Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹29.9 L+₹15,495 (0.52%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹30.0 L+₹20,649 (0.69%)Rejected-Finance SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | L3 | Rejected-Finance Not lowest bidder |
Tender Value
₹27.8 L
EMD Value
₹55,680
Closing Date
28 Dec 2021, 6:00 pmClosed
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR AND MAINT OF PUMP AND MOTORS, CONNECTED LT PANELS, CLEANING OF UG SUMP, OHR AND CI AND DI PIPE LINES, SLUICE VALVES, VARIOUS SIZES OF RUSTED DISTRIBUTION PIPES GI AND CI AND PVC PIPES (MAP ACCN) AND OTHER CONNECTED WORKS AT RALAWAS UNDER GE BA
2021_MES_483367_2
8821/27/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
BANAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Banar
₹55,680
Yes
22 Jan 2022
7 Dec 2021
30 Dec 2021
7 Dec 2021
28 Dec 2021
14 Dec 2021
Amount
PUMPING Excavation in trenches in any type of soil n.exc 1.5 m wide and depth as required to provide space for repairing of 200 mm bore DI/CI (Class ‘B) pipe line, bailing out water from the pit/trench for repair the pipe line including cutting of existing damaged/leakage portion of pipe line as required length (max 1 Meter) and fixing/jointing of 200 mm bore including new CI /DI pipe line of 200 dia of required length at site with rubber rings, D clamps & detachable joints & nut bolts of suitable size and testing of pipe line to arrest the leakage to entire satisfaction of Engineer-in-Charge and returning, filling in including spreading, levelling, watering & well ramming in layers n.exc 25 cm in each layer. (Note: New pipe line shall be measured and paid seperatly under respective items of Schedule.)
Excavation in trenches in any type of soil n.exc 1.5 m wide and depth as required to provide space for repairing 200 mm bore CI/DI pipe line, bailing out water from the pit/trench for repair the pipe line and checking of lead joint properly, for stoping leakage and testing the pipe line joint to entire satisfaction of Engineer-in-Charge and returning, filling in including spreading, levelling, watering & well ramming in layers n.exc 25 cm in each layer.
All as per item Ser No 2 here-in-before but 150 mm dia
All as per item Ser No 2 here-in-before but 100 mm dia
All as per item Ser No 2 here-in-before but 80 mm dia Note for item No 1 to 5:-(1)The contractor should rectify the defects within 24 hours from the time of information. If contractor failed to rectify the defects within 24 hours, then the recovery will be made against the contractor @ Rs.1000/- per day for delay period (ii) Any type of tools , transportation and petty items required at site will deemed to be inclusive in the of quoted rates for said item.
Supply and fix in repair cast iron sluice valve IS -14846/2000 marked flanged ends with stainless steel rising spindle with CI operating wheel, CI cap with CI gate , brass ring, type PN 1.6 of size 200mm bore including nut, bolts, washers, rubber gaskets all as specified and directed (joints and CI/ DI speciails shall be measured and paid sepratly)
All as per item Ser No 6.00 here-in-before but 150 mm dia
All as per item Ser No 6.00 here-in-before but 100 mm dia
All as per item Ser No 6.00 here-in-before but 80 mm dia
Strip opening of top cover plate (stuffing box) of sluice valves and supply and fix in repair spindle made out of stainless steel and its brass chuck nuts for 150mm dia sluice valves including turning, metling, grinding as per existing size, replace rubber packing sheet and refixing the same position after repair/replacement of spindle alongwith new gland packing & nut bolts, washers complete all as specified and directed by Engr-in-Charge.
All as per item Ser No 10.00 here-in-before but 100 mm dia
All as per item Ser No 10.00 here-in-before but 80 mm dia
Supply & fixing in repair cast iron NRV of 200mm dia Swing Check type G. M. Flap Drilling as per IS:1538 , Body tested to 15 Kg/Sq Cm and Seat tested to 10 Kg/Sq cm both ends flanged and drilled, valve, face rings, and 2 Nos of MS flanges required for fixing of NRV with pipe lines / pipe fitting complete all as specified and directed by Engr-in-Charge.
All as per item Ser No 13.00 here-in-before but 150 mm dia
All as per item Ser No 13.00 here-in-before but 100 mm dia
All as per item Ser No 13.00 here-in-before but 80 mm dia
Supply and fix in repair Air Release Valve of 200 mm bore (Isolating) Cast iron double Air Valve acting (Isolating) Type G&K with Isolating Valve Internals Brass Nut, Natural Rubber Moulded on wooden Balls Drilling as per IS 1538 , Body tested to 15 Kg/CM Sq complete all as specified and directed by Engr-in-Charge.
All as per item Ser No 17.00 here-in-before but 150 mm dia
Excavation in trenches n.exc. 1.5M wide and n.exc. 1.50M in depth for foundation or for taking out/ down rusted water pipe lines etc.not.exc. 10 Sqm on plan and n.exc. 1.50M depth and getting out any type of soil.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm in thickness all as directed by Engineer-in-Charge.
Removing excavated material not exc 50 mtr depositing where directed at a level n exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Material and labour for CI/DI specials such as Bends (any type, radius and angle) tapers any type (straight, bend, increasing, decresing or double socket etc) Tee pieces single branch 'Y' junction, classification, push or flexible rubber gasket joints, up to 200mm bore complete all as specified and directed.
Taking out old/damaged CI/DI/GI Pipe lines upto 200mm dia with accessories from the trench complete all as specified and directed by EIC. Note: Earth work shall be measured and paid seperatly under respective items of schedules.
Supply & ,laying in trenches/under culverts spigot& socketed ductile iron pipe centrifugally cast, Class K-9 of size 150mm bore dia having ISI embossed/ engraved mark confirming to IS-8329/2000 in standerd length of 5.5 to 6.00 mtr suitable for push on rubber tyton joints (gasket D jionting) with cement mortar lining in the pipe all as specified and directed by Engineer-in-Charge (Note: Rubber Joints, CI/DI specials and earthwork shall be measured and paid seprately)
All as per item Ser No 24.00 here-in-before but 200 mm dia
Providing Run lead joint using old retrived lead from item above and making up any deficiency of lead quantity required as specified in SSR & IS specification by procuring new lead incl provision of jointing matrials like a spunyarn, caulking for 200mm bore dia pipe all as specified and directed.
All as per item Ser No 26.00 here-in-before but 150 mm dia
Supply only rubber gasket ring joint suitable for spigot and socket pipes and DI/CI special fittings suitable for 200 mm bore DI pipe line complete all as specified and directed by Engr-in-Charge.
Supply only rubber gasket ring joint suitable for spigot and socket pipes and DI/CI special fittings suitable for 150 mm bore DI pipe line complete all as specified and directed by Engr-in-Charge.
M&L for construction of brick mesonary valve chamber of size 1200 x 1200 x 1000 mm ( Internal dimensions ) with 100 mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate15 mm thick rendering in CM 1:4 to internal walls, floors and upto 150 mm depth below ground level to external walls,including provision of 3 mm thick MS Sheet cover fixed to Ms angle iron frame out of 40 x 40 x 4 mm thick angle iron with necessary MS flat iron stiffeners of size 40 mm x 4 mm including two coat of synthetic enamel painting over one coat of red oxide primer to all steel surfaces and provision of locking arrangement including necessary excavation and earth work in any type of soil all as specified and directed in drawing by Engr-in- Charge. Note:- Dismantling old one is inclusive in the rate quoted for this item.
DISTRIBUTION M & L for PCC type B2 (using 40 mm graded stone aggregate ) of 1:2:4 ratio as in thrust block of pipe line and coping of pipe at bend, pillers at lorry filling points etc. complete all as specified and directed by Eng-in-Charge.
Taking up or down rusted steel tubing and connections from trenches for following sizes upto 40 mm bore of GI tubing in repair/replacement complete all as directed by Engineer-in-Charge.
Taking up or down rusted steel tubing and connections from trenches for following sizes from upto 50 to 100mm bore of tubing for in repair/replacement complete all as directed by Engineer-in-Charge.
Taking up or down rusted steel tubing/PVC pipes and its connections from walls/ PCC and under road for following sizes upto 15/20/25 mm bore of tubing in repair/replacement complete all as directed by Engineer-in-Charge.
Supply & laying, tubes, medium grade, galvanised Iron water tubes of 15 mm dia with screwed socket joint together with and including all GI fittings such as bends, L bows, short piece connections, backnuts, caps plugs, unions etc. fixed to walls with clamps, hooks at suitable interval of height and ceiling or laid in floor complete all as directed by Engineer-in-Charge.
All as per item Ser No 35.00 here-in-before but 20 mm dia
All as per item Ser No 35.00 here-in-before but 25 mm dia
Supply & laying, tubes, medium grade, galvanised iron water tubes with screwed socket joint together with and including all GI fittings such as bends, L bows, short piece connections, backnuts, caps plugs, unions etc., laid in trenches of size 20 mm dia including testing complete all as specified and as directed. Note: -Earthwork shall be measured and paid seperately in relevant schedule of items.
All as per item Ser No 38.00 here-in-before but 25 mm dia
All as per item Ser No 38.00 here-in-before but 40 mm dia
All as per item Ser No 38.00 here-in-before but 50 mm dia
All as per item Ser No 38.00 here-in-before but 80 mm dia
All as per item Ser No 38.00 here-in-before but 100 mm dia
M&L for cutting exsting steel tubing in position for alterations or additions (or lengthening screw on pipe to from connector ) of the off sizes, upto 80 mm dia
M&L for screwing existing steel tubing in position alterations or additions (or lengthening screw on pipe to connector ) of the off sizes, upto 80 mm dia incls fittings
Relaying of old serviceable tubes (existing location to another location) , medium grade, galvanised steel water tubes with screwed socket joint together with and including all GI fittings such as bends, L bows, short piece connections, backnuts, caps plugs, unions etc., laid in trenches/wall/road crossing of size upto 25mm dia including testing complete all as specified and as directed. Note for items Old serviceable tubes shall be reused. (ii) Earthwork shall be measured and paid seperatly.
All as per item Ser No 46.00 here-in-beforebut 40/50 mm dia
Supply and fix in repair stop valves of 40mm bore , cast copper alloy , screwed down , high pressure with crutch or butter fly handle , screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by EIC.
Supply and fix in repair stop valves of 50mm bore , cast copper alloy , screwed down , high pressure with crutch or butter fly handle , screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by EIC.
Supply and fix brass ball valves, high pressure suitable for 20 mm bore pipe , with polythene float and fly nut complete , screwed for iron pipe or brass ferrule complete all as directed by EIC.
All as per item Ser No 50.00 here-in-before but 25 mm dia
Drilling and tapping from ductile iron water mains (in position ) of 150/100 mm bore for branch connection of the internal dia of 20 mm with welded socket clips nuts-bolts in making the arrangementall as directed by Engr-in Charge.
Taking out old foot valve after unscrewing of nut bolts and supply & fix brass foot valve of size 150 mm dia including nut bolts, washers all as directed by Engr-in-Charge.Make:-Normex or its equivalent
All as per item Ser No 53.00 here-in-before but 100 mm dia
All as per item Ser No 53.00 here-in-before but 80 mm dia
M&L for construction of brick mesonary valves chamber of size 900 x 900 x 1000 mm ( Internal dimensions ) with 100 mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate15 mm thick rendering in CM 1:4 to internal walls, floors and upto 150 mm depth below ground level to external walls,including provision of 3 mm thick MS Sheet cover fixed to Ms angle iron frame out of 40 x 40 x 4 mm thick angle iron with necessary MS flat iron stiffeners of size 40 mm x 4 mm including two coat of synthetic enamel painting over one coat of red oxide primer to all steel surfaces and provision of locking arrangement including necessary excavation and earth work in any type of soil all as specified in drawing and directed. Note:- Dismantling of old one is inclusive in the rate quoted for this item
Supply and fix in repair/replacement of mechanical type water level indicator at UG sumps having 2.5 Meter depth including stainless steel multistranded wire ropes, float valves of suitable size and its balancing weight complete all as specified and directed.
Supply and fix in repair/replacement of LED Aviation lights at top of the OHR having 18-21 Meter staging including 3 core multistranded copper wire of suitable size complete all as specified and directed.
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe of 32X6 mm galvanised iron strip complete all as specified and directed by Engr-in-Charge.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 metre deep below ground level) with the top edge of earth plate at a depth not less than 1.5 metre below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm in alternate layers on all sides and including GI earth strip of 32x 6 mm as earth electrode bolted with GI nuts, bolts & check nuts and rivetted to earth (Plate) electrode at one end and connected to Panel at the other, earth strip protected by and incl GI pipe 40 mm dia (medium grade) from top of electrode to Panel and also incl watering pipe GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover with handle, funnel, wire mesh including necessary excavation & earth work, etc as shown on electrical plate No 3 of SSR Part I. Complete all as specified and directed by Engr-in-charge.
PUMPING AND OHR/UG SUMP Testing of portable water from Govt approved Lab sample taken in sterile bottole from UG Sump at main pump & user tap and Water Analysis test report as per IS: 10500 : 2012 to be carried out from Govt college/ Govt approved labs. Note : cost of samplling bottle, transportation and portable water testing charges will be deemed included in the quoted rates by the contractor. Parameters given are as under below : (a) pH value (b) Electrical conductivity (c) Turbidity (d) TDS (e) TSS (f) Hardness (g) Iron (h) Chlorides (j) Fluorides (k) Magnesium (l) Sulphate (m) Nitrate (n) Total alkalinity (o) Residual free chlorine
Supply and fix of water pressure gauge 4" dial 0 to14 kgs/Sqcm of dial needle model round fixed on discharge line of centrifugal pump with control valve all as specified.
M&L for lifting out of horizontal type submersible pump set from the UG sump having 2 meter depth by providing lifting arrangement, transporting the same to & fro workshop for repairs and strip opening of submersible pump set of 72 HP capacity after unscrewing th nuts, bolts, studs, minor connecting items & disconnecting the power cable from its starter for servicing or replacement of defective parts of the motor and pump and lowering in sump the same after repair and making connection complete all as specified and directed by Engr-in-charge. Note:- spare parts of motor and pump will be measured and paid separately under relevent item of this schedule.
Bearing of pump set as per existing make and size
Water seal O ring of the pump set as per exsisting size
Thrust plate including connected items of the pumpset as per existing make and size
Impeller of the pump as per exsisting make and size including connected items
Bush of pump set as per existing make and size
Rewinding of 72 HP horizontal type submersible motor
M&L for serving of soft starters by well conversant soft starter electrician of various capacity and replacement of burnt out /defective parts of soft starters of 15/20/60 HP capacity as per existing make in the existing LT Panel including tightening of control/power cables complete all as specified and directed by Engr-in-Charge.
Replacement of 3 phase contactor of 415V, 50 Amp for 20 HP soft starter
Replacement of 3 phase contactor of 415V, 40 Amp for 15 HP soft starter
Replacement of 3 phase contactor of 415V, 100 Amp for 60 HP soft starter
Replacment of control wiring of 4 core 2.5 sqmm copper multistranded cables
Replacement of contactor coil of 50 Amp 3 phase 415 volt contactor
Replacement of contactor kit of 50 Amp for 3 phase 415V contactor
-do -but 100A Note : Makes of item No (a) ot (g) as per existing make
M&L for servicing of star delta starters by experienced electrician of various capacity and replacement of burnt out /defective parts of starters of 12.5/20/30 HP capacity as per existing make in the existing LT Panel including tightening of control/power cables including suitable lugs/thimble complete all as specified and directed by Engr-in-Charge.
Replacement of 3 phase & neutral contactor of 415V, 40 Amp for 20 HP starter
Replacement of 3 phase & neutral contactor of 415V, 25 Amp for 12.5 HP starter
Replacement of 3 phase & neutral contactor of 415V, 50 Amp for 30 HP starter
Replacment of control wiring of 2.5 sqmm copper multistranded cables
Replacement of contactor coil of 50 Amp 4 phase contactor
Replacement of contactor kit of 50 Amp for 4 phase 415V contactor Note : Makes of item No (a) ot (f) as per existing make
M&L for strip opening / dismantling after disconnecting the power cables & taking out the existing electric motor of 15/20/30/60 HP Centrifugal type from foundation and transporting the same to workshop for repairs and re-fixing the same on existing location and making electric connection including alignment, replacement of coupling bushes, testing and commissioning complete. Note :- Rewinding & bearings will be measured seperately under appropriate item of schedule.
Rewinding of 415 volts, 50Hz 3 phase 2950RPM electric motor with super enamelled copper wire as per specified gauge/ size, suitable for 60 HP Centrifugal motor complete all as specified & directed by EIC. Note:- Contractor will produce guarantee letter for the minimum 6 month of the winding of the motor after satisfactory testing of the motor.
All as per item Ser No 67.00 here-in-before but upto 3 HP motor
All as per item Ser No 67.00 here-in-before but 15 HP motor
All as per item Ser No 67.00 here-in-before but 1450 RPM & 20 HP motor
All as per item Ser No 67.00 here-in-before but 1450 RPM & 30 HP motor
S&F in repair bearing DE/NDE side suitable for 60 HP Centrifugal/monoblock type motor complete all as specified & directed by EIC.
All as per item Ser No 72.00 here-in-before but 3 HP motor
All as per item Ser No 72.00 here-in-before but 15 HP motor
All as per item Ser No 72.00 here-in-before but 20 HP motor
All as per item Ser No 72.00 here-in-before but 30 HP motor
M&L for strip opening of monoblock pump set from foundation after unscrewing the nuts,bolts, & sucion /dilivery pipes of 15 HP capacity and transporting the same to workshop for repair and re-fixing the same with existing electric motor with proper alignment , connection with suction and delivery pipe line including rubber packing or any other petty items required for fixing complete testing and commissioning after satisfactorily repair. Note:- other Items of pump will be measured and paid separately under relevent items of this schedule. (II) Contractor will produce guarantee letter for minimum 6 months of the all items of the pumps after satisfactory testing of the pump.
S&F Bush bearing as per existing size Make:- SKF
S&F Shaft sleeve of bronze/brass as per eixsting size
S&F Impeller of suitable size and make as per existing
S&F water seal with two rubber rings on shaft of rotor
Air lock
S & F ball bearing at DE side of suitable number with gland packing
M&L for painting with two coat of synthetic enamel paint after cleaning & scrubing of fins of motor/pump with sky blue colourand written with letter of size 1cmx1cm in english type of motor/pump, capacity and install date mentioned on motor neat and clean with white colour of letter as per directed by Engr-in-Charge
S & F of PVC fan of 15HP motor & its locking pin/nuts complete.
M&L for strip opening of centrifugal pump set from foundation after unscrewing the nuts,bolts, coupling & sucion /dilivery pipes of 20 HP capacity and transporting the same to workshop for repair and re-fixing the same on existing location & couple with existing electric motor with proper alignment , connection with suction and delivery pipe line including rubber packing or any other petty items required for fixing complete testing and commissioning after satisfactorily repair. Note:- other Items of pump will be measured and paid separately under relevent items of this schedule. (II) Contractor will produce guarantee letter for minimum 6 months of the all items of the pumps after satisfactory testing of the pump.
Remetaling, grinding to pump shaft including balancing, keys, groves etc on leathe machine
S/F shaft SS Keys for Coupling of motor/ pump set shaft
S & F air vent cock of pump set as per existing size
S & F brass/bronze Impeller, with keys
S/F gland sleeves (CI) at DE or NDE side
S & F Impeller seal O ring
S/F bearing housing assembly
S & F water lubricating PVC pipe with both ended nuts of suitable size
S/F coupling of size 5" dia for motor and pump set including rubber groves bushes, nuts, bolts complete
S & F ball bearing at DE & NDE of suitable number with gland packing
S&F coupling guard with nut-bolts
M&L for water seal suitable for 20 HP pump set
M&L for painting with two coat of synthetic enamel paint with sky blue colour.
S & F of PVC fan of 20 HP motor & its locking pin/nuts complete.
M&L for strip opening of centrifugal pump set from foundation after unscrewing the nuts,bolts, coupling & suction /dilivery pipes of 30 HP capacity and transporting the same to workshop for repair and re-fixing the same on existing location & couple with existing electric motor with proper alignment , connection with suction and delivery pipe line including rubber packing or any other petty items required for fixing complete testing and commissioning after satisfactorily repair. Note:- other Items of pump will be measured and paid separately under relevent items of this schedule. (II) Contractor will produce guarantee letter for minimum 6 months of the all items of the pumps after satisfactory testing of the pump.
Remetaling, grinding to pump shaft including balancing, keys, groves etc on leathe machine
S/F shaft SS Keys for Coupling of motor/ pump set shaft
S & F air vent cock of pump set as per existing size
S & F brass/bronze Impeller, with keys
S/F gland sleeves (CI) at DE or NDE side
S & F Impeller seal O ring
S/F bearing housing assembly
S & F water lubricating PVC pipe with both ended nuts of suitable size
S/F coupling of size 5" dia for motor and pump set including rubber groves bushes, nuts, bolts complete
S & F ball bearing at DE & NDE of suitable number with gland packing
S&F coupling guard with nut-bolts
M&L for water seal suitable for 30 HP pump set
M&L for painting with two coat of synthetic enamel paint with sky blue colour.
S & F of PVC fan as exising size of 30 HP motor & its locking pin/nuts complete.
M&L for strip opening of centrifugal pump set from foundation after unscrewing the nuts,bolts, coupling & sucion /dilivery pipes of 30 HP capacity and transporting the same to workshop for repair and re-fixing the same on existing location & couple with existing electric motor with proper alignment , connection with suction and delivery pipe line including rubber packing or any other petty items required for fixing complete testing and commissioning after satisfactorily repair. Note:- other Items of pump will be measured and paid separately under relevent items of this schedule. (II) Contractor will produce guarantee letter for minimum 6 months of the all items of the pumps after satisfactory testing of the pump.
Repairing of main pump shaft made of carbon steel with key by means of remetaling and grinding on leathe machine as standard size.
Main bearing of the pump DE/NDE side of 6313C3/6313C3 or as existing sample.
Shaft sleeve of stainless steel
Impeller of brass/bronze as per existing size
Neck ring.
Air cock with adopter.
Gland dori,Gland plate split type complete with bronze bush, bolts,nuts & washers etc.
MS coupling for shaft of pump and motor complete with rubber bush and nut bolts etc and key.
S & F of PVC fan as exising size of 60 HP motor & its locking pin/nuts complete.
M&L for cement concrete 1:4:8 type D-2 using with 40 mm graded stone aggregate in foundations including dismantling the old foundation all as specified and directed by Engr-in-Charge.
M & L for PCC type B-1 1:2:4 (using 20 mm graded stone aggregate ) as in platform, base etc. complete with quick setting cement complete all as specified and directed by Eng-in-Charge.
M & L for PCC type B-0 in the ratio of 1:2:4 (using 12.5 mm graded stone aggregated ) as in platform, base etc. complete including finishing the surface with quick setting cement including whitewashing and painting with synthetic enamel paint of all metal parts complete all as specified and directed by Eng-in-Charge.
M/L for channels fabricated in the shape of frame as per site requirement and fixing in side the foundation and over the PCC foundation with suitable size and quantity of nuts, bolts and washer complete all as directed by Engr-in-Charge.
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
Supply and fix Butter fly valve of 80 mm dia Make:- Zoloto/Vijay/Upadhyay
M&L for taking out old rusted/unserviceable cable tray of any type and supply and fix Perforated GI Cable tray of 150 mm width and 25 mm depth , having 16 guage complete fixed to Wall or laid in floor to run the cable etc with suitable clamp and spacers for protection of cable complete all as specified and directed.
Cleaning of RCC Semi under ground water storage tank of 25000 gallons cap of 2.5 Meter deep from top located at pump house having two compartments including taking out the dead storage water by means of pumping or by manually and bailing out of mud if any and applying two coats of white wash internally all internal walls & portition walls and writing down the date of cleaning, cap of under ground storage tank with white synthetic enamel paint of 40mm size over the back ground of black paint at the place as shown all as specified and as directed by Engr-in-charge.
All as per item Ser No 88.00 here-in-before but 50000 gallons capacity at hill top.
Cleaning of RCC OHT water storage tank having 18/21 meter staging of 50000 gallons cap located at MAP Accn area & main pump house area having two compartments including bailing out the dead storage water by means of pumping or by manually and taking out of mud/sludge/soil and applyng with two coats of white wash to all internal walls & portition walls and writing down the date of cleaning, cap of under ground storage tank with white synthetic enamel paint of 40mm size over the back ground of black paint at the place as shown all as specified and as directed by EIC.
Cleaning of RCC Semi under ground water storage tank of 1.0 LG capacity located at main pump house area having two compartments including taking out the dead storage water by means of pumping or by manually and taking out of mud if any and applying with two coats of white wash to all internal walls & portition walls and writing down the date of cleaning, cap of under ground storage tank with white synthetic enamel paint of 40mm size over the back ground of black paint at the place as shown all as specified and as directed by EIC.
All as per item Ser No 91.00 here-in-before but 1. 5 LG capacity at Banar.
Material & labour for taking out old PCC vent pipe of any size and fixing of 150mmdia PCC/RCC vent pipe at roof of semi UG sump of 1.5-2.0 feet long including drilling in roof of sump of suitable dia mortar complete all as specified and directed.
Painting of iron angle, MS sheet, grills, pipe lines with suitable colour after scrubing & cleaning of old rusted surface by spray painting system/machine making rasing and distribution line indication arrow mark with black paint and writting letter not exc 30 cm height of letter on motor capacity ,installation date etc complete all as directed by Engineer - in -Charge
Cutting of PCC floor for trench/drain or making holes in the building walls for passing of cables/earth strips & drain pipe as required on site basis and making good surface with cement mortar complete all as directed by Engineer - in -Charge
M&L for stone masionary squared rubble walling jodhpur type brought uptocoursewell bonded bedded and soliding hearted built will cement mortor 1:4 as per pecpcified as dirtected by Engr-in-Charge
M&L for rendered 10mm thick plaster wall/surface for two coat as per specified as dirtected
M&L for white washing on fresh plaster wall/surface for two coat as per specified as dirtected
Supply only D Climp/Flat clamp and plug for arresting/breaking of unauthorised tapping complete all as specified and dirtected by EIC
Supply only ARV PVC ball as per existing size suitable for eisiting size of air release valve complete all as specified and dirtectedbt EIC
Servicing of motor under minor maintance of 15/20/30 HP motor gressing check leakage nut bolt tighting checking lose electrical connection etc complete as per specified as dirtected by EIC
Disconnect water and electric connections submersible pump/motor, lifting from bore hole, dismantling submersible pump upto 5 HP capacity, carrying out minor repair/maintenance work, replacement of unserviceable nut, bolt, washer etc including necessary cutting, grinding, drilling, machinery/lathe work for fixing of spares and re-assembling the same, returning back after repair, reinstalling /lowering in original position, reconnecting water and electric connection, water proof insulation tape of length 3 Mtr, width 20mm for jointing the submersible cables and testing, provision of SWG wire suitable gauge for holding the motor with tie outside complete all as specified and as directed by Engr-in-Charge.
Anil Builders
INDO CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .