| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical Rejected Tecnically |
| 3 | Rejected-Technical 53 BANKIM CHANDRA ROAD HAKIMPARA SILIGURI 734001 | SILIGURI | DARJEELING | WEST BENGAL | 734001 | Rejected-Technical Commercially Rejected |
| 4 | Rejected-Technical | Rejected-Technical Tecnically Rejected |
Tender Value
Refer Docs
EMD Value
₹21,745
Closing Date
18 Sept 2024, 3:00 pmClosed
CE, SLDC
Office of the Chief Engineer, SLDC, WBSETCL Howrah 220 KV Sub Station Campus, 100 Feet Road, P.O. Danesh Sheikh Lane, Howrah, PIN.711 109
New Electrical Wiring installation work for light, fan, exhaust fan point, ACs power point etc. at newly constructed ANNEX Building of SLDC, WBSETCL, at Howrah District-2ND call
2024_SETCL_739472_1
CE(SLDC)/WBSETCL/WIRING/ 2024-25/03 dated 28.08.2024
Open Tender
Miscellaneous Services
Item Wise
SLDC
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹21,745
Yes
SLDC
8 Oct 2024
28 Aug 2024
20 Sept 2024
28 Aug 2024
18 Sept 2024
5 Sept 2024
28 Aug 2024 - 30 Aug 2024
2 Sept 2024
Supply, Installation, Testing & Commissoning of suitable dimension, Floor-cum-wall/Wall mounted & Indoor type Cubicle LT PANEL suitable for 415V, 3-ph, 4-Wire, 50 Hz AC supply system having Single/Double Door feature and encloser made up of Steel Sheet (thickness 1.6 mm). Panel must be properly painted by powder coating and equipped with IP 41 Protection. Microprossor based LT Panel Chamber and LT panel should have AMF control option with suitable size of SFU as a manual by-pass option and necessary connections as required in SLDC which is to be approved by EIC. A) Incoming Arrangement: (i) 415V, 50Hz, 200A, 4 pole, MCCB microprocessor based [Make: Schneider/ABB/L&T]) with Breaking Capacity of 36 kA, and with microprocessor based Release Protection Scheme -- 2 Nos, (ii) Tape insulated, Ring type, Bar Primary metering CT, CL-1, 15VA, Rating-200/5A -- 1 Set of 3 Nos. (Kappa/AE), (iii) Smart metering (measuring V, I, PF, kW, kWh, kVAR etc. and remote monitoring arrangement through internet on any Computer, of these quantities --- full setup to be done) by Digital Multifunction Meter (LT/Siemens) only for Incomer. - - - - - - - - - - - - - - 1 Set. B) Bus Section: (i) Bus Bar Material: Electrolytic Copper, 90% pure in nature, Semi soft, Tin electroplated, (ii) Size of Bus Bar: suitable size of 250 A Current carrying capacity (Phases as well as neutral), (iii) Bus Short-circuit withstand capacity: 36kA for 1 sec, (iv) Bus-Bar Insulation: Bus-bar must be fully shrouded by insulating sleeve. C) Outgoing: (1) 63A, 4 Pole MCB (Ics-10KA up to 415V) [Make: Schneider/ABB/L&T]) - - - - 4Sets, (2) 40A, 4 Pole MCB (Ics-10KA up to 415V) [Make: Schneider/ABB/L&T]) - - - - 4sets, 3) 32A, 4 Pole MCB (Ics-10KA up to 415V) [Make: Schneider/ABB/L&T]) - - - - 4sets, 4) 25A, DP MCB (Ics-10KA up to 415V) - - - - 12 Nos. [Make: Schneider/ABB/L&T]) D) Feeder Connection (per phase & neutral): Solid connection to Main Bus Section (No wire). E) Termination: Incoming cable termination Bus (each phase) should be suitable for 2 Nos., 4 C × 120/95 sq.mm. Aluminium (Armoured) XLPE/PVC Cable (KEI/Finolex/Mescab) outgoing feeder terminals as per rating. F) Miscellaneous: (1) S&F Danger board of size 1'×1' on the front face of LT Panel - - - 1 No. (2) All switches (MCCB etc.) required, shall be fixed by S.S. nuts & bolts on angle/flat iron frame base as per requirement & as per the direction of E.I.C, (3) All separate compartments for MCCBs etc. must be marked with Name Plates, according to their Outgoing or Incoming connections, as per direction of E.I.C, (4) There must be cable entry box of appropriate size and of same material & guage as that of the main panel, at up-side & down-side of the panel, (5) Control circuit to be protected by MCCB having all types of logic combination as desired in SLDC by EIC and control wiring to be of 1.5 sq. mm. (min.) copper wire, (6) Panel Board must have indicator lamps for R-Y-B indication, (7) Panel must have provision for top & bottom - both end cable entry.
Supply, Installation, Testing & Commissoning of suitable dimension, Floor-cum-wall/Wall mounted & Indoor type Cubicle LT PANEL suitable for 415V, 3-ph, 4-Wire, 50 Hz AC supply system having Single/Double Door feature and encloser made up of Steel Sheet (thickness 1.6 mm). Panel must be properly painted by powder coating and equipped with IP 41 Protection. Microprossor based in LT Panel Chamber and LT panel should have AMF control option with suitable size of SFU as a manual by-pass option and necessary connections as required in SLDC which is to be approved by EIC. A) Incoming Arrangement: (i) 415V, 50Hz, 125A, 4 pole, MCCB microprocessor based [Make: Schneider/ABB/L&T]) with Breaking Capacity of 36 kA, and microprocessor based Release Protection Scheme -- 2 Nos., (ii) Tape insulated, Ring type, Bar Primary metering CT, CL-1, 15VA, Rating-200/5A -- 1 Set of 3 Nos. (Kappa/AE), (iii) Smart metering (measuring V, I, PF, kW, kWh, kVAR etc. and remote monitoring arrangement through internet on any Computer, of these quantities. B) Bus Section: (i) Bus Bar Material: Electrolytic Copper, 90% pure in nature, Semi soft, Tin electroplated, (ii) Size of Bus Bar: suitable size of 150 A Current carrying capacity (Phases as well as neutral), (iii) Bus Short-circuit withstand capacity: 36kA for 1 sec, (iv) Bus-Bar Insulation: Bus-bar must be fully shrouded by insulating sleeve. C) Outgoing: (1) 40A, DP MCB (Ics-10KA up to 415V) [Make: Schneider/ABB/L&T])- - - - - - - - - - -12 Sets, 2) 63A, DP MCB (Ics-10KA up to 415V) [Make: Schneider/ABB/L&T])- - - - - 4set, D) Feeder Connection (per phase & neutral): Solid connection to Main Bus Section (No wire). F) Miscellaneous: (1) S&F Danger board of size 1'×1' on the front face of LT Panel - - - 1 No. (2) All switches (MCCB etc.) required, shall be fixed by S.S. nuts & bolts on angle/flat iron frame base as per requirement & as per the direction of E.I.C, (3) All separate compartments for MCCBs etc. must be marked with Name Plates, according to their Outgoing or Incoming connections, as per direction of E.I.C, (4) There must be cable entry box of appropriate size and of same material & guage as that of the main panel, at up-side & down-side of the panel, (5) Control circuit to be protected by MCCB having all types of logic combination as desired in SLDC by EIC and control wiring to be of 1.5 sq. mm. (min.) copper wire, (6) Panel Board must have indicator lamps for R-Y-B indication, (7) Panel must have provision for top & bottom - both end cable entry.
Supplying and fixing of double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish including interconnection with suitable size of copper wire and neutral link & provision for earthing attachment (Make: Legrand/Schneider/L&T) -- 6 way.
Supplying and fixing of double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish including interconnection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make: Legrand/Schneider/L&T) -- 2+12 way.
Supplying and fixing of 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand/Schneider/L&T) -- SP (6-32A).
Supplying and fixing of 240/415 V MCB Isolator on din rail of existing DBs and necessary connection (Make: Legrand/ Schneider/ L&T). i) DP, 63 A.
Supplying and fixing of 240/415 V MCB Isolator on din rail of existing DBs and necessary connection (Make: Legrand/ Schneider/ L&T). ii) FP, 63 A.
Supplying and fixing of MCCB SS enclosure with IP 20/30 protection, powder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish on flat iron frame including painting, connection & provision for earthing attachment. Supplying and fixing of 415 V, 40A, FP MCB Isolator on din rail of existing DBs and necessary connection (Make: Legrand /Schneider /L&T).
Supplying and fixing of MCCB SS enclosure with IP 20/30 protection, powder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish on flat iron frame including painting, connection & provision for earthing attachment. Supplying and fixing of 415 V, 32A, FP MCB Isolator on din rail of existing DBs and necessary connection (Make: Legrand /Schneider /L&T).
Supplying and fixing of MCCB S.S. enclosure with IP 20/30 protection, powder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish on flat iron frame including painting, connection & provision for earthing attachment. Supplying and fixing of 415 V, 63A, FP MCB Isolator on din rail of existing DBs and necessary connection (Make: Legrand /Schneider /L&T).
Distribution wiring in 22/0.3 (1.5 sq.mm.) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR Kabel/Finolex/KEI/Polycab, approved by EIC) in 19 mm. bore, 3 mm. thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Make- Legrand, Arteor/Myrius/Schneider clipsal X) fixed on Modular GI switch board with top cover plate flushed in wall including mending good damages to original finish. Average run 10 mtr.
Distribution wiring in 22/0.3 (1.5 sq.mm.) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR Kabel/Finolex/KEI/Polycab, approved by EIC) in 19 mm. bore, 3 mm. thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Make- Legrand, Arteor/Myrius/Schneider clipsal X) fixed on Modular GI switch board with top cover plate flushed in wall including mending good damages to original finish. Average run 11 mtr.
Distribution wiring of 1.1 kV grade 22/0.3 (1.5 sq.mm.) single core stranded 'FR' PVC insulated & unsheathed copper wire (RR Kabel/Finolex/KEI/Polycab, approved by EIC) in 20 mm. size PVC rigid conduit 'FR' (Precision make), with 1.1 kV grade 1 × 22/0.3 (1.5 sq.mm.) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A, 5 pin Modular type plug socket & switch (Make- Legrand, Arteor/Myrius/Schneider clipsal X) on 4 Module GI switch board with 3/4 Module top cover plate on wall including necessary connection making earthing attachment, painting and mending good damages to building works. On Board.
Supplying & Fixing of only Call Bell/Buzzer on single HW board on wall including S&F single HW board as per GS.
S & F of 48'' sweep, 230V, 1-phase, AC ceiling fans including all accessories, the capacitor of fan must be P-2 type burst proof & must have safety wire directly linked from fan hook to stator of fan, complete with blades, canopy, fork, rubber bush etc. including S&F connecting wire for down rod up to 30 cm including painting of rod with approved paint and making necessary connection as required by 2×1.5 sq. mm. flexible copper wire. [Make: Crompton-HS/Riviera High Speed/Orient) --- Color-Brown].
Engraving the deptt. number with 10 mm lettering on the body of fan up to 10 letters including hyphen, stroke or stop.
S & F of 120/240V Electronic Fan Regulator - Step type socket size as per direction of the E.I.C. including making necessary conncetion. (Make- Anchor/Vinay/Kolors).
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. including S&F connecting wire for down rod up to 30 cm including painting of rod with approved paint and making necessary connection as required by 2×1.5 sq.mm. flexible copper wire.
Supplying & Fixing of Box type fan clamp of 150 mm dia & 80 mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, including S&F 12 mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, including binding the rod and fan box with reinforcement by 22 SWG steel binding wire, including supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
Supply of 240V, Twin LED tube light Fittings complete with all accessories (Make: Philips make cat no. TMC-501 P 2×T-LED for batten and cat no. 18W865 T8 for Master LED tube) including supply of two nos 20W LED Tube light (LT8-20-865-(2).
Fixing only fluorescent light fitting suspended 25 cm below the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports including S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2×24/0.20 mm (1.5 sq.mm.) flexible copper wire of 1.10 mt. length.
S&F of 230V grade 400 mm sweep (18") wall mounting bracket fan (metal body & metal blade) on wall including S & F of MS fastners and nut & bolts etc. as required. (Make-- EPC).
Supply and fixing of 240V, 9'', 1370 rpm AC exhaust fan (EPC Make) after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necessary length of PVC insulated wire and making connection for exhaust of given diameter.
Fixing only louver shutter/cowl on wall with necessary bolts & nuts (6 mm dia × 62 mm long) for 30 cm (12") Exhaust fan.
Supply & Fixing 240V, 3 nos. 6A, 1 no 16A, 3 pin Modular type plug socket with 3 nos. 6A & 1 no. 16A, Modular type switch (Make- Legrand, Arteor/Myrius/ Schneider clipsal X), without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall including S&F switch board and cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing of 240V, 2 nos. 6/16A, 5 pin Modular type plug socket with 2 nos. 6/16A, Modular type switch (Make- Legrand, Arteor/Myrius/Schneider clipsal X), without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall including S&F switch board and cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing of 240V, 4 nos. 6/16A, 5 pin Modular type plug socket with 4 nos. 6/16A, Modular type switch (Make- Legrand, Arteor/Myrius/Schneider clipsal X), without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall including S&F switch board and cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing of 240V, 2 nos. 6A, 1 no 16A, 5 pin Modular type plug socket with 2 nos. 6A & 1no 16A, Modular type switch (Make- Legrand, Arteor/Myrius/ Schneider clipsal X), without plug top on 12 Module GI Modular type switch board with 12 Module top cover plate flushed in wall including S&F switch board and cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2 nos. 6 A, 5 pin Modular type plug socket (Make- Legrand, Arteor/Myrius/Schneider clipsal X) with 2 Nos. 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall including S&F switch board and cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc.
Supply and fixing of 2' × 2' False ceiling fittings (Make : Philips, Model : RC380B LED30S G4 L60 W60 PSU OD OC HSN Code:9405) with all necessary connection as per direction of EIC.
Supply and fixing of 2' × 2' False ceiling fittings (Make : Philips, Ordering Code:RC600B M LED 40S-6500/5700/4000 PSU W 30 L120WH ) with all necessary connection as per direction of EIC.
Supply and fixing of 2' × 2' False ceiling fittings (Make : Philips, Ordering Code: RC600B M LED 40S-6500/5700/4000 PSD W 30 L120WH ) with all necessary connection as per direction of EIC.
Dali -- dimmer Contro for controlling option of up to 12 nos of (RC600B M LED 40S-6500/5700/4000 PSD W 30 L120WH) PSD lighting with all necessary arrangement (Make-Philips).
Supply and fixing of LED downlighter with PDC housing recessed at False ceiling fittings (Make : Philips, Ordering Code: DN296B LED12S-6500/5700/4000 PSU WH) with all necessary connection as per direction of EIC.
Supplying and Drawing 1.1 kV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR Kabel/Finolex/KEI/Polycab, approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection as required. 2×1.5 sq.mm. + 1×1.5 sq.mm. as ECC.
Supplying and Drawing 1.1 kV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR Kabel/Finolex/KEI/Polycab, approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection as required. 2×2.5 sq.mm. + 1×1.5 sq.mm. as ECC.
Supplying and Drawing 1.1 kV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR Kabel/Finolex/KEI/Polycab, approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection as required. 2×4 sq.mm. + 1×2.5 sq.mm. as ECC.
Supplying and Drawing 1.1 kV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR Kabel/Finolex/KEI/Polycab, approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection as required. 2×6 sq.mm. + 1x×4sq.mm. as ECC for SPN DB.
Supplying and Drawing 1.1 kV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR Kabel/Finolex/KEI/Polycab, approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection as required. 4×80/0.4 (16 sq.mm.) + 2×84/0.3 (6 sq.mm.) as ECC for 16 TR AC .
Supplying and Drawing 1.1 kV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR Kabel/Finolex/KEI/Polycab, approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection as required. 4×84/0.3 (6 sq.mm.) + 2×56/0.3 (4 sq.mm.) as ECC for 8.5 TR and 5.5 TR AC.
Supplying and Drawing 1.1 kV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR Kabel/Finolex/KEI/Polycab, approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection as required. 4×126/0.4 (16 sq.mm.) + 2×80/0.4 (10 sq.mm.) as ECC for TPN.
Cutting channel of 40 mm x 40 mm size on masonry wall including S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire including mending good damages to building works. 19 mm dia × 3 mm thick polythene pipe without earth continuity wire.
Cutting channel of 43 mm × 43 mm size on masonry wall including S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire including mending good damages to building works. 25 mm dia × 3 mm thick polythene pipe without earth continuity wire.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2.5/1.5 sq.mm.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 4 sq.mm.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 6 sq.mm.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 10 sq.mm.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 16 sq.mm.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 35 sq.mm.
Supply & delivery of following AL, XLPE Armoured (RR Kabel/FinolexGloster/KEI, Approved by EIC) (NS). 4C 50 sq. mm. (For UPS and lighting panel).
Supply & delivery of following AL, XLPE Armoured (RR Kabel/FinolexGloster/KEI, Approved by EIC) (NS). 4C 95 sq. mm. (For AC Panel).
Laying of cable above 4C core 50 sq.mm. and up to 4C core 120 sq.mm. on wall/surface including S & F MS clams with earthing attachment in 2 × 10 SWG, GI (Hot Dip) Wire, making hole etc. as necessary, mending good damages and painting.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below For 4 core. up to 95 sq.mm.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below For 4 core. up to 50 sq.mm.
Finishing the end of following XLPE/PVC armoured cables by crimping method including supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. 3½ core 95 sq.mm. cable.
Finishing the end of following XLPE/PVC armoured cables by crimping method including supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. 4 core 50 sq.mm. cable.
Earthing with 50 mm dia GI pipe 3.64 mm thick × 3.04 Mts. long and 1 × 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers including S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: i) By TATA-Medium GI pipe.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm × 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
S&F earth busbar of galvanized (Hot Dip) MS flat 25 mm × 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .