ASSISTANT ENGINEER
ASSISTANT ENGINEER lLID EW section malayattoor neeleeswarm gp
GENERAL Mayayattoor GP Women Development Centre Wards 1 and 12Electrification of newly buil Up area General Electrical Work GENERAL Mayayattoor
2025_LSGD_812854_2
5/AE/LSGD/MN/25-26
Open Tender
Electrical Works
Item Rate
MALAYATTOOR NEELEESWARAM GP
Refer etender details
7 documents required · 7 mandatory
₹555
Yes
Yes
29 Oct 2025
22 Oct 2025
3 Nov 2025
22 Oct 2025
31 Oct 2025
22 Oct 2025
Work Name:GENERAL-Mayayattoor GP - Women Development Centre - Wards 1 and 12-Electrification of newly built-up area-General Electrical Work
es and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short pointpoint|90.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short pointé5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.setª90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)metre90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)Y1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.MOD231383/2024-2025:Supply and providing LED bulb 9/12watts Philips/equivalent"Women Developemnt Centre - Ward 12/OD231364/2024-2025:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, 25 Amps residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.MOD231382/2024-2025:Supply and providing LED bulb 9/12watts Philips/equivalent
Work Name:GENERAL-Mayayattoor GP - Women Development Centre - Wards 1 and 12-Electrification of newly built-up area-General Electrical Work
es and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short pointpoint|90.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short pointé5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.setª90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)metre90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)Y1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.MOD231383/2024-2025:Supply and providing LED bulb 9/12watts Philips/equivalent"Women Developemnt Centre - Ward 12/OD231364/2024-2025:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, 25 Amps residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.MOD231382/2024-2025:Supply and providing LED bulb 9/12watts Philips/equivalent
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.18 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.71 MB
sbdnit.pdf
Tender Documents • 1.76 MB
BOQ_1358671.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .