| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 CrAccepted-AOC 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹19.5 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹20.2 CrRejected-Finance | ₹20.2 Cr | L2 | Rejected-Finance other than lowest |
| 3 | L3₹22.5 CrRejected-Finance | ₹22.5 Cr | L3 | Rejected-Finance other than lowest |
| 4 | L4₹23.3 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹23.3 Cr | L4 | Rejected-Finance other than lowest |
| 5 | L5₹23.8 CrRejected-Finance | ₹23.8 Cr | L5 | Rejected-Finance other than lowest |
Tender Value
₹20.3 Cr
EMD Value
₹13.4 L
Closing Date
13 Feb 2023, 6:00 pmClosed
CHIEF ENGINEER NAVY VISAKHAPATNAM
Chief Engineer Navy Station Road Visakhapatnam 530004
PROVISION OF DEFICIENT IN-LIVING ACCOMMODATION (46 NOs) FOR OFFICERS AT VISAKHAPATNAM
2022_MES_565361_1
85412
Open Tender
Civil Works
780 days
GARRISON ENGINEER P N VISAKHAPATNAM
As per tender
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (P) N VISAKHAPATNAM
₹13.4 L
Yes
13 Mar 2023
25 Nov 2022
15 Feb 2023
25 Nov 2022
13 Feb 2023
3 Feb 2023
25 Nov 2022 - 23 Dec 2022
Amount
SCHEDULE 'A' PART-I to SCHEDULE 'A' PART-XIII: Note: Schedule 'A' Part-I to Part-XIV are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 6 only.
Lump Sum price worked out by the contractor for 'Buildings & Structures' as listed in Schedule 'A' Part-I.
Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation as listed in Schedule 'A' Part-II.
Lump Sum price worked out by the contractor for 'Pile Foundation' as listed in Schedule 'A' Part-III.
Lump Sum price worked out by the contractor for 'Internal Water Supply' as listed in Schedule 'A' Part-IV.
Lump Sum price worked out by the contractor for 'Internal Electrification' as listed in Schedule 'A' Part-V.
Lump Sum price worked out by the contractor for 'External Water Supply' as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for 'External Electrification' as listed in Schedule 'A' Part-VII.
Lump Sum price worked out by the contractor for 'Area Drainage' as listed in Schedule 'A' Part-VIII.
Lump Sum price worked out by the contractor for 'Sewage Disposal' as listed in Schedule 'A' Part-IX.
Lump Sum price worked out by the contractor for 'Lightening Protection' as listed in Schedule 'A' Part-X.
Lump Sum price worked out by the contractor for 'Road/Path/Culvert', as listed in Schedule 'A' Part-XI.
Lump Sum price worked out by the contractor for 'Fire Fighting System' as listed in Schedule 'A' Part-XII.
Lump Sum price worked out by the contractor for 'Fire Alarm' as listed in Schedule 'A' Part-XIII.
SCHEDULE 'A' PART-XIV (MISCELLANEOUS ITEMS): (PILE FOUNDATION, INTERNAL WATER SUPPLY, INTERNAL ELECTRIFICATION, EXTERNAL WATER SUPPLY, EXTERNAL ELECTRIFICATION, SOLAR POWER INVERTER, FIRE FIGHTING SYSTEM, FIRE ALARM, AVIATION LIGHT, LIGHTING PROTECTION, DG SET, LIFTS, AND DEMOLITION & DISMANTLING):
PILE FOUNDATION
Boring for bored cast-in-situ piles 500mm dia. in SDR/any type of rock and getting and disposal of spoil out side MD land using Hydraulic/DMC system of boring method complete all as specified and as directed.
Boring for bored cast-in-situ piles 500mm dia. in any strata except SDR/hard rock and getting and disposal of spoil out side MD land using Hydraulic/DMC system of boring method complete all as specified and as directed.
Carrying out initial load [Compression] test on 500mm dia. pile complete all as specified and as directed.
Carrying out initial load [Lateral] test on 500mm dia. pile complete all as specified and as directed.
Carrying out Routine load [Compression] test on 500mm dia. pile complete all as specified and as directed.
Carrying out Routine load [Lateral] test on 500mm dia. pile complete all as specified and as directed.
Carrying out low strain integrity test on cast in situ piles 500mm dia. including analysing the result as per ASTM D 5882 complete all as specified and as directed.
SITE CLEARANCE/AREA DEVELOPMENT/EARTH WORK/EXCAVATION
Removal of excavated surplus soil outside MD Land complete all as specified and as directed.
AREA DRAINAGE
Material and Labour for Factory made SFRC square cover slab for drain cover complete all as specified
SEWAGE DISPOSAL
Material and labour for SFRC factory made manhole cover of size 900 x 900 x 100 mm square shape complete all as specified.
INTERNAL WATER SUPPLY:
Supply and Fixing MS ERW pipe heavy duty on wall/roof top 80mm bore including all fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc. fixed to walls and ceilings or laid in floors and including necessary welding for marking necessary tappings etc. complete all as specified and as directed.
Supply and Fixing 15 mm dia bib tap long body, fancy type, chromium plated, screwed down and fixed suitable for 15 mm inner dia pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
Supply and Fixing 20 mm dia bib tap long body, fancy type, chromium plated, screwed down and fixed suitable for 20 mm inner dia pipe complete all as specified and as directed.
Supply and Fixing CP mixer for mixing hot and cold water fancy type, chromium plated, screwed down for pipe, with two outlets going (one for bib tap and other for shower) complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
Supply and Fixing angular cock 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure pipes complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
Supply and Fixing urinal water dropper, fancy type screwed down for size of 16mm outer dia pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
Supply and Fixing long body bib taps 15mm dia. cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for eight floor bathroom/toilet.
Supply and Fixing angular stop cock 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure pipes complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for eight floor bathroom/toilet.
Supply and Fixing two way bib taps 15mm dia. cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for eight floor bathroom/toilet.
Supply and Fixing 15 mm health faucet, chromium plated, fancy type with steel flexible complete suitable for 15 mm inner dia CPVC pipe complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for eight floor bathroom/toilet.
Supply and fixing overhead rain shower 200 x 200 mm with 200 mm Long arm complete all as specified and as directed
INTERNAL ELECTRIFICATION
Material and Labour for Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly One light point controlled by one switch or One bell point controlled by bell push or One fan (ceiling fan/exhaust fan) point controlled by one switch or One 3 Pin socket outlet 6 Amps socket on independent board complete all as specified and directed.
Material and Labour for Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly one 3 Pin socket outlet 5 Amps socket on the same board with other switches complete all as specified and directed.
Material and Labour for Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly one light point controlled by two Nos. two way switches complete all as specified and directed.
Material and labour for Point wiring with 4 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 4 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly one 3 pin socket outlet 15 Amps on independent board with 4 Sq.mm. FRLS PVC wire and one run of 4 Sq.mm. copper cable for earth continuity.
Material and Labour for sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 4 Sq.mm. cable and one run of 4 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed.
Material and Labour for sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 6 Sq.mm. cable and one run of 6 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed.
Material and Labour sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 25mm dia. with accessories complete with four runs of 10 Sq.mm. cable and one run of 10 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed. Note for Submain wiring: Two/Four (As specified) runs of cable, one run of earth wire and one run of PVC conduit will be measured as one unit.
Supply and Fixing LED adore lamp 10 Watts, 240 Volts AC, B22 type, CDS 5 star complete all as specified and as directed.
Supply and Fixing energy efficient LED Tube light fitting with tube 5W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets etc. including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified and as directed
Supply and Fixing energy efficient LED Tube light fitting with tube 10W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified and as directed
Supply and fixing energy efficient LED tube light fitting with tube 18/20 watts or nearest size, 240 volts 50 Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environment friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sqmm 3 core flexible copper conductor cable complete all as specified and as directed.
Supply and fixing energy efficient LED ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, 28 watts, 240 volts, 50 Hz environmental friendly suitable for grid ceiling in conference room complete with mounting bracket etc. including connecting up with 1.0 sqmm 3 core flexible copper conductor cable complete all as specified and as directed.
Supply and fixing energy efficient LED security light fitting with tube 30 watts new generation energy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre-wired with 1.0 Sqmm copper conductor cable upto connector including 1.5 metre long GI tubing light grade of 32 mm dia bend to shape for fixing on wall/ pole with suitable MS bracket nuts, bolts etc., complete all as specified and as directed.
Supply and Fixing energy efficient LED surface 2 x 2 grid panel luminaire 34 watts 240 volts, 50 Hz environmental friendly suitable for porch light complete with mounting bracket etc. including connecting up with 1.0 sqmm 3 core flexible copper conductor cable complete all as specified and as directed.
Supply and Fixing ceiling fans BLDC type, AC single Phase, 240 Volts of size 1200mm sweep with complete set with fixtures, 5 Star rating, metallic body complete all as specified and as directed.
Supply and Fixing exhaust fan 250mm sweep plastic body, complete with louvers suitable for operation on 230 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed.
Supply and Fixing exhaust fan 300mm sweep metallic body (Heavy duty), complete with louvers suitable for operation on 230 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed.
Supply and Fixing wall mounted fan, AC single phase 230 Volts of size 450 mm sweep, 5 star rating complete and inclusive of making necessary electric connection from ceiling rose to fan through twin core flexible wire complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to GI earth lead wire 4.0 mm dia [earth lead] and GI pipe 15 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed. Note: GI earth wire upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relevant item.
LIGHTENING PROTECTION
Material and Labour for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to galvanised iron strip of 32 x 6 mm (upto 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 5 of SSR part 1 including charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI cover 10mm thick hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel , 40mm dia light grade pipe for protection of earth electrode and 20mm dia pipe for watering including testing on completion complete all as specified and as directed.
COOLING APPLIANCES
Supply and installed commissioning of water cooler fully stainless steel electric driven (single phase) having approx. storage capacity of 120 litres and nominal cooling capacity of 60 litre per hour complete all as specified and as directed.
Supply installed commissioning of metal top deep freezer single phase 240 Volts 50 Hz hard top of capacity 250-320 litres capacity having double door complete all as specified and as directed.
Supply and fix refrigerators, electric driven (single phase), capacity more than 310 Litres upto to 360 Litres .BEE 5 star rated complete all as specified and as directed.
Supply and installed Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 140V to 280 V with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 2 KVA. complete all as specified and as directed.
EXTERNAL WATER SUPPLY
Material and Labour for ductile iron pipe 100mm dia. with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces (measure separately), including testing and commissioning complete all as specified and as directed.
Material and Labour for brick masonry valve chamber of size 750 x 750 x 750mm including necessary excavation, PCC foundation, brick work, plastering and MS sheet cover of 6mm thick including locking arrangement with two coats of red oxide primer and one coat of synthetic enamel paint of approved colour complete all as specified and as directed.
Material and Labour for earthing complete with GI plate electrode 600 x 600 x 6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32×6mm size by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 40mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on completion all as specified and as directed. Note: Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed.
Supply and fix sheet metal enclosure indoor type feeder panel with provision of fixing incoming and out going cables with bus bar and cable connection to tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 V, 200 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: Incoming:- (a) MCCB 32 Amps,25 KA, 4P - 01 No Outgoing:- (a) MCB 32 Amp,16 KA TPN - 03 Nos(for two 10 HP pumps + 01 Spare) (b) MCB 16 Amp,16 KA SPN - 01No(for bldg. ) (c) Star Delta Starter for 10 HP pumps - 02 Nos. (d) LED Indicating Lamps for each phase with colour Red Yellow Blue for R, Y and B Phases-03 Nos. (e) Multifunctional digital Meter.
S&F foot valve 100mm dia. with brass strainer, suitable flanges, nuts, bolts, gaskets etc. complete all as specified and as directed.
Supply, install, testing and commissioning of monoblock pump set with minimum ratings as 10 HP, 70 Mtr head, discharge 210 LPM with delivery size of 50mm bore, 415 Volts, 50 Hz, AC 3 Phase supply, electric driven, inclusive of air valve at delivery, pressure gauge along with cabling by XLPE copper cables from starter to pump set with cable tray and PCC foundation complete all as specified and as directed.
EXTERNAL ELECTRIFICATION
S&F Integral LED street light luminaire 30/35 Watts IP 65, comprising of epoxy powder coated, pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing complete all as specified and directed.
Supply, install, test and commissioning of solar LED luminaire of 24 Watt LED with autonomy of minimum 3 days including complete solar panels, charging units, Solar Low maintenance Flooded Battery, wiring, GI Battery Box, GI pole not less than 5 mtr height, fixing clamps, etc. complete all as specified and as directed.
S&F Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, combi-climate cable glands of IP 66/IP 67 for cable entry and grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, ‘C’ Curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc. complete all as specified and as directed.
S&F time switch 415 Volts, single phase of max 20 Amps rated, with contactor fitting inside steel enclosure complete all as specified and as directed.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 Volts grade,3.5 core 240 Sq.mm. sizes complete all as specified and as directed.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 Volts grade, 3.5 core 120 Sq.mm. complete all as specified and as directed.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 Volts grade, 3.5 Core 50 Sq.mm. complete all as specified and as directed.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 Volts grade, 3.5 Core 25 Sq.mm. complete all as specified and as directed 3 core 25 Sq.mm.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade, 2 Core 10 Sq.mm. complete all as specified and as directed.
Supply and fix FPB indoor, 4 pole MCCB 250 A ,rapturing capacity 35 kA made up of CRCA sheet of 2 mm thick front and back door operated with copper bus bar a capacity 400A, weather and water proof with necessary locking arrangements along with lugs, cable glands of suitable size for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting cables and the nuts/ bolts etc. used are to be made of brass material complete with powder coating, necessary internal electric connection as required with LED indicating lamps for each phase complete all as specified and as directed.
Supply, installation, testing and commissioning of LT Panel board made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switcher gear, suitable timer switch to control street light and security lights and the nuts/ bolts etc. used are to be made of rust proof material including as per IS: 8623 Aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 400 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Bldg. Panel)
INCOMING: (a) LT switch gear 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 250 Amp rated complete with overload protection, no-volt thermal based release. Make: L&T / Schneider/ Siemens - 01 No OUTGOING: (a) LT switch gear 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 200 Amp rated complete with overload protection, no-volt thermal based release. - 02 Nos.( 01 for build VTPN DB 12 way and spare.) (b) LT switch gear 440 volts 3 phase, 4 wire 50 cycles, 16 kA, MCCB of 63 Amp rated complete with overload protection, no-volt thermal based release. Make: L&T / Schneider/ Siemens - 02 ( 01 for DG AMF & 1 spare) (c) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc. with all connected CTs (d) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases Make: L&T/Schneider
Supply, installation, testing and commissioning of LT Panel board made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switcher gear, suitable timer switch to control street light and security lights and the nuts/ bolts etc. used are to be made of rust proof material including as per IS: 8623 Aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V, 200 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(DG Panel).
INCOMING: (a) LT switch gear 440 volts 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type MCCB of 63 Amp rated complete with overload protection, no-volt thermal based release. Make: L&T / Schneider/ Siemens - 01 No OUTGOING: (a) LT switch gear 440 volts 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type MCCB of 40 Amp rated complete with overload protection, no-volt thermal based release. Make: L&T / Schneider/ Siemens - 02 Nos (01 for Lifts Machine room,01 for spare ) (b) MCCB ,32 Amps, 4P, 440 volts 3 phase, 4 wire, 50 cycles, 16 kA - 02 Nos (01 No for fresh water pump panel, 01 for booster pump) (c) MCB , SPN, 20 Amps - 02 Nos (01 No for Street lights, 01 for Building Security/ Common area lights ) (d) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc. with all connected CTs (e)LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases Make: L&T/Schneider
Supply and fix sheet metal enclosure, provision of fixing incoming and out going cables with bus bar for cable connection tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 V ,200 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following all as specified and as directed. (For lift machine room) Incoming:- (a) MCCB 40 Amps,25 KA , 4P - 01 No Outgoing:- (a) MCB, TPN, 32 Amp - 03 Nos(for two lift panel + 01 Spare) (b) MCB , SPN, 20 Amp-01 No (c) LED Indicating Lamps for each phase with colour code Red Yellow Blue
Material and Labour for earthing complete with GI plate electrode 600 x 600 x 6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32 × 6mm size by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 40mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on completion all as specified and as directed. Note: Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed.
Material and Labour for galvanised iron strip 32 x 6mm size buried in ground/fixed to wall/ floor etc. complete all as specified and as directed.
Boring of holes under road, pavement, hard standing etc. by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe 150mm dia. suitable for 0.4 mpa working pressure complete all as specified and as directed.
Dismantling the existing Solar Street light any size including (Excavation PCC) and fixing the same with in a distance 80 mtr in new location complete all as specified and as directed.
Removing of Existing XLPE HT Cable of size 3.0 core 185 sqmm priced carefully from earth trench and relaying the same in new location at a distance not more than 50 m complete all as specified and directed. Note: Earth work, sand, brick will be measured and paid separately.
SOLAR POWER INVERTER
Supply, install, testing and commissioning of solar panel powered inverter (sine wave) with battery back up for 08 hours capacity 03 KW (Single phase 230 Volts, 50 Hz, AC supply) complete (off grid type) with and inclusive of all electrical and mechanical accessories & stand for inverter and batteries complete all as specified and as directed. Note: [i] Solar panel of Specification 320 Wp (Minimum) polycrystalline type to be provided. [ii] Inverter and battery back up shall be placed near the staircase 3. [iii] Tubular battery of 12 Volts, 150 AH of sufficient quantity to be provided and rate quoted shall be deemed included in the cost of batteries. [iv] Manual changeover switch 20 Amps single phase, 240 Volts to be provided near inverter for switching on to normal electric supply, in case solar system fails. Cost of the same deemed to be included in the rate quoted. [v] Solar inverter supply will feed to light fittings of parking area, staircase lights, building security lights in ground floor and passage lights, staircase lights of each floor of building. [vi] Before commencement of work contractor shall submit complete wiring diagram for approval.
FIRE FIGHTING SYSTEM
Supply and install of Fire extinguisher CO2 [light weight squeeze grip type of 3Kg capacity] conforming to IS 15683 complete all as specified
Supply and install of Fire extinguisher dry chemical powder (ABC) type of capacity 4kg conforming to IS 15683 complete all as specified
S&F DOL starter for booster pump sets with fixing arrangement for capacity of 7.5 HP pump complete all as specified and as directed.
M & L earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to GI earth lead wire 4.0 mm dia [earth lead] and GI pipe 50 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 x 40 x 6 mm angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed. Note: GI earth wire upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relevant item.
FIRE ALARM
Supply, fixing and testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables with stranded copper conductor of size 2 core 1.5 Sq.mm., 1100 Volts grade complete all as specified and as directed.
AVIATION LIGHT
Supply and Fixing for aviation obstruction light LED type filament-less bulb with 10 Watt bulb including standard fixing arrangements complete all as specified and as directed.
Supply and Fixing PVC insulated PVC sheathed armoured cable LT 1100 Volts grade with copper conductor of size 3 core 2.5 Sq.mm. multi stranded conductor laid in ground fixed to wall roof etc. with suitable clamps, spacers, bolts, nuts etc. complete all as specified and as directed.
Supply and Fixing time switches 250 Volts single Phase of 20 Amp rating with contactor fitted inside the steel enclosure complete all as specified and as directed.
DG SET
(A) Alternator: Standard design alternator rated at 30 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722. (i) Insulation class-'H‘ (ii) Temperature rise Class-'H‘ (iii) Excitation: Self Excited (iv) Regulation Performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% (v) Frequency regulation +/- 1%
(B) Diesel Engine: Adequate capacity of Diesel engine as approved by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:
(i) Fly wheel with housing (ii) Cooling System: Moulded radiator with fan & belts (iii) Cooling Water Pump: Centrifugal type belt driven (iv) Exhaust System: Exhaust System complete with exhaust piping of 150mm dia. with MS pipe light grade up to & outside and 1 meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer: Residual type Bellows (v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed/frequency regulation, Fuel filters, Fuel hoses. (vi) Lub oil System: Lubricating oil filter, Lubricating oil pump (vii) Air Intake System: Air intake Manifold, Air cleaner dry type (viii) Governor: Electronic Governor (ix) Starting System: Electric Self starter with maintenance free battery including battery charging alternator
(x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key/switch handling and operation. Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel
(xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for engine parameters, hour run meter, RPM meter, engine oil pressure indicator, water/coolant temperature indicator, battery volt display. (xii) Safety Controls: Engine low lube oil pressure high water temperature and over speeding of engine (xiii) Coupling Arrangement: Flexible coupling, fly wheel to suit flexible coupling (xiv) Accessories: AVM Pads built in enclosure and for entire unit on platform. (xv) Base Frame: Should be provided as OEM norms (xvi) Fuel Tank: Fuel Tank of capacity to suit daily 12 hours run service fuel tank made out of 2mm thick (14G) HR sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base in side the acoustic enclosure. (xvii) MS pipe line to and from the fuel tank to the DG Set
(C) AMF Panel : Factory made inbuilt type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 Phase 4 wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 30 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 Pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, KW, KWH, pf, temperature, battery voltage etc.
(D) Acoustic Enclosure: Manufactured by OEM suitable for 30 KVA DG Set (i) NAL approved as per CPCB (ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution Control Board. (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Construction details/specification are as follows: (a) Outer body: CRCA sheet of 1.6mm thick (b) Doors: CRCA sheet of 1.6mm thick (c) Sound Insulation: As per OEM Norms (v) The acoustic should be composite in construction and fully assembled integral unit (vi) The batteries should be placed inside the enclosure the DG Set (vii) the fuel tank is to located inside DG set (viii) The DG Set should be provided with external emergency stop push button (ix) The enclosure should be suitably illuminated by LED lamp fittings (x) The noise level should be 75 dba at 1m under free field conditions. (xi) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen Set Green. The base frame should be painted with epoxy based black shade.
(E) The coated rate includes excavation, removing of soft soil and PCC, cement concrete foundation, filling and mass concrete type B2 (1:2:4) using 40mm graded aggregate of size not less than as per OEM drawing for placing of DG Set complete all as specified and as directed. Note: The above all specifications may vary slightly as per OEM design and recommendation. In case of any slight variation as per OEM recommendation, the decision of GE will be final and binding.
Material and Labour earthing complete with GI plate electrode 600 x 600 x 6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32 x 6mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on completion all as specified and as directed. Note: Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed.
Shifting of existing DG set from CHAKRA building with in a distance 50 mtr including and dismantling of PCC foundation ,cable connection and disconnecting of existing cables, AMF panel and dismantling of PCC foundation complete all as specified and as directed.
GEYSER
Supply and fixing water geyser 25 litres storage/heating capacity , 5 star rating, with automatic on/off switch, absolute temp range knob, heat indicator and other safety devices single phase, 50 Hz, 230 Volts ( with and including inlet and outlet connections pipes and accessories for hot water and cold water) complete all as specified and as directed.
(f) Aluminium Chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with granite flooring complete. (g) Non Stop Button/ Independent Operation Braille Type. (h) Over load warning indicator both audio and visual type with tripping system having relays etc (overload protection/tripping system) (j) Front landing door of stainless steel mirror finish operations with a minimum time of 10seconds and up to a maximum time of 30 seconds. (k) Car size shall be conformity with IS-23534 1976 and body to be stainless steel of 16 gauge mirror finish with stainless hand rail 38mm hairline finish. (l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. (m) Toughened glass not less than 8mm thick suitable size as specified. (n) Opening with mirror of 5mm thick 200 x 800 mm size in all the doors (Car/ landing Doors) (o) Specifications plate with complete details (p) Continuous earthing for machine and equipments - 02 Nos. (q) Steel wire rope of adequate size as per relevant IS and as per manufacturer specifications. (r) Others standard fixtures and fitting like guide rails, sheaves counter weights with guards, buffers, gear unit breaks, control panel, locks, governor, car operational panel, power, control and trailing cables complete. (s) Full length display indicator panel. (t) Main drives and control shall be of latest, high effective and low power consumption.
(u) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase failure and low voltage. (v) Stainless steel front opened landing door with small opening for vision of size 200 mm x 800 mm toughened glass not less than 8mm thick. Make of toughened glass not less than 8mm thick. Make of toughened glass: SAFGEX/SAINT GOBAIN GLASS/ MODIGUARD FLOAT GLASS/KESAR/ AASHI INDIAN/ ATUL TUF/ HINDUSTAN PILKINGTON GLASS WORKS/ TRIVENIN FLOAT GLASS. (w) Intercom system be provided and connected with nearest security post / lift operator room.
(f) Aluminium Chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with granite flooring complete. (g) Non Stop Button/ Independent Operation Braille Type. (h) Over load warning indicator both audio and visual type with tripping system having relays etc (over load protection/tripping system). (j) Front landing door of stainless steel mirror finish operations with a minimum time of 19 seconds and upto a maximum time of 30 seconds. (k) car size shall be conformity with IS-3534-1976 and body to be stainless steel hand rail 38mm hairline finish. (l) Set of Three in number limit switches at the bottom and top most position of lift hoist ways as specified as specified in IS. (m) Toughened glass not less than 8mm thick suitable size as specified. (n) Opening with mirror of 5mm thick 200 x 800 mm size in all the Doors (Car/ landing Doors). (o) Specification plate with complete details. (p) Continuous earthing for machine and Equipment-02 Nos. (q) Steel wire rope of adequate size as per relevant IS and as per manufacturer specifications. (r) Other standard fixtures and fitting like guide rails sheaves, counter weights with guards, buffers, gear unit breakers, control panel, locks, governor, car operational panel, power, control and trailing cables complete.
(s) Full length display indicator panel. (t) main drives and control shall be of latest, high effective and low power consumption. (u) suitable phase failure and low voltage. (v) Stainless steel front opened landing door with small opening for vision of size 200 mm x 800 mm with toughened glass not less than 8mm thick. Make of toughened glass: Safgex/ Saint Gobain Glass/ Modiguard Float glass/Kesar/ asshi Indian/Atul Tuf/ Hindustan pilkington glass works/trivenin float glass. (w) Intercom system be provided and connected with nearest security post/Lift operator room.
M & L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32x6mm thick GI strip [earth lead] and GI pipe 40 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed. Note: GI earth strip upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relevant item.
ELECTRIC CHIMNEY
Design installation, testing, commissioning of electric operated chimney for cookhouse of approx size of platform 2M x 2.2M with chimney hood made of galvanised steel sheet with oil filter of minimum gauge 22 including GI ducting of 22 gauge for exhaust upto 15 mtr height of suitable size fixed on the wall with clamps angle iron frame, threading rod, nut bolts along with controlling dampers 04 Nos with suitable blowers motor of capacity 3HP with starter, controlling/ Display panel with auto clean system all as specified and as directed. NOTE: (a) The contractor shall submit the drawing of chimney for approval of engineer in charge before placing the order
Supply and fixing cable PVC insulated sheathed LT 1100 Volts grade with copper conductor of size 4 core 10 sqmm multi stranded conductor laid in ground/ fixed to wall/roof etc. with suitable clamps, spacers, bolts and nuts complete all as specified.
Material and Labour for Rigid non metallic PVC conduit 25mm dia concealed conduit in wall or clamped on wall excluding boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., providing GI wire for drawing cables complete all as specified and as directed.
Material and Labour for Rigid non metallic PVC conduit 40mm dia concealed conduit in wall or clamped on wall excluding boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as coupler
Supply and fixing modular type TV socket with and including prefabricated terminal box and switch plate for fixing TV socket complete all as specified and as directed.
Supply and fixing modular type Telephone socket with and including prefabricated terminal box and switch plate for fixing telephone socket complete all as specified and as directed.
Supply install and commissioning integrated public address and talk back facility for silt+8 floor building consisting of following: (A) LOUD SPEAKER SYSTEM of highly adaptable surface mount design, a 2way bass -reflex type 4" (10cm) cone Driver for low frequency and 1" (2.5 cm) balance dome tweeter for high frequency with internal transformer that allow both high impedance and low impedance drive of rating 15W/10. The nominal coverage angle shall be 110 Degree and horizontal and 110 Degree vertical. The measured sensivity shall be 88 db spl and maximum spl shall be 106 db spl. the bracket shall allow the loudspeaker to be mounted on both walls and ceilings. The loudspeaker shall comply with dust and water resistance rating of IPX3. The grille shall be constructed of 0.6mm thick powder coated perforated steel with an aperture ratio of 51% inclusive of all accessories and should be installed minimum 03 nos on Each floor
The speaker output shall be muted if the heat sink of the amplifier section exceeds 90 Degree centigrade or the impedance falls below rated, which resorted automatically. The analogue circuits shall be shut down if the power supply section exceeds 100 Degree centigrade. The Amplifier shall be cooled by two temperature controlled 3 step speed fans for minimum acoustic noise with AIR flow from front to back. The Amplifier shall conform to the latest EU ROHS hazardous substances and wee directives. (C) MIXING CONSOLE shall be versatile 6 channel mixer and have 6 line out put(2 micro, 2 stereo and 2 microphone inputs, two stereo output and one head phone output shall be provided. One stereo Bus shall be provided and have discrete class A "D-pre" types of high sound quality it shall be robust and built into an impact resistant powder coated metal chassis. Approximate dimension shall be 149 (w) x 202 (d) x 62 (h) mm NOTE: The rate quoted shall inclusive of all connected materials like suitable size copper wire for the entire system of all floors, microphone headphone, mike etc. complete required for the system as per site requirement.
SOLAR WATER HEATER AND SOLAR PANEL
Supply and fixing, Digital type water meter (Electromagnetic type) flanged type, MS body, for smart metering, of high accuracy, robust design, IP-67 enclosure, max flow 1500 Lpm for residential water supply scheme for fixing to 100mm dia MS/DI pipe line, with and inclusive of necessary nuts, bolts and washers for fixing, necessary excavation/ returning filling in, connecting FRLS PVC insulated 3 core, PVC sheathed unramoured copper wire drawn through GI pipe light grade 20mm as required at site and making connection complete all as specified and as directed.
Supply and fixing, Digital type water meter (Electromagnetic type) flanged type, MS body, for smart metering, of high accuracy, robust design, IP-67 enclosure, max flow 1500 Lpm for residential water supply scheme for fixing to 80mm dia MS/DI pipe line, with and inclusive of necessary nuts, bolts and washers for fixing, necessary excavation/ returning filling in, connecting FRLS PVC insulated 3 core, PVC sheathed unramoured copper wire drawn through GI pipe light grade 20mm as required at site and making connection complete all as specified and as directed.
Supply, install, testing and commissioning of solar water heating system, flat plate collector type based on indirect transfer of heat of 300 litre per day capacity, with connection through geyser in the toilet, kitchen etc all as specified and as directed.
SCHEDULE 'A' PART-XV OUTSOURCING OF LIFTS UNDER DEFECTS LIABILITY PERIOD FOR FIRST YEAR
Outsourcing of services for operation of electrically operated lift (8 Passengers-01)(13 Passengers-01) to serve (S+8 floors) by providing services of one lift operator [Semi Skilled] [metric/ssc qualified with 2 to 3 years of relevant experience]. Per each lift in each shift on all the days including Sunday & holidays in two shifts including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year during Defect liability period complete all as specified and as directed.
SCHEDULE 'A' PART-XVI: OUTSOURCING OF LIFTS UNDER DEFECTS LIABILITY PERIOD FOR SECOND YEAR
Outsourcing of services for operation of electrically operated lift (8 Passengers-01)(13 Passengers-01) to serve (S+8 floors) by providing services of one lift operator [Semi Skilled] [metric/ssc qualified with 2 to 3 years of relevant experience]. Per each lift in each shift on all the days including Sunday & holidays in two shifts including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year during Defect liability period complete all as specified and as directed.
Notes for item Nos.147, 149, 154, 158, 162 : (i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge. (ii) The timings for two shifts of 8 hours each daily i.e. First shift be from 0630 hours to 1430 Hours and Second Shift shall be from 1430 Hours to 2230 Hours. (iii) In case of non function of passenger lift, the Goods Lift installed in the same building shall be operated as directed. (iv) The work shall be supervised by adequately qualified supervisor with relevant experience of minimum 5 years items under BoQ shall be deemed to be including the same. (v) The unit rate is deemed to include for maintaining log books, record of repair /replacement of perished/unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed by the Engineer-in-Charge. (vi) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts. (vii) Conveyance and communication system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors. (viii) The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc.
(ix) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Bidders shall also insure the workmen employed on the job. (x) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same. (xi) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. "Name of the firm and designation" on front and on the back of the T-shirt along with protective clothing/ gear. The bidders shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. (xii) INSURANCE: The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations.
(xiii) The rate quoted by the bidders shall be deemed to be including basic rate [Minimum wages by Government of India/ State Government/ local body, whichever is higher], employers contribution towards Employees Provident Fund [EPF] liability , contribution towards Employees state insurance corporation [EISC], contribution towards Bonus, Overhead and profit and Labour welfare Cess [LWC] as applicable depending upon the manpower requirement. This will create onus on the bidders to ascertain in the relevant rates and quote accordingly. The rates quoted shall be inclusive of all Taxes, Cess, levies as applicable including GST. (xiv) The prevailing Rate/wage/Contribution shall be as applicable on the bid submission end date.
SCHEDULE 'A' PART-XVII Outsourcing and Comprehensive Maintenance of Electrically Operated Lifts for the First Year after Defect Liability Period
Outsourcing of services for operation of electrically operated lift (8 Passengers-01)(13 Passengers-01) to serve (S+8 floors) by providing services of one lift operator [Semi Skilled] [metric/ssc qualified with 2 to 3 years of relevant experience]. Per each lift in each shift on all the days including Sunday & holidays in two shifts including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year after completion of Defect liability period complete all as specified and as directed.
Comprehensive maintenance of electrically operated Passenger lifts (8 passenger) to serve (S+8 floors) complete including ARD and all connected components of lift during 1st year after expiry of Defect liability period all as specified and directed.
Comprehensive maintenance of electrically operated Passenger lifts (13 passenger) to serve (S+8 floors) complete including ARD and all connected components of lift during 1st year after expiry of Defect liability period all as specified and directed.
SCHEDULE 'A' PART-XVIII: Outsourcing and Comprehensive Maintenance of Electrically Operated Lifts for the Second Year after Defect Liability Period
Outsourcing of services for operation of electrically operated lift (8 Passengers-01)(13 Passengers-01) to serve (S+8 floors) by providing services of one lift operator [Semi Skilled] [metric/ssc qualified with 2 to 3 years of relevant experience]. Per each lift in each shift on all the days including Sunday & holidays in two shifts including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year after completion of Defect liability period complete all as specified and as directed.
Comprehensive maintenance of electrically operated Passenger lifts (8 passenger) to serve (S+8 floors) complete including ARD and all connected components of lift during 2nd year after completion of work and after completion of first year Comprehensive Maintenance.
Comprehensive maintenance of electrically operated Passenger lifts (13 passenger) to serve (S+8 floors) complete including ARD and all connected components of lift during 2nd year after completion of work and after completion of first year Comprehensive Maintenance.
SCHEDULE 'A' PART-XIX: Outsourcing and Comprehensive Maintenance of Electrically Operated Lifts for the Third Year after Defect Liability Period
Outsourcing of services for operation of electrically operated lift (8 Passengers-01)(13 Passengers-01) to serve (S+8 floors) by providing services of one lift operator [Semi Skilled] [metric/ssc qualified with 2 to 3 years of relevant experience]. Per each lift in each shift on all the days including Sunday & holidays in two shifts including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 3rd year after completion of Defect liability period complete all as specified and as directed.
Comprehensive maintenance of electrically operated Passenger lifts (8 passenger) to serve (S+8 floors) complete including ARD and all connected components of lift during 3rd year after completion of work and after completion of second year Comprehensive Maintenance.
Comprehensive maintenance of electrically operated Passenger lifts (13 passenger) to serve (S+8 floors) complete including ARD and all connected components of lift during 3rd year after completion of work and after completion of Second year Comprehensive Maintenance.
Notes for item Nos. 139,140,143,144,147,148 : (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation. (iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engineer-in-Charge. (vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM.
Komal Buildcon Pvt. Ltd.
B DURGA REDDY INFRASTRUCTURES PRIVATE LIMITED
SOOD ASSOCIATES PVT LTD
Indus Projects Private Limited
CHHABINDRA KUMAR PRADHAN
SHRI GURMUKHDAS CONTRACTORS PVT. LTD.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf