Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | L1 | Accepted-AOC Accepted by tender Committee |
Tender Value
₹8.7 L
EMD Value
₹13,000
Closing Date
21 Oct 2021, 6:00 pmClosed
The Executive Engineer Electrical HEED Harbor Engi
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram,TVPM
Fisheries-Establishment of live food unit integrated with finfish hatchery at Neyyar-Electrification
2021_HED_445013_1
34/HEED/2021-22/S
Open Tender
Electrical Works
Item Rate
60 days
Neyyar, TVPM
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,350
₹13,000
13 Jan 2022
12 Oct 2021
23 Oct 2021
12 Oct 2021
21 Oct 2021
12 Oct 2021
Amount
Wiring for light point / fan point/ exhaust fan/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required(Group C)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 4.0 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.5 X 4 sq. mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supply and drawing 3 core 1.0 sq.mm multi-core PVC insulated & PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections .
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following size / modules, Plastic boxes alongwith modular base & cover plate for modular switches on surface or in recess etc as required. 3 Module plastic box
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mm X 75mm)
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amp switch
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
Supplying and fixing 16 A SP modular switch with indicator on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Providing and fixing10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply and laying bare earthing copper conductor 10 SWG laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in Ordinary soil).
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. (but without charcoal/ coke and salt) as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and fixing following ways surface / recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, IP 43 , IK 09, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision for MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB's/ MCCB) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4way (4+12) Double door
Supplying and fixing 4 way , Double door horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 12 Way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 8 Way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 6Way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 40A, two pole, (single phase and neutral), 240 volts,Residual current circuit breaker with Overcurrent Protection (RCBO), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40A, two pole, , 240 volts,miniature Change over switch withTwo Way Centre Off in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40A, four pole, (three phase and neutral), 415 volts,Residual current circuit breaker with Overcurrent Protection (RCBO), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supply, conveyance and fixing 40 A, 25 kA (Ics=100%Icu), 3 pole, MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL & SC conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle).
Supply of 50/38mm (OD/ID) Double Walled Corrugated (DWC) pipes made out of HDPE for mechanical protection to under ground power/communication/ OFC / Signal cable conforming to IS 14930 Part - II,
Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metre.
Supply of 4 core 25 sq mm PVC insulated and PVC sheathed armoured aluminium cable
Supply of 4 core 10sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 4 core 6 sq mm PVC insulated and PVC sheathed armoured aluminum Power cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C x 25 sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. upto 4C x 10 sq.mm (25mm)
Supply and providing 25mm pvc gland at the starter box including drilling necessary holes as required
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4 x 25 sq.mm
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
Supplying suspended LED luminaire Philips SM 270 C LED 30S - 6500 PSU WH or equivalent
Supply of recessed mounted 250mm x 250mm LED luminaire DN 097B LED 10S - 6500 PSU WH PHILIPS or equivalent .
Supplying LED luminaire Philips WT 201 C LED 20S - 6500 PSU L 120 IP 65 or equivalent
Supplying 16 W LED Tube with box type fixtures Essential LED tube 1200 mm 16W 865 T8 API Philips or equivalent
Supply and fixing 7W LED lamp OSRAM / Philips or equivalent
Supplying Keselec Schreder make Street light luminaire 20W LED, an IP66 optical & control gear compartment, a die cast aluminium painted housing, Polycarbonate protector with in built lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy > 90 Lumen/W at Ta 25⁰C. Lifetime residual flux @ Tq 35⁰C @ 50,000 hours = 70%, Ta = 50⁰C, in built surge protection of 4kV (in Differential and Common mode), Power Factor > 0.95, Colour Rendering Index > 70 and Cool white light (5700⁰K) or equivalent
Supply and fixing straight / Angle batten holder including connection etc as required
Supply and fixing 88x 20mm PVC round block on the existing steel structure
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for LED Lamps including connection etc as required.
Supply of ceiling fans of 1200 mm sweep Category B Ceiling fan excluding resistance type regulator
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
Supply of single phase , 230V ,90W,1400 rpm, 305 mm sweep heavy duty exhaust fan with louvres ( Almonard or equivalent) in metal frame Category B ,
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Supplying and fixing extra conduit down rod of 1m length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Engaging Electrician for repairs of electrics at Electrical room, Cubicle and dismantling fittings
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring etc as required
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).40 mm dia with clamps made from 20 x 3 mm MS flat
Providing and fixing 50 mm dia nominal bore B class G.I. pipes with ISI mark complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Supply and fixing DOL Starter in sheet steel enclosure L&T make or equivalent switch type , 230V, 1 Ph, Thermal Relay range for 0.5/1.0 HP motor
Supplying, fabricating , erecting and commissioning wall mounting, dust and vermin proof cubicle BLOWER panel board of size 1200x750x250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality synthetic enamel paint over a coat of epoxy primer, having separate hinged door and quarter turn key lock covers for incomers and outgoing and power capacitor and front openable bolted type door for wireway box with cable entry provisions , terminal block using 20 A Elmex connector for taking out the supply to the motor, bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top and bottom . Incoming:- 50A, 25kA FP MCCB setted to 40 A and rotory drive kit including BUC handle- 1No outgoing-32A, 25kA,TP MCCB, complete with rotory handle - 2 Nos panel surface mounting 96mm square 3 line LED type Multifuntion meter with V,I and frequency measurement(vif) socomec or equivalent suitable for 230 ac 50Hz-1 Nos 32A two way disconnectable type neutral link-2 Nos 2A single pole MCB (C curve) - 9 Nos 16mm dia LED type Phase indication lamp-Red and Yellow - 4 Nos 16mm dia LED type Phase indication lamp- Green - 2Nos 16mm dia LED type Phase indication lamp Blue colour-1No 30/5,5VA, metering tapewound C.T of accuracy class 1- 3Nos Legend Plate Danger,415V ,100x75mm , MOTOR start and run - 2Nos Busbar Chamber: Busbar chamber with 25X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the incoming and is also to be carried out using 25x3mm PVC insulated Copper strips supported using epoxy insulators and outgoing with suitable rated copper conductor as required. 415V ,9A, 3 pole contactor AC-3 duty with 1NO+1NC contactor-2 Nos ,MPR 302BE 040 L&T make motor protection Relay- 2 Nos 20A 415V AC ELMEX Connecter DIN Rail - 9 Nos 3 phase,415V, 1 KVAR, ISI marked Power factor improvement Capacitor with test certificate (MR) 25 A,415V,50Hz Push button unit ON and OFF - 2 set All MCCBs shall be Ics= 100% Icu.The components should be wired using 4sq.mm PVC insulated copper wire and terminations for input and output will be done using 20A Elmex Connector.
Supply of 1.5 Tonne,230V,ac,50Hz single phase 5 star rated (2021) full copper highwall split Inverter Air conditioner . Preffered make of (Voltas/Carrier/LLoyd) with cordless remote
Supply, Testing and commissioning of Wall hanging type Voltage stabilizer of Single phase 230V, ac, 50Hz ,4000 VA suitable for 170 to 260V input voltage range preferred make of V-GUARD/ MICROTEK for 1.5 T AC
Installation Testing and commissioning of 1 to 1.5 Tonne departmentallly supplied split type air conditioning unit in suitable location
Supplying suitable clamp for outdoor unit of AC
Supply, installation, testing and commissioning of 230V AC. 50HZ , 2 KVA,24V DC inverter having digital frequency control circuit with on load automatic changeover from mains to inverter circuit on mains failure and vice versa on restoration of mains supply . The unit shall have an in-built battery charger with solar charging option of suitable capacity having automatic cut off circuit on battery attaining full charge . The unit should also have overload trip with audio visual indication & automatic reset on removal of overload, LED indication for Mains ON, charging ON, Overload Trip & inverter ON and Output ON/OFF switch on the front panel .Preferred make LUMINOUS / APC /MICROTEK with suitable battery rack for tubular batteries.
Supply and installation of Inverter battery 12V 100 Ah tubular type conforming to ISO 9001:2008 and ISO 14001:2004 suitable for 3hours backup on full load .Preferred make of EXIDE /AMARON
Supply and fixing Philips/wipro/Osram or equivalent batten LED tube 600mm 10W and fixtures etc complete.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_634185.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .