Executive Engineer
Kerala Water Authority Project Division Kushal Nagar Kanhangad
Jal Jeevan Mission JJM JJM Kasaragod District WSS to Chengala Muliyar Mogral Puthur and Madhur Grama Panchayaths Scheme improvement works Maintenance of long and unused transformers pump sets and accessories etc at the Intake well cum pumphouse at
2024_KWA_683978_1
02/2024-25
Open Tender
Miscellaneous Works
Item Rate
90 days
Bavikkara
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,760
₹50,000
29 Aug 2024
5 Aug 2024
13 Aug 2024
5 Aug 2024
12 Aug 2024
5 Aug 2024
Amount
Appendix 1 : Electrical maintenance works at WTP Bavikkara - Repair/Rewinding of 110HP Kirloskar Induction motor
OD76204/2024-2025:Disconnection of electric cable from the terminal box of 110HP Kirloskar motor Decoupling the motor from the 110 Hp split case pump set and lifting the motor from the foundation bed using tripod, chain pulley block and heavy mazdoor, shifting out of pump house, loading to a hired vehicle and transporting to authorized work shop for rewinding including all labor hire charge of lifting equipment and vehicle charges etc complete. (Special officer Electrical. PRJ(KSD)-18/24/18.07.2024)
OD76205/2024-2025:Dismantling the motor and separating the rotor and stator, cutting and pulling the burnt copper winding /fiber strip/insulating materials from the stator. Cleaning the stator slots by CTC solution and insulating the slot using H class insulations (Special officer Electrical. PRJ(KSD)-18/24/18.07.2024)
OD76206/2024-2025:Labour charge for rewinding the stator with super enameled copper wire forming coil of existing gauge and turns winding without any damages, making connection, joining lead wire and packing the winding with H class insulating materials/fiber strip/ heating winding and varnishing etc complete (Special officer Electrical. PRJ(KSD)-18/24/18.07.2024)
OD76207/2024-2025:The cost of duel coat H class copper winding wire, Total 50 Kg (Special officer Electrical. PRJ(KSD)-18/24/18.07.2024)
OD76208/2024-2025:Cost of insulation materials H class Nomax paper, Fiber glass tap, Sleeves, Varnish and Wedges (Special officer Electrical. PRJ(KSD)-18/24/18.07.2024)
OD76209/2024-2025:Cost of Fiber glass insulated copper wire for terminal connection (35sq mm wire 7meter Rs 700/meter) (Special officer Electrical. PRJ(KSD)-18/24/18.07.2024)
OD76210/2024-2025:Baking, varnishing, and processing the rewind stator (Special officer Electrical. PRJ(KSD)-18/24/18.07.2024)
OD76211/2024-2025:Assembling the motor inserting the rotor in to stator using chain pulley, and fixing all dismantled parts painting the motor and testing etc (Special officer Electrical. PRJ(KSD)-18/24/18.07.2024)
OD76212/2024-2025:Loading the assembled motor to the vehicle using tripod chain pulley and heavy mazdoor etc (Special officer Electrical. PRJ(KSD)-18/24/18.07.2024)
OD76213/2024-2025:Hire charge of vehicle from work shop to pump house at Bovikkanam (Special officer Electrical. PRJ(KSD)-18/24/18.07.2024)
OD76214/2024-2025:Re erecting the motor on the existing base plate, coupling the pump and motor with correct alignment, connecting electrical connections and trail run in the presents of KWA Engr-in-charge etc complete. (Special officer Electrical. PRJ(KSD)-18/24/18.07.2024)
Appendix 2 : Electrical maintenance works at WTP Bavikkara - Servicing of long unused 130 HP Kirloskar induction motor and 130 HP Flowmore split case pump set - 2 nos
OD76347/2024-2025:Towards the labour charges for decoupling 130 HP Kirloskar induction motor and 130 HP Flowmore split case pump set and dismantling the non-rotating Flowmore split case pump cleaning and servicing impeller, gland, greasing end bearing, making free rotation and assembling using fresh packing etc complete
OD76348/2024-2025:Towards the labour charges for dismantling 130 HP kirloskar motor, cleaning and greasing bearings, assembling coupling to pump and testing etc complete (Special officer Electrical. PRJ(KSD)-17/24/18.07.2024)
OD76349/2024-2025:Dismantling the 130 hp soft starter panel, servicing all contactor set and control wirings, assembling and testing etc complete (Special officer Electrical. PRJ(KSD)-17/24/18.07.2024)
OD76350/2024-2025:Supplying DIN type 125 A Fuse link size 00 0 (Special officer Electrical. PRJ(KSD)-17/24/18.07.2024)
Appendix 3 : Electrical maintenance works at WTP Bavikkara - Servicing and overhauling of long unused 35 HP Kirloskar induction motor and 35 HP Flowmore split case pump set 2 nos-
OD76682/2024-2025:Towards the labour charges for decoupling 35 HP Kirloskar induction motor and 35 HP Flowmore split case pump set and dismantling the non-rotating Flowmore split case pump cleaning and servicing impeller, gland, greasing end bearing, making free rotation and assembling using fresh packing etc complete
OD76683/2024-2025:Towards the labour charges for dismantling 35 HP kirloskar motor, cleaning and greasing bearings, assembling coupling to pump and testing etc complete (Special officer Electrical. PRJ(KSD)-19/24/18.07.2024)
OD76684/2024-2025:Dismantling the 35 hp star delta starter panel, servicing all contactor set and control wirings, assembling and testing etc complete (Special officer Electrical. PRJ(KSD)-19/24/18.07.2024)
OD76685/2024-2025:Supplying DIN type 125 A Fuse link size 00 0 (Special officer Electrical. PRJ(KSD)-19/24/18.07.2024)
Appendix 4: Electrical maintenance at Intake well cum pump house at Mottel - Lifting and Repair / Service of long unused 250 KW / 3300 V Kiloskar Vertical Trubine Motor pump set of intake well pump house
OD76719/2024-2025:Towards the labour charges for disconnecting electrical cable and, earth connection, dismantling of motor and pump joining coupling, and separating and lifting of 250 KW / 3300 V Kiloskar VT motor from base plate, moving and stacking in pump house corner. And Lifting 250 KW Flowmore VT pump set from the well by dismantling pump surface discharge head and taking out the same, cutting, chipping rusted bolt nut from column pipe flange and dismantling line shaft assembly, spider set, one by one and 250 mm column pipe, as the same lifting 10 nos 5 feet long column pipe, lifting, moving, and stacking in pump house, and checking the complaint in detail in the presents of KWA in charge etc. including all labour charges (Special officer Electrical. PRJ(KSD)-14/24/18.07.2024)
OD76720/2024-2025:Towards the labour charges for dismantling the unrotated the 6 stage Flowmore VT pump and servicing by separating the discharge bowl, suction bell and 6 nos intermediate bowls (stage bowl) and impeller one by one cleaning and re-assembling the pump, making free rotation using special tools by skilled mechanic (Special officer Electrical. PRJ(KSD)-14/24/18.07.2024)
OD76721/2024-2025:Labour charges for Dismantling 250 KW / 3300 V Kiloskar VT motor servicing and heating until getting megger value and greasing the induction motor (Special officer Electrical. PRJ(KSD)-14/24/18.07.2024)
OD76722/2024-2025:After servicing pump and all spider assembly Re-erecting the pump assembly to the well using chain pulley, by attaching the first line shaft to pump shaft, 250 mm flanged heavy column pipe and spider assembly with using necessary packing and lowering to well , as the same way lowering 10 nos column pipe with line shaft and spider bush one by one, and fitting the surface discharge head to the last column pipe lowering and fixing on the sole plate, inserting gland rope in stuffing box and making smooth rotation, connecting the delivery flange to the existing pumping main, fixing the 250 KW / 3300 V Kiloskar VT induction motor on the discharge head connecting the pump shaft coupling to motor coupling adjusting the pump etc, and making the earth connection and power connection in motor terminal box and conducting trial run etc complete including the cost of materials like oil putty, grease oil, packing rubber of various sizes, hire charges of tools, such as chain wrench etc.
OD76723/2024-2025:Making arrangement for heating the HT motor at regular intervals (Special officer Electrical. PRJ(KSD)-14/24/18.07.2024)
Appendix 5: Electrical maintenance at Intake well cum pump house at Mottel - Repair / Service of long unused 11 KV HT VCBs, Transformers, Capacitor feeders, FCMA Starters and all control panel systems of intake well pump house
OD76884/2024-2025:Towards the labour charges for Repair / Service of 12 KV/630 A HT Vacuum Circuit Breaker, Cleaning dust and servicing breaker complete mechanism and spring charging motor, Servicing / replacing control panel wiring destroyed by rats , Servicing relays, switches, indicators, cleaning and heating bus bar and chamber, Servicing CT and 3 phase voltage Transformer and replacing if necessary, scraping the rusted parts of panel board and painting etc complete (Main incoming VCB -1, Outgoing to Transformer -3) and commissioning (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76885/2024-2025:Towards the labour charges for Repair / Service of 3.6 KV/630 A HT Vacuum Circuit Breaker, Cleaning dust and servicing breaker complete mechanism and spring charging motor, Servicing / replacing control panel wiring destroyed by rats , Servicing relays, switches, indicators, cleaning and heating bus bar and chamber, Servicing CT and 3 phase voltage Transformer and replacing if necessary, scraping the rusted parts of panel board and painting etc complete. (Incoming from 3 nos transformer and to 3 nos motor starter ) and commissioning (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76886/2024-2025:Towards the labour charges for Repair / Service of Capacitor feeder and commissioning (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76887/2024-2025:1000 KVA Krloskar make HV 11000 V / LV – 3300 V Transformer -2 nos Oil filtration and OLTCs, improve the BDV of oil and test report of Transformer and commissioning of transformers. (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76888/2024-2025:OLTC general servicing, completing the incompleted control circuit wiring & inspection of the contacts & mechanism /RTCC panel etc and commissioning (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76889/2024-2025:63 KVA HV 11000 V / LV – 433 V Transformer – 1 nos Oil filtration and OLTCs, improve the BDV of oil and test report of Transformer No.3 and commissioning (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76890/2024-2025:General servicing and overall cleaning and painting of Transformer (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76891/2024-2025:Transporting charges of oil filtering machine & equipment from Ernakulam to Kasargod Bavikkara Intake well pump house including waiting charge at site (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76892/2024-2025:Hire charges for 82 KVA generator for running oil filtering machine including up and down conveying with Diesel (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76893/2024-2025:Servicing of NGR panel, cleaning, checking and Regeneration of earth pit and making correct earth resistance (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76894/2024-2025:Towards the labour charges for cleaning dust and Servicing of 250 KW /3.3 kv FCMA soft starter Vacuum Contactor power line circuit, air core series reactor coil, and servicing and replacing control circuit wiring destroyed by rats, digital meter, automatic control relays and Servicing 12 kv 630 A starter isolating switch mechanical and contact portions etc and checking giving control volt and commissioning (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76895/2024-2025:Supply of additional Transformer oil for filling empty transformer reservoir including conveyance charge (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76896/2024-2025:Supply of 11 KVA / 110 volt 3 phase epoxy type PT Transformer including conveyance charge (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76897/2024-2025:Supply of 3.3 KVA/ 110 volt 3 phase epoxy type PT Transformer including conveyance charge (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD76898/2024-2025:1Amps 11/12 KV Fuse link for PT Transformer (Special officer Electrical. PRJ(KSD)-15/24/18.07.2024)
OD79031/2024-2025:Supplying and laying of good quality Electrical Insulation Rubber Mat – 11KV / Class B , 12mm Thickness)usually using at electrical substations as per the direction of departmental officers
OD79032/2024-2025:Supplying of good quality electrical resistant gloves
OD79033/2024-2025:Supplying of stand for hooking fire bucket
OD79034/2024-2025:Supplying of fire bucket for fire fighting at pump house and substation at Mottel
OD79035/2024-2025:Supplying of fire extinguisher of 5kg dry chemical powder type for the pump house at Mottel and substation
Appendix 6: Electrical maintenance at Intake well cum pump house at Mottel - Supplying , testing, erecting and commissioning of CT/PT,TOD Meter etc at Intake well cum pump house Mottel
OD76948/2024-2025:11 kV Metering Unit : Supply,erection, testing and commissioning of out door type metering unit consisting of the following accessories: Current Transformer CT Ratio 100/5A Burden 15VA Accuracy Class 0.2S Potential Transformer PT ratio 11KV/110V Burden -100VA. Accuracy Class 0.2 The rate shall include the cost of testing the equipment at KSEB and all other incidental expences. The CT ratio should be fixed only after obtaining the power allocation from KSEB.
OD76951/2024-2025:Supply,erection, testing and commissioning of TOD meter with maximum demand in KVA suitable for the above out door metering set housed in a weather proof out door Kiosk with test terminal block as specified by ksebl and connecting cable from CT PT to TTB & TOD meter.The rate shall include the cost of testing the equipment at KSEB and all other incidental expenses. (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD76952/2024-2025:Supplying, fixing of the 16 A SP MCBs in a suitable size MS enclosure and angle iron frame for controlling street lights. (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD76953/2024-2025:Inspecting the wiring of already installed street lights, making necessary repair works, including fuse and switch housed in weather proof box for street lights in the existing poles/structures. (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD76954/2024-2025:Supplying, fixing of 2 x 36 Watts box type 1200mm LED tube light fittings. (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD76955/2024-2025:Supplying and fixing 1 x 20 W box type1200mm LED tube light fittings (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD76956/2024-2025:Supplying and fixing 100W LED street light in the existing street light fittings (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD76957/2024-2025:Re-Wiring to the Light/Fan points with 3/22 PVC insulated copper conductor along with single run 3/22 PVC insulated copper conductor (Green coulor) drawn inside suitable size PVC conduit pipe with necessary bends, elbows, junction boxes etc. in open conduit system clamped on struss/wall with suitable clamps and saddle clips including supplying and fixing of 5 Amps flush type control switches fixed on existing M.S. box with 3 mm thick hylem sheet cover (excluding the cost of PVC conduit pipe and fittings and MS box) (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD76958/2024-2025:Wiring to the exhaust fan points with 3/22PVC insulated copper conductor alongwith single run 3/22 PVC insulated copper conductor (Green colour) drawn inside suitable size PVC conduit pipe with necessary bends, elbows, junction boxes etc. in open conduit system clamped on struss/wall with suitable clamps and saddle clips including supplying and fixing of 5 Amps flush type control switches fixed on a suitable M.S. box with 3 mm thick hylem sheet cover.(excluding the cost of PVC conduit pipe and fittings and MS box) (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD76959/2024-2025:Supplying and fixing of 1200 mm sweep AC ceiling fan with standard down rod and electronic type regulator. (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD76960/2024-2025:Supplying and fixing of 12" dia single phase light duty 1500 RPM exhaust fan with necessary MS frame work. (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD76961/2024-2025:Preparation of scheme drawing , getting scheme approval , coordinating statutory inspections and getting energization sanction from Electrical Inspectorate and KSEBL (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
Appendix 7: Construction of Operator cabin , toilet, cleaning works etc.
2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22A.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Mild steel and Medium Tensile steel bars
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
50.6.5.1:Hollow block masonry using pre cast blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)
21.2.2:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.37.1:White washing with lime to give an even shade:New work (three or more coats)
13.45.1:Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
11.46.2:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
18.48A: Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.
OD79019/2024-2025:Wiring to the15/20 Amps plug points with 7/22 PVC insulated copper conductor along with single run 3/22 PVC insulated copper conductor (Green colour) drawn inside suitable size PVC conduit pipe with necessary bends, elbows, junction boxes etc. in open conduit system clamped on struss/wall with suitable clamps and saddle clips including supplying and fixing of 5 Amps flush type 3 pin plug control switches fixed on a suitable M.S. box with 3 mm thick hylem sheet cover.
OD79020/2024-2025:Wiring to the 5 Amps plug points with 3/22 PVC insulated copper conductor along with single run 3/22 PVC insulated copper conductor (Green colour) drawn inside suitable size PVC conduit pipe with necessary bends, elbows, junction boxes etc. in open conduit system clamped on struss/wall with suitable clamps and saddle clips including supplying and fixing of 5 Amps flush type 3 pin plug control switches fixed on a suitable M.S. box with 3 mm thick hylem sheet cover.
OD79021/2024-2025:Wiring to the exhaust fan points with 3/22PVC insulated copper conductor alongwith single run 3/22 PVC insulated copper conductor (Green colour) drawn inside suitable size PVC conduit pipe with necessary bends, elbows, junction boxes etc. in open conduit system clamped on struss/wall with suitable clamps and saddle clips including supplying and fixing of 5 Amps flush type control switches fixed on a suitable M.S. box with 3 mm thick hylem sheet cover.
OD79022/2024-2025:Wiring to the Light/Fan points with 3/22 PVC insulated copper conductor along with single run 3/22 PVC insulated copper conductor (Green coulor) drawn inside suitable size PVC conduit pipe with necessary bends, elbows, junction boxes etc. in open conduit system clamped on struss/wall with suitable clamps and saddle clips including supplying and fixing of 5 Amps flush type control switches fixed on a suitable M.S. box with 3 mm thick hylem sheet cover. (Substation & Pump house)
OD79023/2024-2025:Supplying, fixing of 2 x 36 Watts box type 1200mm LED tube light fittings. (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD79024/2024-2025:Supplying and fixing 1 x 20 W box type1200mm LED tube light fittings (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD79025/2024-2025:Supplying and fixing of 1200 mm sweep AC ceiling fan with standard down rod and electronic type regulator. (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
OD79026/2024-2025:Supplying and fixing of 12" dia single phase light duty 1500 RPM exhaust fan with necessary MS frame work. (Special officer Electrical. PRJ(KSD)-16/24/18.07.2024)
17.3.1:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
17.7.2:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
50.18.7.4.2:Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall
50.18.8.9.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2
50.18.7.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall
18.16.2:Providing and fixing brass stop cock of approved quality :20 mm nominal bore
18.17.2:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
OD79028/2024-2025:Engaging coolie for cleaning the pump house and substation building by completely removing all dust and dirt as per the directions of the department officers.
100.60.1.1.2:Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.60.3.1.1:Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers
100.60.10.4.1:Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers.
100.60.12.3.1:Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.
OD79029/2024-2025:KWA water connection charges up to 30m length of service main
OD79030/2024-2025:Supplying and fixing suitable float valve for PVC tank for Operator cabin
OD80515/2024-2025:Providing and fixing Readymade poly ethylene cylindrical horizontal type septic tank with 1200 liters capacity including all cost of materials, erection etc complete.
Repainting of intake well cum pump house and Substation
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
14.46:Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
14.43:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
14.72:Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
14.53.1:Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work
14.54.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work
13.71:Lettering with black Japan pint of approved brand and manufacture
10.29.2:Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
JOSHI
SRI ROYAL ELECTRICALS
Bidder Name
JOSHI
SRI ROYAL ELECTRICALS
M MAHESH
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1064285.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .