Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 CrAccepted-AOC | ₹6.0 Cr | L1 | Accepted-AOC Ad.BII/5517/2021/UOK dtd 20.10.2021 |
| 2 | L2₹7.2 Cr+₹1.2 Cr (20.8%)Rejected-Finance | ₹7.2 Cr+₹1.2 Cr (20.8%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical 1 ITI BHAWAN OLD MADRAS ROAD DOORVANI NAGAR BENGALURU KARNATAKA 560016 | BENGALURU URBAN | KARNATAKA | 560016 | - | - | Rejected-Technical Pre qualification conditions not fulfilled |
Tender Value
₹8.7 Cr
EMD Value
₹2 L
Closing Date
10 Sept 2021, 3:30 pmClosed
University Engineer
Engineering Unit, Kariavattom
CIVIL ,ELECTRICAL AND ELECTRONIC WORKS IN CONNECTION WITH THE SETTING UP OF MULTIMEDIA THEATRE CLASS ROOMS AND MULTIMEDIA CLASS ROOMS IN UNIVERSITY TEACHING DEPARTMENTS ( RETENDER)
2021_KU_436123_1
UE/DB/ (e-GP) E8/2021-2022
Open Tender
Miscellaneous Works
Supply and Service
120 days
Kariavattom TVPM
Please refer Prequalification Tender documents
6 documents required · 6 mandatory
₹10,000
₹2 L
SH campus Palayam
22 Oct 2021
25 Aug 2021
13 Sept 2021
25 Aug 2021
10 Sept 2021
25 Aug 2021
25 Aug 2021 - 10 Sept 2021
3 Sept 2021
Amount
General maintenance, Structural repair and anti termite treatment works
od276473/2020_2021 : Providing and fixing scaffolding system using props, span and wooden logs to the interior side of building/structure, upto 5 height, abovefloorlevel, including additional rows of scaffolding in stepped manner as per requirement of site, joint with cup & lock system with M.S. Tubes, M.S. tube chakkus, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition including chjarges for removal of teh same after the repair works completed for execution of work of cleaning plastering or applying chemical etc. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-Charge. Note: - ( 1) The plan area of the scaffolding shall be measured for payment purpose, (2) The payment will be made once only for execution of all items of such works.
26.28.3 : Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness
26.28.2 : Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge50mm average thickness
15.56 : Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
26.29.2 : Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars above 12 mm diameter
26.31.1 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2kg cement per sqm of surface area mixed with specified proportion of approvedpolymer
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
26.32.2 : Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).25 mm average thickness in 2 layers.
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
od276485/2020_2021 : Applying Polymer based water proofing compound over the roof top after cleaning the surface thoroughly and removing all loose and dust particles, mixing the approved polymer based compound with white cement @ 2kg white cement per 1 liter water proofing compound or as per manufacturers specification, mixing thoroughly, and applying to the roof top surface two or three coat after suggestive curing for each coat and applying in transverse direction to each coat etc as per deparatmental direction
14.17 : Raking out joints in lime or cement mortar and preparing the surface for re- pointing or re plastering, including disposal of rubbish to the dumping ground within 50 metres lead.
14.18.1 : Flush pointing with cement mortar 1:3 ( 1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska:With F.P.S. brick tiles
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
15.41 : Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
15.28.1 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
6.4.1 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand)
15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
4.1.4 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
4.3.2 : Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
od276486/2020_2021 : Supplying chemical emulsion in sealed containers including delivery as specified.<br>Imidacloprid emulsifiable concentrate of 30.5% (Tata Termex or equivalent)
od276487/2020_2021 : Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):<br>Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor:<br>With Imidacloprid 30.5 % with 0.075% concentration (2.10 ml per 1 litre of water)
od276488/2020_2021 : Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):<br>Along the external wall below concrete or masonry apron using chemical emulsion @2.25 litres per linear metre including drilling and plugging holes etc:<br>With Imidacloprid E.C.30.5% with 0.075% concentration(2.10 ml for 1 litre of water)
od276489/2020_2021 : Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):<br>Treatment at points of contact of wood work by chemical emulsion Imidacloprid (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same
od276490/2020_2021 : Dismantling and removing old vinyl sheet flooring without damages to the floor and disposal of the debris within a distance of 150 m out side the area cleared
od276491/2020_2021 : Dismantling and removing chairs from floor without any damage to the mounting assembly and stacking materials within a distance of 50 m as per departmental direction
od276492/2020_2021 : Repairing the steel windows including replacing teh corroded frames with new steel frames of appropriate sections, welding jointing grinding and finshing etc compleet as per departmental direction
14.5.1 : Renewing glass panes, with putty and nails wherever necessary including racking out the old putty :Float glass panes of thickness 4 mm
14.6.2 : Renewing glass panes, with wooden fillets wherever necessary:Float glass panes of thickness 5.5 mm
Floor upgradation
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
od276476/2020_2021 : Providing and fixing 18 mm thick Marine plywood conformingto IS : 710 (Century or equivalent make for floor platform fixed to the steel frame work already provided for vertical and horizontal surfaces with screws, bolts, nuts wherever necessary as per departmental direction
13.50.1 : Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work (hard and soft wood)
od276482/2020_2021 : Providing and fixing carpet sheets of approved colour, synthetic nylon/wool as per design minimum 3 mm thickness to be fixed over the wooden floor using suitable adhesive in vertical as well as horizontal surfaces as per departmental direction. (Approval of sample is necessary before the execution of the work)
11.41.4 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1000x1000 mm
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
Wall finish and Acoustic traetment
od276796/2020_2021 : Providing and fixing teak wood wall paneling ( second class teak wood) with 12 mm thick teak wood planks 15 cm wide fixed horizontally to wall using steel screws, PVC fissure plug etc. The planks should be fixed in such a way to provide 6mm groove in between each planks by cutting 6mm grooves on one side of the planks using mechanical means, etc. complete as per departmental direction
13.69.1 : Polishing on wood work with ready mixed wax polish of approved brand and manufacture:New work
od276474/2020_2021 : Providing and fixing acoustic wall paneling System using 12.50 m thick or nearest approved size perforated gypsum board of approved pattern and finish fixed to wall using an grid system MS power pressed steel channels 80x26x0.50 mm size fixed to the wall with stainless steel screws and connecting clips wherever necessary at 60 cm c/c vertically and horizontally and filling the gap in between wall and panel board using suitable sound absorbent material of appropriate thickness, finishing joints with putty as per direction of departmental authorities
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
13.84.2 : Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
Aluminium Work and Window Curtain
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
od276477/2020_2021 : Providing and fixing 4 mm thick thick aluminium composite panel, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.<br>
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
21.12.2 : Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Powder coated minimum thickness 50 micron aluminium tubular handle bar
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
9.97.1 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper
od276484/2020_2021 : Providing and fixing superior quality roller blinds with all fittings
Furniture
od276469/2020_2021 : Supply and Installation of Metal Storage With Metal Top shall have an overall size of 900mm(W)x450mm(D)x1167.5mm(H) . The construction shall be rigid knock down construction and Material used shall be prime quality CRCA steel - panels from 0.6 mm thick & front frame . Shelf shall be 0.8 mm thick .Configuration (Door) shall be full height steel hinged door . Locking shall be Plastic Recessed Handle cum Cam lock with 3 way locking mechanism with shooting bolt arrangement . Height wise adjustable shelf mounting , Uniformly distributed load capacity per each full shelf shall be 80 Kg maximum . 2 Nos. of adjustable full shelves . The top shall be metal plus leveler shall be screw type with hex plastic base and Epoxy Powder coated finish to the thickness of 50 microns .(Approval of sample is necessary)
od276472/2020_2021 : Supply and Installation of Table of size 2700mm L x 600mm w x 750 height (4 seater) Metal Modesty. The Work surface shall be made of 25mm thick. Pre-laminated particle board with PVC Edge. Under structure shall be MS powder coated. Metal Perforated Modesty panel to be considered. Product to be certified by IAQ, Greenpro, Griha and BIFMA LEVEL 3 certification as per the ANSI/ BIFMA e3 Furniture Sustainability standard from SCS Global services. (Approval of drawing and sample is necessary)
od319315/2020_2021 : Supply and Installation of Table of size 2100mm L x 600mm w x 750 height (3seater) Metal Modesty. The Work surface shall be made of 25mm thick. Pre-laminated particle board with PVC Edge. Under structure shall be MS powder coated. Metal Perforated Modesty panel to be considered. Product to be certified by IAQ, Greenpro, Griha and BIFMA LEVEL 3 certification as per the ANSI/ BIFMA e3 Furniture Sustainability standard from SCS Global services. (Approval of drawing and sample is necessary)
od276475/2020_2021 : Supply and Installation of Chair. The seat shall be made from 1.2 ±0.1cm. thick. hot pressed plywood measured as per QA method described in OCP-QLTA-P14-18 and back shall be injection moulded from black Co-polymer Polypropylene upholstered with fabric and moulded Polyurethane foam together with seat and back covers. The back foam shall be designed with contoured lumbar support for extra comfort. The dimensions of seat shall be 50(W) x 50 cm.(D) and of back shall be 45cm(W) x 50cm.(H). The armrests shall be made of black integral skin Polyurethane with 50-70 Shore 'A' Hardness and reinforced with M.S. The P.U. armrests shall be then fixed to black powder-coated ( DFT 40-60 microns ) armrest brackets made of of 0.5 ± 0.05 cm. thick. HR steel and shall be fitted with claddings made of injection moulded Polypropylene. The seat and back covers shall be injection moulded in black Co-polymer Polypropylene. The HR polyurethane foam shall be moulded with density = 45 +/-2 kg/m3 and hardness load 16 ± 2 kgf as per IS:7888 for 25% compression. The fixed type mechanism shall be without back tilt. The tubular frame shall be made up of dia 2.54 ±0.03cm. x 0.2 ±0.016cm.thk. M.S.E.R.W. tube and black powder coated (DFT 40-60 microns). The overall dimensions of chair shall be Seat Height -50.0cm, Height -88.5cm or nearest approved size Width & Depth of Chair as measured from pedestal - Width-56.0 cm and Depth-54.0 cm.(Approval of sample is necessary)
Other petty works
od276470/2020_2021 : Providing signage of size 100cmx100 size in aluminium composite panel, of approved colour, cutting and sticking silver colour letters of size 7.5 cm height and 5 cm width, fixing in position using stainless steel screws etc complete
od276471/2020_2021 : Providing signage of size 30x15 cm size in aluminium composite panel, of approved colour, cutting and sticking silver colour letters of size 7.5 cm height and 5 cm width, fixing in position using stainless steel screws etc complete
od276480/2020_2021 : Refixing the departmental theatre chairs in position including renewing bolt and nut etc as per departmental direction
FALSE CEILING
12.45.3 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
Description of Work / Item(s)
Amount
ELECTRIFICATION
1.17.1 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.11 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.20 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.31 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
90.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.6.10.2 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm
90.6.10.1 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required 20 mm
90.6.10.3 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required 32 mm
od271275/2020_2021 : Supply and providing 25 mm corrugated PVC flexible conduit as required at site.
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.10.3.15 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 32A DP switch with indicator
90.10.3.33 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 25A 3pin Shuttered socket
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
od271276/2020_2021 : Supplying and fixing 4-pole sheet steel enclosure conforming to IEC: 61439-3 on surface / in recess and suitable for mounting MCB / Isolator complete with connections, testing, commissioning etc. as required.
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP42/43)
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm withfactory made clamp
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.43 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.3.12 : Conveyance and fixing charges of recess mounting down light fittings of all types complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required.
od271277/2020_2021 : Supply and testing the following ratings of recess mounting round LED down light fittings of all types complete with all accessories including driver in the existing opening of false ceiling, giving connections with required length of 16/0.20 mm 3-core PVC insulated and PVC sheathed copper conductor round flexible wire of grade 1.1 kV conforming to relevant ISS or extending the original wiring and giving connections as required.<br>18W recess mounting round LED down light suitable for continuous operation with THD <10%, power factor >0.98 and RoHS compliant. (Make- Crompton-LSCRM-18W-CDL, Havells, Philips or Wipro)
90.4.6 : Conveyance, installation, testing and commissioning of wall mounting fans of all types using mounting brackets supplied along with the fan.
od271278/2020_2021 : Supplying of 400 mm sweep oscillating type wall mounting fan having 3-speed control, oscillation control at bottom and suitable for operation on single phase 230 V, 50 Hz AC supply complete with continuous duty motor, chrome plated front and rear guards and all other accessories as required. (Make- Crompton, Havells, Orient or Almonard)
od271279/2020_2021 : Dismantling of existing pre-wired, fluorescent/LED fitting/ of all types, complete with all accessories including tube, ball and socket arrangement, 2 nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 60 cm length etc and conveying the same to the section store without any damage as required.
od271280/2020_2021 : Dismantling of existing ceiling fan of all types along with all accessories and conveying the same to the section store without any damage as required.
od271281/2020_2021 : Supply and providing ISI marked 4 Kg dry chemical powder (ABC) fire extinguisher conforming to IS: 15683 along with hose and clamps including fixing it to wall as required. (Make- Ceasefire, Safex, Eco fire or Safe pro)
od271284/2020_2021 : Supply, laying and providing earth connection from earth electrode with 8 SWG bare copper earthing conductor laid 0.50 metre below ground level in 20 mm dia. PVC conduit as protective covering to earth leads including excavating trench of suitable size, giving connection / termination with copper thimble, refilling the trench etc as required (in ordinary soil).
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)
od271285/2020_2021 : Supply, conveyance, installation, testing and commissioning of factory made 8-way load bank (IP 43) conforming to IS: 8623 / IEC 61439-2 with double cover frame, wall mounting type with screwed metal door made out of 16 SWG special grade CRCA powder coated sheet steel and with insulated vertical copper bus bar system, neutral link, earth bus, cable alleys (sides and bottom), metering module, corner box, blanking plates etc and with provision for fixing MCCB as incomer and suitable rating TP MCCBs as outgoings (excluding MCCBs), including giving connections, making good the damages, colour washing etc as required. (Make: L&T-SMDB-TN250D, Havells or Schneider)
od271542/2020_2021 : Providing and fixing 250A, 36kA (Ics=100%Icu), 4-pole, current limiting type MCCB conforming to IS: 13947 and suitable for 440 V, 50 Hz, AC supply and having microprocessor based release with overload setting of 50 - 100% having adjustable OL and SC protection in the existing cubicle panel board including drilling holes in cubicle panel, making connections, testing etc. as required.
od271286/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.<br>63 Amp, 25 KA, TP MCCB
od271287/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.<br>80 Amp, 25 KA, TP MCCB
od271288/2020_2021 : Supply and intallation of 4 sqmm to 16 sqmm. 60 mm long x 12 mm wide x 1 mm thick Copper earthing clips for single compression glands
2.1.1 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
2.1.2 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
od271457/2020_2021 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed ISI marked rigid PVC conduit of minimum size 20 mm conforming to IS: 9537 Part-3 1983 with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.<br>Group C
od271458/2020_2021 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed ISI marked rigid PVC conduit of minimum size 20 mm conforming to IS: 9537 Part-3 1983 with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.<br>Group B
od271459/2020_2021 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed ISI marked rigid PVC conduit of minimum size 20 mm conforming to IS: 9537 Part-3 1983 with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.<br>Group A
od271460/2020_2021 : Supply and wiring points according to IS: 732-1989 using ISI marked rigid PVC conduit of minimum size 20 mm conforming to IS: 9537 Part-3 1983 and with suitable size specials conforming to IS: 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cms or concealed suitably and with ISI marked 1.50 sq. mm PVC insulated stranded single core FRLS copper conductor cable of 650 / 1100 V grade, including providing switch board main and continuous earthing with ISI marked 1.50 sq. mm PVC insulated stranded single core FRLS copper conductor cable 650 / 1100 V grade, required quantity of copper earth socket, brass bolt and nut, crimping / soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories)<br>Combined plug point with 6A, 5-pin plug socket controlled by 6A switch in the same switch board as that of light points - Short point.
1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.9 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
od277170/2020_2021 : Supply of the following types of light fittings made of CRCA sheet with 0.50 mm thickness complete with all accessories<br>1x20 W LED box type tube fittings with industrial box type luminaire suitable for single T8 LED tube (Make- Crompton-IGP161LT8-16 , Philips, Havells or Wipro)
od277171/2020_2021 : Supplying linear LED T8 tube with extruded aluminium body, PC diffuser and inbuilt driver having double sided connection suitable for continuous operation with THD <10%, power factor >0.98 and RoHS compliant. (Make- Crompton-LTT8-20, Philips, Havells or Wipro)
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
AIR CONDITIONING
od271264/2020_2021 : Suppy, installation, testing and commissioning of 4.0 TR (48000 BTU/hr) cassette type air conditioning system with eco-friendly R410A refrigerant to maintain zero ozone depletion potential (ODP) based on DC inverter technology, dual rotary compressor, magnetic flux vector sine wave drive, DC fan motor, pulse amplitude modulation etc. with long life filter, filter check signal, horizontal auto vane, auto fan speed mode, ON/OFF operation timer, auto restart facilities etc. suitable for mounting on low and high ceilings. The unit shall be complete with drain pump, pump down switch, flare connection etc. and with maintenance features like self diagnostic function and failure recall function. The noise level of the IDU shall not exceed 44 dB(A) and 56 dB(A) for ODU. The unit shall be 5-star rated as per BEE. The EER shall not be less than 2.34 and ISEER shall not be less than 3.54. This shall be supplied along with wireless remote controller. Accepted makes with model details:- 1) Mitsubishi Electric (IDU: PLY-SP48EA, ODU: PUY-SP48YKA2, Panel: PLP-6ELM, Wireless remote controller: PAR-SL 100A-E), 2) Toshiba Electric (IDU: RAV-SE1251UP-IN1+RAV-TE1251AP-IN, ODU: RBC-U31PGXP(W)-IN1), 3) Panasonic (IDU: S48PU2H5, ODU: U48PS2Y5, Panel: CZKPU3H, Wireless remote controller: CZRL013UH), 4) Samsung (Model: AC140NN4DKC/TL, White, WindFree), 5) Voltas (Model: CAS48VHCZAAR410A).
od271265/2020_2021 : Supply, installation, testing and commissioning of 1.5-Ton, 5-star rated, inverter type, wall mounting, high energy efficient, split air conditioner unit (IDU), fitted with hermetically sealed rotary compressor (ODU) suitable for eco-friendly and energy efficient refrigerant R-32A conforming to IS: 1391 Part-2 1992 (with latest amendments except power consumption norms) suitable for operation on 230 V, 50 Hz AC supply and capable of performing functions such as cooling, dehumidifying, air circulating, filtering etc and having features of long distance piping flexibility, wide angle air flow, IDU noise level < 43 dB (A) and ODU noise level < 56 dB (A) as required. The condensing and evaporating coils should be made of soft drawn bright annealed copper tubes of suitable sizes (100% copper) and a standard length of upto 3 metres should be supplied with the AC unit and the copper pipes should be properly insulated with 10 mm thick closed cell Class '0' elastomeric nitrile rubberised foam sleeve insulation. A standard length of upto 3 metres of suitable size ISI marked round flexible copper control cable for electrically connecting IDU and ODU of AC unit should be supplied with the AC unit along with microprocessor based wireless remote controller with required number of suitable batteries as required. Total 4 numbers of comprehensive free services should be provided for the AC unit (IDU & ODU) for the first one year, applicable from the date of commissioning. One year replacement warranty should be provided for the entire AC unit (IDU & ODU) along with one year exclusive warranty for the PCB and nine years exclusive warranty for the compressor. Make- Panasonic, Voltas(SAC 185VJZJ), Carrier, Mitsubishi, Blue Star(IC518DATU/YATU) or Daikin(FTKM50).
od271266/2020_2021 : Supply, installation, testing and commissioning of 2-Ton, 5-star rated, inverter type, wall mounting, high energy efficient, split air conditioner unit (IDU), fitted with hermetically sealed rotary compressor (ODU) suitable for eco-friendly and energy efficient refrigerant R-32A conforming to IS: 1391 Part-2 1992 (with latest amendments except power consumption norms) suitable for operation on 230 V, 50 Hz AC supply and capable of performing functions such as cooling, dehumidifying, air circulating, filtering etc and having features of long distance piping flexibility, wide angle air flow, IDU noise level < 43 dB (A) and ODU noise level < 56 dB (A) as required. The condensing and evaporating coils should be made of soft drawn bright annealed copper tubes of suitable sizes (100% copper) and a standard length of upto 3 metres should be supplied with the AC unit and the copper pipes should be properly insulated with 10 mm thick closed cell Class '0' elastomeric nitrile rubberised foam sleeve insulation. A standard length of upto 3 metres of suitable size ISI marked round flexible copper control cable for electrically connecting IDU and ODU of AC unit should be supplied with the AC unit along with microprocessor based wireless remote controller with required number of suitable batteries as required. Total 4 numbers of comprehensive free services should be provided for the AC unit (IDU & ODU) for the first one year, applicable from the date of commissioning. One year replacement warranty should be provided for the entire AC unit (IDU & ODU) along with one year exclusive warranty for the PCB and nine years exclusive warranty for the compressor. Make- Panasonic, Voltas(SAC 245VDZV), Carrier, Mitsubishi, Blue Star(IC524DBTU) or Daikin(FTKG60).
od271267/2020_2021 : Supply and drawing extra length of following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit for electrically connecting IDU and ODU of the AC unit as required including giving necessary connections of the following sizes.<br>4 core 2.50 sq mm
od271268/2020_2021 : Supply and providing extra length of superior quality soft drawn bright annealed copper refrigerant pipes (suction and discharge) of suitable sizes for extending the refrigerant piping between ODU and IDU of the AC unit and properly insulating the copper pipes with 10 mm thick closed cell Class O elastomeric nitrile rubberised foam sleeve insulation and the joints sealed with black cotton tape with proper mechanical fixing including brazing, pressure check, leak testing etc as required.
od271269/2020_2021 : Supply and providing 25 mm PVC pipe on wall as drain pipe for AC unit with all required accessories including cutting and making good the walls, colour washing etc as required.
od271270/2020_2021 : Supply and providing 75 mm PVC pipe on wall with all required accessories for covering drain pipe including cutting and making good the walls, colour washing etc as required.
od271272/2020_2021 : Supply, installation, testing and commissioning of wall mounting type 5 kVA voltage stabilizer with input voltage range of 170 V - 270 V and having features of high power efficiency, intelligent time delay system, Low & High voltage cut-off protection, built-in thermal overload protection, LED indications etc suitable for single phase 2-Ton air conditioner unit with three years warranty and three months replacement guarantee. (Make: V-Guard, V-Stab, Pioneer, Crompton or Microtek)
od271273/2020_2021 : Supply, installation, testing and commissioning of wall mounting type 4 kVA voltage stabilizer with input voltage range of 170 V - 270 V and having features of high power efficiency, intelligent time delay system, Low & High voltage cut-off protection, built-in thermal overload protection, LED indications etc suitable for single phase 1-Ton / 1.5-Ton air conditioner unit with three years warranty and three months replacement guarantee. (Make: V-Guard, V-Stab, Pioneer, Crompton or Microtek)
od271274/2020_2021 : Supply and fixing good quality of factory made powder coated MS frames (condensor stand) with all required accessories including suitable size anchor bolts, anti vibration pads etc for mounting the out door unit of AC in position as required.
Description of Work / Item(s)
For smart class rooms
Audio equipments (of make Ahuja, Studio master, Bheringer, AKG, Soundcraft,Shure,Audio technical, Bayerdynamic)
Dual channel wireless receiver with hand held mic ( 1 no) and lapel mic (1 no) with body pack transmitters. No. of channels 2 Input:1Xhandheld mic,1X lapel mic Frequency response:60Hz-15000Hz
Head band mic Uni directional suitable for above Wireless receiver and body pack transmitters
6 Channel Audio mixer with AEC, AGC and NR. Number of inputs: 2 Mono mic/Line+2Stereo DelayEFX on board with individual channel control +2 o/p with control Rotary contron knob per channel Head phone output with control Frequency response: 20Hz-20KHz Power supply: Ac 240V/50Hz
100 W portable self powered active speakers Power:100W Frequency Response:55-16000Hz Input: XLR and Jack Additional: Wallmount accessories Line out to other speakers
Supply and laying of Audio cables and connectors of sufficient lentgh for a, Wireless recever to audio mixer; b, Goosneck mic/ boundary layer mic to Audio mixer; c, Computer to Audio Mixer, d, Audio mixer to computer e, audio mixer to powered speakers, Power and audio cables for speakers, etc.. - through suitable conduit
Audio rack for housing above parts neatly
Video Equipments
Non reflective fixed projection screen 7x5"
PTZ camera with ceiling mount stand Smooth motorized pan tilt and zoom, controlled from remote or console 70-100° field of view -100 to +100°pan,-30 to +30° tilt(PTZ) Output: H.264, YUY2/MJPEG Zoom: 12X lossless HD zoom or 4X optical with 3X digital or 10X optical zoom Resolution:1080p, 720p or above Connectivity: USB Focus: Auto focus 3 camera preset Standard tripod thread Flicker free Remote Control for camera preferred brand: Logitech, Sony, panasonic,Polycom, Lumens, People link, Aver
High end computer core i5, 8 GB DDR4 RAM, 256 GB SSD, 1 TB HDD, Win 10 Home and Microsoft Office.18.5 inch LED monitor
Steel Compute table with medium back steel revolving chair of premium brand
Lecture Podium with Gooseneck mic
Digital writing pad with Stylus and free software ( including driver) for desktop PC. 10" size, with Wireless and wired connectivity (cable length -3 m)
Supply and laying of Video cables of sufficient length a, High speed HDMI cable from computer to Projector; b, high speed USB cable from PTZ camera to Computer - through suitable conduit
2 KVA UPS with one hour battery (SMF) backup and closed Rack
Additional componets if required (split up details may be provided seperately)
For theatre class rooms
Audio equipments of make Ahuja, Studio master, Bheringer, AKG, Soundcraft, Shure,Audio technical, Bayerdynamic)
Four channel wireless receiver with hand held mic ( 2 no) and lapel mic (1 no) with body pack transmitters. No. of channels 4 Input:1Xhandheld mic,1X lapel mic Frequency response:60Hz-15000Hz
Head band mic Uni directional suitable for above Wireless receiver and body pack transmitters
240 W PA mixer amplifier Power output:240W Rms Input: Stereo input L/R, 6X mic, 2X AUX Outputs: speaker outputs, preamp out and Line output Short circuit / overload protection frequency response: 50Hz-15000Hz
100 W speakers of suitable ohm/V for above amplifier (4 no. for each large rooms)(4x10=40) Power:100W RMS Frequency Response:55-16000Hz Additional: Wallmount accessories Line out to other speakers
Boundary layer microphone for podium
Supply and laying of Audio cables and connectors of sufficient lentgh for a, Wireless recever to amplifier; b, Goosneck mic/ boundary layer mic to amplifier; c, Computer to amplifier, d, amplifier to computer e, amplifier to speakers, Power and audio cables for speakers, etc.. - through suitable conduit
Audio rack for housing above parts neatly
Video Equipments
Non reflective fixed projection screen 8x6"
PTZ camera for audience with ceiling mount/wall mount stand Smooth motorized pan tilt and zoom, controlled from remote or console 70-100° field of view -100 to +100°pan,-30 to +30° tilt(PTZ) Output: H.264, YUY2/MJPEG Zoom: 12X lossless HD zoom or 4X optical with 3X digital or 10X optical zoom Resolution:1080p, 720p or above Connectivity: USB Focus: Auto focus Remote Control for camera Preset zones support Standard tripod thread Flicker free RS 232/ethernet control for camera preferred brand: Logitech, Sony, panasonic,Polycom, Lumens, aver, poeples link
Voice tracking PTZ camera for presenter with ceiling mount stand voice tracking or tracking of presenter function Smooth motorized pan tilt and zoom, controlled from remote or console 70-100° field of view -100 to +100°pan,-30 to +30° tilt(PTZ) Output: H.264, YUY2/MJPEG Zoom: 12X lossless HD zoom or 4X optical with 3X digital or 10X optical zoom Resolution:1080p, 720p or above Connectivity: USB Focus: Auto focus Remote Control for camera Preset zones support Standard tripod thread Flicker free RS 232/ethernet control for camera preferred brand: Logitech, Sony, panasonic,Polycom, Lumens, aver, poeples link
Digital podium with interactive touch display. 19.5"Full HD (1920 x 1080). 10-point projected capacitive touch technology. stylus digital pen for screen writing. Stable bookstand design, Enhanced viewing comfort. Swivel Caster Wheel with lock. Windows 10 pro OS with writing pen, Microsoft office latest version. PC specification: Intel Corei7 latest Desktop Processor. 256 GB SSD, 16 GB RAM, 2GB graphics card, 2 TB HDD, USB 3.2 connectivity, LAN, HDMI; Inbuilt PA Gooseneck Microphone.
Installtion and configuration of free software like OBS for video processing such as mixing of camera inputs and presentation to one video for streaming and recording etc.
Supply and laying of Video cables of sufficient lentgh a, High speed HDMI cable from computer to Projector; b, high speed USB cables and control cables from PTZ camera to Computer - through suitable conduit
2 KVA UPS with one hour battery (SMF) backup and closed Rack
Additional componets if required (split up details may be provided seperately)
Description of Work / Item(s)
Materials
3x3 good quality PVC Box, faceplate and I/O
CAT 6 UTP cable (Molex/Amp/ NORDEN)
RJ 45 connector
20mm/25 mm white iso certified PVC pipe with accessories
24 port L2 Managed switch, with 4 nos 1Gbps SFP port, lifetime warranty, HP/NETGEAR/CISCO
48 port L2 Managed switch with 4 nos 1Gbps SFP port, lifetime warranty, HP/NETGEAR/CISCO
9U rack with 24 port fully loaded patch panel, cable manager, power extension board
HDPE pipe for drawing OFC
1m patch cord CAT 6
2m patch cord CAT 6
Outdoor armoured Optical Fiber cable - 12 Core single mode with 1 GBPS connectivity
1G SFP module of same make of switch and required patch cord
Fully loaded 12 port LIU
Labour
RJ 45 / IO Termination Charges
Faceplate Fixing Charges
3/3 PVC Box fixing Charges (Surface)
Cat6 UTP Laying Charges
20mm/25mm white PVC Pipe Laying Charges through surface
Fixing and Configuration of Switch
Fixing and Dressing of wall mount rack
Fixing and ports termination of Patch panel.
LIU Fixing & dressing
Trenching earth up to 3 ft depth including road cutting and making good with cement concrete as per approved specification, Laying of HDPE, Baked brick layering, Refilling and restoration (For laying OFC).
OFC Splicing Charges
Additional componets if required (split up details may be provided seperately)
Description of Work / Item(s)
Server - For details Check Annexure I
Server:two numbers of 3rd generation Intel Xeon Gold / 3rd Gen AMD EPYC Processor, 2.1 Ghz,22 core or higher, 512 GB, 2 x 200 GB SSD/above 2.5” with hardware RAID 1, 2x400 GB SAS SSD Write Intensive 2.5”, 12 X 2.4 TB, 2.5” SAS, 10K RPM 16GB FC HBA, RPS (Detailed specification mentioned in Prequalification document)
Virtualization - For details Check Annexure I
VMware Cloud Foundation Starter (Per CPU) includes vSphere Enterprise Plus, vSAN Advanced, NSX Data Center Advanced, vRealize Suite Standard, vRealize Network Insight Advanced, and SDDC Manager for vSAN.
Production Support/Subscription for VMware Cloud Foundation 4 Starter (Per CPU) for 5 years
VMware vCenter Server 6 Standard (Per Instance)
24x7 Production Support/Subscription for VMware Vcenter Standard for 5 years from VMware OEM
24 Port 10G SFP+ switch, 2 x 100G Uplinkswith 5 Year 24x7 Next Business Day Onsite Service (Detailed specification mentioned in Prequalification document)
24 Port Base-t Gigabit Ethernet switch fully managable with 5 Year support (Detailed specification mentioned in Prequalification document)
Site Recovery Manager 25 VM Pack
Site Recovery Manager 25 VM Pack Support/Subscription for 5 years
Backup solution with 5 year support
Additional componets (if any such as cables and accessories, Training,Documentation ,implementation etc)
Centertec
Centertec
Macro Enterprises
Macro Enterprises
Centertec
Bidder Name
Macro Enterprises
Centertec
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .