Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC | ₹4.1 Cr | L1 | Accepted-AOC being lowest |
| 2 | L2₹4.1 Cr+₹3.5 L (0.84%)Rejected-Finance 112 AMBALA ROAD NARAINGARH AMBALA 134203 | NARAINGARH | AMBALA | HARYANA | 134203 | ₹4.1 Cr+₹3.5 L (0.84%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹4.1 Cr+₹4.5 L (1.10%)Rejected-Finance BAKRON KA WADA NEAR NEELAM CINEMA JODHPUR ROAD BALOTRA BARMER RAJASTHAN 344022 | BALOTRA | BARMER | RAJASTHAN | 344022 | ₹4.1 Cr+₹4.5 L (1.10%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹4.4 Cr+₹25.3 L (6.17%)Rejected-Finance 300 GOPAL NIWAS 3 A ROAD SARDARPURA JODHPUR CITY RAJASTHAN 342003 | JODHPUR | RAJASTHAN | 342003 | ₹4.4 Cr+₹25.3 L (6.17%) | L4 | Rejected-Finance Not lowest |
| 5 | L5₹4.7 Cr+₹62.1 L (15.1%)Rejected-Finance | ₹4.7 Cr+₹62.1 L (15.1%) | L5 | Rejected-Finance Not lowest |
Tender Value
₹4.8 Cr
EMD Value
₹5.5 L
Closing Date
30 May 2022, 6:00 pmClosed
CE (AF) Gandhinagar
HQ CE (AF) Gandhinagar Lekawada Patia Chiloda PO CRPF Campus Gandhinagar-382042
MODERNISATION OF TECH FLT HANGAR AT AIR FORCE STATION JODHPUR
2022_MES_514118_1
80311/E8
Open Tender
Civil Works
Lump-sum
540 days
GE (AF) Jodhpur
As per NIT and Tender Documents
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) Jodhpur
₹5.5 L
Yes
2 Jul 2022
17 Mar 2022
31 May 2022
17 Mar 2022
30 May 2022
4 May 2022
19 Mar 2022 - 9 Apr 2022
Amount
NOTE: Schedule ‘A’ Part I to IX are under Ser No. 2.00 to 10.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for Excavation & Earthwork as listed in Sch `A’ Part II
Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part III
Lump sum price worked out for Road/Path/Culvert/ Hardstanding as listed in Sch `A’ Part IV
Lump sum price worked out for Area Drainage as listed in Sch `A’ Part V
Lump sum price worked out for External Electrification, Lightening protection and Standby Power Supply as listed in Sch `A’ Part VI
Lump sum price worked out for Cooling Appliances as listed in Sch `A’ Part VII
Lump sum price worked out for Special Item of Work (B/R) as listed in Sch `A’ Part VIII
Lump sum price worked out forAdditional B/R items as listed in Sch `A’ Part IX
SCHEDULE `A' PART - X Fittings & fixtures is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
M&L for preparation of new surface and applying two coat of EPU painting of any description over 10cm girth or width not otherwise described and applying in hanger sheet in camouflage pattern as approved by user/ GE complete all as specified and as directed by Engr-in-Charge. Note:- Quoted rate shall be deemed to be included for work in buildings/ structure of any height.
S & F polycarbonate sheets of 3.0mm thick having the following properties:- excellent weather properties, excellent light transmission ranges from 80% to 90% and both side UV coated weight ranges from 850.0 gms to 900gms. Fixing of sheets shall be accordance with manufacturer instruction and all as directed by Engr-in-charge.
M & L Providing 5mm thick high density EPU flooring includes priming, screed topping antistatic type including making good to surface before application of low viscous epoxy primer having resin & hardener in equal volumes, approved by CPRI (Central power Research Institute Bangalore). Work shall be carried out as per manufacturer instructions.
M&L Providing and fixing and commissioning of wind driven turbo ventilators having average capacity of 1500 to 2000 CFM, having neck diameter 700-750 mm and 42 nos fins. Top plate and bottom ring shall be made high grade stainless steel (SS-304) and fins to be made of high grade aluminium (H-14) of minimum thickness 0.71 mm. The base and hopper shall be constructed of UV stabilized FRP of minimum thickness 3 mm matching with roof sheet profile. The rate shall be include fixing of FRP base along with ventilator and special leak proof tape should be used in between all four sides , making it totally water tight etc. The rate also includes all lead and lift, transportation materials, labours, taxes, etc complete. The work should be carryout as directed by Engr-in-Charge and as per manufacturer instructions.
S & F UPVC (SWR) pipes 160mm bore single socketed in any length with rubber ring joints fixed to walls
S & F in repairs Vitreous China Urinal including stainless steel coupling, PVC waste pipe, half stall type, ivory of size 420 x 395 x 635 mm including stainless steel coupling PVC waste pipe complete all as specified.
S & F coloured counter type wash basin of size 570 x 450 mm dia including stainless steel coupling, PVC waste pipe complete all as specified.
S&F stainless steel Toilet paper Holder to wall with necessary fixing arrangement complete all as specified and as directed.
S&F single lever basin mixer without popup waste with 450mm long braided hoses complete all as specified and directed.
M & L Wet mix macadam 150 mm thick (75 mm in two layers compacted thickness) laid with coarse aggregate of grading 1 (90 to 40 mm size) specified in MORTH, spread rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete using mechanical paver.
M&L high density polytheene film (transparent colour) in single layer of 400 Micron thickness virgin quality as per ASTMD 2103/IS 2508 laid with side and overlapping not less than 300 mm complete all as specified and as directed.
Material and labour for forming 25mm thick expansion joint by full depth using diamond cutter, filled with DURA board HD-100 (Brand supreme or equivalent as approved), applying bond breaker tape on top of board for complete depth of joint i.e. the thick ness of concrete slab, provision of closed celled polyurethane sealant (Minimum depth of sealant above backup rod shall be 15 mm), complying with BS- 4254 and EN 41875 2003 priming the sides minimum MAF + 30% with ten years performance guarantee and applying masking tape on edges of joint to prevent accidental spillage of sealant on top surface and to give neat finish to the sealant and removing the masking tape after sealant is applied for thickness of concrete slab minimum 300 mm and maximum 400 mm complete all as specified and directed.
Material and labour forming construction joint, 30 mm deep and 10 mm wide (using diamond cutter) providing polyurethane sealant (Minimum depth of sealant 12 mm), complying with BS 5212, BS 4254 and EN 41875-2003 priming the sides minimum MAF + 30% with ten years performance guarantee and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surfaces and to give a neat finish to the sealant as shown on drawing and removing the masking tape after sealant is applied complete all as specified and directed.
Material and labour for forming contraction (dummy joint), 65mm deep and 10 mm wide (using diamond cutter) filled with polyurethane sealant (Minimum depth of sealant 12 mm) complying with BS : 5212 and fixing 10mm dia polyurethane rod and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surfaces and to give a neat finish to the sealant in position as required complete all as per manufacturer's instructions complete all as specified and directed.
M&L for boring of hole under road, pavement, hard standing by trench less technology using ultrasound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure
M&L for LT Feeder Pillar ( Kiosk)of size not less than 60 cm (L) x 22 cm (B) x 45 cm (H) made out 3.15 mm thick CRCAsheet out door type CPRI approved) with openable Front door including locking arrangement with suitable copper busbar 200 Amp 3 P & N system rating and fixed on angle iron frame 40 x 40 X 6mm and PCC plinth and MCCB of 63 Amp ,25 KA ,thermal based for tripping and controlling complete all as specified and directed
Material and labour for stone slab/patti, 40 to 50mm thick, rough dressed, Jodhpur stone slab cover in trenches for protection of cables, 25 cm to 35 cm wide and 80 cm long, laid dry abutting each other with gap between adjacent slab not exceeding 10mm complete all as specified and directed.
Supplying, installing, testing & commissioning of factory assembled Diesel Engine driven generating set with automatic mains failure panel fully wired alternator AC to give an output of 125 KVA /100 kw ,continuously rating at a PF of 0.8 lagging, 415 volts , AC 3 phase 4 wire 50 HZ ,1500 RPM, directly coupled with diesel engine water cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories with PCC foundation work as per manufacturer's instructions, vibration damper pads & other accessories etc.
Diesel Engine: Radiator cooled turbocharger to deliver not less than 156 BHP at 1500 RPM, 6 cylinder under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10 % for one hour in any 12 continuous hours operation and designed and tested for 50°C ambient temperature. Well-designed air handling system with Dry type, Replaceable paper element air cleaner with restriction indicator. Air to air after cooling. Optimised turbocharger for increased altitude capabilities. Best in class fuel economy with HPCR fuel system with A1 class electronic governing. Dual fuel filter system: Pre filter including water separator and Water In Fuel (WIF) sensor and main filter. Electrical lift pump for faster response. Standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature. Full flow spin on lube oil filter. Plate type lube oil cooler. First fill of lube oil and coolant. Electrical starter motor with soft start engagement feature. Battery charging alternator. 1 X 12 V DC battery.
Alternator:- Alternator: 125 KVA at 0.8 PF ,415 Volt, 3 Phase, 4 wire, 50 Hz , at 1500 RPM , Brushless type, Screen protected, revolving field, Self-excited alternator conforming to IS/IEC 60034-1, ,3 Phase reconnect able winding with 12 terminals brought out for connection, better motor starting capability, best in class efficiency, Compact design with sealed bearing for longer life and lesser maintenance & Impregnation on all wound components for better mechanical strength. Control Panel : Control panel is manufactured with 14/16 gauge CRCA sheet powder coated for weather-proof and long lasting finish. including the following:- Power Command 1.2 Controller. Copper bus bars with suitable capacity with incoming/ outgoing terminals. Indicating lamps for ‘Load ON’ and ‘Set Running’. Instrument fuses duly wired and ferruled. MCCB of suitable rating with overload and short circuit protections.
AMF panel AMF Panel outdoor type, 125KVA DG Set with aluminium busbar of capacity 250Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3.15 mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 200Amps consisting the following:- INCOMING from 125 KVA (i) MCCB 200 Amp FP 25 KA - 01 No (ii) Spreaders 200 Amps FP - 01 Set (iii) Extended Rotary handle 200 Amps FP - 01 No (iv) Earth fault module - 01 No (v) Power Contactor 200 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No (vi) C.T. 250/5A CL-1.0 10 VA - 03 Nos (vii) Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No (xi) In built on load change over switch 200 A for bypassing of AMF panel - 01 No
Outgoing (i) MCCB 200 Amp FP 25 KA - 01 No (ii) Power Contactor 200 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF relay (iv) SMPS 12V, DC, 10A - 01 No (v) Emergency stop P.B - 01 No (vi) Digital Amp meter 12, DC - 01 No (vii) Digital Volt meter 12V, DC - 01 No (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No (x) PROCOM UNIT (DGC6D) FOR control - 01 No
Acoustic Enclosure : M & L for acoustic enclosure (canopy) for the above 125 KVA DG Set to reduce noise level to 75 dB (A) measured at 1.0 metre distance for audible frequencies as approved from CPCB II for emission compliance as per Central Pollution Control Board norms of suitable size as per manufacturer's specification and comprising of following :- Acoustic Enclosure made CRCA sheets in mussel green shade and a structural / sheet metal base frame painted in black. High quality noise absorbent and fire -retardant grade acoustic Insulation material (P.U Foam) complying to IS 8183. Two point lifting for easy handling. Air inlet louvers. Tank pre-treatment process and UV resistant powder coating of all parts to withstand extreme environment. Fluid drains for lube oil & fuel. Fuel filling arrangement inside the enclosure.
Supply & fix Heavy duty wall mounted type air circulator Electric Fan 240 Volts metal body with metal blades having 450 mm sweep all as per specified and directed.
Supply, installation and testing and commissioning air cooling machine /air washer consisting air flow up to 12.5 feet of top / down discharge three phase machine of capacity 25000Cum/hr air blow including required PCC foundation for mounting air washer as per OEM design comprising of following:- (a) Cabinet:- Double skin cabinets. (b) Base:- The total assembly is mounted on a horizontal member of heavy galvanised steel channel with die cast aluminium corners for joining together with lifting hole on all corners. (c) Panels: - Panels are made out of extruded aluminium hollow profile with PUF fix to the rugged frame work made on aluminium/GI section with fasteners/nuts/surts. The cabinet is air tight using self-adhesive tape and gasket. (d) Inspection window: - Air washer have proper accessibility for regular maintenance through hinged service door.
(e) Cellulose Pad: The cellulose pads are designed for max saturation efficiency, being having large air surface act area in 7 mm flute size. (f) Filters:- The standard pre filters made of GI/AL construction having efficiency 90% down to 30 micron . (g) Water tank:- Water tank made of mild steel/stainless steel with anti-corrosive coating(FRP/Epoxy) (h) Fan TEFC motor for 415 Volts and drive set:- The fan of suitable capacity curved design ,statically and dynamically balanced with low noise and high efficiency. The fan motor of suitable capacity mounted on GI/MS channel slide rail with provision with easy belt tension. The complete assembly is mounted on rubber vibration pad .The fan is connection to main casing using fire and moisture resistance flexible canvas connection ensuring low operating noise and vibration .The drive pulley are tapper bushed dully balanced with proper size of V belts. (i) Accessories:- (1) Fan outlet dampers. (2) Drift eliminator PVC/GI. (3) Microprocessor based control panel with sensors safety switches and indicators including complete wiring.
S&F MCB DB TPN 4 way double door IP 43 with MCB TPN 63 amps C curve type 01 NO and MCB SP 20 amps C curve type 12 Nos duly concealed /surface in wall and making good disturbed surfaces of wall, floor etc.
Providing and making Misc civil work like masonary wall cut outs and jurry work to pass Pipes, Cables & Ducts at sitewith required PCC foundations for tanks, cooler, Electrical panel board, etc. The cut-outs shall be closed and finished to the original finish after completion of work.
Taking down DB any type / any size.
Taking down Sub main wiring incl. accessories.
Dismantling and taking down with proper pump down of split AC any capacity from site and refix after repair work complete all as per specified and directed by engg-in -charge.
Supply & fix LED luminaire 600mm x 600 mm, 35/36 watt, 220 Volt AC recessed type with high efficiency PMMA diffuser soft glave free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three case flexible copper conductor cases of suitable size complete.
Supply & fix LED tube light along with fixture, 22 W
Supply & fix mirror LED light decorative 1X 8W ,2 ft box type alongwith LED tube rod with all fitting and accessories fixed to wall.
Supply & fix MCB SP 250V 6Amps to 32 Amps 10 KA rating ISI marked and connecting complete all as specified.
Taking down carefully and refixing TPN/SPN DB any type / any size including all necessary connection all as per directed by EIC .
Dismantling and Taking down existing hanging LED flood light from hangar and re fixing in situ after completion of roof top sheet workall as per directed by EIC.
S&F Hot dipped galvanized cable tray perforated type of size 50 x 200 mm for laying of cables including all fitting accessories as per site requirement all as per specified.
Design, testing, installation of motorisation system in existing hanger door (03 leave single side 8m*5m size of single leave) including lowering to hanger door ,reinstallation ,replacement of wheels ,addition/alteration in structure of hanger door as per site requirement including supply and installation of 3 phase motors of suitable capacity, chain drive gear box mechanism all accessories required like control panel ,manual key release, cable, Rope wire ,cable carrier, hotter &Blinker complete set with Double side ball bearing, shaft & mounting plate 6 pcs and automatic aircraft hangar door top roller wheel assembly 6 pcs complete all as specified and directed . Note:- The designing of motor and wheel size ,drive system shall be submitted by contractor to Eng in charge for Approval of GE.
M&L red neon obstruction LED Aviation light 15W, 230V weather proof IP 56 as per 2147 all as per specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.71 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and all as directed by Engr-in-Charge
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet steel sheet 0.71 mm thick of an colour having tensile strength of 550 Mpa as in gutter/roof covering/cladding to wall fixed with/gates self tapping screws complete all as specified and as directed by Engr-in-Charge
S&F SS bird proof net of wire netting of stainless steel wire 0.91mm dia and size of mesh 12x12mm fixed with tinned tacks of stainless steel wire staples as approved by GE. GI framing work of grid size 2mtr x2mtr using GI perimeter channel 0.5 mm thick with two unequal flanges of 20mm and 30mm and web of 27 mm welded to surrounding wall and intermediate channels including all fittings and fixtures shall be provided over the bird net. 4 mm thick stainless steel wire mesh with aperture of 150mm x 150mm c/c will be provided complete all as specified and directed.
S&F Urinal spreader of CP fixing with 15mm dia pipe (min. weight 60gms) complete all as specified and as directed by Engr-in-Charge .
S&F Grating doom 125mm dia. with waste hole of CP (minimum weight 40 gms), complete all as specified and directed by Engr-in-Charge.
S&F Health Faucet ABS body with 1 meter SS braided connection pipe & wall hook, complete all as specified and directed by Engr-in-Charge.
Sch of credit Rs 338715.00
J S Construction Company
Brahma Infra
UTSAV INDIA LIMITED
JAGDISH PRASAD & CO
M/s Mohata Buildcon
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .