Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L1 | Accepted-AOC Awarded contract being lowest | |
| 2 | L2₹34.2 L+₹59,475 (1.77%)Rejected-AOC RP IV 23 PUNNAKADAVU JN RAMANTHALI P O KANNUR 670308 | KANNUR | KANNUR | KERALA | 670308 | L2 | Rejected-AOC Not being lowest | |
| 3 | L3₹36.8 L+₹3.2 L (9.66%)Rejected-AOC 137 D THEJAS BURNASHERRY KANNUR KERALA 670013 | KANNUR | KANNUR | KERALA | 670013 | L3 | Rejected-AOC Not being lowest | |
| 4 | L4₹39.6 L+₹6.0 L (18.0%)Rejected-AOC | L4 | Rejected-AOC Not being lowest | |
| 5 | L5₹42.7 L+₹9.2 L (27.3%)Rejected-AOC 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L5 | Rejected-AOC Not being lowest |
| Sl No | Description | Qty | Unit | PADMANABHAN. K.V L6 | Benchmark Engineers and Contractors L3 | Jack Electrolinks Private Limited L5 | SANDR L2 | Green Ray Enterprises L7 | LAKSHMI BUILDERS L4 | SREEKRUPA ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Note :- 1. The contractor should visit at site before quoating the tender to know the working condition of the station. 2. All requisite safety measures adopted by contractor on site. 3. The contractor shall provide and deploy sufficient electricain ( as aproved by GE / Engineer-in-Charge) shall report at 9:00Hrs to JE E/M or Engineer-in-Charge to collect the complaints card in working days and complete the same complaints within 24Hrs. 4. The complaints shall be rectified within 24hrs if the complaints is/are not attended or not completed within 24hrs (except repairs / replacement of major items) recovery will be done Rs. 500/- per complaint per day. 5. For Major parts like replacement of MCB DB's / MCCB DB's should be rectified within three working days, if the contractor not rectify recovery will be done Rs. 500/- per complaint per day. 6. If contractor fail to provide their electricain to attend the complaints then recovery will be done by Rs. 1000 per day. | ||||||||||
| 2.00 | Taking down carefully copper/ aluminium point wiring (light, fan and power socket etc) complete (except concealed conduit) including fittings such as switches ceiling roses, pendent, regulators, sockets, earth plug and socket etc and making good matching to the existing colour to the disturbed surface. | 160 | Point | 148 ₹23,680 | 20 ₹3,200 | 50 ₹8,000 | 25 ₹4,000 | 10 ₹1,600 Lowest | 100 ₹16,000 | 50 ₹8,000 |
| 3.00Material and Labour colour code point wiring FRLS PVC insulated and sheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade drawn through PVC casing caping with suitable size flush box fitted with modular cover plate with frame (inner/ outer plate) for mounting 6 Amps switch with socket on independent board including FRLS 1.5 sqmm earth wire copper insulated wire connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint all directed at the site Note :- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. | ||||||||||
| 3.01 | (a) One Light/ fan point controlled by one switch | 60 | Point | 650 ₹39,000 | 430 ₹25,800 Lowest | 1,250 ₹75,000 | 900 ₹54,000 | 800 ₹48,000 | 950 ₹57,000 | 800 ₹48,000 |
| 3.02 | (b) One 3 pin socket outlet outlet 5 Amps on the same board with other switches | 5 | Point | 170 ₹850 | 115 ₹575 Lowest | 1,250 ₹6,250 | 130 ₹650 | 200 ₹1,000 | 200 ₹1,000 | 300 ₹1,500 |
| 3.03 | (c) 5 Amps socket point on independent board
Note : Size of copper earth wire must be equal to size of current carrying conductor upto size 16 sqmm. | 35 | Point | 650 ₹22,750 | 435 ₹15,225 Lowest | 1,250 ₹43,750 | 900 ₹31,500 | 840 ₹29,400 | 950 ₹33,250 | 800 ₹28,000 |
| 4.00 | All as per item no 3 here in before but 2.5 sqmm for 15 Amps socket on indipendent board. | 35 | Point | 800 ₹28,000 | 435 ₹15,225 Lowest | 1,400 ₹49,000 | 1,000 ₹35,000 | 900 ₹31,500 | 1,100 ₹38,500 | 900 ₹31,500 |
| 5.00 | All as per item No.3 here in before but 4 sqmm for 16/20 Amps socket on independent board. | 10 | Point | 1,650 ₹16,500 | 520 ₹5,200 Lowest | 1,650 ₹16,500 | 1,450 ₹14,500 | 1,260 ₹12,600 | 1,400 ₹14,000 | 1,000 ₹10,000 |
| 6.00 | All as per item No.3 here in before but One bell/buzzer point controlled by one push button | 15 | Point | 700 ₹10,500 | 420 ₹6,300 Lowest | 1,050 ₹15,750 | 900 ₹13,500 | 920 ₹13,800 | 950 ₹14,250 | 800 ₹12,000 |
| 7.00 | Material and Labour sub main wiring colour coded using 2 runs of 2.5sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through PVC casing caping along with 1 run of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly complete all as specified, including taking down the unserviceable wiring complete all as specified and directed | 350 | RM | 178 ₹62,300 | 410 ₹1,43,500 | 365 ₹1,27,750 | 160 ₹56,000 Lowest | 290 ₹1,01,500 | 180 ₹63,000 | 350 ₹1,22,500 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
3 Jun 2026, 6:55 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2026_MES_764956_1
GE MAINT EZHIMALA 8854
Open Tender
Civil Works
Item Rate
330 days
Ezhimala
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹96,000
Yes
2 Jul 2026
12 May 2026
9 Jun 2026
12 May 2026
3 Jun 2026
27 May 2026
12 May 2026 - 19 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Taking down carefully copper/ aluminium point wiring (light, fan and power socket etc) complete (except concealed conduit) including fittings such as switches ceiling roses, pendent, regulators, sockets, earth plug and socket etc and making good matching to the existing colour to the disturbed surface. | 160 | Point | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.00 MB
Tender8854.pdf
Tender Documents • 1.07 MB
BOQ_856761.xls
BOQ • 1.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .