Loading…
Loading…
Tender Value
₹20.9 L
EMD Value
₹41,800
Closing Date
21 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
MAINTAINCE
12 conditions · 1 needing a document upload
The firm/contractor should submit a valid "B" grade or above electrical Contractor license issued by the Government Electrical Licensing Board in favor of the Firm/contractor (OR) the site Supervisor should possess the necessary valid "B" grade or above electrical Contractor license issued by Government Electrical Licensing. A copy of the valid license shall be submitted with the offer. The offer without a copy of a valid "B" grade or above Electrical Contractors license shall be summarily rejected.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
46 conditions · 6 needing a document upload
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society /Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. and corresponding documents shall be submitted by the tenderer as per the composition of the Firm.
The Bid Security shall be deposited either in cash through e- payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA of GCC and shall be valid for a period of 90 days beyond the bid validity period. Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document within 5 working days of deadline of submission of bids.
Eligibility criteria :- Eligibility criteria shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document.
Tender Form (First sheet, Second sheet) of The GCC April 2022.
Certificate format (Affadivit) which available as Annexure - V in Mandatory documents. A facility has already created for online submission of Annexure V of GCC in IREPS module, uploading of physically signed Annexure V by tenderer has been discontinued.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society /Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.
The corresponding documents shall be submitted by the tenderer as per the composition of the Firm: Sole Proprietorship Firm: (i) All documents in terms of Para 10 of the Tender Form (Second Sheet) above. HUF: (i) A copy of a notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above. Partnership Firm: (i) All documents as mentioned in para18 of the Tender Form (Second Sheet). Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above. LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet). Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents andcreate liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.
The tenderer shall be required to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as per Clause No.5 of PART -1 of The GCC, April 2022.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Guntakal Division-Provision of lifts on the Foot Over Bridges of Raichur and Yadgir railway stations - Power supply arrangements.
GTL-EM-10-2026-27
GTL-EM-10-2026-27
Open
Works - General
6 Months
Anantapur, Andhra Pradesh
₹0
₹41,800
21 May 2026
29 Apr 2026
7 May 2026
91 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 20,89,866.32 | ||
| — | Item Breakup | for details. | — | ||
| Supply fixing connecting and comissioning of 12 way SPN Distribution board 12 module of model no. 507612 with metal door of legrand make or equivalent make comprising of the following switchgear of make with all connecting accessories complete. | — | — | — | 10,368 | |
| — | Item Breakup | for details. | — | ||
| Supply, fixing and comissioning of of 4 way 8+12 modules DB with IP 54-IK 09 of incommer of MCCB upto 100Amps and outgoing for 12 Module with busbar din and neutral link of Model No.507690 of Legrand with all necessary accessories complete. | — | — | — | 61,648 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of 63A, C-curve 3P MCBs with 10KA breaking capacity with all necessary accessories complete. | — | — | — | 24,948 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of 32A, C-curve 3P MCBs with 10KA breaking capacity with all necessary accessories complete. | — | — | — | 17,064 | |
| — | Item Breakup | for details. | — | ||
| Supply and fixing of 40/50/63 A A 4P MCB C Curve, 10 KA capacity with necessary connections and all accessores complete. | — | — | — | 22,192 | |
| — | Item Breakup | for details. | — | ||
| Supply and fixing of C curve DP MCBs of 32/25/20 A with all connected accessories as per IEC 60898-1 with its latest amendments. | — | — | — | 3,488 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of B curve 6A SP MCBs of Rated Short-Circuit Breaking Capacity 10kA of IP 20 Protection as per IS/IEC 60898 - 1 with its latest amendments including all connected accessories. | — | — | — | 2,760 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of B curve 10A SP MCBs of Rated Short-Circuit Breaking Capacity 10kA of IP 20 Protection as per IS/IEC 60898 - 1 with its latest amendments including all connected accessories. | — | — | — | 2,760 | |
| — | Item Breakup | for details. | — | ||
| Supply, Erection, Testing and Commissioning of RCCB 4P 63A 300mA Sensitivity conforming to IS 12640 (Part 1) : 2024 with 10 kA short circuit withstand capacity, with all necessary accessories complete as advised by the site supervisor. | — | — | — | 15,159.6 | |
| — | Item Breakup | for details. | — | ||
| Supply and running of 32 mm dia, Ivory coloured PVC conduit of wall thickness not less than 2 mm with junction boxes, bends and all accessories etc as required as per site requirement. Running of conduit, fixing with suitable clamps and nuts in groove / open /shelter | — | — | — | 23,708 | |
| — | Item Breakup | for details. | — | ||
| Supply and Running of 25 mm dia, Ivory coloured PVC conduit ( ISI marked) of wall thickness not less than 2 mm along with junction boxes, bends and all accessories etc. as required as per site requirement. Running of conduit, fixing with suitable clamps and nuts in groove / open /shelter | — | — | — | 38,912 | |
| — | Item Breakup | for details. | — | ||
| Cutting of groove in the wall,plastering of surface to the original forc oncealing of the conduit in the wall(Laying and fixing of conduit will bepaid separately) | — | — | — | 8,400 | |
| — | Item Breakup | for details. | — | ||
| Supply, laying, connecting & commissioning of single core multi strand 1.5 sq. mm FRLS Cu. Conductor | — | — | — | 9,000 | |
| — | Item Breakup | for details. | — | ||
| Supply and run of 2 nos, 2.5 sqmm, 1100 V PVC (FRLS) insulated flexible copper conductor wires and one run of 1.5 sqmm PVC (FRLS) insulated flexible copper cable for earthing in existing PVC conduit Pipe conforming to IS 694 (2010) with latest amendments. | — | — | — | 81,600 | |
| — | Item Breakup | for details. | — | ||
| Supply and run of 2 nos, 4.0 sqmm, 1100 V PVC (FRLS) insulated flexible copper conductor wires and one run of 2.5 sqmm PVC (FRLS) insulated flexible copper cable for earthing in existing PVC conduit pipe conforming to IS 694 (2010) with latest amendments. | — | — | — | 30,800 | |
| — | Item Breakup | for details. | — | ||
| Supply and running of 3 core 2.5 Sqmm Copper flexible cable conforming to IS 694 (2010) with latest amendments. | — | — | — | 29,200 | |
| — | Item Breakup | for details. | — | ||
| Supply and fixing of metal flush box-12 module of model no:JIM 12 008 of GM FOURFIVE make or its equivalent with 12 module cover plate (With support frame) of model no:PK SB 12 007 - CASABLANCA of GM make or equivalent make comply with IEC 60669-1 with its latest amendments including all accessories complete. | — | — | — | 11,676 | |
| — | Item Breakup | for details. | — | ||
| Supply and Fixing of metal flush box-8 module of model no:JIM 08 005/6 of GM FOURFIVE make or its equivalent with 8 module cover plate (With support frame) of model no:PK SB 08 011 - CASABLANCA of GM make or equavalant make comply with IEC 60669-1 with its latest amendments including all accessories complete. | — | — | — | 8,640 | |
| — | Item Breakup | for details. | — | ||
| Supply and fixing of metal flush box-4 module of model no:JIM 04 003 of GM FOURFIVE make or its equivalent with 4 module cover plate (With support frame) of model no:PK SB 04 004 - CASABLANCA of GM make or equavalant make comply with IEC 60669-1 with its latest amendments including all accessories complete. | — | — | — | 3,568 | |
| — | Item Breakup | for details. | — | ||
| Groove Cutting for Modular SwitchBoards (Each=1Module) | — | — | — | 5,570.72 | |
| — | Item Breakup | for details. | — | ||
| Supply and fixing of of Modular Dummy Plate for modular switch boards | — | — | — | 796.8 | |
| — | Item Breakup | for details. | — | ||
| Supply, running and connecting of 4 core 16 sq.mm. PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 with its latest amendments. | — | — | — | 3,75,144 | |
| — | Item Breakup | for details. | — | ||
| Supply, Laying, Testing and Termination of 1.1 KV Grade 4 core 50 sqmm XLPE insulated PVC sheathed Aluminium armoured cable as per IS 7098(Part 1)1988 with latest amendments and with necassary lugs and terminations complete. | — | — | — | 2,75,744 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of HDPE pipe of 63 mm of PE-80 grade in PN-4 size as per IS 4984-2016 with latest amendments and with suitable couplings and clamps for cable laying with all necessary accessories complete. | — | — | — | 88,000 | |
| — | Item Breakup | for details. | — | ||
| Supply and laying of 8 SWG GI wire with 40GSM Zink coated, conforming to IS:280- 2006 or latest, it is to be laid with armourd cable for earth continuity. | — | — | — | 9,600 | |
| — | Item Breakup | for details. | — | ||
| Excavation of cable trench in all types soils of size 400mm wide x 1 mtr. deep, and making good of the same to its original form and shape after complete including all connected materials and works up to the satisfaction of the Engineer at Site and also as per R.B JPO no: No.2003/Tele/RCIL/I Pt.IX dated 24.06.2013 The exact route of the HT/LT cable is to be decided in consultation with Engineer in charge. | — | — | — | 15,042 | |
| — | Item Breakup | for details. | — | ||
| HT/LT Cable laying by horizontal boring below track etc by pushing method-Drilling for horizontal bore below track by pushing method by suitable means for laying of GI pipes/ HDPE pipe etc of various sizes, the bore shall be of 200 mm dia & shall be done at a depth of1200 mm from ground level, it also includes insertion of pipe. | — | — | — | 2,15,700 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of Power cable route indicators with all connected materials and works as per Drawing No.DEE/CN/BZA/2001/23. | — | — | — | 3,900 | |
| — | Item Breakup | for details. | — | ||
| Excavation of cable trench in cement concrete bed flooring by using power drill to a depth of 1.0 Mtr and a width of 0.3mtr. After laying the pipe and refilling the trench with excavated earth and undertaking cement concrete bed flooring to its original shape as was prevailing earlier to the satisfaction of Railways site Engineer and also as per R.B JPO no: No.2003/Tele/RCIL/I Pt.IX dated 24.06.2013.The exact route of the HT/LT cable is to be decided in consultation with Engineer in charge. | — | — | — | 1,43,360 | |
| — | Item Breakup | for details. | — | ||
| Supply, fixing, connecting and commissioning of 6A 3pin/5pin modular plug socket, with 6A modular control switch on existing control board with wiring. | — | — | — | 14,053 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of 10W LED Bulk head fitting with Pressure die cast alluminum with opal diffuser with IP 65 Protection etc., complete. | — | — | — | 67,968 | |
| — | Item Breakup | for details. | — | ||
| Supply and fixing of 20W 4 feet LED tube light with all connected accessories complete for fixing (The supply includes accessories such as clamps, ties extenstion wires etc for fixing) as per attached railway specification | — | — | — | 23,406 | |
| — | Item Breakup | for details. | — | ||
| Supply, Erection and connecting of Cable Junction Boxes IP 65 with metric knockouts for cable entry Cable junction boxes of model no. K 7004 of Hensel make or equivalent make conforming to IS:13573/92,IEC 60947-3 with necessary terminals suitable for cables upto 70Sq mm and all necessary accessories complete. | — | — | — | 88,780 | |
| — | Item Breakup | for details. | — | ||
| Supply, Erection and connecting of Cable Junction Boxes IP 55 / IP 65 with metric knockouts for cable entry Cable junction boxes of model no. K 9255 of Hensel make or equivalent make conforming to IS:13573/92,IEC 60947-3 with necessary terminals suitable for cables upto 25 Sq mm and all necessary accessories complete. | — | — | — | 7,080 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of 50 mm dia GI Pipe 'B' class with threaded at both ends with coupling/flanges completeconfirming to IS: 1239(Part-I)2004. | — | — | — | 43,151.4 | |
| — | Item Breakup | for details. | — | ||
| Excavation of earth for one pit in any soil andrefilling as per Drg.NO. RE/33/P702/ MOD.F | — | — | — | 3,951.96 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of Earth electrode as per the RDSO Drg No. ETI/OHE/P/ 7021 (REV.A) or if any latest. | — | — | — | 20,251.92 | |
| — | Item Breakup | for details. | — | ||
| Drilling of 26 Nos of 12 mm dia holes on Earth electrode. | — | — | — | 1,938 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of Charcoal | — | — | — | 6,037.2 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of Salt | — | — | — | 4,174.8 | |
| — | Item Breakup | for details. | — | ||
| Provision of RCC earth pit hollow box of size300 mm x 300mmx300mm with 50 mm wall thickness as per Drg. no.SDO/RDSO/E&B/001 by using M20 Grade precast RCC. Supply and Erection of RCC precast slabs with hook to cover Earth pits of dimensions as shown in IRSEM drg no 19-D6. All the required materials for this work i.e. stones, cement, iron and sand etc. are to be supplied by contractor. It includes fixing of earth pits at various locations. Inspection by Consignee. | — | — | — | 10,438.32 | |
| — | Item Breakup | for details. | — | ||
| Transportation charges including loading &unloading of earthing arrangements systemmaterial to site / location | — | — | — | 2,982.6 | |
| — | Item Breakup | for details. | — | ||
| Supply erection, testing and comissionin of Maintenance free earthing with all necessary accessories complete according to IS 3043-1987 and as per RDSO spec No: rdso/spec/ps/0109(rev.0)-2008 Amendment'1'. | — | — | — | 1,14,504 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of Copper Strips (25 mm x 3 mm) for Equipment Earthing | — | — | — | 83,520 | |
| — | Item Breakup | for details. | — | ||
| Supply and Installation of 150mm x 50mm x 2mm thick GI perforated cable tray with cover along with required angle supports, with coupler plates, Anchor bolts and nuts etc complete and the tray should be fitted on the wall / Ceiling etc. complete. | — | — | — | 58,880 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Scope of Wiring
ATTACHMENT
JPO Digging of Cable
ATTACHMENT
Technicalspecifications--9-26.pdf
ATTACHMENT
CEGETechnicalCircular_compressed.pdf CEGE Technical Circular
ATTACHMENT
EarthingSpecificationMFEandOther.pdf Earthing Specification
ATTACHMENT
GCC April 22 With Correction Slips
ATTACHMENT
GCC_April-2022WithCorrectionSlips..pdf
ATTACHMENT
RlyBd-JPO-DiggingofCables2013-Re-Circulatedin2022-LATEST.pdf
ATTACHMENT
CEGETechnicalCircular_compressed.pdf
ATTACHMENT
EarthingSpecificationMFEandOther.pdf
ATTACHMENT
GCC_April-2022WithCorrectionSlips._1.pdf
ATTACHMENT
RITESInspectionLr..pdf
ATTACHMENT
ListofLikelySuppliers.pdf
ATTACHMENT
MasterTenderdocumentGTL-EM-10-2026-27.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .