (unreinforced) of any description & any position and not otherwise specifically provided for .and removing unserviceable material,outside of A 1 defence land complete all as specified and directed
M&L Concrete bed to drain pipe 100mm dia incl. packing under and haunching against the sides of pipe PCC 1:4:8 type D-2 using 40 mm graded stone aggregate .Complete all as specified and directed by Engineer in Charge .
M&L 100 mm bore salt glazed stoneware drain pipes Grade A (ISI marked) laid in trenches and jointed with collars with following sizes laid on concrete bed,Complete all as specified and directed by Engineer in Charge .
Returning filling in including spreading, levelling , watering and well ramming n exc. 25 cm in layers (Soil) Complete all as specified and directed by Engineer in Charge .
Removal of excavated surplus (soils) at a distance exc. 1.5 Km but n. exc 5.0 Km. Complete all as specified and directed by Engineer in Charge .
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 100/150mm dia pipes complete all as specified and directed.
M & L for cutting of bushes small trees (Peepal small plants etc) trunks shrubs of any dia and girth from roof projection, chajjas , wall junction parapet up to double story buildings etc at any height by necessary demoliton of brick work etc if requried and making good distrubed surfaces to match with existing finihes with and incl material and labore in CM 1:4 mixed with WPC /PCC 1:3:6 type B0 /Bk work in CM 1:4 as required at site Complete all as specified and directed by Engineer in Charge .
M & L for shifting aside of MS monkey case of any size & weight for repair / replacement of water tank, GI pipe, tank staging & refixing the same as required at site Complete all as specified and directed by Engineer in Charge .
S&F heavy duty , soft closing Telescopic channels of size 20-22 inch complete all as specified and as directed. Make:- Hettich, Kaff, Godrej.
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa (AZ -150) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Supply only SBR Latex liquid polymer of approved make complete all as specified & directed.
Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each . complete all as specified and as directed.
Providing and fixing windows & ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated(PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and flymesh shutter, 74 X 60mm outer frame , Mullion 72 x 49mm, Glazed shutter 48 x 22mm, Flymesh 41 x 22mm, Beading with round ends for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps . Glass of 4mm thick plain float glass fitted with Ethylene Propylene Diamine Monomer in glazed shutter and wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Black Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with crca of zinc phosphate coat.Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter.Window shall be provided with Powder coated MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat with countersunk holes at both vertical ends . Gap between the bars should not be more than 150mm . Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screws after drilling in walls. VC Black Gypsum Drywall screws should be used while fixng corner brackets,stay,hinges,mullion caps of windows. . Windows to be procured from any of the below mentioned companies- i)_Ashwani and sons, 1246/2 Meerut Road,Morta, Murad nagar-201003 ii)TATA Steel-Mumbai iii)Jindal,2-32,Gurgaon, Haryana-122001iv) Ashish Industries, R-4/66, Raj Nagar, Ghaziabad , Ph-9891542779
M&L for Plain fillets of second class hard wood ( SAL)(suitable for joiner’s and carpenter’s work, locally available) section area exceeding 6 Sq.cm and not exceeding 13 Sq.cm, wrought square, rectangular secured with nails Complete all as specified and directed by Engineer in Charge.
S&F for Extruded Aluminium alloy handles,fabricated type, anodised 150 mm long,(ISI Marked) all as specified and directed.
S&F, in repair, for Extruded Aluminium alloy handles,fabricated type, anodised 150 mm long,(ISI Marked) all as specified and directed
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated steel sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) complete all as specified and directed.
Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m
Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, using cement mortar 1:4 complete
Material and labour for coloured vitrified tiles of any design and pattern, 10mm thick, as in dado/skirting etc incl 10 mm thick rendering in CM 1:4 incl dismantling of tiles/skirting/dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B1b with average water absorption between 0.08% to 3%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 4.0% (Max deviation). Centre & Edge curvature and warpage + 0.20% (Max Deviation). Breaking strength 1200 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note: Shade of the tiles including Colour, design and pattern shall be got approved by GE. Complete all as specified and directed
M&L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square/rectangular) area of each tile exe 0.11 sqm but not exe 0.18, as in dado/skirting etc incl 10 mm thick rendering in CM 1:4 incl dismantling of tiles/skirting/dado, , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I)
M & L for 10-12 mm thick machine cut pre polished kota stone slab as in riser of steps, skirting in full length in single peace without joint, of stair width laid over and incl 10 mm thick rendering of CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade including necessary grinding, rubbing and polishing complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc..Complete all as specified and directed by Engineer in Charge .
Taking down service/submain wire of any size fixed in any position,complete all as specified and directed by Engineer -in-charge, Complete all as specified and directed by Engineer in Charge .
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed rigid PVC conduit(ISI marked) ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) including metal flush box made of GI sheet and white cover complete of suitable size complete all as specified and directed for the following. Note: Flush box and cover plate should be of same make all as approved for switches/sockets.
(a) One light/fan point controlled by one No modular type switch 6 Amps single pole one way
(b)One bell point controlled by one No of bell push .
(c ) One 5 pin 5/6 Amp socket outlet point on independent board controlled by one no of one way switch single pole 5/6 amps.
(d) One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sqmm size
(e) one light point controlled by two no of two way switch two way point
All as per item No 173 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 V grade PVC insulated FRLSH but unsheathed single core for 16 Amps power point on independent board and 2.5 sqmm FRLSH cable as earthwire.Complete all as specified and directed by Engineer in Charge Note: Flush box and cover plate should be of same make all as approved for switches/sockets. .
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand cat No: 6734 01/ Indoasian Cat No: 800000 or equivalent make of L&T/Havells
S & F switch Modular single pole, two way 6 Amps , 1 module, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand cat No: 6734 02/ Indoasian Cat No: 800001 or equivalent make of L&T/Havells
Supply and fix Modular switch 1 way 16 Amps, 1 module, 230 volts, 50 hz white/ivory finish all as specified and directed by Engr-in-Charge. Make: Legrand cat No: 6734 11/ Indoasian Cat No: 800002 or equivalent make of L&T /Havells
Supply and fix Modular Socket outlet, 6A - 3 pin combined, 2 module ISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand cat No: 6734 52 / Indoasian cat no: 800020 or equivalent make of L&T/Havells
Supply and fix Modular Socket outlet, 16A - 6 pin combined, 2 module ISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge. Make: Legrand cat No: 6734 55/ Indoasian cat No 800022 or equivalent make of L&T/Havells .
M&L ceiling rose 3 terminal / PVC/ polycarbonate,ISI marked 230 volts,50 Hz isolated body all as specified and directed Make : Anchor Cat part No.14307/ Cona Cat Part No.7091 / or equivalent in Havells.
S & F bell push Modular single pole, one way 6 Amps , 1 module, ISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand cat No: 6734 06 / Indoasian cat no: 800007 or equivalent make of L&T /Havells.
Supply and fixing LED lights fitting 1X20 watt ,4 ft polycarbonate housing, translucent diffuser with LED light source,2200 Lumens,natural whitesurge protection range-2KV voltage protection range-120-280VAC,2 years warranty ,system efficacy not less than110Lm/Watt for the fitting,power factor >.95,total harmonic distortion< 20% color renderingindex>80,coefficientcolor Temperature-6500K,fixed on site withall accessories all as specified & directed cat NoSZSLBMX020 of Shakti or equivalent in Havells/Wipro.
Supply and fix sheet metal enclosures with metal socket and plug top Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps all as specified and directed by Engr-in-Charge.
Taking down defective distribution Board including MCBs and wooden boards all as directed and S & F distribution board factory made SPN 16 way in, 240 Volts, with 200 Amps rated bus bar, Double door metal type suitable for fixing MCBs including making good the surfaces to match with the existing all as specified & directed.
Taking down defective distribution Board including MCBs and wooden boards all as directed and S & F distribution board factory made TPN 04 way in, 415 Volts, with 200 Amps rated bus bar, Double door metal type suitable for fixing MCBs including making good the surfaces to match with the existing all as specified & directed.
Supply and fixing 240V, 10 KA 'B' curve miniature, circuit breaker (MCB) of single pole and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning all as specified and directed by Engr-in-Charge.
Supply and fixing 415V 10KA 'B' curve miniature, circuit breaker (MCB) of Triple pole 6-32 Amps current carrying capacity in the DB complete with connection testing and commissioning all as specified and directed by Engr-in-Charge.
S& F CRCA sheet steel powder cated double door VTPN DB , 6 way , with insulated vertical phase bus bars, neutral bars with shrouds, earth bars, sticking saddles, cement spill protector, color coded interconnecting wire set cable ties,blanking plates and circuit identification lables with provision for 01 No of TPN MCCB as incomer and MCB SP/TP MCBs as outgoings all as specified and directed by Engr-in-Charge. (Note: MCCBs and MCBs will be measured and paid separately. )
S & F MCCB TPN pole, 415 Volt, 25 KA Breaking capacity, 40 Amps capacity, thermal magnetic adjustable type all as specified and directed by Engr-in-Charge.
S & F Isolator TPN 415 Volts 06-32 Amps complete all as specified and directed by Engr-in-Charge.
S & F Isolator SPN, 230 Volts 32-40 Amps complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring with four run of single core multistranded PVC insulated copper conductor of size 6 sqmm 1100 volt grade drown into PVC Rigid conduit of 20/25 mm dia, ISI marked including 6.0 Sqmm. PVC multi stranded cable in green colour for continieous earthing and making good the disturbed surfaces of wall /floor/ ceiling to match with existing surfaces.all as specified and directed. Note : Five runs of 6 Sqmm PVC cable and one runs of PVC conduit shall be measured as one unit.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
M & L for laying for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing as required 4 mm diagalvanised and connecting GI steel wire 4.0 mm dia on earth pit Complete all as specified and directed by Engineer in Charge .
Supply and fix Lamp holder, PVC/Polycarbonate, type with back plate suitable for batten fittings all as specified and directed by Engr-in-charge.
Supply and fix new LED building security light 1X20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy > 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including fixed on ground with 02 Nos MS clamp made out of F1 40 x 6 mm or as directed including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from distribution box to light complete all as specified and as directed by Engr-in-Charge (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABL approved laboratory. (iii) The fitting should have BIS, CRSno
M & L buzzer, ding dong, SP 240 Volts compelte including rectangular first class hard wood board of size 150 mm x 100 mm x 50 mm complete all as specified and directed by Engr-in-Charge.
M &L bell electronic AC , SP 240 volts complete including rectanglualr first class hard wood board of size 150 mm x 100 mm x 50 mm complete all as specified and directed by Engr-in-charge.
S & F Connect T.V Outlet mini, ISI marked, .Complete all as specified and directed by Engineer in Charge .
S & F Telephone Jack mini, ISI marked, complete all as specified and directed by Engineer in Charge .
M & L for disconnecting all electrical connection and taking down old corroded steel meter box from existing site, S & F new self supporting wall mounted totally enclosed compartmentalised double door front openable powder coated dust and vermin proof panel board of size suitable for fixing 5 Nos of KWH meter made out of 2 mm thick CRCA sheet and built upon rigid frame work having front doors with neoprence rubber gasket, earthing strip point at side, bottom detachable gland plate consisting of sufficient nos of circular cable entry holes at bottom only with suitable PVC insulated cables of adequate size including connectinos complete with suitable size bolts and washers etc. Fixing of KWH meter, necessary connection to meters and MCB DB's and testing of meter, making the disturbed surface good as directed by Engr-in-Charge.
All as per item No. 206 above for fixing 3 Nos of KWH meter complete all as specified and directed by Engr-in-Charge.
Supply and fix three phase electronic meters temper proof LCD display with polycarbonate cover 3 x 240 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH all as specified and directed by Engr-in-Charge.
M & L for telephone wire with PVC twin parellel flat wire of size 23/0.0048 BC and including rigid non metallic PVC conduit 20 mm dia or higher size medium grade ISI marked concealed (surface only on roof & colomns) complete all accessories/fittings and MS box thickness not less than 1.2 mm thick plastic laminated hard glassy surface sheet cover concealed in wall with brass screws & washers complete all as specified and directed.
M & L for dish co-axial RG-59 with foam cable including rigid non metallic PVC conduit 20 mm dia or higher size medium grade ISI marked concealed (surface only on roof & colomns) complete with all accessoies /fittings and MS box thickness not less than 1.2 mm covered with 3 mm thick plascti laminated hard glassy surface sheet cover concealed in wall with brass screws & washers complete all as specifiede and directed by Engr-in-Charge.
S&F LED tube light batten 09 watts 2 feet,220 v AC polycarbonate housing, translucent dffuser with LED light source, 2200 lumen, natural white, surge protection range 2KV voltage protection range 120-280 VAC, 2 year warranty , system efficancy not less than 110 Lm/watt for the fitting, power factor>0.95 total harmonic distoration < less 20%colour rendering index>80, coefficient colour temp 6500 K, fixed on site with all accessories all as specified and directed Make Shakti cat part No SZSLBMX010 or equivalent in Havells, wipro or bajaj LM79 and LM80 reports to be produced. BIS certification must. Complete all as specified and directed by Engineer in Charge.
Labour only for Fixing energy efficient ceiling fan with BLDC motor and blades, 1200 mm sweep,complete all as specified and directed. Note:- ceiling fan and accessories fitting shall be issued by department free for fixing under Sch B.
Labour only for Fixing electric water heater,storage type steel body with capacity 25 litre,complete with all accessories such as connection piece, anchor fastners etc.complete all as specified and directed. Note:- Water heater shall be issued by department with free for fixing under Sch B
S & F Exhaust fan 300mm sweep, wall mounted Single phase 230 volts, 50Hz, 1000RPM, Air delivery 1850m3/hr, noise level 55 db to 60db with double ball bearings. Frame, blade with mounting accessories, aerodynamically desgined blade, metallic body with bird guard and louvers, pre wired necessary core cutting of wall as per size required and making good the disturbed surface. Compete all as specified and directed by Engineer-in- Charge Note:- Exhaust fan shall have warranty for minium 02( two years).
S & F Fresh air fan (Air Flow fan) 200mm sweep, single phase, 230 volts, 50Hz, 900-1350RPM, Air flow 520cumh, manufacturerd with special grade plastic, noise level 42 db to 50 db arerodynamically designed and balanced blade ( no of blades 05 No.) alongwith gravity shutters consumption of power (32-40) watt, Pre wired including suitable size of core cutting of wall as per size required and making good the disturbed surface. Compete all as specified and directed by Engineer-in- Charge Make Havells/Crompton/ Bajaj. Note:- Fresh air fan shall have warranty for minium 02( two years).
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor of size 4 sqmm 1100 volt grade drown into PVC Rigid conduit of suitable 20/25 mm dia, ISI marked including 4.0 Sqmm. PVC multi standard cable in green colour for continieous earthing and making good the disturbed surfaces of wall /floor/ ceiling to match with existing surfaces.all as specified and directed. Note : Three runs of 4 Sqmm PVC cable and one run of PVC conduit shall be measured as one length.
Material and labour for fixing or passing through pipe, laid in trenches, fixed on wall, , XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 25 sqmm 4 core with required aluminium cable lugs, lugs should be properly crimmped with crimpping tools, cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirement all as specified and directed. by Engr-in-charge.
Excavation in trenches for taking out/laying of cable and pipe line not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide in soft/loose Complete all as specified and directed by Engineer in Charge .
Excavation in trenches for taking out/laying of cable and pipe line not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide in Hard/dense soil Complete all as specified and directed by Engineer in Charge .
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed by Enger -in- charge
M&L for fine dry sand cushioning for underground cable by providing layers of sand 8 cm before laying and 15 cm deep after laying the cable including streching the cable (measurement to be taken after punning down consolidated thickness). complete all as specified and directed.
M&L for cable protection bricks common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches all as specified and directed at site.complete all as specified and directed.
M&L for road cutting and making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) of 150mm X 100mm inrespect of width and thickness complete all as directed by Enger -in- charge.
Supplying, laying & jointing GI water tubing, 40 mm bore ISI marked , light grade as in sleeving etc laid in trenches / pole post /under culvert/ under road etc. for cable protection complete all as specified and directed .
Returning, filling including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in each layer in any type of soil.Complete all as specified and directed by Engineer in Charge .
Sahil Builders
P K ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .