GE (AF) Pathankot
GE (AF) Pathankot 145001
REPAIR AND MAINT OF CERTAIN FIRE ALARM SYSTEM IN AC-III (02 NOS) (01 OPERATOR ROOM), BLOCK (03 NOS) DB-8 (02 NOS) WSA AREA AT AIR FORCE STATION PATHANKOT
2024_MES_644360_1
3014/Q/40/E3
Limited
Miscellaneous Services
Item Rate
30 days
GE (AF) Pathankot
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
18 Jul 2024
27 Feb 2024
7 Mar 2024
27 Feb 2024
5 Mar 2024
28 Feb 2024
Amount
(a) Repair of fire alarm system in AC-III (02 Nos) and AC-I (01 No of operator room) Testing of fire alarm system zone will from 2 zone to 10 zone by smoke test to all parts of alarm system as sensors, smoke detectors, response indicator, heat detector, manual box, hooter, control panel etc. 3 Each Job, Replacement of following parts of the fire alarm system:- (a) Semi conventional fire alarm control panel 10 Zone - 2 Each, (b) Hooter - 2 Each, (c) LED Flasher - 4 Each, (d) Manual Call point- 8 Each, (e) Fire alarm control panel programming of existing panel - 2 Each Job, (f) Replacement of MCB, SPN 16 Amps - 6 Each, (g) Replacement of wiring for fire alarm system- 20 RM, (h) Replacement of battery 12 V, 7Ah - 3 Each, (j) Semi conventional fire alarm control panel 4 zone- 2 Each, (k) Smoke detector- 12 Each. (b) Repair and maint of certain fire alarm system in Bahadur Block (03 Nos), PMS-193 (02 Nos), DB-8 (02 Nos), AC-III (02 Nos) and AC-I (01 No of operator room) Testing of fire alarm system zone will from 2 zone to 10 zone by smoke test to all parts of alarm system as sensors, smoke detectors, response indicator, heat detector, manual box, hooter, control panel etc. 4 Each Job. Replacement of following parts of the fire alarm system:- (a) Semi conventional fire alarm control panel 10 Zone - 3 Each, (b) Hooter - 3 Each, (c) LED Flasher - 4 Each, (d) Manual Call point- 8 Each, (e) Fire alarm control panel programming of existing panel - 2 Each Job, (f) Replacement of MCB, SPN 16 Amps - 6 Each, (g) Replacement of wiring for fire alarm system- 20 RM, (h) Replacement of battery 12 V, 7Ah - 3 Each, (j) Semi conventional fire alarm control panel 4 zone- 2 Each, (k) Smoke detector- 12 Each.
KUMAR TRADING CO
M/S SINGH AND ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .