Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹42.7 L+₹2.3 L (5.78%)Rejected-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹43.6 L+₹3.3 L (8.07%)Rejected-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹44.8 L+₹4.4 L (11.0%)Rejected-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-AOC REJECTED | |
| 5 | Rejected-Technical PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | - | Rejected-Technical REF TECHNICAL EVALUATION DOCUMENT |
Tender Value
Refer Docs
EMD Value
₹79,000
Closing Date
6 Apr 2022, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
SPECIAL REPAIR FOR REPLACEMENT OF LT PANELS AND CONNECTED ITEMS AT CGDHQ NO. 1 PORBANDAR UNDER GE I CG PORBANDAR
2022_MES_514098_1
8724
Open Tender
Electrical and Maintenance Works
Works
180 days
Porbandar
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE I CG PORBANDAR
₹79,000
Yes
7 May 2022
17 Mar 2022
7 Apr 2022
17 Mar 2022
6 Apr 2022
31 Mar 2022
17 Mar 2022 - 30 Mar 2022
Amount
SCHEDULE 'A'
Supply , Installation & commissioning of factory made, CPRI approved manufacturer, self supporting totally enclosed LT Panel Board (out door type) confirming to IP-55 ,compartmentalized design, dust & vermin proof for 440 Volt 3 phase 4 wire system madeup of GI sheet of 3.0 mm thick built upin rigid frame work having front and rear hinged door with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip point and ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. having control circuit diagram with colour code solid conductor copper 1.5 sqmm cable for easy identification including Incoming/ Outgoing cable entry provisions, embeded with 50x6mm mild steel angle Iron frame and 200 mm above the normal ground level complete with PCC foundation in cement concrete 1:2:4 (20mm graded stone aggregate) and testing after installation including taking down unserviceable LT panel board complete all as specified and comprising with the following :- Make : Legrand( sigma control systems)/BCH/SIEMENS / C&S (ASENT Engineers)
(a) Copper Bus Bar of size 25x4 mm , rating 600 Amps, supported with suitable size of heavy duty porcelain standblock with suitable size brass nut, bolts and washers with heat shinkable PVC sleeving. The Bus Bar shall be colour coded (Red, Yellow & blue) for 3 phase and Black for Neutral .
(b) MCCB TPN, 400 Amps, 4 Pole, 415 Volt, 36 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos.Make
© MCCB TPN, 200 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 06 Nos.
(d) MCCB TPN, 100 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 2 Nos .
(g) LED Indicating Lamps ( 03 Nos) with holder for main supply indicating RYB - 01 set.
(j) Timer switch 0-24 Hours for automatic operation single phase, Micro Rex QT 11 250 V AC, 50 Hz - 01 No.
M & L for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, 4 wire +E, fabricated Polycarbonate, RAL 7035 finish confirming to IP 65 complete including Cu bus bar 400 Amps, 30 KA, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following :- Make: Hensel or equivalent SIEMENS/ HAGER
(a) Copper Bus Bar of rating 400 Amps, supported with suitable size of heavy duty porcelain standblock with suitable size brass nut, bolts and washers with heat shinkable PVC sleeving. The Bus Bar shall be colour coded (Red, Yellow & blue) for 3 phase and Black for Neutral .
(b) MCCB TPN, 250 Amps, 4 Pole, 415 Volt, 36 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos. Make : ABB/Legrand/Schnieder.
(c) MCCB TPN, 200 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 3 Nos .
(d) MCCB TPN, 100 Amps, 415 Volt, 16 KA breaking capacity duly connected with bus bar as Out going - 1 Nos .
(g) LED Indicating Lamps ( 03 Nos) with holder for main supply indicating RYB - 01 set.
M & L for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, 4 wire +E, fabricated Polycarbonate, RAL 7035 finish confirming to IP 65 complete including Cu bus bar 600 Amps, 30 KA, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following :- Make: Hensel or equivalent SIEMENS/ HAGER
(a) Copper Bus Bar of rating 600 Amps, supported with suitable size of heavy duty porcelain standblock with suitable size brass nut, bolts and washers with heat shinkable PVC sleeving. The Bus Bar shall be colour coded (Red, Yellow & blue) for 3 phase and Black for Neutral .
(b) MCCB TPN, 400 Amps, 4 Pole, 415 Volt, 36 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos.Make : ABB/Legrand/Schnieder
© MCCB TPN, 250 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 01 Nos.
(d) MCCB TPN, 160 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 01 Nos.
(e) MCCB TP, 100 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 01 Nos.
(h) LED Indicating Lamps ( 03 Nos) with holder for main supply indicating RYB - 01 set.
Supply , Installation & commissioning of factory made, CPRI approved manufacturer, self supporting totally enclosed LT Panel Board (out door type) confirming to IP-55 ,compartmentalized design, dust & vermin proof for 440 Volt 3 phase 4 wire system madeup of GI sheet of 3.0 mm thick built upin rigid frame work having front and rear hinged door with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip point and ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. having control circuit diagram with colour code solid conductor copper 1.5 sqmm cable for easy identification including Incoming/ Outgoing cable entry provisions, embeded with 50x6mm mild steel angle Iron frame and 200 mm above the normal ground level complete with PCC foundation in cement concrete 1:2:4 (20mm graded stone aggregate) and testing after installation including taking down unserviceable LT panel board complete all as specified and comprising with the following :- Make : Legrand (sigma control systems) / BCH / C&S (ASENT Engineers)
(a) Aluminium Bus Bar of rating 400 Amps, supported with suitable size of heavy duty porcelain standblock with suitable size brass nut, bolts and washers with heat shinkable PVC sleeving. The Bus Bar shall be colour coded (Red, Yellow & blue) for 3 phase and Black for Neutral .
(b) MCCB TPN, 250 Amps, 415 Volt, 36 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos.
© MCCB TPN, 100 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 04 Nos.
(f) LED Indicating Lamps ( 03 Nos) with holder for main supply indicating RYB - 01 set.
Note : 1. All Internal Connections shall be connected by Aluminium strip of suitable size and Capacity to MCCB for which cost of the same shall deem to be inclided in the QUOTED UNIT RATE.
M & L for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, 4 wire +E, fabricated Polycarbonate, RAL 7035 finish confirming to IP 65 complete including Cu bus bar 600 Amps, 30 KA, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following :- Make: Hensel or equivalent SIEMENS/ HAGER
(a) Aluminium Bus Bar of rating 600 Amps, supported with suitable size of heavy duty porcelain standblock with suitable size brass nut, bolts and washers with heat shinkable PVC sleeving. The Bus Bar shall be colour coded (Red, Yellow & blue) for 3 phase and Black for Neutral .
(b) MCCB TPN, 630 Amps, 415 Volt, 36 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos. Make : ABB/Legrand/Schnieder
(c) MCCB TP, 100 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 03 Nos.
(f) LED Indicating Lamps ( 03 Nos) with holder for main supply indicating RYB - 01 set.
Note For srl Item No : 2,3 & 5 1. The cost demolition and provision of new PCC foundation as per OEM specification is deemed to be included in the quoted rate 2. Neccessary permission and back up arrangement to be provisioned by the contractor prior to the start of the work
Supply , Installation & commissioning of factory made, CPRI approved manufacturer, self supporting totally enclosed LT Panel Board (out door type) confirming to IP-55 ,compartmentalized design, dust & vermin proof for 440 Volt 3 phase 4 wire system madeup of GI sheet of 3.0 mm thick built upin rigid frame work having front and rear hinged door with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip point and ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. having control circuit diagram with colour code solid conductor copper 1.5 sqmm cable for easy identification including Incoming/ Outgoing cable entry provisions, embeded with 50x6mm mild steel angle Iron frame and 200 mm above the normal ground level complete with PCC foundation in cement concrete 1:2:4 (20mm graded stone aggregate) and testing after installation including taking down unserviceable LT panel board complete all as specified and comprising with the following :- Make : Legrand( sigma control systems)/BCH/ C&S (ASENT Engineers)
(a) Aluminium Bus Bar of size rating 600 Amps, supported with suitable size of heavy duty porcelain standblock with suitable size brass nut, bolts and washers with heat shinkable PVC sleeving. The Bus Bar shall be colour coded (Red, Yellow & blue) for 3 phase and Black for Neutral .
(b) MCCB TPN, 400 Amps, 415 Volt, 36 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos.
© MCCB TPN, 250 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 01
(d) MCCB TPN, 100 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 02
(e) MCCB TPN, 125 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 01
(f) MCCB TPN, 63 Amps, 415 Volt, 16 KA breaking capacity duly connected with bus bar as Out going - 1
(g) MCB TPN, 32 Amps, 415 Volt, 10 KA breaking capacity duly connected with bus bar as Out going - 2 Nos .
(k) LED Indicating Lamps ( 03 Nos) with holder for main supply indicating RYB - 01 set.
(m) Timer switch 0-24 Hours for automatic operation single phase, Micro Rex QT 11 250 V AC, 50 Hz - 01 No.
Supply , Installation & commissioning of factory made, CPRI approved manufacturer, self supporting totally enclosed LT Panel Board (out door type) confirming to IP-55 ,compartmentalized design, dust & vermin proof for 440 Volt 3 phase 4 wire system madeup of GI sheet of 3.0 mm thick built upin rigid frame work having front and rear hinged door with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip point and ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. having control circuit diagram with colour code solid conductor copper 1.5 sqmm cable for easy identification including Incoming/ Outgoing cable entry provisions, embeded with 50x6mm mild steel angle Iron frame and 200 mm above the normal ground level complete with PCC foundation in cement concrete 1:2:4 (20mm graded stone aggregate) and testing after installation including taking down unserviceable LT panel board complete all as specified and comprising with the following :- Make : Legrand( sigma control systems)/BCH/C&S (ASENT Engineers)
(a) Aluminium Bus Bar of rating 400 Amps, supported with suitable size of heavy duty porcelain standblock with suitable size brass nut, bolts and washers with heat shinkable PVC sleeving. The Bus Bar shall be colour coded (Red, Yellow & blue) for 3 phase and Black for Neutral .
(b) MCCB TPN, 250 Amps, 4 Pole, 415 Volt, 36 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos.
© MCCB TPN, 200 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 1 Nos.
© MCCB TPN, 100 Amps, 415 Volt, 25 KA breaking capacity duly connected with bus bar as Out going - 2 Nos.
(d) MCCB TPN, 63 Amps, 415 Volt, 16 KA breaking capacity duly connected with bus bar as Out going - 2 Nos .
(g) LED Indicating Lamps ( 03 Nos) with holder for main supply indicating RYB - 01 set.
Note : 1. All Internal Connections shall be connected by Aluminium strip of suitable size and Capacity to MCCB for which cost of the same shall deem to be inclided in the QUOTED UNIT RATE.
Supply , Installation & commissioning of factory made, CPRI approved manufacturer, self supporting totally enclosed LT Panel Board (out door type) confirming to IP-55 ,compartmentalized design, dust & vermin proof for 440 Volt 3 phase 4 wire system madeup of GI sheet of 3.0 mm thick built upin rigid frame work having front and rear hinged door with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip point and ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. having control circuit diagram with colour code solid conductor copper 1.5 sqmm cable for easy identification including Incoming/ Outgoing cable entry provisions, embeded with 50x6mm mild steel angle Iron frame and 200 mm above the normal ground level complete with PCC foundation in cement concrete 1:2:4 (20mm graded stone aggregate) and testing after installation including taking down unserviceable LT panel board complete all as specified and comprising with the following :- Make : Legrand( sigma control systems)/BCH/C&S (ASENT Engineers)
(a) Aluminium Bus Bar of rating 400 Amps, supported with suitable size of heavy duty porcelain standblock with suitable size brass nut, bolts and washers with heat shinkable PVC sleeving. The Bus Bar shall be colour coded (Red, Yellow & blue) for 3 phase and Black for Neutral .
(b) MCCB TPN, 200 Amps, 415 Volt, 36 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos.
© MCCB TPN, 63 Amps, 415 Volt, 16 KA breaking capacity duly connected with bus bar as Out going - 04 Nos.
(g) LED Indicating Lamps ( 03 Nos) with holder for main supply indicating RYB - 01 set.
Note : 1. All Internal Connections shall be connected by Aluminium strip of suitable size and Capacity to MCCB for which cost of the same shall deem to be inclided in the QUOTED UNIT RATE.
Supply , Installation & commissioning of factory made, CPRI approved manufacturer, self supporting totally enclosed LT Panel Board (out door type) confirming to IP-55 ,compartmentalized design, dust & vermin proof for 440 Volt 3 phase 4 wire system madeup of GI sheet of 3.0 mm thick built upin rigid frame work having front and rear hinged door with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip point and ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. having control circuit diagram with colour code solid conductor copper 1.5 sqmm cable for easy identification including Incoming/ Outgoing cable entry provisions, embeded with 50x6mm mild steel angle Iron frame and 200 mm above the normal ground level complete with PCC foundation in cement concrete 1:2:4 (20mm graded stone aggregate) and testing after installation including taking down unserviceable LT panel board complete all as specified and comprising with the following :- Make : Legrand( sigma control systems)/BCH/C&S (ASENT Engineers)
(a) Aluminium Bus Bar of rating 400 Amps, supported with suitable size of heavy duty porcelain standblock with suitable size brass nut, bolts and washers with heat shinkable PVC sleeving. The Bus Bar shall be colour coded (Red, Yellow & blue) for 3 phase and Black for Neutral.
(b) MCCB FP, 250 Amps, 415 Volt, 36 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos.
© MCCB FP, 63 Amps, 415 Volt, 16 KA breaking capacity duly connected with bus bar as Out going - 06 Nos.
(d) MCB SPN, 40 Amps, 230 Volt, 10 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos.Make : ABB/Legrand/Schnieder
(d) MCB SPN, 32 Amps, 230 Volt, 10 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos.Make : ABB/Legrand/Schnieder
(d) MCB SPN, 20 Amps, 230 Volt, 10 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos.Make : ABB/Legrand/Schnieder
(g) LED Indicating Lamps ( 03 Nos) with holder for main supply indicating RYB - 01 set.
Supply , Installation & commissioning of factory made, CPRI approved manufacturer, self supporting totally enclosed LT Panel Board (out door type) confirming to IP-55 ,compartmentalized design, dust & vermin proof for 440 Volt 3 phase 4 wire system madeup of GI sheet of 3.0 mm thick built upin rigid frame work having front and rear hinged door with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip point and ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. having control circuit diagram with colour code solid conductor copper 1.5 sqmm cable for easy identification including Incoming/ Outgoing cable entry provisions, embeded with 50x6mm mild steel angle Iron frame and 200 mm above the normal ground level complete with PCC foundation in cement concrete 1:2:4 (20mm graded stone aggregate) and testing after installation including taking down unserviceable LT panel board complete all as specified and comprising with the following :- Make : Legrand( sigma control systems)/BCH/C&S (ASENT Engineers)
(a) Aluminium Bus Bar of rating 400 Amps, supported with suitable size of heavy duty porcelain standblock with suitable size brass nut, bolts and washers with heat shinkable PVC sleeving. The Bus Bar shall be colour coded (Red, Yellow & blue) for 3 phase and Black for Neutral .
(b) MCCB FP, 250 Amps, 415 Volt, 36 KA braking capacity duly connected to bus bar as INCOMING - 1 Nos.Make : ABB/Legrand/Schnieder
© MCCB FP, 63 Amps, 415 Volt, 16 KA breaking capacity duly connected with bus bar as Out going - 10 Nos.
(g) LED Indicating Lamps ( 03 Nos) with holder for main supply indicating RYB - 01 set.
Note For srl Item No : 1,4,6,7,8,9 & 10 1: Make for MCB & MCCB will be same as per the make of the panel manufaturer for type tested panel 2. The cost demolition and provision of new PCC foundation as per OEM specification is deemed to be included in the quoted rate 3. Neccessary permission and back up arrangement to be provisioned by the contractor prior to the start of the work
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed. Make : Polycab/Havells/RR Kabel
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed. Make : Polycab/Havells/RR Kabel
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil and including taking out of PCC cable cover and getting out complete all as specified and directed
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply and Lay in replacment of OD 50mm Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings laid in trenches / road / nallah or fixed along wall poles or laid under floor for the following dia
Supply and Lay in replacment of OD 63mm Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings laid in trenches / road / nallah or fixed along wall poles or laid under floor for the following dia
Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion.
SURESH ELECTRICALS
M/s SK Traders
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .