| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-Finance AT NEAR BOI PHUSBUNGLOW SINDRI ROAD BHAGA DHANBAD JHARKHAND 828301 | BHAGA | DHANBAD | JHARKHAND | 828301 | ₹1.9 Cr | L1 | Accepted-Finance Finance |
| 2 | L2₹1.9 Cr+₹1.2 L (0.64%)Accepted-Finance KUSUM VIHAR DHANBAD | DHANBAD | JHARKHAND | 818142 | ₹1.9 Cr+₹1.2 L (0.64%) | L2 | Accepted-Finance Finance |
| 3 | L3₹2.0 Cr+₹9.1 L (4.87%)Accepted-Finance | ₹2.0 Cr+₹9.1 L (4.87%) | L3 | Accepted-Finance Finace |
| 4 | L4₹2.0 Cr+₹11.2 L (5.97%)Accepted-Finance 55 H 2 HOSSION SHAH ROAD KIDDERPORE KOLKATA 700023 WEST BENGAL INDIA | KOLKATA | KOLKATA | WEST BENGAL | 700023 | ₹2.0 Cr+₹11.2 L (5.97%) | L4 | Accepted-Finance Finance |
Tender Value
₹2.4 Cr
EMD Value
₹4.7 L
Closing Date
5 May 2025, 4:00 pmClosed
Managing Director
Office of the Managing Director, Jharkhand Mineral Area Development Authority,Luby Circular Road, Dhanbad.
Supply, Install, Testing and Commissioning of 11KV 400A VCB, 415V 1600A ACB, FASD Starter and Supply, Laying with jointing of different size of cables and Its allied electrical works at 1MVA Sub-Station and 9 MGD WTP Jamadoba under JMADA, Dhanb
2025_UDD_100434_1
03/JMADA/2025-26 (Gr A)
Open Tender
Electrical Works
Item Rate
180 days
Jamadoba Dhanbad
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹4.7 L
Yes
6 Jun 2025
21 Apr 2025
6 May 2025
21 Apr 2025
5 May 2025
21 Apr 2025
Amount
Cost towards Supply, Installation, Testing and Commissioning of 400 Amps Indoor Vaccum Circuit Breaker (VCB), operated on 11KV, 3Phase, 50Hz, ISI Marked with suitable other fitting & accessories including all labour tools, tackles and technician costs etc all complete.
Cost towards Supply, Installation, Testing and Commissioning of 400 Amps Outdoor Vaccum Circuit Breaker (VCB), operated on 11KV, 3Phase, 50Hz, ISI Marked with suitable other fitting & accessories including all labour tools, tackles and technician costs etc all complete.
Cost for Supplying of 3C X 300 sq. mm Aluminium armoured 11 KV Grade, PVC insulated and PVC sheathed, ISI marked, Heavy duty.
Cost for Supplying of 3C X 240 sq. mm Aluminium armoured 3.3 KV Grade, PVC insulated and PVC sheathed, ISI marked, Heavy duty.
Cost for Laying of above PVC insulated and PVC sheathed / XLPE power cable of 11 KV & 3.3KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of above XLPE aluminium conductor cable of 11 KV & 3.3KV grade as required
Supplying and making Indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of above XLPE aluminium conductor cable of 11 KV & 3.3KV grade as required
Cost for Supplying of 3.5C X 150 sq. mm Aluminium armoured 1.1 KV Grade, PVC insulated and PVC sheathed, ISI marked, Heavy duty.
Cost for Laying of different size of above PVC insulated and PVC sheathed / XLPE power cable, direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supplying and making LT cable jointing with all accessories including lugs suitable for above cable including all labour tools, tackles and technician charges.
Cost for Supplying of 3C X 185 sq. mm Aluminium armoured 3.3 KV Grade, PVC insulated and PVC sheathed, ISI marked, Heavy duty.
(B) 9 MGD WTP Cost for Supplying of 3C X 240 sq. mm Aluminium armoured 3.3 KV Grade, PVC insulated and PVC sheathed, ISI marked, Heavy duty.
Cost for Supplying of 3C X 185 sq. mm , Aluminium XLPE armoured 3.3 KV Grade, PVC insulated and PVC sheathed, ISI marked, Heavy duty.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for above XLPE cable of 3.3 KV grade as required
Supplying and making Indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for above XLPE cable of 3.3 KV grade as required
Cost for Laying of different size of above PVC insulated and PVC sheathed / XLPE power cable, direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Cost towards Supply, Installation, Testing and Commissioning of 400 A Indoor Vaccum Circuit Breaker (VCB), operated on 11KV, 3Phase, 50Hz, ISI Marked with suitable other fitting & accessories including all labour tools, tackles and technician costs etc all complete.
Cost towards Supply,Installation,Testing and Commissioning of 3.3 KV,400 Amps. Star delta soft starter including all protective relays such as motor protection relay,CTMR relay,SPP relay with over current and E/L relay with suitable other fitting & accessories including all labour tools, tackles and technician costs etc all complete.
Cost towards Supply, Installation, Testing and Commissioning of Automatic 110 V Float & Boost Battery Charger for Battery Bank etc all complete , testing on full load at site including all labour tools, tackles and electrician cost all complete.
Cost for Supply, Fitting and Installation of 110V D.C. Battery back up 55 Nos. of cells“Exide”make VRLA Type ( Sealed Maintenance ) 2V, 100 AH x 55 Nos. and jointing and making connections to make the Battery bank as required etc all complete.
MAITREE ENTERPRISES (BID ID -657737)
M/S J.P. ELECTRICALS (BID ID -657740)
ELECTRO POWER (BID ID -657815)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .