Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC HARIGAON PO NIKAMUL SATRA DIST SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹12.6 L+₹17,468 (1.41%)Rejected-AOC AIR FORCE ROAD GOROIMARI PO HALESWAR TEZPUR DISTT SONITPUR PIN 784104 ASSAM | SONITPUR | ASSAM | 784104 | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹12.7 L+₹26,065.50 (2.10%)Rejected-AOC VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹13.0 L+₹57,627.70 (4.64%)Rejected-AOC JYOTISH ROAD TEZPUR DISTT SONITPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 5 | L5₹13.1 L+₹67,320 (5.42%)Rejected-AOC AIR FORCE ROAD GORAIMARI HALESHWAR TEZPUR SONITPUR ASSAM 784104 | SONITPUR | ASSAM | 784104 | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
18 Nov 2020, 6:00 pmClosed
GE AFS TEZPUR
GE AFS TEZPUR, PO- SALONIBARI, DISTT- SONITPUR,ASSAM-784104
SPECIAL REPAIR TO INTERNAL WIIRING OF CERTAIN BUILDINGS AT AF STATION TEZPUR UNDER GE AF TEZPUR
2020_MES_387940_1
8527/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE AFS TEZPUR
Class E Cat b(i)
6 documents required · 6 mandatory
₹500
Yes
GER AFS TEZPUR
₹29,000
Yes
23 Nov 2020
19 Oct 2020
20 Nov 2020
19 Oct 2020
18 Nov 2020
3 Nov 2020
19 Oct 2020 - 26 Oct 2020
Amount
Taking down carefully copper/ aluminium point wiring (light/fan/bell/ socket or power point) complete inclusive of all fittings such as switches, ceiling roses, pendants, regulators, sockets, fittings etc. removing materials from site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed. Note: Obtained serviceable fittings shall be fix under items No.22 to 30.
Taking down carefully sub main wiring of any type and size including fittings and fixtures, removing materials from site complete all as directed.
Disconnecting from electric circuit and taking out existing unserviceable SFUS, MCB DB SPN/ TPN or change over switches etc any number of ways including MCB etc removing materials from site and making good disturbed surfaces of floors/ walls/ ceiling etc complete all as directed.
Materials and labour point wiring with 1.5 Sqmm PVC insulated and unsheathed multistranded FRLS copper conductor cable 1100 volts grade, single core, drawn through existing PVC/ steel concealled conduit not less than 20mm size complete with all fittings and accessories, fixed to walls/ ceiling, including sunk cast type pressed steel terminal boxes 1.25mm thick with 2.2 mm plastic laminated sheet (Hylem) top cover for mounting switches/ regulator etc including 1.5 Sqmm PVC insulated unsheathed multistranded (green colour) copper conductor cable 1100 volts grade, single core, earth continuity conductor connected to common earth dolly for one light point/ one fan point/Call Bell Point controlled by one one way switch complete all as specified and as directed.
All as per serial item No. 4 here-in-before but wiring with 1.5 Sqmm copper cable drawn through existing PVC/ steel concealled conduit for two way switches.
All as per serial item No. 4 here-in-before but for one 3 pin 5 amps switch socket out let on independent board.
All as per serial item No. 4 here-in-before but for one 3 pin 5 amps socket out let on same board with other switch
All as per serial item No.4 here-in-before but wiring with 2.5 Sqmm including 2.5 Sqmm PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 volts grade, single core earth continuity conductor connected to common earth dolly for one 3/5 pin 15 amps switch socket out let on independent board.
All as per serial item No. 4 here-in-before but wiring with 1.5 Sqmm copper cable drawn through casing caping.
All as per serial item No.4 here-in-before but wiring with 1.5 Sqmm copper cable drawn through casing caping for two way switches.
All as per serial item No. 4 here-in-before but wiring with 1.5 Sqmm copper cable drawn through casing caping for one 3 pin 5 amps switch socket combination on independent board.
All as per serial item No. 4 here-in-before but wiring with 2.5 Sqmm copper cable including 1.5 Sqmm earth continuity conductor connected to common earth dolly drawn through casing caping for one 3/5 pin 15 amps switch socket combination on independent board.
S&F switch piano, flush button single pole one way 5 Amp complete all as specified and as directed.
S&Fswitch piano, flush button single pole two way 5 Amp complete all as specified and as directed.
S&F bell push, flush type 5 Amp complete all as specified and as directed.
S&F socket out let 3 pin 5 Amps, flush type complete all as specified and as directed
S&F switch socket combination 2 in 1, 3 pin 5 Amp flush type universal complete all as specified and as directed.
S&F switch socket combination 2 in 1, 3 pin 5 and 15 Amp flush type universal complete all as specified and as directed.
M&L ceiling rose, surface bakelite, 65mm x50mm three terminals complete all as specified and as directed.
S&F fan regulator electronic type rotary step, 120/280 volts complete all as specified and as directed.
S&F of call bell multi music type complete all as specified and as directed.
Refixing of switch piano/modular switch (Obtained from item No.01) flush button single pole one way 5 Amp with complete electrical connection complete all as specified and as directed.
Refixing of switch piano/modular switch (Obtained from item No.01) flush button single pole two way 5 Amp with complete electrical connection complete all as specified and as directed.
Refixing of switch socket combination 2 in 1, 3 pin 5 Amp (Obtained from item No.01) flush type (normal/modular) with complete electrical connection complete all as specified and as directed.
Refixing of socket out let 3 pin 5 Amps (Obtained from item No.01) flush type (normal/modular) with complete electrical connection complete all as specified and as directed.
Refixing of switch socket combination 2 in 1, 3 pin 5 and 15 Amp (Obtained from item No.01) flush type (normal/modular) with complete electrical connection complete all as specified and as directed.
Refixing of bell push, flush type 5 Amp (Obtained from item No.01) (normal/modular) with complete electrical connection complete all as specified and as directed.
Refixing of fan regulator electronic type rotary step (Obtained from item No.01)(normal/modular) with complete electrical connection complete all as specified and as directed.
Refixing of ceiling rose (Obtained from item No.01) surface bakelite, 65mm x50mm three terminals with complete electrical connection complete all as specified and as directed.
Refixing of call bell multi music type (Obtained from item No.01) with complete electrical connection complete all as specified and as directed.
S&F LED batten with tube 1 x 20 Watt, 6500K, System Luminous Efficacy more than 100 lm/W with high quality aluminium extruded with decorative end caps with five year warranty etc complete all as specified and directed. Make: Jaquar, Model No. LGLZ01X020XC or equivalent in model in Philips / Wipro/GE/Crompton Greaves
S&F nero surface mounted downlight round/Square LED panel aluminium die cast housing 12 watt LED 6500K complete all as specified as directed. Make: Jaquar Philips / Wipro/GE/Crompton Greaves
S&F lamp holder, insulated body, angular type with back plate for batten fitting including LED lamp 9 Watt complete all as specified and as directed. Make: Jaquar Philips / Wipro/GE/Crompton Greaves
S&F in repair sheet metal enclosures MCB DB 8 way SPN, double door, with 200 Amp rated bus bar including earth & neutral link, complete fixing acessoreies all as specified and directed
S&F in repair VTPN MCCB 160A DB 6 way, doble door, IP 54 protection, with 200 Amp rated bus bar including earth & neutral link, complete fixing acessoreies all as specified and directed
S&F in repair VTPN MCCB 125A DB 6 way, doble door, IP 54 protection, with 200 Amp rated bus bar including earth & neutral link, complete fixing acessoreies all as specified and directed.
S&F sheet metal enclosures MCB DB 4 way TPN, Vertical type , double door, IP54 Protection with 200 Amp rated bus bar including earth & neutral link, complete fixing acessoreies all as specified and directed.
S&F in repair Miniature circuit breaker (MCBs) Single Pole, 240 Volts, 10KA, 6 to 32 Amps, 'C' curve complete all as specified and directed.
S&F as in repair MCB SP 63 Amps 10KA ‘C’ series 240 volts complete all as specified and as directed.
S&F as in repair MCB SPN 40 Amps 10KA ‘C’ series 240 volts complete all as specified and as directed.
S&F in repair MCCB 160A, 36 KA, 415 Volts complete all as specified and directed.
S&F in repair MCCB 125A, 36 KA, 415 Volts complete all as specified and directed.
S&F Miniature circuit breaker (MCBs) Triple Pole and Neutral, 415 Volts, 63A, breaking capacity 'C' curve complete all as specified and directed.
M&L two single core PVC insulated unsheathed cable 10 sqmm (Nominal aera) with multistranded copper conductor cable, 1100 volts grade, drawn through existing PVC concealled conduit with accessories and continious earth wire of single core PVC insulated, unsheathed cable 10 sqmm (Nominal area) with ultistranded copper conductor (green), 1100 volts grade for sub main wiring and making good disturbed surfaces complete all as specified and as directed. Note:- (i) Two run of wiring cable, one run of earth wire shall be measured as one unit.
M&L sub main wiring with twosingle core PVC insulated unsheathed cable 6.00 Sqmm (Nominal area) with multistranded FRLS copper conductor cable, 1100 volts grade drawn through and including PVC casing & capping of size not less than 25mm with accessories and earth continuity conductor of single core PVC insulated, unsheathed cable 6.0 Sqmm (Nominal area) with multistranded copper conductor, 1100 volts grade and making good disturbed surfaces complete all as specified and as directed. Note:- (i) Two run of wiring cable, one run of earth wire and one run of PVC casing & capping shall be measured as one unit.
M&L two single core PVC insulated unsheathed cable 6.0 sqmm (Nominal aera) two run with multistranded copper conductor cable, 1100 volts grade, drawn through existing PVC concealled conduit with accessories and continious earth wire of single core PVC insulated, unsheathed cable 6.00 sqmm (Nominal area) with ultistranded copper conductor (green)one run 1100 volts grade for sub main wiring and making good disturbed surfaces complete all as specified and as directed. Note:- (i) Two run of wiring cable, one run of earth wire shall be measured as one unit.
S&F in repair sheet metal enclosure SPN with two pin earth plug and socket complete with one single pole MCB 20 Amps, 10KA, 240 Volts incl removing the existing unserviceable metal plug socket complete all as directed.
S&F as in repairs Power Units Complete with 4 Module plate, 25A starter, 25A Socket, 25A Plug including metal flush box all as directed.
M & L for earthing complete with galvanized steel earth plate electrode 600mmx600mmx6mm thick buried directly in gournd (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanized 4 mm dia earth wire as earthing lead upto 7.5 mtrs from testing point fixed by means of steel bolts, nuts, check nuts and washer, of galvanized earth wire protected by 25mm bore medium grade galvanised iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore light grade galvanised iron, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (Compacted thickness) all around earth electrode with concrete earth pit in PCC (1:3:6) type C-1 50mm thick precast RCC M-20 nominal mix cover slab of size 450mm x 450mm reinforced with 8mm dia TMT bar 10 cm C/C and suitable handle of 10mm dia round bar including necessary execavation, earth work in soft / loose soil and deposited soil to a distance n.exc 50 M and necessary testing complete all as shown in electrical plate No. 3 of MES shedule of SSR Part-I complete all as specified and as directed.
S&F GI wire dia 4 mm size complete all as specified and as directed.
M/S Annu Electronics
Singhs Construction
SHRI D. C. BISWAS
M/S Kangkans
M/S R.B. Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .