Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹3.5 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹4.9 Cr+₹1.4 Cr (40.5%)Rejected-Finance 35 333A FIRST FLOOR 40 VILANGADAN ESTATE MAMANGALAM POTTAKUZHI ROAD VILLAGE TOWN PALARIVATTOM CITY ERNAKULAM | ₹4.9 Cr+₹1.4 Cr (40.5%) | L2 | Rejected-Finance 2nd Lowest |
| 3 | L3₹5.1 Cr+₹1.7 Cr (47.7%)Rejected-Finance | ₹5.1 Cr+₹1.7 Cr (47.7%) | L3 | Rejected-Finance 3rd Lowest |
| 4 | L4₹5.2 Cr+₹1.8 Cr (51.7%)Rejected-Finance DOOR NO 32 939C 1ST FLOOR CITY SCAPE BUILDING CHANGAMPUZHA NAGAR P O SOUTH KALAMASSERY ERNAKULAM KERALA 682033 | ERNAKULAM | KERALA | 682033 | ₹5.2 Cr+₹1.8 Cr (51.7%) | L4 | Rejected-Finance 4th Lowest |
Tender Value
₹4.4 Cr
Closing Date
4 Sept 2018, 6:00 pmClosed
GM- RS and E
6th FLOOR, REVENUE TOWER, PARK AVENUE ROAD, KOCHI
E and M Works of Property development Areas for MG Road, Aluva And JLNS stations
2018_KMRL_225768_1
KMRL/SYS/EandM/PD/TEN 08-2018
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KOCHI
As per tender document
17 documents required · 17 mandatory
₹5,310
Yes
online
Exempted
KOCHI METRO RAIL LIMITED
4 Jun 2020
3 Aug 2018
7 Sept 2018
3 Aug 2018
4 Sept 2018
20 Aug 2018
3 Aug 2018 - 16 Aug 2018
16 Aug 2018
Amount
ELECTRIFICATION SYSTEM
INTERNAL WIRING & LT ELECTRIFICATION POINT WIRING Supply & laying of conduit and wiring for the following light / Ceiling Fan/ Exhaust Fan / Bracket fan point with 3 x 2.5 sq. mm, 1100 Volt grade PVC insulated FR copper condutor wires in heavy gauge GI conduit surface run with GI saddles, or concealed or in GI raceway including chases and complete with GI junction boxes, pull boxes, inspection boxes,bends & other accessories etc. including insulated Protective Earth (PE) Conductor and earthing of switch boxes excluding the cost of switches/sockets and switch boxes as specified and as under:
First point controlled by one 6A switch / 10A MCB
Secondary or looping points wiring as specified in 1.1 above using 3x2.5 copper (P+N+PE) wires in 25 dia GI conduit for lights, fans, socket outlets including providing terminal block, ceiling rose & other accessories etc as required (exlcuding the cost of switches, sockets & switch boxes) as per specifications and drawings as required
CIRCUIT WIRING Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed GI conduit as required 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
POWER POINTS 6/16 Amp Universal socket with 16 amp modular switch
MCB DISTRIBUTION BOARDS AND ENCLOSURES Supply, installation, testing & commissioning of front operated front access cubical type indoor duty dead front wall / recess/ surface mounting, totally enclosed dust and vermin proof ( minimum protection IP 54 ) panels with foamed-in neoprene gasketted hinged doors, fabricated from 2 mm thick CRCA with powder coated finish suitable for 415 V, 3-phase, 4 wire, 50 Hz system including suitably rated insulated copper busbars, interconnections, neutral bar assembly, phase segregating barriers, LED indicating lamps for incoming and outgoing feeders,15% spare space for future expansion, knockouts and gland plates for entry of cables and conduits, all internal wiring using high temperature FR wires, independant terminals for each phase, earthing terminals and including the cost of providing Master key lock on the door and pad locking facility on door as well as at incomer, bonding to earth etc. complete as per specification, drawings as required and as under: MCBs shall conform to IEC898/IS 8828 (latest) and, with breaking capacity 10 kA at 415 V AC, current limiting type lower powerloss appx 40 - 70% of the stipulated value and suitable for magnetic releases operating between 3 to 5 times rated current for normal power distribution application and 5 to 10 times rated current for motor application duty, with minimum Electrical endurance of the order of 20000 operation cycles. Residual current circuit breaker (RCCB) conforming to IS 12640 shall be provided with 30mA sensitivity and electrically connected rated current capacity MCB for short circuit and over load protection as required All incomer MCBs of boards /panels shall be provided with NO/NC contacts as specified in specifications and drawings All the contactors shall be provided with potential free contacts for remote monitoring and control. 6 WAY TPN with Timer on 2-phases 1-40 amp TPN 10 kA MCB with thermal magnetic protective releases incoming with 1 single phase bank comprising of 1-40 amp30 mA DP ELCB incoming and 6 no. 6/16/20 amps SP 10 kA MCB with thermal magnetic protective releases out goings 2 single phase banks each comprising of 1-40 amp 30 mA DP ELCB incoming with 32 amp ON position latched contactor and 24 hours programe timer for operation of incoming and 6 no. 6/16/20 amps SP 10 kA MCB with thermal magnetic protective releases out goings
Supplying and fixing of following ways surface/recess mounting, vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A, tinned copper busbar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3phase outlets are required.) 4 way (4 + 12), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in suitable enclosure complete with connections, testing and commissioning etc. as required. 800 Amps
LIGHTING FIXTURES-SUPPLY & INSTALLATION Supply, installation, testing & commissioning of light fittings including all accessories e.g. ballast, HPF condensors, lamps, holders, surface/recess mounting arrangement etc. including necessary supports, accessories and hardware as per specifications & as required at site and as below: Luminaire minimum specifications and requirements Luminaires should operate at +/- 6% voltage fluctuation for continuous use to comply to IEC. PF > 0.95 for HF ballasts; for EM circuits PF > 0.85 with capacitor. All the components including the internal wiring of the luminaries to be used shall be manufactured of material, which are of FR type. All luminaires shall be manufactured to relevant sections of IEC60598 or other approved international standards and the type tests for all luminaries shall be provided. All internal wiring within the lighting fixtures shall be heat-resisting cables.
Supply, Installation, Testing & commissioning of surface/ceiling mounted 4 ft LED luminaire. The housing is made of extruded aluminium with a CRCA front frame. It has a system level lumen package of 3991 lumens with system wattage of 40 W. The luminaire is IP 20 protected. Specified as Philips 40 W Endura LED or equivalent.
Supply, Installation, Testing & commissioning of surface/ceiling mounted 4 ft LED luminaire. The housing is made of extruded aluminium with a CRCA front frame. It has a system level lumen package of 1947 lumens with system wattage of 20 W. The luminaire is IP 54 protected. Specified as Philips WT201 LED20S or equivalent.
Supply, Installation, Testing & commissioning of surface/ceiling mounted high bay light. The housing is made of extruded aluminium with a CRCA front frame. It has a system level lumen package of 5700 lumens with system wattage of 60 W. The luminaire is IP 20 protected. Specified as Philips BY150P P LED 76S CW PSU HE SY12 or equivalent.
POWER SIDE ELECTRIFICATION LV ARMOURED CABLING WORK Supply, Laying, Testing and Commissioning of 1.1kV grade, armoured FRLS, XLPE Aluminium(Al)/ Copper(Cu) conductor cables on trays/walls/columns/indoor/trenches including the cost of supports with suitable clamps, saddles, hooks, bolts etc and including the cost of proper dressing of cables, markers providing identification tags, earthing of glands, armouring etc. complete as per specifications as required and as below.
4CX 400 SQMM Aluminium
4CX 240 SQMM Aluminium
4CX 185 SQMM Aluminium
4CX 150 SQMM Aluminium
4CX 120 SQMM Aluminium
4CX 70 SQMM Aluminium
4CX 50 SQMM Aluminium
4CX 35 SQMM Aluminium
4CX 16 SQMM Aluminium
4CX 10 SQMM Copper
4CX 6 SQMM Copper
4CX 4 SQMM Copper
3CX 185 SQMM Aluminium
3CX 6 SQMM Copper
2CX 6 SQMM Copper
LV.CABLE TERMINATION Supplying and fixing , crimping lugs (Al/Cu as required), double compression brass glands, insulation tape etc. complete as per specifications and as required. Note:Termination of different metal shall be done by using bimetallic lugs/terminations.
4C X 400 sq.mm
4C X 240 sq.mm
4C X 185 sq.mm
4C X 150 sq.mm
4C X 120 sq.mm
4C X 70 sq.mm
4C X 50 sq.mm
4C X 35 sq.mm
4C X 16 sq.mm
4C X 10 sq.mm
4CX 6 sq.mm
4C X 4 sq.mm
3CX 185 sq.mm
3CX 6 sq.mm
2C X 6 sq.mm
SWITCHBOARDS Design, fabrication, supply, erection , testing and commissioning of following Cubicle type, fully compartmentalized LT Switchboards IP54 rated, dust tight and vermin proof, fabricated out of 14 SWG CRCA sheet(2mm thickness), chemically treated and powder coating of approved shade. The Switchboards should have a Set of suitably rated electrolytic high conductivity tinned copper busbars with the specified current and fault level having a maximum current density of 1.2A per sq.mm., Insulated with heat shrinkable, color coded PVC FRLS Sleeves and supported using DMC/ SMC Pillar or Finger type busbar supports. The design should be as per the standards of the State Electrical Inspectorate.
MSB(Main Switch Board) -MG ROAD Supply and Installation (including unloading) of Free standing, floor mounting Switchboard fabricated out of 14SWG CRCA sheet with Top Cable entry facility for incomer and outgoing side for 1no 630KVA incomer . 1) Main Busbars: 1000A,50KA TPN Copper Busbars – 1set Earth bus - 32 x 6mm GI strip. 2) Transformer 630KVA Incomer: Air circuit breaker 1000A, 50KA Set 840A Icw 1sec, 4Pole 100% rated Neutral, Electricaly operated drawout type with Shutter Assembly, Remote Control with Open and Close with RS485 port for display of ON/OFF status, current and energy parameters etc of ACB on BMS workstation through Modbus protocol- 1no Metering and Indications 3Phase Digital Combination Meter with Ammeter, KW Meter, PF Meter , 3nos Resin Cast Metering CTs, CL1.0,415V,1000/5, 3nos 2A Control fuses – 1set Three phase KSEB KWH Meter along with 3nos Resin Cast Metering CTs, CL1.0,415V,1000/5, 3nos 2A Control fuses. KWH Meter shall be tested and approved by third party/inspectorate - 1set LED Type Red Yellow Blue (RYB), Red Amber Green (Close/Trip/Open) Indication Lamps with Control fuses and toggle switches – 1set 3Phase Digital Voltmeter 0-500V and 3nos 2A Control fuses – 1set Relays: Stand by Earth fault relay 10-40% 1.3sec IDMT & 200/5 CL:5P10,15VA,415V Resin cast protection CT -1set. Numerical relay 1.3s with 20c, 1EF 50%-200% setting range 1000/5, CL:5P10, 15VA, 415V Resin cast protection CT-1set 3) Outgoing Feeders Moulded Case Circuit Breaker TP, 320A, 25KA Set 250A with microprocessor release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with Indication lamp for ON and OFF status -4nos. Moulded Case Circuit Breaker TP, 320A, 25KA Set 125A with microprocessor release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no KSEB's three phase KWH Meter along with 3nos Resin Cast Metering CTs, CL1.0,415V,150/5 and 3 nos 2A control fuses and Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate -1no. Moulded Case Circuit Breaker TP, 320A, 25KA Set 125A with microprocessor release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with Indication lamp for ON and OFF status -2nos. 250A TPN Isolator – 1no. Provision shall be made for sealing of all shutters.
MSB(Main Switch Board) – ALUVA Supply and Installation (including unloading) of Free standing, floor mounting Switchboard fabricated out of 14SWG CRCA sheet with Top Cable entry facility for incomer and outgoing side for 1no 1000KVA incomer . 1) Main Busbars: 1600A,50KA TPN Aluminium Busbars – 1set Earth bus - 32 x 6mm GI strip. 2) Transformer 1000KVA Incomer: Air circuit breaker 1600A, 50KA Set 1333A Icw 1sec, 4Pole 100% rated Neutral, Electricaly operated drawout type with Shutter Assembly, Remote Control with Open and Close with RS485 port for display of ON/OFF status, current and energy parameters etc of ACB on BMS workstation through Modbus protocol- 1no Metering and Indications 3Phase Digital Combination Meter with Ammeter, KW Meter, PF Meter , 3nos Resin Cast Metering CTs, CL1,10VA 1500/5, 3nos 2A Control fuses – 1set Three phase KSEB KWH Meter along with 1500/5 Resin Cast Metering CT and 3 nos 2A control fuses. KWH Meter shall be tested and approved by third party/inspectorate - 1set LED Type Red Yellow Blue (RYB), Red Amber Green (Close/Trip/Open) Indication Lamps with Control fuses and toggle switches – 1set 3Phase Digital Voltmeter 0-500V and 2A Control fuses – 1set Relays: Stand by Earth fault relay 10-40% 1.3sec IDMT & 250/5 Class 5P10,15VA,415V Resin cast protection CT -1set. Numerical relay 1.3s with 20c, 1EF 50%-200% setting range 1500/5, CL:5P10, 15VA, 415V & 250/5 Class 5P10,15VA,415V resin cast protection CT-1set Reference relay 1500/5, CL:5P10, 15VA, 415V resin cast protection CT-1set 3) Outgoing Feeders Moulded Case Circuit Breaker TP, 500A, 25KA Set 400A with microprocessor release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with Indication lamp for ON and OFF status -2nos. Moulded Case Circuit Breaker TP, 500A, 25KA Set 320A with microprocessor release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with Indication lamp for ON and OFF status -1no. Moulded Case Circuit Breaker TP, 500A, 25KA Set 200A with microprocessor release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with Indication lamp for ON and OFF status -3nos. Moulded Case Circuit Breaker TP, 500A, 25KA Set 200A with microprocessor release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no three phase KWH Meter along with 200/5 Resin Cast Metering CT and 3 nos 2A control fuses and Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate -1no. 250A TPN Isolator – 1no. Provision shall be made for sealing of all shutters.
MSB(Main Switch Board) – JLNS Supply and Installation (including unloading) of Free standing, floor mounting Switchboard fabricated out of 14SWG CRCA sheet with Top Cable entry facility for incomer and outgoing side for 1no 1600KVA incomer . 1) Main Busbars: 2500A,50KA TPN Aluminium Busbars – 1set Earth bus - 50 x 10mm GI strip. 2) Transformer 1600KVA Incomer: Air circuit breaker 2500A, 50KA Set 2133A Icw 1sec, 4Pole 100% rated Neutral, Electricaly operated drawout type with Shutter Assembly, Remote Control with Open and Close with RS485 port for display of ON/OFF status, current and energy parameters etc of ACB on BMS workstation through Modbus protocol - 1no Metering and Indications 3Phase Digital Combination Meter with Ammeter, KW Meter, PF Meter, 3nos Resin Cast Metering CTs, CL1,10VA 2500/5, 3nos 2A Control fuses – 1set Three phase KSEB KWH Meter along with 2500/5 Resin Cast Metering CT and 3 nos 2A control fuses.KWH Meter shall be tested and approved by third party/inspectorate. - 1set LED Type Red Yellow Blue (RYB), Red Amber Green (Close/Trip/Open) Indication Lamps with Control fuses and toggle switches – 1set 3Phase Digital Voltmeter 0-500V and 2A Control fuses – 1set Relays: Stand by Earth fault relay 10-40% 1.3sec IDMT & 500/5 Class 5P10,15VA,415V Resin cast protection CT -1set. Numerical relay 1.3s with 20c, 1EF 50%-200% setting range 2500/5, CL:5P10, 15VA, 415V resin cast protection CT-1set Reference relay 2500/5, CL:5P10, 15VA, 415V resin cast protection CT-1set 3) Outgoing Feeders Moulded Case Circuit Breaker TP, 800A, 25KA Set 630A with microprocessor release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with Indication lamp for ON and OFF status -4nos. Moulded Case Circuit Breaker TP, 800A, 25KA Set 320A with microprocessor release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with Indication lamp for ON and OFF status -1nos. Moulded Case Circuit Breaker TP, 800A, 25KA Set 320A with microprocessor release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no of three phase KWH Meter along with 150/5 Resin Cast Metering CT and 3 nos 2A control fuses and Indication lamp for ON and OFF status.KWH Meter shall be tested and approved by third party/inspectorate. -1no. 250A TPN Isolator – 1no. Provision shall be made for sealing of all shutters.
SSB 1 TO SSB2 -MG ROAD Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet 1) Busbars: 250A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm GI 2) Incomer: 250A TPN isolator - 1no. Meters & Indications: Three phase Digital Meter with 250/5 Class 1.0, 15VA,415V Resin cast metering CT and 3 nos 2A control fuses - 1set. Red, Yellow, Blue LED Indication Lamps along with 3nos2A Control fuses - 1set. 3) Outgoings: 40A TPN MCB along with 1no KSEB's three phase KWH Meter along with Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate – 6nos Provision shall be made for sealing of all shutters.
SSB3 -MG ROAD Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 16SWG CRCA sheet 1) Busbars: 125A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm GI 2) Incomer: 125A TPN isolator - 1no. Meters & Indications: Three phase Digital Meter with 100/5 Class 1.0, 15VA,415V Resin cast metering CT and 3 nos 2A control fuses - 1set. Red, Yellow, Blue LED Indication Lamps along with 3nos2A Control fuses - 1set. 3) Outgoings: Moulded Case Circuit Breaker TP, 80A, 25KA Set 63A with thermal magnetic release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no three phase KWH Meter along with 3nos Resin Cast Metering CTs, CL1.0,415V,75/5 and 3 nos 2A control fuses and Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate -1no. 32A TPN MCB along with 1no KSEB's three phase KWH Meter along with Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate – 3nos Provision shall be made for sealing of all shutters.
SSB 1 – ALUVA Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet 1) Busbars: 315A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm GI 2) Incomer: 315A TPN isolator - 1no. Meters & Indications: Three phase Digital Meter with 300/5 Class 1.0, 15VA,415V Resin cast metering CT and 3 nos 2A control fuses - 1set. Red, Yellow, Blue LED Indication Lamps along with 3nos2A Control fuses - 1set. 3) Outgoings: Moulded Case Circuit Breaker TP, 80A, 25KA Set 63A with thermal magnetic release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no three phase KWH Meter along with 75/5 Resin Cast Metering CT and 3 nos 2A control fuses and Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate -3no. 40A TPN MCB along with 1no three phase KWH Meter along with Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate – 3nos Provision shall be made for sealing of all shutters.
SSB 2 – ALUVA Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet 1) Busbars: 400A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm GI 2) Incomer: 400A TPN isolator - 1no. Meters & Indications: Three phase Digital Meter with 400/5 Class 1.0, 15VA,415V Resin cast metering CT and 3 nos 2A control fuses - 1set. Red, Yellow, Blue LED Indication Lamps along with 3nos2A Control fuses - 1set. 3) Outgoings: Moulded Case Circuit Breaker TP, 80A, 25KA Set 63A with thermal magnetic release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no three phase KWH Meter along with 75/5 Resin Cast Metering CT and 3 nos 2A control fuses and Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate -6no. Provision shall be made for sealing of all shutters.
SSB3 – ALUVA Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet 1) Busbars: 200A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm GI 2) Incomer: 200A TPN isolator - 1no. Meters & Indications: Three phase Digital Meter with 200/5 Class 1.0, 15VA,415V Resin cast metering CT and 3 nos 2A control fuses - 1set. Red, Yellow, Blue LED Indication Lamps along with 3nos2A Control fuses - 1set. 3) Outgoings: Moulded Case Circuit Breaker TP, 80A, 25KA Set 63A with thermal magnetic release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no three phase KWH Meter along with 75/5 Resin Cast Metering CT and 3 nos 2A control fuses and Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate -3nos. Provision shall be made for sealing of all shutters.
SSB 1 TO SSB2 -JLN Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet 1) Busbars: 800A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm GI. 2) Incomer: 800A TPN isolator - 1no. Meters & Indications: Three phase Digital Meter with 800/5 Class 1.0, 15VA,415V Resin cast metering CT and 3 nos 2A control fuses - 1set. Red, Yellow, Blue LED Indication Lamps along with 3nos2A Control fuses - 1set. 3) Outgoings: Moulded Case Circuit Breaker TP, 200A, 25KA Set 160A with microprocessor release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no of three phase KWH Meter along with 150/5 Resin Cast Metering CT and 3 nos 2A control fuses and Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate -4no. Provision shall be made for sealing of all shutters.
SSB 1 TO SSB2 (OPTIONAL) -MG ROAD Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet 1) Busbars: 250A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm GI 2) Incomer: 250A TPN isolator - 1no. Meters & Indications: Three phase Digital Meter with 250/5 Class 1.0, 15VA,415V Resin cast metering CT and 3 nos 2A control fuses - 1set. Red, Yellow, Blue LED Indication Lamps along with 3nos2A Control fuses - 1set. 3) Outgoings: Moulded Case Circuit Breaker TP, 80A, 25KA Set 63A with thermal magnetic release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no three phase KWH Meter along with 3nos Resin Cast Metering CTs, CL1.0,415V,100/5 and 3 nos 2A control fuses and Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate -4no. Provision shall be made for sealing of all shutters.
SSB 1 (OPTIONAL) – ALUVA Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet 1) Busbars: 315A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm GI 2) Incomer: 315A TPN isolator - 1no. Meters & Indications: Three phase Digital Meter with 300/5 Class 1.0, 15VA,415V Resin cast metering CT and 3 nos 2A control fuses - 1set. Red, Yellow, Blue LED Indication Lamps along with 3nos2A Control fuses - 1set. 3) Outgoings: Moulded Case Circuit Breaker TP, 80A, 25KA Set 63A with thermal magnetic release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no three phase KWH Meter along with 75/5 Resin Cast Metering CT and 3 nos 2A control fuses and Indication lamp for ON and OFF status -2nos. Moulded Case Circuit Breaker TP, 125A, 25KA Set 100A with thermal magnetic release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no three phase KWH Meter along with 100/5 Resin Cast Metering CT and 3 nos 2A control fuses and Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate -2nos. Provision shall be made for sealing of all shutters.
SSB 2 (OPTIONAL) – ALUVA Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet 1) Busbars: 400A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm GI 2) Incomer: 400A TPN isolator - 1no. Meters & Indications: Three phase Digital Meter with 400/5 Class 1.0, 15VA,415V Resin cast metering CT and 3 nos 2A control fuses - 1set. Red, Yellow, Blue LED Indication Lamps along with 3nos2A Control fuses - 1set. 3) Outgoings: Moulded Case Circuit Breaker TP, 125A, 25KA Set 100A with thermal release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no three phase KWH Meter along with 100/5 Resin Cast Metering CT and 3 nos 2A control fuses and Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate -6nos. Provision shall be made for sealing of all shutters.
SSB 1 TO SSB2 (OPTIONAL) -JLN Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet 1) Busbars: 800A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm CU. 2) Incomer: 800A TPN isolator - 1no. Meters & Indications: Three phase Digital Meter with 800/5 Class 1.0, 15VA,415V Resin cast metering CT and 3 nos 2A control fuses - 1set. Red, Yellow, Blue LED Indication Lamps along with 3nos2A Control fuses - 1set. 3) Outgoings: Moulded Case Circuit Breaker TP, 400A, 25KA Set 320A with microprocessor release FD KIT, OC, SC, Shunt & Isolation duty Current Limiting type with 1no of three phase KWH Meter along with 150/5 Resin Cast Metering CT and 3 nos 2A control fuses nd Indication lamp for ON and OFF status. KWH Meter shall be tested and approved by third party/inspectorate -2nos. Provision shall be made for sealing of all shutters.
LIFT PNL -MG ROAD Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet. 1) Busbars: 40A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm GI 2) Incomer : 40A TPN Isolator -1 no Meters & Indications: Red, Yellow, Blue LED Indication Lamps along with 2A Control fuses - 1set 3) Outgoings: 25A TPN Miniature Circuit Breaker with Indication lamp for ON and OFF status –4nos
LIFT PNL – ALUVA Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet. 1) Busbars: 40A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm GI 2) Incomer : 40A TPN Isolator -1 no Meters & Indications: Red, Yellow, Blue LED Indication Lamps along with 2A Control fuses - 1set 3) Outgoings: 25A TPN Miniature Circuit Breaker with Indication lamp for ON and OFF status –4nos
LIFT PNL -JLN Supply and Installation (including unloading) of Top cable entry for incoming and outgoing feeders. Fabricated out of 14SWG CRCA sheet. 1) Busbars: 63A TPN Al. Busbar - 1no. Earth bus - 25 x 3mm GI 2) Incomer : 63A TPN Isolator -1 no Meters & Indications: Three phase Digital Meter with 75/5 Class 1.0, 15VA,415V Resin cast metering CT and 3 nos 2A control fuses - 1set 3) Outgoings: 25A TPN Miniature Circuit Breaker with Indication lamp for ON and OFF status –5nos
FIRE PUMP PANEL Fire Pump Panel (FPP) as per specifications & Drawing as per following details complete with contactor based automatic changeover system Fire Pump Panel (FPP) - Type-1 Internal wiring in the Starters shall be done with FR PVC insulated cables of adequate size. Internal wiring, contactors, relay contacts, push button contacts should be rated not less than 2.5 sq mm. INCOMER - I from MSB (Normal Supply) 1 no. 250 A, 415 V, Ics=35kA ,4P, MCCB with variable over current and short circuit releases having: 1 set of Red/Green ON/OFF indicating lamps 1- set of three phase indicating lamps (red, yellow, blue) Amber trip indicating lamps BUSBAR Electrolytic high conductivity tinned copper three phase and neutral busbars rated at 250 A having a maximum current density of 1.4 A per sq mm suitable to with stand symmetrical fault level of 35kA at 415 V. The neutral busbar is to be of capacity as phases Two incomers shall be interlocked electrically & mechanically with contactor based automatic changeover system so that only one supply is switched on at a time. OUTGOING 1 no. 100 HP, Star Delta starter comprising 3 Nos. TP contactor AC-3 duty Auto/Manual switch, Start Stop push button, microprocessor based over current relays single phasing preventer and timer & with potential free contacts for remote monitoring and control.
MOTOR STARTERS Wall mounting type dust tight and verminproof, fabricated out of 16 SWG CRCA sheet, treated and painted with 2 coats of primer and two coats of paint and shall include the following with TPN isolator & illuminated LED type ON Off push buttons, Contactors, Overload Relays, Power terminals, Control Terminals Power and Control Wiring etc. with the following DOL and STAR DELTA STARTERS
6 HP, Star Delta starter comprising 3 Nos. TP contactor AC-3 duty Auto/Manual switch, Start Stop push button, bimetallic over current relays single phasing preventer and timer & with potential free contacts for remote monitoring and control.
10/7.5 HP, Star Delta starter comprising 3 Nos. TP contactor AC-3 duty Auto/Manual switch, Start Stop push button, bimetallic over current relays single phasing preventer and timer & with potential free contacts for remote monitoring and control.
D.G.SET ERECTION-100kVA Erection, Testing and commissioning of 100KVA 415Volts, 3Phase, 50c/s, Diesel Engine coupled Alternator working at 0.8 p.f. comprising of Starting equipment for the Diesel Engine and including the following. Fixing of anitvibration mountings for the D.G.Set. Fixing of battery including supply of battery stand. Assembly & Installation of Acoustic enclosure for DG Set Fuel line for the diesel engine. Fixing of residential silencer for the engine. Erection of Generator Control Panel Supply and fixing of MS exhaust line of 70m length shall be suitably cladded with aluminium sheets,mineral wool etc.The silencer schould be of residential type. Flexible connection(expansion joints)shall be provided in the exhaust piping to avoid transmission of vibration from engine to the structure(acoustic and weather proof enclosure etc.).Also the exhaust line with suitable bends,collars,flanges,angle supports and other accessories should be provided.Provide necessary arrangements to avoid entry of rain water,falling dust etc.at the top of the exhaust pipe.The exhaust piping system should be designed as per the controller pollution board standards. (The Client will supply only the D.G.set, enclosure, antivibration mountings, battery, residential silencer and fuel tank). All other items shall be supplied by the Contractor
Supply and fixing of MS exhaust line for 100KVA DG Set.
D.G.SET ERECTION-125kVA INSTALLATION Installation/Erection, Testing & Comissioning including Integrated Testing with all systems for the DG sets along with all accessories as given in Detailed BOQ for the following Capacity DG sets 125KVA DG set
EXHAUST PIPING "Design, Manufacture, Supply, Installation/ erection, testing and commissioning of exhaust piping of Class ""B"" MS(4.85 mm thick as per IS 1239) of suitable size as recommended by the Engine manufacturer including the cost of pipe supports, bends, flexible joints and insulation etc. complete as per tender specifications. The Length will be taken beyond the Exhaust Selencer of the Engine. " For DG sets upto 250 KVA ratings
EARTHING. PLATE EARTH STATION. Providing and making plate earthing station including the cost of 600 mm x 600 mm x 6.3 mm G. I. plate electrode, 15 mm dia G.I.watering pipe, CI funnel with wiremesh charcoal/coke , salt, all earth work, masonry enclosure with frame, Heavy duty RCC top cover plate having locking arrangement,Disconnecting links, complete as per IS 3043:1987 for earthing. Supply / Installation / Erection:
EARTHING CONDUCTORS. Supply, instalaltion and testing of 8 SWG GI wire for Earthing Purpose
Supply and laying,Testing and commissioning of copper/GI Strips/wire for interconnecting the earthing stations ,panels,DBs etc. of the following sizes in built up trenches /surface/wall/ground complete with holes & fixing,jointing / terminating accessories as per specifications & drawing as required. (Quantity shall be paid as per the actual measurement as executed, however direct measurement shall not excced the quantity indicated in drawing approved .
25x3mm GI Strip. Supply / Installation / Erection:
32x6mm GI Strip. Supply / Installation / Erection:
50x6mm GI Strip. Supply / Installation / Erection:
50x10mm GI Strip. Supply / Installation / Erection:
BUSBAR TRUNKING Design, manufacture, testing at works, supplying, Installation, testing of sheet steel structure following rating (Amps) Sandwitch type TPN "Al" bus duct (as per specifications) having neutral cross section equal to phase, 50% Integral earth which is part of housing itself and class F insulation and enclosure will be of minimum 1.6 mm CRCA sheet steel epoxy powder coated. The bus bar will be of Al with radialised edges. Individual sections will not be more than 3 meters long uniblock. One section will be connected to adjacent section by joint system operating by single bolt. Sub assembly will removable with out disturbing the adjacent bus bars. Rates shall be inclusive of all accessories i.e. bends, end feed box/adaptor box etc. as required. 2500A Sandwich Bus duct With short circuit withstand of 50kA for One sec
HOT DIPPED GI CABLE TRAYS & ACCESSORIES Supply, fabrication & installation of perforated hot dipped galvanised double bended cable trays from 2 mm thick GI sheets continuously connected including horizontal and vertical bends, reducers, tees, and other accessories and duly suspended from the ceiling with 12 mm dia vertical GI rods supported by 40mm x 40 mm x 5 mm GI angle etc. (or installed on wall supported on suitable brackets as required) complete as per specifications, as required and as below. Note: Trays shall be supported adequately at minimum 1 m distance from the building structure / ceiling by means of painted / galvanized (as specified) MS structural members secured to the structure by dash fasteners or by grouting. This support should be capable of withstanding the weight equivalent of 3m length of the cables that can be laid in the trays. At turns the support has to be double and at both ends of the bend.
600 mm width X 40 mm depth X 2.0 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
300 mm width X 40 mm depth X 2 mm thickness
MISCELLANEOUS ITEMS. Supply and fixing of the following safety equipments in Aux. Sub.Station/MDB room as per detailed descriptions given below and as per relevant IE rules & code of standard practice 1000 mm wide Insulating mat,confirming to IS 15652-2006 suitable to withstand 11 kV in front of all panels in ASS building & Pump room as required. Laminated standard shock treatment charts in English & Hindi in ASS, ESR, DG room and Pump room in each station. Danger plate as per approved Style & sample written in English & Hindi for MV installations as required as per IE rules, IES and IS 2551 (latest) - 8 nos. per station 2 nos. per station First Aid Box Complete as approved by St. John ambulance or Indian Red Cross. 4 nos. per station of 3-fire-buckets set each painted red with 'fire' written complete with sand filling, floor/wall mounting brackets/stand complete as per elevant IS and as required. One Tool kit per station comprising 1 set of flat spanner (Taparia / Jalan), 1 set of box spanner, 1 no. Hacksaw frame with 10 No. blades, 1 no. large, medium, small screw drivers, 1 no. insulated plier, 1 no nose plier, 1 no. hand crimping tool upto 16 sq.mm, 1 no. digital multimeter, 1 no. test lamp and 1 no. tester. Screw driver set for all types of screw heads also to be provided.
FIRE PROTECTION AND FIRE DETECTION SYSTEM
FIRE PUMP &ACCESSORIES
Supply, installation and testing of fire pumps, electrically driven generally as specified and shown in equipment schedule complete with: a)all accessories, b)vibration mounts & c)test connection excluding starter panel Sprinkler Main Fire Pumps Providing and fixing horizontal single stage, single outlet pumping set with bronze impeller, C.I. body and connected by a flexible coupling to a totally enclosed fan cooled induction motor mounted on a common M.S. structural base plate with RCC (RCC by civil contractor) base and with all pump accessories, including pressure switch, pressure guage (both with cut off ball valves) complete as per specifications. Motor to be suitable for 415V, 3-phase, 50 Hz AC supply (specifications as per fire fighting requirements and on the pattern of local authority approval) as per instruction and specifications. Factory Acceptance Test (FAT) should be carried out before dispatching the pumps from factory. Capacity : 2850 lpm App.head : 90 m App. HP :100 HP RPM : 2900
Fire Jockey Pumps Supplying, installing, testing, & commissioning of electric driven automatic pressurisation pump set consisting of the following. Vertical mounted multi stage centrifugal Jockey pump. Squirrel cage induction motor suitable for 415 V, 50Hz, AC supply of the above pump with synchronous speed of 2900 RPM T.E.F.C type such as confirming to IP:55 and including pressure switch, pressure guage ( both with cut off valves ) complete as per specifications, flexible coupling and coupling guard with the pump. Common bed plate of fabricated mild steel channel or cast iron type. Factory Acceptance Test (FAT) should be carried out before dispatching the pumps from factory. Capacity : 180 lpm App. Head : 90 m App. H.P. : 10 HP RPM : 2900
Providing & fixing pressure gauges of not less than 100mm dia dial of pressure range 0-14 kg/cmsq complete with syphon tube and shut off valve duly calibrated before installation.
Providing & fixing Pressure Switch in the M.S. Pipe Line including connection etc. as required.
Supply, fabrication & laying heavy grade IS marked mild steel piping conforming to IS 1239 and IS 3589 complete with M.S. fittings, pipe supports, clamps, painting of two coats of red enamel etc. as approved with welded jointing for Wet Riser system.
250 mm Dia
200 mm Dia
150 mm Dia
100 mm Dia
80 mm Dia
65 mm Dia
50 mm Dia
40 mm Dia
32 mm Dia
25 mm Dia
Supply, installation, testing and commissioning of Expansion bellows (Flexible coupling) with required flanges,nuts,bolts &accessories
150 mm Dia
100 mm Dia
80 mm Dia
65 mm Dia
50 mm Dia
40 mm Dia
32 mm Dia
Supplying, Installing, testing and commissioning CI Butterfly valve slim seal standard lever operated type confirming to IS 13095 with required flanges, nuts, bolts etc. complete.
150 mm Dia
100 mm Dia
80 mm Dia
65 mm Dia
50 mm Dia
40 mm Dia
Supply, installation, testing and commissioning of C.I. Non-Return Valve slim seal with required flanges, nuts & bolts, gasket etc. complete
250 mm Dia
200 mm Dia
150 mm Dia
100 mm Dia
80 mm Dia
65 mm Dia
50 mm Dia
40 mm Dia
Supply, installation, testing and commissioning of C I Gate Valve with required accessories
80 mm Dia
65 mm Dia
50 mm Dia
40 mm Dia
32 mm Dia
25 mm Dia
20 mm Dia
15 mm Dia
Supply, installation, testing and commissioning of C.I 4 Bolts Frictionless Foot Valve with strainer screwed as per IS:4038, Lift type, body seat ring of Gun Metal. and Neoprene rubber seated Disc for 100% leak proof with required flanges, nuts, bolts and gaskets etc. complete.
150mm Dia
100mm Dia
80mm Dia
65 mm Dia
50mm Dia
40 mm Dia
FIRE HYDRANT SYSTEM
Supply, fabrication & laying heavy grade IS marked mild steel piping conforming to IS 1239 and IS 3589 complete with M.S. fittings, pipe supports, clamps, painting of two coats of red enamel etc. as approved with welded jointing for Wet Riser system.
150 mm Dia
100 mm Dia
80 mm Dia
65 mm Dia
25 mm Dia
Supply, fabricating, laying, testing, painting and commissioning external piping (UNDERGROUND) generally as specified using heavy class M.S. conforming to IS1239 with all fittings at a depth of 1.0 M all complete with one protection layer of 4mm thick Pypkote or similar. i) All pipes and all heavy grade fittings conforming to IS 1239 together with welded joints, flanges, gaskets, bolts & nuts, washers, fittings, adapter pieces etc.
150 mm nominal bore
100 mm nominal bore
80 mm nominal bore
Excavation as per general profiles and back filling for all kinds of soil.
Supplying and fixing stainless steel Single headed hydrant valve with 1 no. 63 mm dia instantaneous FM Stainless steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Stainless steel cap and chain, nuts, bolts, rubber gaskets etc. as required.
Providing and fixing 63 mm dia standard stainless steel short Branch Pipe as per IS 903 with 20 mm nozzle complete with fixing clamps.
Providing & fixing non-perlocating Synthetic fire Hose as per IS 636/1988,BS:6391 with UL of 63 mm dia and 15 m length as described below. The hose shall be rated for burst pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked gun metal male & female coupling (IS:903) bound & rivetted to hose pipe with copper wire (Location : Internal fire hydrant)
Providing and fixing controlled perlocation fire hose pipe (as per IS:8423) of 63 mm dia and 15 meter length rated for brust pressure of 35.7 Kg/sqcm. The hose shall be tested for flame resistance test in accordance to IS:8423. Hose shall be complete with ISI marked brass male & female coupling (IS:903) bound & reveted to hose pipe with copper rivets & 1.5 mm copper wire (Location : External fire hydrant)
Supply and fixing of mild steel hose cabinet of size 900 mm x 600 mm x 400 mm made of 2mm thick, with 6mm thick glazed glass doors including necessary locking arrangements suitable to accomadate external hydrants, 2 nos 63mm dia synthetic hose pipe, 15 m long, 1 no branch SS pipe with 4 nos MS angle (40x40x8) supports grouted in flow and duly coated with post office red external and white internal paint complete in all respects.
Supplying and fixing First-Aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with upto date amendments, complete with the following as required. i) 45 meter, 25 mm (nominal internal) dia water hose Thermoplastic(Textile reinforced) Type- 2 as per IS: 12585. ii) 25 mm (nominal internal) dia gun metal globe valve & 7 mm shut off nozzle. iii) Drum and brackets for fixing the equipments on wall. iv) Connections from riser with 40 mm dia stop valve (gun metal) & M.S. Pipe.
Supplying, Installing, testing and commissioning CI Butterfly valve slim seal standard lever operated type confirming to IS 13039 with required flanges, nuts, bolts etc. complete.
150 mm Dia
100 mm Dia
80 mm Dia
65 mm Dia
Providing, fixing, testing & commissioning of MS air cushion tank on top of each riser fabricated from 6 mm thick MS plate, 200 mm in diameter and 1.2 m in height with dished ends of 8 mm thick MS plate with air release vlave , stop cock flanged inlet connection and drain arrangement wiht 25 mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS 4736-1968 painting the vessel piping etc. with two coats of anticorrosive primer inside and outside , epoxy paint inside, two coats of postal red enamel outside of approved make.
Providing, fixing, testing and commissioning of air vessel tank made frorn 6 mm thick M.S. plate of 450 mm dia & 2m height with dished ends of 8 mm thick, supporting legs, inlet & outlet flanged connections pressure switches with valve to operate as per operating squences including 80 mm dia drain valve, air release valve with stop cock on the top Duly painted with two coats of anticorrosive primer inside and outside , epoxy paint inside, two coats of postal red enamel outside of approved make and outside complete as required.
Supply, fabrication (as per code), installation, testing and commissioning of Air vessels 300mm diameter and 1000mm high with ball valve inlet/outlet valve drain, air release valve, valve air inlet etc. all complete.
Supply, fabrication (as per code), installation, testing and commissioning of Pressure vessels 450mm diameter and 1000mm high fabricated from 8-10mm M.S. plate with accessories inside painting with epoxy paint and outside with enamel.
Providing and fixing standard firemans axe with heavy rubbber handle IS: 726.
Providing & fixing pressure gauges of not less than 100mm dia dial of pressure range 0-14 kg/cmsq complete with syphon tube and shut off valve duly calibrated before installation.
Supply, installation, testing and commissioning fire brigade connection with 4 way 63mm valves inlets, stand post and 150 mm MS pipe for mounting the stand post etc. as specified all complete as approved on tank. Note: The drawings of the proposed arrangement shall be provided by the contractor for approval of employer's representative.
Providing and fixing inlet breeching having C.I. body 4 way Gun metal 63 mm dia instantaneous inlets conforming to IS 905 fitted with non retrun valves 25 mm dia gun metal drain cock, blank cap, brass chains and 150 mm dia flanges with all accessories suitable for local fire tender complete as required.
Supplying and fixing of stainless steel hose cabinet of size 900 mm x 600 mm x 400 mm made of 2 mm thick with 6mm thick glazed glass doors including necessary locking arrangement suitable to accommodate external hydrants, 2 nos 63mm dia synthetic hose pipe 15 m long, 1 no branch S.S. pipe with 4 nos MS angle ( 40 x 40 x 8 ) supports grouted in floor and duly coated with post office red external and white internal paint complete in all respects.
SPRINKLER SYSTEM
Supply, fabrication & laying heavy grade IS marked mild steel piping conforming to IS 1239 and IS 3589 complete with M.S. fittings, pipe supports, clamps, painting of two coats of red enamel etc. as approved with welded jointing for Wet Riser system.
150mm Dia
100mm Dia
80 mm Dia
65 mm Dia
50 mm Dia
40 mm Dia
32 mm Dia
25 mm Dia
Supply, installation, testing and commissioning of approved make 3mm bulb quick response 15mm brass Sprinkler heads designed to operate at 68 deg. Celcius etc. with necessary fittings etc, complete
Pendent Type
Upright Type
Supply, installation, testing and commissioning of approved make 3mm bulb quick response 15mm brass Sprinkler heads designed to operate at 79 deg. Celcius etc. with necessary fittings etc, complete
Pendent Type
Side wall Type
Upright Type
Supplying, Installing, testing and commissioning CI Butterfly valve slim seal standard lever operated type confirming to IS 13039 with required flanges, nuts, bolts etc. complete.
150 mm Dia
100 mm Dia
80 mm Dia
65 mm Dia
50mm Dia
40 mm Dia
Supply, installation, testing and commissioning of C.I. Non-Return Valve slim seal with required flanges, nuts & bolts, gasket etc. complete 150 mm Dia
Providing and fixing sprinkler drain with 25 mm dia ball valve.
Providing & fixing pressure gauges of not less than 100mm dia dial of pressure range 0-14 kg/cmsq complete with syphon tube and shut off valve duly calibrated before installation.
Supply, installation, testing and commissioning of 150 mm dia Installation Control Valve inclusive of 1 no. 150 mm dia Butterfly Valve, trainer, Alarm Valve with Water Motor Gong, Pressure Gauges, Test Lines with Ball Valves with necessary GI (H) piping with threaded fittings of required pipe sizes complete. The item also includes providing and fixing 100 mm dia Pressure Gauges on Sprinkler Headers including Ball Valves, Test Control Box, brass strainer, retard chamber.
Providing and fixing UL listed Flow Switch of 40/50/80 / 100 / 150 mm dia on Sprinkler Header complete with flexible full bore paddle, U clamp and NO / NC contact terminals
Making Circular Holes for drawing Pipes of necessary size in Steel Reinforced Cement Concrete ensuring minimum structural steel members are cut or disturbed, Refilling, pressure grating and leak proofing the Gaps using Rich Concrete and Liquid Polymer Leak arrester
40 mm Dia Holes
50 mm Dia Holes
65 mm Dia Holes
80 mm Dia Holes
100 mm Dia Holes
150 mm Dia Holes
200 mm Dia Holes
Providing and fixing M.S. structure work fabricated from standard sections e.g. MS square bars, flat, rounds, angles, channels including cutting to size drilling, welding, fixing & welding to insert plates in RCC structure members as directed by Site Incharge, including cutting and making good the walls, floors & RCC roof (only fo pump room pipe supports, clamps, M.S. ladders & manholes for tank covers etc) including painting with two or more coats of synthetic enamel paint of approved colour over two coats of approved Steel Primer as per drawings & direction of the Site Incharge. (for pipes along ceiling and sprinkler pipes only).
FIRE EXTINGUISHERS AND BUCKETS
Supply and fixing of approved make Carbon-di-oxide Water type Fire extinguishers of 9Kg capacity, Co2 filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel, with wheel type valve, discharge nozzle, bend & horn wall mounting bracket etc., confirming to IS 15683.
Supply and fixing of approved make Carbon-di-oxide Gas type Fire extinguishers of 4.5 Kg capacity, Co2 filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel, with wheel type valve, discharge nozzle, bend & horn wall mounting bracket etc., confirming to IS 2878.
Supplying, and fixing of Dry chemical powder type fire extinguisher of 5 Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, discharge hose, wall mounting bracket etc. complete, confirming to IS:2171.
Providing and fixing set of 4 fire buckets capacity 9 ltrs fabricated from 24 gauge MS sheet brackets filled with jamuna sand, two coats of anti corrosive paint inside and outside and two coats of white enamel inside and two coats of postal red enamel outside with " FIRE" marked on each bucket, including M.S. fabricated 4 bucket standard size with 4 hooks. For Hanging buckets including painting with two coats of anti corrosive primer and two coats of postal red enamel on all surfaces of approved quality and make complete in all respects.
Providing and fixing wall mounted Exit signages consisting of Zinc sulphide photo Luminescent boatings on acrylic sheet signages shall be 15cm x 30 cm and shall consists of Signage on half side and arrow on other half signage shall be any of the following Exit/ Staircase/ Extinguisher location / Manual call box/ Hydrant etc.
ANALOGUE ADDRESSIBLE FIRE DETECTION & ALARM SYSTEM
Supply, installation, testing & commissioning of Analog Addressable Fire Alarm Control panel with battery back up for 8 hours normal operation and 15 minutes alarm operation. The control panel, battery charger etc, shall be UL listed. The panel shall consisting with 80 character LCD display and RS 485 for networking. Panel shall be 1 working loop + 1 spare loop capacity.
Supply, installation, testing & commissioning of Analog Addressable Fire Alarm Control panel with battery back up for 8 hours normal operation and 15 minutes alarm operation. The control panel, battery charger etc, shall be UL listed. The panel shall consisting with 80 character LCD display and RS 485 for networking. Panel shall be 2 working loop + 1 spare loop capacity.
Cost for addition of extra Loop cards in to the panel mentioned above.
Supply and installation of software for programming( mapping) the Fire detection and voice alarm system through FACP / Lap top. The software shall consisting with facility like Upload / down load of informations to FACP, Graphics compatible to autocad, Detectors information with change in address / sensitivity etc as required.
Supply, installation, testing and commissioning of plug-in type addressable analogue photoelectric smoke detectors above false ceiling including the cost of base plate, 75 mm dia M.S. outlet box for fixing of the detector base, mounting accessories etc. complete as per specifications and as required.
Supply, installation, testing and commissioning of Response Indicator Lamp assembly in a dust tight sheet steel enclosure as per detailed specifications including accessories for recess mounting as per approved sample as required.
Supply, installation, testing and commissioning of Fault Isolator Modules including the cost of mounting accessories complete as per specifications and complete as required.
Supply, installation, testing and commissioning of Control Modules including the cost of mounting accessories complete as per specifications and as required.
Supply, installation, testing and commissioning of Monitor Modules including the cost of mounting accessories complete as per specifications and as required.
Supply, installation, testing & commissioning of Line Isolator. as per the standard specification
Supply, installation, testing & commissioning of Hooter cum Speaker with 4 Watt Speaker and Line Matching Transformer of minimum 100 dB at 10 M distance with necessary access to complete
Supply installation testing and commissioning of dust and vermin proof addressable analogue Manual Call Boxes to initiate audio visual alarm including the cost of mounting accessories complete as per specifications and as required.
Supply, installation, testing & commissioning of 24V10A Switch mode power supply unit with battery with necessary accessories
Supplying, installing, testing and commissioning of cabling for fire detection and alarm system with 2 core annealed tinned copper conductor PVC sheathed, flexible, FR 2 x 1.5 sq mm cables as per specifications in existing conduits complete as required
Supplying, installing, testing and commissioning of following sizes 16 gage GI conduits recessed/surface as required including clamps, hardwares etc required for conduiting arrangement complete as per specifications. (No additional price shall be payed for GI flexible conduits used to take fire cabling from actual ceiling to false ceiling wherever required)
20mm GI pipe
25mm GI pipe
32mm GI pipe
40mm GI pipe
Supply, installation, testing & commissioning of Addressable Fully Functional Fire Alarm Repeater Panel with Minimum 80 Character Complete with Power supply and RS485 Network Cards and all Accessories.
Control wiring from Fire Pump Panel / Local Panel to remote Push Button in Control Room with 6C X 1.5 sq mm Cu. Wire laid 1.0m below ground.
Supply & installation of remote ON/OFF push button stations for fire pumps and Pump Status Repeater panel in fire control room. Repeater panel shall be four station Fire Pump Repeater Panel with pilot lamp per pump and common piezo and accept switches.
Supply, installation, testing and commissioning of Wall/ Ceiling mounting strobes for visual indication including the cost of mounting accessories complete as per specifications and as required.
Supply, installation, testing and commissioning of wall or ceiling mounted 240 Volt AC illuminated double sided pictorial exit signs provided with appropriate direction arrow painted in green on white with an 11W CFL Lamp including the cost of in-built rechargeable batteries with charger suitable for 90 minute operation and including the cost of accessories for surface/ recessed or ceiling suspended mounting complete as required.
Supplying, laying and connecting of single pair PVC insulated twisted 32/0.2 mm dia copper conductor cable for speakers in conduit for hooter cum speakers .
Supply, laying, testing and commissioning of 4 pair 2.5 sqmm screened copper armoured cable for outdoor use complete with providing sand cushioning brick protection etc.
Supply, laying, testing and commissioning of 4 pair 2.5 sqmm screened copper armoured cable in existing cable trays complete as required.
Supplying , laying , testing and commissioning of 6 core 2.5 sqmm copper armoured cable for outdoor use complete with providing sand cushioning and brick protection etc.
Supplying, laying, testing and commissioning of 50 core 1.5 sqmm copper conductor armoured cable for outdoor use complete with providing sand cushioning and brick protection etc.
Supply installation testing and commissioning of addressable analogue Talk Back jacks with face plates for Fireman's Handsets to initiate audio conversation with Main Fire Alarm Panel including the cost of mounting accessories complete as per specifications and as required.
PANEL FLOODING TUBE SYSTEM
Supply, fixing, testing and commissioning of Polymer Tube Detection based CO2 System for Electrical Panels (Firetrace Tube Panel Protection System), consisting of the following components: Note: The items indicated above are notable items. The vendor to include all allied and implid items in required quantity at no extra cost.
CO2 Cylinder, 8 kg capacity, complete with all necessary CO2 Gas, fittings, support and accessories, connected with Valve (with manual release facility).
CO2 Cylinder, 4.5 kg capacity, complete with all necessary CO2 Gas, fittings, support and accessories, connected with Valve (with manual release facility).
Filling Adapter
Outlet adapter
End of Line adapter
Pressure switch
Flexible Polymer Detection Tube with all necessary fittings & supports.
Master Control Unit for controlling each system, complete with pressure switches, buzzers and electronic hooters, including all necessary accessories + electrical wiring to make each entire system functional.
Auto weight measuring Unit for Cylinders with automatic audio/visual alarm.
AMC CHARGES
3rd Year of installation
4th Year of installation
5th Year of installation
CAPITAL EQUIPMENTS: Design, Manufacture & Supply of DG sets along with all accessories with (AMF Panel) as given in Detailed BOQ for the following capacity DG sets
DG Set 100KVA with Enclosure
DG Set 125KVA with Enclosure
3KVA UPS
Supply, Installation , testing & commissioning of 3 KVA True online double conversion UPS system, 12V with required 5no of SMF battery, 7 static bypass switch (SBS) for emergency load backup for 15min .Efficiency >95%, THDV<2% with linear loads and 3% with non linear loads.
HENRY AND FARAD PVT. LTD.
Kool Home Builders
Allies Fire Systems Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .