Loading…
Loading…
Tender Value
₹31.2 L
EMD Value
₹50,000
Closing Date
14 Jul 2026, 5:00 pm6d left
SANTHOSH KUMAR
OFFFICE OF THE EXECUTIVE ENGINEER KSHB PATHANAMTHITTA DN THIRUVALLA
Supply installation testing and commissioning of New lift near judicial gate at Revenue tower, Thiruvalla
2026_KSHB_859268_1
KSHB/PTA/T4/2026-27
Open Tender
Electrical Works
60 days
Thiruvalla
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,950
Yes
₹50,000
Yes
6 Jul 2026
6 Jul 2026
16 Jul 2026
6 Jul 2026
14 Jul 2026
6 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1LIFT | |||||
| 1.001 | OD1718/2026-2027: Supply, erection, testing, and commissioning of V3F passenger cum freight lift 13 Person capacity (884 KG) suitable for installing 1900 X 2500 mm as per the Actual size of the lift well at the site and the following requirements.Number of Openings from cellar + Ground to four floors (C+G+1+2+3+4) Full Height Infrared Light curtain in the car door safety in full length. Door open and door close Buttons. Separate fan switch with timer cut off in the car. Indication of car and Landing call registration, Position indicator in the car, and all landings. Variable speed Door opening and closing time. Inverter-based Emergency alarm bell. Stainless Steel Cabin hairline finishing with half-portion glass Height toughened viewing glass suitable thickness of both car and Landing door with frame work etc., and also provide the facilities to fix advertisements on the two sides of the lift wall Signal Fixtures. Emergency LED Lights supported with an inverter. Call registering micro push button. intercom system, Door Pressure Limit Switch (Enhanced Door Safety). Serial communication-based LCE Controller. Special features Battery-operated rescue device for power failure Braille buttons for car and landing Lift Floor Announcement system Intercom. Speed 1.00 Meter/Second Type of Drive Variable Voltage Variable Frequency (VVVF) Imported. Location of Machine Room Above the Lift Well. Machine Motor Unit Three Phase, Induction Motor, 415V Location of Machine Room Above the Lift Well. Overload protection. Granite Flooring, SS handrail, etc., complete as per EI & KSEB rules. Necessary lift Approval and License shall be obtained from the EI as per the Contractor's scope; the Elevator shall be designed in line with the recommendation continued in the latest edition of applicable Indian Standards. The design / Construction /Installation codes shall confirm the latest edition of IS:14665(All parts) and also meet any additional requirements of IS: 4666, IS : 1860 and I S : 3534 and any other equivalent code | - | each | - | - |
| 1.002 | OD83067/2026-2027:Providing Comprehensive Annual Maintenance Contract (CAMC) for Passenger Lift for a period of 5 years after the Defect Liability Period (DLP), including monthly preventive maintenance, routine servicing, unlimited breakdown maintenance, testing, adjustment, and replacement of all consumables, spare parts, electrical, electronic, and mechanical components (including Drive, ARD, COP, LOP, control panel components, cabin lights, fans, alarm buzzer, door mechanisms, travelling cables, machine parts, ropes, guide shoes, and all other accessories) required for the safe and satisfactory operation of the lift. The rate shall include all labour, materials, tools, transportation, consumables, testing, and incidental charges complete. Statutory inspection fees, licence renewal fees, and insurance charges payable to Government/Statutory Authorities shall be borne by the Department. | - | each | - | - |
| 2ADDITIONAL ELECTRICAL WORK FOR LIFT WELL | |||||
| 2.001 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A | - | point | - | - |
| 2.002 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | - | metre | - | - |
| 2.003 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | - | each | - | - |
| 2.004 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | - | each | - | - |
| 2.005 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | - | each | - | - |
| 2.006 | 2.13.3:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps | - | each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.17 MB
PreliminaryAgreement.pdf
Tender Documents • 0.01 MB
BOQ_1452931.xls
BOQ • 0.31 MB
SBDLIFTRTT.pdf
Tender Documents • 0.30 MB
EPayment.pdf
Tender Documents • 0.23 MB
ML.pdf
Tender Documents • 0.31 MB
ipact.pdf
Tender Documents • 0.04 MB
affidavit.pdf
Tender Documents • 0.05 MB
Download all tender documents and submit your bid