Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.0 LAccepted-AOC D NO 39 33 88 2 PLOT NO MIG 208 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | 1 | Accepted-AOC ACCEPTED BEING THE LOWEST TENDERER | |
| 2 | 2₹14.3 L+₹2.3 L (19.4%)Rejected-Finance DOOR NO 39 33 62 1 4 PLOT NO MIG 95 96 SAMYAM ENCLAVE FLAT NO 101 VUDA COLONY MADHAVADHARA MARRIPALEM POST VISAKHAPATNAM 530 018 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530018 | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
4 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I CG VIZAG
AGE (I) (CG) Vizag, Military Engineer Services, CGWO Building C/o Fleet Mail Office,Visakhapatnam 14
PROVISION OF GRILLED DOORS AND ACCOMODATION FOR RIFLE FOR DSC ARMOURY AND SENTRY BOXES FOR DSC AT OLD DHQ6 COMPLEX COAST GUARD JETTY VISAKHAPATNAM
2022_MES_530417_1
AGE(I)CG/VIZ/TOKEN 16 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE (I) (CG) VIZAG
₹30,000
Yes
1 Sept 2022
13 Jun 2022
6 Jul 2022
13 Jun 2022
4 Jul 2022
20 Jun 2022
60 days
Amount
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
M & L for plain cement concrete 1:4:8 type B-1 , (using 40 mm graded stone aggregate) in foundation complete all as specified and as directed.
M & L for plain cement concrete 1:2:4 type B-1 , (using 20 mm graded stone aggregate) in foundation complete all as specified and as directed.
M&L for rolled mild steel in Plates ( plain or chequered, Fe 410 -W (Gde-E- 250 ) quality- A) channels . Square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed.
S & F rolled mild steel in Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) complete all as specified and as directed.
S & F rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides fixed with angle cleats or other connecting plates etc. complete all as specified and directed.
S&F mild steel as in roof trusses (Framed), trusses, purlins, bracket, base plate including distance pices cleat etc. complete all as specified and as directed.
S&F Mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screw both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30 cm long dia exc 12 but n exc 20 mm complete all as specified and as diretced.
M&L for preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of coptic green/synthetic enamel paint over a coat of red oxide complete all as specified and as directed. Make: Shalimar Paints Ltd. [Superlac] / Asian [Apcolite] / Berger [Luxol] / Jenson & Nicholson Paints Ltd [Brolac] / Jotun India Pvt Ltd
M&L for Mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed.
S& F Pre-painted galvalume aluminum zinc coating trapizoidal profile sheet of 0.50 mm thick [TCT] of any having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. Make: M/s TATA BLUE SCOPE, M/s LLOYD INSULATIONS INDIA LTD, M/s BUILD TECH / M/s. Jindal
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. Make: M/s TATA BLUE SCOPE, M/s LLOYD INSULATIONS INDIA LTD, M/s. BUILD TECH / M/s. Jindal
S&F 1 mm thick Plain, black mild steel sheeting in stepped flashings (measured as the minimum rectangle from which the pieces can be cut) complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L for Brick work with fly ash bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement including mixing with WPC all as per manufacturers instructions complete. (Note:- WPC will be measured and paid separately)
Supply only integral Water proofing compound.
M&L for preparing newly plastered surfaces and applying two coats of cement base paint on surfaces of walls complete all as specified and as directed. Make: Snowcem Plus / Berger / Asian Paints [Gutucam] / Jotun India Pvt Ltd / Crimocem Super Cement Paints
Surface excavation in soft / loose soil n exc 30 cm deep and averaging 15 cm deep and getting out complete all as specified and as directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection finished even and smooth with using extra cement complete all as specified and as directed.
M&L for 100 mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing complete all as specified and as directed.
M&L for 60 mm thick Machine pressed precast concrete interlocking paver blocks of any shape and size confirming to IS 15658 - 2006 of , M-35 grade with grey cement and no pigment complete all as specified and as directed. Make : Ultra tiles Pvt. Ltd/Terra firma/Ecco Scope/ Mehtab tiles/ Bharat Tiles & Marble Pvt Ltd / National Tiles & Industries Pvt Ltd / Nitco Tiles Pvt Ltd / Nimco Tiles / Metro Tiles Bombay / Vitco Tiles Bombay / Anjali tiles
M & L for Sand filling under floors or in foundations including watering as required.
M&L chequered designed cement concrete tiles of size 300mm x 300 mm x 20 mm thick, with grey cement and pigment set, jointed and pointed in neat cement slurry in floors including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor tiles complete all as specified and as directed.
Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) not exc 1.5 sqm each and removing from site of work complete all as specified and as directed.
Demolition of Brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles
Supply, laying and testing of 4 core 16 sq mm XLPE cable insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed. Make-KEI/Polycab/Havells / Gloster Cables / KEI Industries Ltd / Polycab / Asian Cables / Finolex
S&F double door metallic sheet metal enclosure for DB when MCBs to be used SPN 2 ways, 230 V complete fixed properly in concealed position on wall and suface position on trusses and to provide required sizes of flexible conduit at any open surfaces near DBs of cables / wires including providing of suitable size of lugs and blanking plate complete all as specified and as directed. Make-Legrand/Schneider/L&T
S&F testing and commissioning of MCB SPN 240 volt 6 Amp to 32 amp 10 KA capacity having C - Curve characteristics connected with suitable lugs complete all as specified and as directed. Make - Legrand/Scheinder/L&T
M&L for sub main wiring on surface with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in MS / PVC conduit with 4.0 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete excluding rigid stove enameled steel conduit (ISI marked) of size not less than 20 mm dia in concealed / surface wiring inclusive all fittings such as Tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc. fixed properly including taking down old unserviceable sub main wiring complete. Make of wire: Polycab/Havells /Finolex/KEI
M & L for Modular concealed point wiring on wall and ceiling / roof etc. with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade conforming to IS 694 drawn in and including rigid non metallic white / ivory PVC conduit medium grade (ISI marked) not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc. including anodized Modular sunken boxes made out of MS sheet of standard thickness with earth dolly and crown plate and cover plate for fixing of modular switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc. with captive MS screw including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of Paris / Putty or distemper / Colour wash with same existing colour surfaces complete all as specified and as directed by Engineer-in-Charge for the following:- For one light, fan , 5 Amp independent socket point controlled by one switch.
All as per Item No. 32 but for One 3 pin socket outlet. 15 amps, independent, with cables 4 sq. mm size
S&F for Modular switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified and as directed. Make-Anchor/Havells/Legrand/Scneider
S&F for Modular switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and as directed.. Make-Anchor/Havells/Legrand/Scneider
S&F Modular socket outlet 5 pin, 5 Amps flush type white finish complete all as specified and as directed. Make-Anchor/Havells/Legrand/Scneider
S&F Modular socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified and as directed. Make-Anchor/Havells/Legrand/Scneider
S&F ceiling rose, surface backlite, 65 x 20 mm three terminal complete all as specified and as directed.
S & F Wall mounted fan oscillating type 60 W 400 mm sweep,1350 RPM, 230 volts,single phase complete all as specified and as directed. Make- Havells/Khaitan/Bajaj/Crompton or equivalent as specified in PS
S & F LED Security light with high energy saving LED, powder coated pressure die cast aluminium housing specially designed specular anodized super high purity, faceted alumnium reflector of size 30 Watt 230 volts IP 65 complete all as specified and as directed. Make-Havells/Philips/Bajaj or equivalent as specified in PS
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification.
S & F LED lights fitting 1 x 20 W, 220 V, AC decorative box type with driver, holder, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make :- Philips/Bajaj/Havells or equivalent approved by AGE (I) (CG) Vizag
M&L for concealed point wiring with PVC insulated, PVC unsheathed FRLS cable 1100 V grade , single core, stranded, copper conductor cable 1.5 sqmm size, drawn into including 1.6 mm thick ERW steel surface conduit (ISI marked) conforming to IS 9537(Part-II) of size not less than 25 mm dia including fameproof fittings such as juntion box LM6, MS coupling unions bends,reducers inspection elbow,sealing conduits plugs etc and including signle core stranded copper conductor 1.5 sqmm PVC insulated unsheathed cable stranded copper cable (green insulation) for continuous earth wire and including pressed steel concealed terminal boxes of required size of 2 mm thick, covered with 3 mm thick plastic laminated bakalite sheet, ISI marked all as directed for light,fan. Note : Wire to be done through Steel surface conduit in walls in roof / wall for flame proof wiring.
S & F LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. Make-Philips/Bajaj/Havells or equivalent approved by AGE (I) (CG) Vizag
S & F Exhaust Fan 18 inch 457 mm sweep CFM 4000, 0.50 HP single phase 230 Volts with louvers including fixing arrangement complete all as specified and as directed. Make: Crompton Greaves / Havells / Almonard / Bajaj / Orient / Ram Ratna Electrical Ltd or equivalent as specified in PS
S & F Flame proof weather proof rotary switch with cable terminal box in cast aluminium alloy (LM-6) construction, epoxy powder coated, single pole 16 Amp ON-OFF type 230 V AC certified by CMRS for group II A & II B complete including compression glands all as specified and directed
Supply and fix Junction box LM6 dia 100 x 65 H complete all as specified and as directed.
S&F FLP-WP double door metallic sheet metal enclosure for DB when MCBs to be used SPN 4 ways, 230 V IP 54 protection and outgoing in cast aluminium alloy (LM-6) construction epoxy powder coated suitable for IP-55 Protection and group IIA and IIB as per IS 2418 and certified by CMRI fixed fixed properly on in concealed position on wall and surface position on trusses and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires including provision of suitable size of lugs and blanking plate complete all as specified and as directed. Make - Legrand / L & T [Hager] / Siemens / ABB / Schneider / GE / C & S or equivalent as specified in PS
S&F testing and commissioning of FLP/WP MCB SPN 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and as diretced. Make :- Legrand / L & T [Hager] / Siemens / ABB / Schneider / GE / C & S or equivalent as specified in PS.
S & F testing and commissioning of FLP/WP MCB SP 240 volt 6 Amp to 32 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and as directed. Make - Legrand / L & T [Hager] / Siemens / ABB / Schneider / GE / C & S or equivalent as specified in PS
VIJAY VINAYAKA INFRA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .