Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC VIKRAM COACHING GALI SUDAMA NAGARI MADI NATH BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹25.0 L | L1 | Accepted-AOC ok |
| 2 | L2₹25.5 L+₹44,225 (1.77%)Rejected-AOC WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | ₹25.5 L+₹44,225 (1.77%) | L2 | Rejected-AOC ok |
| 3 | L3₹28.9 L+₹3.9 L (15.7%)Rejected-AOC | ₹28.9 L+₹3.9 L (15.7%) | L3 | Rejected-AOC ok |
| 4 | L4₹30.8 L+₹5.8 L (23.2%)Rejected-AOC | ₹30.8 L+₹5.8 L (23.2%) | L4 | Rejected-AOC ok |
| 5 | L5₹31.8 L+₹6.8 L (27.1%)Rejected-AOC BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹31.8 L+₹6.8 L (27.1%) | L5 | Rejected-AOC ok |
Tender Value
₹36 L
EMD Value
₹70,000
Closing Date
11 Apr 2022, 6:00 pmClosed
GE WEST BAREILLY
GE West Bareilly
REPAIRS/REWINDING OF CEILING FAN, EXHAUST FAN AND OTHER CONNECTED WORK OF OTM / MD ACCN OF BAREILLY CANTT UNDER GE (WEST) BAREILLY
2022_MES_513772_1
8028/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION O
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹70,000
Yes
14 May 2022
15 Mar 2022
13 Apr 2022
15 Mar 2022
11 Apr 2022
28 Mar 2022
15 Mar 2022 - 27 Mar 2022
Amount
Taking down ceiling fans 1200/1400 mm sweep & removing/cleaning of dust properly, oiling and greasing of bearing including re-fixing and connecting up with all requisite accessories complete all as specified and directed.
Re-winding of ceiling fan burnt motor of 1200/1400 mm sweep including internally and externally cleaning of fans and removing the burnt coil and re-winding of fans by super enameled copper wire of appropriate size and re-assembling the fans and connecting with flexible copper wire of one mtr length and testing after repair complete all as specified and directed.
Taking down exhaust fan of 450/300 mm sweep and removing/cleaning the dust properly including oiling and greasing complete all as directed.
Re-winding of exhaust fan burnt motor of 450/300 mm sweep with appropriate size of super enameled copper wire, Make: ATLAS or equivalent including re-assembling the fans and connecting with flexible copper wire of one mtr length complete all as directed.
Supply and Fixing in repairs bush of ceiling fans of any size complete all as directed.
Supply and Fixing in repairs insulating rubber real including Supply and replacing nuts, bolts with washers complete all as specified and directed
Supply and Fixing in repairs shaft of fans (as per sample) of suitable size complete all as specified and directed
Supply and Fixing in repairs of fan pins of suitable size for various type of fans / ceiling fans complete all as specified and directed.
Supply and Fixing in repairs flexible wire 23/0.0076 PVC insulated copper conductor twin core complete all as specified and directed. Make- Havells/Anchor/Finolex/Kalinga
Supply and Fixing in repairs fan conopy, suitable for various type ceiling fan all as per sample and directed.
Supply and fixing PVC exhaust fan 250/300 mm with louvers with complete fixing and connection all as directed and specified by Engr-in-Charge.
Suply and fixing louvers in repairs of PVC for exhaust fan of size 250/300/450 mm
Suply and fixing louvers in repairs of steel for exhaust fan of size 250/300/450 mm
Cutting of wall for fixing exhaust fan of PVC/Iron fan of size 250/300/450 mm including fixing requirment at site by grouting fully threaded bolt and nuts including connection complete with one meter copper wire and repair complete, painting of wall all as directed & specified by Engr-in-Charge.
Taking down carefully existing Aluminum/Copper point wiring (light/ Fan / Socket/Power Point) complete fittings etc. making good to disturbed surface of wall/Floor etc to match the existing surface/ finishes all as directed.
M&L for concealed point wiring for one light/ fan/ bell point controlled by one switch with1.5 Sqmm (Nominal area) PVC insulated, unsheathed, stranded copper, conductor cable FRLS (1100Volts grade) drawn in and including PVC conduits of 20 mm dia with all fittings and accessories alongwith PVC insulated cable with copper conductor of size 1.5 Sqmm as earth continuity conductor including fixing of 1. 2mm thick MS sunk terminal box duly flushed to wall with 3mm thick plastic laminated/ebonite sheet cover fixed with screws,cap and washers incl. making good the disturbed surfaces complete. Make of Cable: Polycab/Finolex/Havells,ISI Marked
All as per item no.15 here in before but for socket outlet 3/5 pin 5 amp. on the same board.
All as per per item No 15 here-in-before but for one light point controlled by two Nos of 2 way switches complete all as specified and directed. MAKE OF CABLES : PLAZA/HAVELLS/FINOLEX (ISI MARKED)
All as per item No 15 here-in-before but for switch socket combination 5 Amps 3/5 Pin point on independent board MAKE OF CABLES : Polycab/Finolex/Havells,ISI Marked
M&L for concealed point wiring with 2.5 Sqmm (Nominal area) PVC insulated,unsheathed, multi stranded Copper conductor cable drawn in and including PVC rigid PVC conduit 25mm or higher size with all its fittngs and accessories for one 3 pin/6 pin 15 Amps socket out let point independent alongwith PVC insulated cable with solid copper conductor 1.5 Sqmm (nominal area) continuous earth wire, and connected to earth dolly including fixing of 1.20mm sunk pressed steel terminal box suitably flushed to wall with 3mm thick Hylum sheet cover fixed with screws & cup washers incl. making good complete. MAKE OF CABLES : Polycab/Finolex/Havells,ISI Marked
Supply and Fixing in repairs Modular switches 1 way, 6 A, 1 module
Supply and Fixing in repairs Modular switches 1 way, 16 A, 1 module
Supply and Fixing in repairs socket outlet ,3/5 pin 5 amp flush type
Supply and Fixing in repairs socket outlet 2 in one, 3/5 pin 5 and 15 Amp flush type
Supply and Fixing in repairs Modular sockets 6 A, 2/3 pin combined 2 module
Supply and Fixing in repairs Modular sockets 6 A/16 A, 2/3 pin combined 2 module
Supply and Fixing in repairs lamp holder PVC Angular/ pendent/ bakelite.
Supply and Fixing in repairs buzzer, capton ding dong,AC,230V,Single Pole
Supply and Fixing in repairs Modular fan regulators step type, 120 W, 2 module
Supply and Fixing in repairs fan regulator resistance/electronic step type single phase 230 volt.
Supply and Fixing in repairs Condenser 2.5 Mfd make universal/Usha /Bajaj.
Supply and Fixing in repairs Condenser 3.5 Mfd make universal/Usha /Bajaj.
Supply and Fixing in repairs MCB SPN 20 to 32 Amps 240 volts.10kA Make:- Indo Asiana/Legrand/ Havells
Supply and Fixing in repairs MCB SP 6 to 32 Amps 240 volts, 10 kA. Make:- Legrand/ Havells/Standard
Supply and Fixing in repairs MCB TPN 63 Amps,415V,10kA
Supply and Fixing in repairs MCCB TPN 100 Amps, 415V, 16kA ,Thermal Magnetic Release
Taking down unserviceable existing sub main wiring of aluminium conductor stranded cable upto and including of any size single core including earth wire from existing conduit or wooden battens including taking out unserviceable wooden gutties etc, matching with the existing surfaces complete all as specified and as directed.
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of copper conductor of size 2.5 Sqmm connected to common earth dolly and drawing into rigid PVC conduit of 25mm dia medium grade size incl. making good the disturbed surface complete.(Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit). MAKE OF CABLES : Polycab/Finolex/Havells,ISI Marked
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size incl. making good the disturbed surfaces complete.(Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit). MAKE OF CABLES : Polycab/Finolex/Havells,ISI Marked
S&F in replacement sheet metal enclosure DB's 415 Volts, IP-42, vertical suitable for mounting MCCB's, TPN, 4 way with 200 Amps rated copper bus bar complete all as directed by Engineer-in-charge.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 4 ways Make Make Legrand or equivalent make of HPL Moeller/L&T Hagger/Havells complete all as specified and directed.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 8 ways Make Make Legrand or equivalent make of HPL Moeller/L&T Hagger/Havells complete all as specified and directed.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 12 ways Make Make Legrand or equivalent make of HPL Moeller/L&T Hagger/Havells complete all as specified and directed.
Supply and Fixing in repairs 4 Pin CFL lamp 36Watt , Make : Bajaj/Havells/Philips
S & F in repairs 2 Pin CFL 18 W lamp, Led bulb of thread type, focused light Make : Bajaj/Havells/Philips
S&F LED retrofit tube with PVC extruded battern 20watt 4 feet White colour including dismentiling and taking down any type of FTL/LED complete all as specified and directed.
S & F retrofit LED tube rod 18/20 W, 4 feet for fixing in existing LED/FTL light fitting make C & S / Philips.
S & F Side holder suitable for existing LED/FTL fittings as per site requirement.
S&F in repairs building scurity light led type 20 watt including GI pipe bracket 32 mm dia with clamp including complte connection wih copper wire all as directed and specified by Engr-in-Charge.
S&F in repairs 9W LED bulb of make of B22/B27 type.
S&F LED mirror light fixture 9W LED 6000K 50Hz 240V.
S&F LED fountain light of min. 10 watt as specified and directed by Engg. In charge.
S&F machine screw for fitting hylem sheet.
S&F 2'x 2' LED recess/ surface mounted fitting 36 Watt, 230V, with integrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Model - BCTBLS/R 36 ZT WH of Make- BAJAJ or eqvlt in Philips/ Havells.
S&F 1'x 1' LED recess/ surface mounted fitting upto18 Watt, 230V, with integrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Model - BCTBLS/R 36 ZT WH of Make- BAJAJ or eqvlt in Philips/ Havells.
S&F recess/surface mounted LED downlighter of round/square upto 12w concealed /surface mounted with removable driver complete all as specifid and directed.
S&F in replacement of PVC non metallic casing caping of 25mm size with accessories such as saddle etc.
Supply and fixing 1.5 sqmm copper wire in replacement of old wire.
Supply and fixing 2.5 sqmm copper wire in replacement of old wire.
Supply and fixing 4.0 sqmm copper wire in replacement of old wire.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVCinsulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm nominal cross section in service connections.
Supply and fixing LED post top lantern with die cast aluminium spigot, spun aluminium powder coated top cover, Alumnium PDC heat sink, opal PC diffuser and clear acrylic of Havells,c&s, phillips.
S&F repairs paino switch flush type 5 Amps single pole one way complete all as specified and directed.
S&F repairs paino switch flush type 15 Amps single pole one way complete all as specified and directed.
Notes :- . (i) For Serial No 01 to 10: The contractor has to complete the work assigned for said items with in 10 days from issue of fan through gate pass failing in which recovery at the rate of Rs. 25 per day per complaint shall be deduct. (ii) For Serial No 11 to 64 : The Contractor has to complete the work assigned for above items with in 72 hours failing in which recovery at the rate 25 Rs. Per day per complaint (iii) The contractor has to maintain a separate complaint slip book and complaint register for attending complaint. The contractor rep have to collect daily complaint slip from the E/M complaint cell on the same day at 09 AM and get them signed from user after completing the job and submit to E/M complaint cell.
N S ELECTRICALS
Shri Siddhi Vinayak Constructions
Mangalam Trades
prabhave traders
Goel Enterprises
BK CONSTRUCTION
R.S ENGINEERING TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .