Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 CrAccepted-AOC | ₹20.0 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹21.1 CrRejected-Finance 102 SUBHASH ROAD HERITAGE HEIGHTS DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹21.1 Cr | L2 | Rejected-Finance DUE TO RATE EXCESS FROM L1 |
Tender Value
₹20.1 Cr
EMD Value
₹40.1 L
Closing Date
26 Sept 2024, 5:00 pmClosed
SANJAY RAJ
Office of Superintending Engineer Irrigation Works Circle UTTARKASHI
Construction of 50 Bedded Critical Care Block Under of (ECRP-II) in Distt-Uttarkashi
2024_IRDCE_75042_1
03/SE/2024-25
Open Tender
Civil Works - Buildings
540 days
BHATWARI
AS PER STANDARD BIDDING DOCUMENT
4 documents required · 4 mandatory
₹5,900
Executive Engineer Infrastructure Division
₹40.1 L
DEHRADUN
11 Nov 2024
29 Aug 2024
27 Sept 2024
29 Aug 2024
26 Sept 2024
4 Sept 2024
3 Sept 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Centering and shuttering including strutting, propping etc. and removal of form work for :
Foundations, footings, bases for columns
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand(zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
1:5:10 (1 cement : 5 coarse sand(zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (Zone III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources).
Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth.
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Edges of slabs and breaks in floors and walls .Under 20 cm wide
Weather shade, Chajjas, corbels etc., including edges
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuou agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately)
All works upto plinth level
All works above plinth level upto floor V level
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite stone slab colour black, Cherry/Ruby red /Area of slab over 0.50 sqm
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium pull bolt lock, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws bolts, nut and washers etc. complete.
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
1.5 mm thick.
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120gm/sqm) duly filled with vermiculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge(Dash fastener to be paid for separately).
Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators & partitions etc., with G.I. beading made out 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance of 75 mm from the edges and 150 mm c/c, including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading & special ceramic tape of 5 x 20 mm size etc. complete in all respect as per NBC 2016, IS 16231 (Part 3) :2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 min of insulation (EI20).
The manufacturer has to give test report / certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100 x 2200 mm (w x h) or 2.42 sqm.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: profile C
Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
25 mm thick.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for pre finished nosing to treads of steps of marble stone
Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre.
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Size of Tile 800x800 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design
In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all eights, as per specifications, drawings and as directed by Engineer-in-Charge
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection >0.70 and initial emittance >0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
New work (two or more coats) over and including water thinnable priming coat with cement primer.
Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion .Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Upto 5mm depth and 5 mm width
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Excavation in Cutting in Soil by manual means with lead upto 50 mExcavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading II Materia
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. (By Mechanical Means with 1 km lead)
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed wit bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 507 complete in all respects.)
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 507 complete in all respects.)for Grading I ( 40 mm nominal size
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion pressure distributor at the rate of 0.30 to 0.35 kg per sqm on the prepared non-bituminous surface cement concrete pavement) cleaned with Hydraulic broom as per Technical Specification Clause 503.
Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702
12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand)
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer?in-charge.
Providing and Fixing chlorinated Polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15mm dia nominal bore
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall
25mm dia nominal bore
32mm dia nominal bore
40mm dia nominal bore
50mm dia nominal bore
65mm dia nominal bore
80mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
32 mm nominal bore
65 mm nominal bore
Providing and fixing in position of approved quality high pressure rated Gun Metal Float Valve with copper ball float and brass rods of required length suitable for test pressure of not less than 15 Kg/sqcm of the following sizes: 25 mm dia
Providing & fixing Auto Air vent for cold water supply risers, suitable for pressure not less than 15Kg/Sq.cm. 25 mm dia
Providing and Fixing chlorinated Polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15mm dia nominal bore
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
50mm dia nominal bore
65mm dia nominal bore
80mm dia nominal bore
Providing and fixing nitrle rubber insulation on hot water supply / return pipes.
80 mm dia (19 mm thickness of Insulation)
65 mm dia (19 mm thickness of Insulation)
50 mm dia (13 mm thickness of Insulation)
32 mm dia (13 mm thickness of Insulation)
25 mm dia (9 mm thickness of Insulation)
20 mm dia (9 mm thickness of Insulation)
15 mm dia (9 mm thickness of Insulation)
Providing and fixing brass stop cock of approved quality : 15 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
20 mm nominal bore
32 mm nominal bore
65 mm nominal bore
80 mm nominal bore
Providing and fixing soil, waste and vent pipes : 100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
75 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing plain bend of required degree.100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
75 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing double equal plain junction of required degree. 100X100X100X100 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
75X75X75X75 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing single equal plain junction of required degree :100X100X100
Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
75X75X75 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 100 mm dia
SS 304 grade coupling with EPDM rubber gasket
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 75mm dia
SS 304 grade coupling with EPDM rubber gasket
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
100 mm inlet and 100 mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing in position G.I. pipe and fittings of class `C' (heavy class) conforming to IS:1239 for waste pipe from individual fixtures to floor trap / floor drain & vent pipe Including fixing at wall / ceiling level supported by galvanized clamps and hangers providing two coats of synthetic enamel paint of approved shade as per pipe colour code over a coat of primer or cutting & chasing in wall & floors, providing protection to embedded GI pipes & fittings by wrapping of polythene sheet (400 microns) over two coats of bitumen including proper overlaps in joints complete as required and making good the chase by using 1:1 cement mortar.
65mm dia
40mm dia
Providing and fixing G.I. Inlet fitting with maximum 3 inlets 32,40 & 50 mm size fabricated from 100 mm dia G.I.pipes and welded G.I. sockets as per site locations, fixed to C.I. Trap and set in cement concrete as per drawing complete as per approval of the engineer-in-charge.
Providing and Fixing Floor drain by fixing G.I. Reducing elbow of 100 x 50 mm in cement concrete 1:2:4 at all levels (exlcuding cost of grating) for connection to floor traps complete as per required slope as per drawings and as per approval of the engineer-in-charge.
Providing and fixing heavy duty S.S. Floor grating with frame of approved design including setting in floor with cement motor to match with floor finish as per architect requirement.
Size 150 mm x 150 mm or 125 mm dia
Size 100 mm x 100 mm or 100 mm dia
Providing and fixing cast brass FCO/COP with suitable insert keys for opening, male threaded joint with G.I socket sockted to pipe as directed by the project manager complete in all respects.
For 150 mm dia pipe
For 100 mm dia pipe
Providing, fixing, testing and commissioning of Hubless centrifugally cast iron pipe & fitting conforming to IS : 15905 joints clamps/ structural steel supports as required/directed at site including cutting & making good the walls, floors, R.C.C. work etc, cutting chases & filling the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or cement mortar 1:4 (1 cement : 4 coarse sand) as required, including earth work in excavation and back filling in layers of 200mm with watering and hammering for compaction complete in all respects.150 mm dia
Providing, fixing, jointing, testing and commissioning uPVC (Class-2), 4Kg/cm2, Rain water down take pipe conforming to IS:4985 cut to required lengths including all necessary fittings and specials,fixing at wall/ceiling level supported by galvanized steel clamps & hangers, making proper connection with cement solvent joint as per BIS / manufacturer. Cutting, chases / holes in floors / walls / slab. 160 mm diameter
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. White Agaria Marble Stone
Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings : Size 450x300x150 mm
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colourweighing not less than 88 gms.
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
Providing and Fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality colour and make, weighing not less that 105gms
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineerin- charge.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
15 mm nominal bore
Providing and Fixing C.P. brass twin coat hook with PVC rawl plug & C.P. brass screw complete as required.
Providing and Fixing adjustable type wash basin for handicap toilet complete with brackets, tracks, waste pipes and other accessories complete as required.
Providing andFixing 2 Nos. support arms and backrest to mounted on the track (vertically and laterally) for handicap toilet complete as required.
Providing and Fixing raised toilet seat with cover for handicap toilet
Providing and Fixing 35 mm dia powder coated steel grab bar.
Providing and Fixing, testing and commissioning of C.P. brass wall / counter mounted sink mixer with C.P. wall flange, overhead swinging spout complete as required and making good.
Providing and Fixing fully automatic "NO TOUCH" hand drier suitable to operate on 220 volts, single phase 50 Hz, A.C power supply and directly plugged to power point complete.
FIRE HYDRANTS & SPRINKLER SYSTEM Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
150 mm dia
100 mm dia
80mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 150 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Gunmetal
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel,ISI marked, conforming to IS 5290 (type A) with blank gunmetal/Stainless Steel cap and chain as required :
Single headed Gunmetal
Providing & fixing flow switch in following sizes M.S.pipe including connection etc as required.150 mm dia
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m
Providing & fixing angle iron (40 mm x 40 mm x 5mm) door frame and MS sheet (2mm thick) cum glass shutter of size 2.1 mtr. X 1.2 mtr. (N.S.) with 25 mm x 25 mm x 3 mm angle fram all around & stiffened in between i/c hinges, handle, locking arrangement, painting with approved synthetic enamel paint i/c sign writing on grass at internal hydrant including providing & fixing M.S.Sheet 2 mm thick on remaining portion above door to close opening i/c painting etc. as required.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun Metal
Providing and fixing standard fire man's axe (Tested for 20000 volts) with heavily insulated rubber handle (ISI marked)
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Upright Sprinkler
Pendent Sprinkler
Horizontal side wall sprinkler
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following sizes complete as required.
Providing, installation, testing & commissioning of water curtain nozzle 15mm dia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required.
Supplying, installation, testing & commissioning of deluge valve (to be used for water curtains) UL listed with wet pilot basic trim assembly for DVA with test and alarm, drip and drain valve with water motor gong complete as required.100 mm dia
Providing & fixing dial type pressure gauge (dial diameter 100 mm, caliberation 0-15 kg/sqcm) with ball valve and pipe at hydrant station.
Providing, fixing and installation of 25mm dia gunmetal inspecting & testing assembly with ball valve, gunmetal sight glass, bye pass valve & connected to drain line complete in all respects. (Flow switch shall be set to activate between 30 to 60 second upon opening of the test valve.)
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm 2 complete as required.
Providing and fixing MS cabinet (size 600 x 450 x 150 mm) fabricated from 16 gauge MS sheet with full front glass door & locking arrangement with suitable shelves for keeping 60 Nos. spare sprinklers & one no. spanner properly fixed in shelves. Cabinet shall be painted with enamel paint of approved shade. (Cost shall include 25 Nos. (Pendent 15 Nos, upright 5 & extended through Side wall 5 Nos) spare sprinklers & one No. spanner).
Providing and fixing gunmetal single acting air release valve for each risers with screwed inlet with ball valve as per IS : 12992 rated for 16 Kg/cm2 pressure rating. (25 mm dia)
Providing and fixing in position approved make fire bucket of 24 gauge, galvanized steel, standard 9 liters capacity and of round bottom shape, panted white inside and red outside and black on bottom dome with letters ‘FIRE’ in black and gold with all mounting bracket and screws.
Providing and fixing of fire Bucket Stand including sheet metal (16 gauge) shade for 4 buckets. Platform and associated civil works complete.
Providing and fixing of ISI marked Portable Fire Extinguisher, CO2 type of 4.5 Kg capacity flat base conforming to IS: 15683 : 2006 including valve, discharge hose of not less than 10mm dia. 1m long and complete in all respect including initial fill with CO2 gas conforming to IS: 307-1966 filled to a filling ratio of not more than 0.667 and wall suspension bracket.
Providing and fixing of 6 Kg capacity Dry Chemical Powder, Portable Fire Extinguisher, dry powder type (Gas Cartridge) conforming to IS: 15683 : 2006 with cylinder initially fully charged with dry powder, ISI marked confirming to IS:15683 : 2006 complete with standard discharge valve with tube, CI bracket for wall mounting.
Providing and fixing of ISI marked portable fire extinguisher Mech. Foam type capacity 9 liters conforming to IS: 15683 : 2006 with gunmetal cap and nozzle and complete in all respects including initial fill and wall suspension.
Providing & fixing ISI marked portable fire extinguisher, water Carbon dioxide (CO2) type of 9 liters capacity conforming to IS : 15683 : 2006 with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets.
Providing & fixing of weather proof hose cabinets fabricated from 16 g M.S. sheet with full glass door and locking arrangement, suitable to accommodate 2 nos.15m long 63mm dia hose, 1 branch pipe, 1 No fire man's axe."Fire Hose" written on front including suitably mounted on a raised masonry platform as required. (Approx.size 0.75 m x 0.6m x 0.25m). Cabinet shall be provided with angle at the edges to reinforced the cabinet.
SUB HEAD-1: WIRING & SUBMAIN Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100 mmX75 mm)
4 Module (125 mmX75 mm)
6 Module (200 mmX75 mm)
8 Module (125 mmX125 mm)
12 Module (200 mmX150 mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with Flameproof Switches modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps Flameproof s modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).(IP-65)
Supplying and fixing suitable size GI box with Flameproof Switches modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps Flameproof s modular socket outlet and 15/16 amps modular switch, connection etc. as required.(IP-65)
Supplying and fixing suitable size GI box with Weatherproof Boxs modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps Weatherproof s modular socket outlet and 25/32 amps DP MCB, connection etc. as required.(IP-65)
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
SUB HEAD -II : DISTRIBUTION BOARD Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator).All distribution board should be with the space provision for ELCB.
8 way , Double door
12 way , Double door
16 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4+12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Double pole
Triple pole
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I. bolts & nuts, etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
SUB HEAD- III : CABLE TRAY Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supply, Unloading, Receiving, Storing, Assembling, Fixing, Testing and Commissioning of the following lighting fixtures with all fitting, driver, housing & reflector complete with providing of all necessary hardware’s like raw plugs, hangers, support plates and connection wire in flexible GI pipe from point to light terminal as required for fixing etc. as required. Complete in all respect. All toll & tackles required for successful installation, testing & commissioning shall be in scope of installer. Philips,Wipro, Tishva
LED1X4Ft Panel or equivalent
20W Wall Batten or equivalent
18W Recessed LED Downlighter or equivalent
LED 2X2 Panel. (36 Watt). or equivalent
LED Bulkhead. or equivalent
18W Downlighter or equivalent
Mirror Light .or equivalent
Supply, Unloading, Receiving, Storing, Assembling, Fixing, Testing and Commissioning of Single sided exit sign board for wall / ceiling / pendant cantilever mounting, with white housing, Red stencil & Battery backup capability and dual power supply (AC/DC) and push to test switch for mandated code compliance testing, including long life SMF rechargeable Ni Cd battery and internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 90 minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. Complete in all respect.
Same as above but two sided sign board.
Note:- Sign Board to comply with UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes and UL listed for damp locations. (0°C – 50°C)Supply Unloading, Receiving, Storing, Assembling, Fixing, Testing and Commissioning of the following Ceiling & Exhaust Fan, ready to installation condition complete in all respect.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safetyrope, copper winding, PowerFactor not less than 0.9, ServiceValue (CMM/W) minimum 6.85,Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remoteor electronic regulator unit for speed control and all remainingaccessories including safety pin,nut bolts, washers, temperaturerise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
300 MM dia Exhaust fan of approved make 240 Volt, 50 Hz including all accessories, wiring for connection, clamp, hardware consumables etc complete with all accessories.
SUB HEAD - V : UPS WORK Supply,Installation,Testing & Commissioning of micro processor controlled True On line double conversion, Stand Alone mode 3 Phase input and 3 phase 415V output UPS & each UPS consisting of followings :
1 No. 100% Rectifier + Inverter, Integrated in UPS module Battery Circuit breaker Galvanic Isolation transformer at the inverter output of UPS Module Inbuilt Static switch for bypass and inverter in UPS module Manual Maintenace bypass Sealed Maintenance free batteries for 30 minutes backup time with UPS & inerconnectors, Rack and accessories and UPS to battery DC cable upto 10 meters.
100 kVA(1 Working (for Equipment ,OTS ).
1 x30 kVA(for Emergency Lighting,Work Stations, Fire Alarm, Server and CCTV ).
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
SUB HEAD - VI: SERVER, DATA & VOICE NETWORKING Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet
TV antenna socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 1 run of cable
Supplying & Fixing of Non- PCB based Information Outlet (I/O) RJ45, Tolless Termination TIA-568C Category-6, Termination of Catergory-6 UTP Cable, UL listed ,Shall conform to Category-6 as per the EIA/TIA-568C.2,Shall support network line speeds up to 1 Gbps, Shall have RJ-45 type connector with bend limiting and strain relief boot for securing IDC contacts from external forces and for maintaining the bend radius of the cable, Shall have minimum duraility of 950 or Above mating cycles and 200 termination cycles. Certified by independent labs like ETL/GHMT/3P for compliance to EIA/TIA-568C.2 complete in all respect.
Supplying & Fixing of Single Faceplate Shall be Single Port (RJ45) square plate, dimension as per commercially available modular office furniture.Shall have spring shuttered front access for preventing ingress of dust,Shall be supplied with Gang Box of the same size by System Integrator complete in all respect.
Supplying & Fixing of Single Faceplate Shall be Duplex Port (RJ45) square plate, dimension as per commercially available modular office furniture.Shall have spring shuttered front access for preventing ingress of dust,Shall be supplied with Gang Box of the same size by System Integrator complete in all respect.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
2 run of cable
3 run of cable
Supplying & Fixing of Category 6, UTP patch cords shall be constructed of 24-27 AWG unshielded twisted pair stranded copper cable with an enhanced performance modular plug at each end. Patch cord cable shall be offered in multiple colored UTP cable for design flexibility with a clear strain relief boot on each modular plug. All patch cords shall be compatible with both T568A and T568B wiring schemes. UTP Cable will be 1.0 mtr. complete in all respect. Jacket - LSZH .
Supplying & Fixing of Category 6 UTP patch cords shall be constructed of 24-27 AWG unshielded twisted pair stranded copper cable with an enhanced performance modular plug at each end. Patch cord cable shall be offered in multiple colored UTP cable for design flexibility with a clear strain relief boot on each modular plug. All patch cords shall be compatible with both T568A and T568B wiring schemes. Blue UTP Cable, 2 Meter complete in all respect. Jacket -LSZH .
Supplying, of 50 Pair armoured Jelly filled copper conductor armoured Cable with suitable clamps, saddles and including making terminal joints complete as required.
Supplying, Installation, Testing & Commissioning of of 50 Port telephone Jack Panel Approved. .
Supplying Installation testing and Commissioning of 12 port 10/100/1000BASE-T POE ports and four GbE/10GbE SFP/SFP+ uplink ports, layer 3 from day1 having static & RIP ,stackable upto 10 switches, should support external redundant power supply, certified , each switch should be provided with stacking port/cable complete in all respect
Supplying Installation testing and Commissioning of 24 port 10/100/1000BASE-T ports and four GbE/10GbE SFP/SFP+ uplink ports, layer 3 from day1 having static & RIP ,stackable upto 10 switches, should support external redundant power supply, certified , each switch should be provided with stacking port/cable complete in all respect
Supplying & Fixing of Rack -Wall Mount - 15U - 600W - 500D - Double Fan Provision - Black Fine Tex, Metal Cable Manager - 01U - Plastic Cable Loop's Mountable - Pastal Fine Tex. - Assembly, Power Distribution Unit - 06/13 Amp Multi-Standard - 06 Socket - Single Pole / Screw Mountable / 06 Amp MCB / Alternating Current - 06 Amp 3 Pin Plug with Power Cable 0.75 sq.mm 3 meter Length - Black Fine Tex. - Assembly complete in all respect.
Sub-Head -VII : Close Circuit Television and Security System /CAMERA AND ACCESSORIES/CCTV (Video Surveillance) Supply, installation, testing and commissioning of following cameras including all accessories as per specification.
Supplying, installation, testing and commissioning of 2 megapixels resolution Network Dome Camera for true HD quality images,2.8 – 12 mm varifocal lens,True Day/Night (TDN) functionality for true color image ,Motion Detection 4 Zones, Multi- Level Sensitivity Privacy Zones 4 Zones,Snapshoot Support JPEG format Password Protection Support Character Display Support(Channel /Date) ONVIF Yes,IR Illumination20-30M IR illuminators for clear images in low light conditions Wide Dynamic Range 3D noise reduction for sharper images and lower bandwidth use in low light ONVIF compliant complete in all respect.
Supply, installation, testing and commissioning of 2 megapixels resolution Network Bullet camera camera,Imager 1/2.8”SONY 2.43 mega low illumination CMOS,Video Compression. .H.264/MJPEG,Day/Night .Mechanical ICR,Minimum Illumination-0Lux/F1.4(IR ON) IR Illumination-40-50M,,Electronic Shutter-Auto/Manual(1/25~1/10000) Lens 2.8 – 12 mm varifocal lens,Resolution Main-stream:D1/Q1080P(960*540)/HD720P/ HD1080P 1-25/30fps,Digital Noise Reduction-3D,Wide Dynamic Range-Digital WDR Motion Detection -4 Zones, Multi- Level Sensitivity,Privacy Zones-4 Zones,Snapshoot-Support JPEG format,Password Protection-Support,Character Display-Support(Channel /Date).Regulatory Emissions-FCC Part 15 CE: EN55022,Immunity -CE: EN50130-4,IP Rating- IP66 rated enclosure to protect against dust and water damage ONVIF compliant .
Supplying of 4U Rack mount single chassis Network Video Recorder with dual Gb NIC, 1 DVI-I + HDMI + 1 Display Port, max 2 simultaneous monitors, RS-232/485 serial port, DVD, Server Operating System- Windows 10,Ubuntu Linux 16.04, Gen 4 Intel Core i7, Local Client Display Rate (FPS)Windows – 700 FPS (HD)Linux – 900 FPS (HD),High Performance, High Reliability IP Recorder. — Continuously records 400Mbps (Windows) & 800 Mbps (Linux)of video while hosting a local client, multiple remote clients and the web server on a single server,RAM-8 GB, 16 GB (Optional)solid-state operating system drive,USB-6 x USB 2.0, 2 x USB 3.0 high air flow cooling and hardware monitoring features ensure maximum uptime. keyboard and mouse, Professional Grade client and server software pre-installed and software updates. Access live and recorded video on multiple client PCs with free Windows, Mac or Linux client application. web server application is pre-installed on the server to access video through a web browser or free Mobile iPhone / iPad and Android apps. Maximum Storage Capacity 240TB RAID6 & Maximum Hard Drive 20 Slot(Up to 12TB) Support Up to 32 IP Camera.
Supply, installation, testing and commissioning of Enterprise Class 6TB HDD.
Supply, installation, testing & commissioning of 12 Port PoE+ Switch with 2 SFP slots 12 x 10/100/1000 Base-T PoE+ ports and additional 2 100/1000X SFP PORTS Should support PoE+ as per IEEE 802.3 at with PoE budget of 100W.Should support STP, RSTP, MSTP, IGMP v1/v2/v3 snooping, STP root guard, Voice VLAN, MLD snooping (MLDv1 and v2), IEEE 802.3ac VLAN tagging IEEE 802.17/equivalent for sub 50ms ring protection in following scenario : single, dual fibre cuts in ring and when fibre cut at common shared link in between two or more rings.
Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); Memory: 4GB, NON-ECC, 1600MHZ; RAM: 4GB (1x4GB) Non-ECC DDR3 1600MHz SDRAM Memory; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; 20" TFT Monitor; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit.
Supplying, Installation,Testing & Commissioning of 55 " LED Full HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 5000:1,Built-in Speaker (10W + 10W), Magic Clone (to USB), Auto Source Switching & Recovery, Lamp Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play (DDC2B), Pivot Display, Clock Battery, PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock, HDCP Support, Smart Scheduling, Smart F/W update, Built-In MagicInfo Premium-Swith Mounting Brackets as per Technical Specification complete in all respect.
Sub-Head - VIII- DISTRIBUTION BOARDS/FRONT OPERATED PANEL Design, manufacture, supplying fixing in position of the following front operated cubicle type,compartmentalised with front access, dead back, 2mm thick steel enclosed free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system, and suitable for a fault level of 25 KA symmetrical at 415 volts.All switchboards shall be modular type and have provision for entry of cables from the top /bottom as required. The cost shall include providing and fixing of 100 x 50 x 6 mm channels for switchboard support.All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. All MCCB shall have phase barriers, rotary handles and extension terminal as required . All unbalanced kWH meter shall have communication module for BMS connectivity MDB-1 ( Ground Floor , First ,& Second )
INCOMER 1 No.200 amps 4P MCCB (25 KA) with thermal Magnetic release (PRMB-3) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.METERING & INDICATION/1 set of R,Y,B phase indicating lamps/1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB/1 No. (0-200A) Ammeter with ASS with 3 nos.200/5A CT's/1 No. Digital Electronic KWH meter(Dual Source).BUS-BAR 1 Set of 250A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 4 Nos. 63A TPN MCB (10 KA) / 4 No. 40A TPN MCB (10 KA)
MDB-1 ( Ground Floor) as described above
MDB- U1 ( MEDICAL EQUIPMENTS INPUT PANEL)
INCOMER
1 Nos. 160 amps 4P MCCB (25 KA) with thermal Magnetic release (PRMB-3) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B phase indicating lamps
1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
1 No. (0-160A) Ammeter with ASS with 3 nos. 160/5A CT's
1 No. Digital Electronic KWH meter(Dual Source).BUS-BAR 1 Set of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 1 Nos. 63A 4P MCCB (25 KA) 2 Nos. 100A 4P MCCB (25 KA)
MDB- U1 ( MEDICAL EQUIPMENTS INPUT PANEL) as described above
MDB- U1.1 (MEDICAL EQUIPMENT PANEL NON-UPS-1)
INCOMER 1 Nos. 160 amps 4P MCCB (25 KA) with thermal Magnetic release (PRMB-3) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.METERING & INDICATION for each Incomer 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-160A) Ammeter with ASS with 3 nos. 160/5A CT's 1 No. Digital Electronic KWH meter(Dual Source).BUS-BAR 1 Set of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS 3 Nos. 100A 4P MCCB (10KA) 3 Nos. 40A 4P MCB (10KA)
MDB- U1.1 (MEDICAL EQUIPMENT PANEL NON-UPS-1) FOR MEDICAL EQUIPMENT as described above
MDB- U1.3 (MAIN UPS IN PUT PANEL FOR MEDICAL EQUIPMENT
INCOMER 1 Nos. 630 amps 4P MCCB (25 KA) with thermal Magnetic release (PRMB-3) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.METERING & INDICATION for each Incomer 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-630A) Ammeter with ASS with 3 nos. 630/5A CT's 1 No. Digital Electronic KWH meter(Dual Source). 1 Set of 800A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
1 Nos. 63A 4P MCCB (25 KA)
6 Nos. 100A 4P MCCB (25 KA)
MDB- U1.1 (MAIN UPS INPUT PANEL) FOR MEDICAL EQUIPMENT as described above
MDB- (Lift)
INCOMER 1 No. 100 amps 4P MCCB(16 KA) with thermal Magnetic release (PRMB-3) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION for each Incomer 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB ,1 No. (0-100A) Ammeter with ASS with 3 nos. 100/5A CT's 1 No. Digital Electronic KWH meter(Dual Source). BUS-BAR/1 Set of 300A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS 3 Nos. 100A 4P MCCB (10KA) 3 Nos. 40A 4P MCB (10KA) 3 Nos. 40A DP MCB (10 KA)
MDB- G (Lift) as described above
HVAC Panel
INCOMER 1No. 400A FP MCCB (25 KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION 1 set of R,Y,B phase indicating lamps / 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB,1 No. (0-400A) Ammeter with ASS with 3 nos. 400/5A CT's,BUS-BAR 1 Set of 400A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
4 Nos. 63A FP MCCB (16 KA)
3 Nos. 40A FP MCB (10 KA)
4 Nos. 16A FP MCB (10 KA)
SDB- HVAC Panel as described above
FK 1230 Suppression System & its Equipments 120 Litre Seamless Cylinder CCOE Approved, complete with valve assembly and a pressure gauge with a safety burst disc and a safety cap.
FK 5-1-12 agent ( FK 1230 GAS )
Electric Cum Manual Actuator.
Pneumatic Actuator.
Discharge Nozzles are designed to provide the proper flow rate and distribution of FK 5-1-12 to total flood a hazard area : 180 deg. / 360 deg.
Master Cylinder Adapter Kit
Flexible discharge Hose
Manifold Check Valve installed at the discharge manifold to allow removal of any FK 5-1-12 cylinder from the manifold while still retaining a closed system.
Flexible Actuation Hose
Manifold Discharge Pressure Switch
M.S. Container strap ( 120 Ltrs )
Warning Sign Board.
Sub-Head - IX- LIFT Elevator in lift shaft of dimensions 2400mm x3000mm (W x D) 20 passenger/1420 Kg. MRL lift with variable voltage variable frequency drive having a speed of 1.6 metre/ sec and travel height of 13 m(approx.) with 3 Stops, 900mm Door Width, 2100 mm Height and Microprocessor based control suitable for operation on 415 V, 50 Hz, 3 phase A.C. electric supply as required and as per specifications.
Sub-Head - X : NURSE CALL SYSTEM Supply,Installation Testing and Commissioning of Microprocessor controller Nurses station with terminal monitor with in built power supply , with charger enclosed in a powder coated cabinet . Having with Reset, alarm/ buzzer, Call acknowledge with battery back up, battery charger complete system as per technical specifications and as per required of following suitable configuration. complte as required.
Supply Installation Testing & Commissioning of Bed Call Push Button with LED indication and Flexiable Cord with button , Call Reset , Call Indication, station for each Bed complete as required.
Supply Installation Testing & Commissioning of LED Indicators Module at Outside of each ward complete as required.
Two Loop Panel
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.s.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Public Address System Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required..
Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required
Supply, Installation, testing and commissioning of DVD Player, complete required as per specifications.
Supply Installation testing and comisioning of 19-inch Equipment Rack with standardized frame or enclosure for mounting multiple PA controllers, CD player, Amplifiers etc modules. Size 24U.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying, Installation,Testing & Commissioning of 40 " LED Full HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 5000:1,Built-in Speaker (10W + 10W) complete in all respects.
Supplying, Installation,Testing & Commissioning of Teller Station Unit Software ,Zero Foot Print Installation allows counter staff to Call, Forward, Re-direct Customers,Advanced Option includes Pause & resumption of Services with Real time.
Supply, installation, testing & commissioning of Workstation as per following specifications: Processor Intel Core i5,RAM 8GB, HDD 500GB at each doctors cabin for Teller software
Supplying, Installation,Testing & Commissioning of Branch Admin(Per Department) with Pending Patient,Current Serving Patient,Served Patient,Active Patient,Pending Patient,Sending Messages to Patient.
Supply, installation, testing & commissioning of Workstation as per following specifications: Processor Intel Core i7 or better,Chipest Intel orginal motherboard ,RAM 16GB,3.5”SATA HDD 1TB or higher ,Video card Dedicated 2GB RAM or better Output Ports: HDMI/Display Port/DVI & 22" Display at control room equivalent.
Supply & Fixing of HDMI Cable,VGA Cable, Data Cable,Speaker Cable above system OEM Approved
Supply, installation, testing & commissioning of two 11Mtr. pole structure, 11KV with cross arms, suitable clamps, insulators, disc insulators, 11KV lightning arrestors, complete stay with insulator & wire, foundations, gang operated air break switch with extended handle, 11KV drop out fuses. This shall have termination arrangement for outgoing through HT (UE) cable of suitable size and necessary 6 inches dia GI pipe shall be provided for cable support complete in every way.
11 kV HT 'H' pole as per specification & as described above
Supply, delivery, erection, testing and commissioning of a Single panel board , Outdoor duty totally enclosed sheet steel clad floor mounting, vermin proof, fully interlocked vertical isolation, extensible, horizontal draw out, air insulated, metal clad switchboard having double isolation features complete with circuits as detailed below. The switchboard would be complete with necessary PVC insulated copper busbars, small wiring, labels, cable eyes, cable termination to receive XLPE cables, foundation bolts and suitable for operation on 11 kV 3 phase, 50 cycle, earthed system with a rupturing capacity of 350 MVA.Incoming cum outgoing feeder shall have fault trip auxiliary contacts for wiring to annunciation fault trip indication panel.11 KV HT Switchboard -outdoor duty-(IP-55) near meter boardVCB panel require with following items.Incomer Cum outgoing -1- Air insulated metal clad housing/1- set of 3 phase PVC insulated copper busbars 630 amps /6- Single pole cluster type isolating contacts; i.e. plug and switches/1- Triple pole drawout truck mounted 11 kV 500 MVA, 630 amps Vacuum circuit breaker fitted with arc control devices.
1- Trip free 230 V AC, motor charged spring release closing mechanism complete with necessary auxiliary switches emergency hand trip device and mechanical 'OFF' and 'ON' indicator.6 NO/NC contacts for remote ON/OFF/TRIP status 1 - 24 volts DC shunt trip coil 3 - Dual Core Cast resin Current transformers of ratio 200/5 Class 5P10 and Class 1.0, 15 VA burden for protection & metering. 1- Strip heater with thermostat to prevent absorption of moisture/1- 3 Phase cast resin horizontal draw out line potential transformer ratio 11000/√3 :110/√3 volts, connected star/star with H.V. and L.V. connections, H.V. and L.V. fuses, isolating plugs for H.V. and L.V. connection.
1- Amber indicating lamp for auto trip
1- clear indicating lamp for trip circuit healthy
1- set of white indicating lamps one per phase
1 - blue indicating lamp for spring charged
incoming & outgoing - cable termination suitable for Raychem make cable joint to receive 11 KV (UE) XLPE cable 3 core 300 sqmm
The switchboard shall be complete with all interconnections, label wiring, etc as required and as per direction
11 KV Single panel VCB Switchboard as described above
Supply, delivery, erection, testing and commissioning of Panel board , indoor duty totally enclosed sheet steel clad floor mounting, vermin proof, fully interlocked vertical isolation, extensible, horizontal draw out, air insulated, metal clad switchboard having double isolation features complete with circuits as detailed below. The switchboard would be complete with necessary PVC insulated copper busbars, small wiring, labels, cable eyes, cable termination to receive XLPE cables, foundation bolts and suitable for operation on 11 kV 3 phase, 50 cycle, earthed system with a rupturing capacity of 350 MVA.All Incoming and outgoing feeders shall have fault trip auxiliary contacts for wiring to annunciation fault trip indication panel.11 KV HT Switchboard -Indoor duty-(IP-52)/Incomer Cum outgoing Incomer 1- Air insulated metal clad housing 1- set of 3 phase PVC insulated copper busbars 630 amps /6- Single pole cluster type isolating contacts; i.e. plug and switches/1- Triple pole drawout truck mounted 11 kV 350 MVA, 630 amps Vacuum circuit breaker fitted with arc control devices.
1- Trip free 230 V AC, motor charged spring release closing mechanism complete with necessary auxiliary switches emergency hand trip device and mechanical 'OFF' and 'ON' indicator.6 NO/NC contacts for remote ON/OFF/TRIP status 1 - 24 volts DC shunt trip coil/3 - Dual Core Cast resin Current transformers of ratio 75/5 Class 5P10 and Class 1.0, 15 VA burden for protection & metering.1- Strip heater with thermostat to prevent absorption of moisture.1- 3 Phase cast resin horizontal draw out line potential transformer ratio 11000/√3 :110/√3 volts, connected star/star with H.V. and L.V. connections, H.V. and L.V. fuses, isolating plugs for H.V. and L.V. connection.
1- set Electro mechanical auxiliary relay for transformer fault ALARM for winding temperature conditions (63x)/1 - no. circuit breaker control switch for electrical (T/N/C)1 - push button on front door for emergency trip/1- set of Red/Green indicating lamps for close and open position.1- Amber indicating lamp for auto trip /1- clear indicating lamp for trip circuit healthy/1- set of white indicating lamps one per phase /1 - blue indicating lamp for spring charged.1- cable termination suitable for Raychem make cable joint to receive 11 KV (UE) cable 3 core 300 sqmm.The switchboard shall be complete with all interconnections, label wiring, etc as required and as per directionOutgoing feeder consist with the following
1- Air insulated metal clad housing,1- set of 3 phase PVC insulated copper busbars 630 amps 6- Single pole cluster type isolating contacts; i.e. plug and switches.1- Triple pole drawout truck mounted 11 kV 500 MVA, 630 amps Vacuum circuit breaker fitted with arc control devices.1- Trip free 230 V AC, motor charged spring release closing mechanism complete with necessary auxiliary switches emergency hand trip device and mechanical 'OFF' and 'ON' indicator.6 NO/NC contacts for remote ON/OFF/TRIP status .1 - 24 volts DC shunt trip coil.3 - Dual Core Cast resin Current transformers of ratio 75/5 Class 5P10 and Class 1.0, 15 VA burden for protection & metering.1- Strip heater with thermostat to prevent absorption of moisture.The instrument and relay panel fitted with
1- set of Red/Green indicating lamps for close and open position.1- Amber indicating lamp for auto trip .1- clear indicating lamp for trip circuit healthy.1- set of white indicating lamps one per phase 1 - blue indicating lamp for spring charged.1- cable termination suitable for Raychem make cable joint to receive 11 KV (UE) cable 3 core 300 sqmm .The switchboard shall be complete with all interconnections, label wiring, etc as required and as per direction
11 KV Single panel VCB Switchboard as described above
Supply, erection, testing and commissioning of 230V, single phase 2 wire AC to 24V DC Batteries charger with semiconductor/IGBT fullwave rectifier with auto /manual float cum boost facility complete with 24V DC, 120 AH sealed maintenance free batteries including one no. distribution board having 63 Amps DP MCCB as incomer and 12 Nos. 20/16A DP MCB's (D.C. duty) as outgoing complete as required and as per technical specifications.
Supply, installation, testing and commissioning of 800 kVA, 11000/433 volts Deta/Star, vector group DYN11, outdoor mounting, oil cooled, ONAN transformer having AVS relay and RTCC for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote manual operation of OLTC, suitable for incoming voltage variation of +5% to –15% in 16 steps to give a constant secondary voltage. The transformer shall be provided with fittings, accessories, protection, first filing of oil etc. including Buchholz oil temperature alarm/trip protection in LV chamber complete as per specifications and as required. The transformer shall be provided with arrangement to terminate XLPE cable on HT side and to connect Aluminium Bus Duct on LT side, complete as required. The losses of the Transformer should be as per latest ECBC guideline.As per Latest IS:1180 & Transformer efficiency type -2.
HT CABLE END TERMINATION Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core (UE), XLPE aluminium conductor cable of 11 KV grade as required. 300 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core (UE), XLPE aluminium conductor cable of 11 KV grade as required. 300 sq. mm
Supplying of following sizes of XLPE aluminium conductor, corss linked polythylene, individual core screwed, flat steel strip armoured, PVC sheathed cable of 11KV grade (earthed) comforming to IS: 7098 (Part 2),with uptodate ammendment complete as required.
3 C x 300 Sq.mm XLPE HT cable (U.Earthed)
Sub-Head - III- LT PANELS & DISTRIBUTION BOARDS The contractor shall consider the following details in their item rates, wherever required:
Supporting rigid steel framework.Cubicle type, 14 gauge CRCA sheet steel enclouser.Complete with interconnections and distribution bus bars.Proper bonding to earth.Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram.Providing cable clamps / supports within distribution boards cable alley.TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link.All MCB’s shall be of minimum 10 KA breaking capacity.All motor feeders MCCBs shall be of motor duty.Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5.Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.IP 42 for indoor panels.IP 54 for kitchen and laundry panels.
IP 55 for outdoor panels,All MCCB’s shall be provided with operating mechanism for door interlock.Current density of aluminium shall be 1 sq mm for 1.0 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1.25 amps for rated current of bus bars.Tinned copper earth bus shall be provided through out the length of each board.All measuring instruments (Meters) shall be of digital electronic with LED of approved make and compatible with BAS.All hinged door shall be earthed through 4.0 sq mm tinned braided copper wire.
All panels shall have provision of the following: Pad locking of Switch board doors.Pad locking of MCCB’s handles in “OFF” Position.Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various transducers in Main Switch Board sections. Only transducers shall be supplied by BAS contractor.All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation.All PTs / control transformer shall be provided with centre tap earth secondary.All DOL & Star-Delta Starters shall be provided with SPPR (single phase preventor relay) and 2 nos. of Aux.Contacts for Remote operation/monitor.The Panel fabricator shall provide Al./ Copper Bus-bars link from Breakers wherever more than two nos. of cables are terminated in the breakers.Readymade 16 SWG Sheet steel Enclosure with cutout For MCBs.The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise.Protection Releases Microprocessor based (PRMB) & Thermal magnetic (PRTM) shall be as described below .
Protection Release Microprocessor Based (PRMB-1) Over-current/long time protection range 40% - 100 % with Time setting short circuit /short time protection range 100% - 1000 % with Time setting.Instantaneous short circuit Protection range 150% - 1200 % with Time setting,Earth Fault Protection range 20% - 100 % with Time setting/Under voltage & over voltage protection
Protection Release Microprocessor Based (PRMB-2) Over-current/long time protection range 40% - 100 % with Time setting Over-current/long time protection range 40% - 100 % with Time setting short circuit /short time protection range 100% - 1000 % with Time setting/Instantaneous short circuit Protection range 150% - 1200 % with Time setting/Earth Fault Protection range 20% - 100 % with Time setting
Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 25 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below.
MAIN LT PANEL, Panel’s shall be provided AS PER IEC-61439 Capacitor Panel’s shall be provided AS PER IEC-61921 MAIN LT Panel WITH AMF AND APFC INCOMER FROM TRANSFORMER From 1000 KVA Transformer
1 No. 1600A 4 pole microprocessor based EDO, ACB (50kA) with integral protection as per PRMB-1 mentioned in Premable 1 set of 1600/5A, 15 VA, class-1 CTs for APFC relay 1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs.1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-1600A) Ammeter with ASS with 3 nos.1600/5A CT's 1No. Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh) etc 1Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps.240 V AC Motor wound spring closing mechanism1 - 24 volts DC shunt trip coil 6 nos NO/NC contacts for remote opening & closing Terminals to receive XLPE insulated Aluminium cables Class – B transient voltage surge suppression devices suitable for 3 phases as per specification.
INCOMER - 2 NUMBERS 1 Nos. 1000A 4 pole microprocessor based EDO, ACB (50kA) with integral protection as per PRMB-1 mentioned in Premable with reverse power relay.1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-1000A) Ammeter with ASS with 3 nos. 1000/5A CT's 1No. Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh) etc ,1 Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps.
Hardware using PLCs for Monitoring of all Electrical Software and for operations, controlling and interlocking Parameters of 1 Nos. DG Synchronosation Panel & 1 Nos. Transformer with Window based software & Engineering & Software Development. Required Aux. Relays, Push Buttons & Indication lamps, 1KVA UPS for Black start & maintenance free Batteries, Power monitors, Programmable Logic controller,.(As per SLD).The Switchboard with Logic control panel shall be complete with all interconnections, risers, internal wiring, labels, control/circuit fuses etc. complete as required. Note: Incomer from LT Supply, DG Synchronosation Panel & Bus coupler shall be electrically & mechanically interlocked.
Main LT Panel as described above
Capacitor Panel (200 kVAR), INCOMER 1 Nos. 400A TPN MCCB (36 KA) as per PRMB-2 as mentioned in Preamble
1 No. 12 step-Microprocessor APFC controller/Relay(Dual source purpose) shall continuously monitoring all three phases and LCD displays for various Electrical Parameters like voltage, input current, capacitive current, KVA demand, KW, Power Factor, self diagnostic error code indication with printout facility of the above with RS 232/RS 485 port. Controller should mounted on the front side of the panel. Capacitor bank having 3 phase MPP based mix dieelectric low loss ISI marked power capacitor and provided with Electronic Thirstier based switching to suppress switching of inrush current and reducing harmonics capacitor life. 1 Set. R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs.BUS-BAR/1 Set of 500A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS 3 Nos.of 80A TP MCCB (25 KA) each with 3 Nos. 25 KVAR capacitor Bank each with 7% harmonic & discharge resistor with thyristor module suitable capacity to carry expected current continuosly.3 Nos.of 63A TP MCCB (25 KA) each with /3 Nos. 15 KVAR capacitor Bank each with 7% harmonic & discharge resistor with thyristor module suitable capacity to carry expected current continuosly.8 Nos.of 40A TP MCCB (25 KA) each with
8 Nos. 10 KVAR capacitor Bank each with 7% harmonic & discharge resistor with thyristor module suitable capacity to carry expected current continuosly.
Capacitor Panel-1 (200 kVAR) as described above
MAIN LT Panel Building
1 Nos. 1250A 4 pole microprocessor based EDO, ACB (50kA) with integral protection as per PRMB-1 mentioned in Premable with reverse power relay.1 set of 1250/5A, 15 VA, class-1 CTs for APFC relay.1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs.1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB.1 No. (0-1250A) Ammeter with ASS with 3 nos.1250/5A CT's. 1No. Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh) etc .1Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps.240 V AC Motor wound spring closing mechanism.1 - 24 volts DC shunt trip coil.6 nos NO/NC contacts for remote opening & closing/Terminals to receive XLPE insulated Aluminium cables.Class – B transient voltage surge suppression devices suitable for 3 phases as per specification.
INCOMER FROM DG SIDE 1 Nos. 400A 4 pole microprocessor MCCB (50kA) with integral protection as per PRMB-1 mentioned in Premable with reverse power relay.1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs.1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-400A) Ammeter with ASS with 3 nos. 400/5A CT's 1No. Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh) etc .1 Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps.
BUS BARS 1 Nos Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 1600 amps having a maximum current density of 0.8 amp per sq mm suitable to with stand symmetrical fault level of 50 kA at 415 volts. The neutral busbar is to be of 50% capacity.
BUS COUPLER-1:- 1 No. 630A 4 pole microprocessor based MDO, MCCB (50kA) , .1 Set of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required.
OUTGOINGS-Bus Section-1 5 Nos. 250A TPN MCCB (36 KA) .with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. & Multifunction meter with 485 port & 3 nos.250/5A CT's .2 Nos 400A TPN MCCB (36 KA) .with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. & Multifunction meter with 485 port & 3 nos.400/5A CT's .2 Nos. 630A TPN MCCB (36 KA) .with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. & Multifunction meter with 485 port & 3 nos.200/5A CT's .3 Nos.160A TPN MCCB (36 KA) .with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. & Multifunction meter with 485 port & 3 nos.160/5A CT's .
4 Nos. 250A TPN MCCB (36 KA) .with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. & Multifunction meter with 485 port & 3 nos.200/5A CT's .3 Nos. 100A TPN MCCB (36 KA) .with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. & Multifunction meter with 485 port & 3 nos.100/5A CT's .2 Nos. 63A TPN MCCB (36 KA) .with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. & Multifunction meter with 485 port & 3 nos.63/5A CT's .
Main LT Panel as described above
Supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based Novec 1230 System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System), consisting of the Mentioned components
4 Kg capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube, 4Kg Novec 1230 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.
Linear pneumatic heat Detection Tube with all necessary fittings & supports.
Master Control Unit for controlling each system, complete with pressure switches, buzzers and electronic hooters, including all necessary accessories + electrical wiring to make each entire system functional.
Bus Duct (In sandwich Construction) Supply, laying, testing and commissioning of 1.1 kv grade XLPE insulated PVC sheathed alluminium armoured stranded conductor ISI marked LT Cables in trenches/ ducts/ through RCC pipes under roads/ on cable trays of following sizes, complete all as specified (as per CPWD specifications for External Electrical works), i/c clamping, dressing, earth work digging, sand filling, bricks protection, back filling etc. as required & approved by Engineer's Incharge. (Tagging to be provided with aluminium strips on both the ends as approved).
3½ core X 300 Sq.mm.
3½ core X 240 Sq.mm.
3½ core X 185 Sq.mm.
3½ core X 50 Sq.mm.
3½ core X 35 Sq.mm.
4 core X 16 Sq.mm
Supplying and making cable end termination with brass compression glands and aluminium lugs including inhibiting compound to be used in each lug, for the following XLPE aluminium conductor armoured cables of 1.1 KV grade etc, complete as required.
3½ core X 300 Sq.mm.
3½ core X 240 Sq.mm.
3½ core X 185 Sq.mm.
3½ core X 50 Sq.mm.
4 core X 16 Sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
900 mm width X 62.5 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
450 mm width X 62.5 mm depth X 2.0 mm thickness
300 mm width X 62.5 mm depth X 2.0 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
100 mm width X 50 mm depth X 1.6 mm thickness
Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Sub-Head - VII - External Lighting
Feeder Piller-1 ( Ext.Light ) Typical For Feeder Piller- 2
Design, Fabrication, Supply, Erection, Testing and commisioning of Powder coated, Weather Proof Double door type Feeder pillar fabricated out of 14 guage CRCA sheet steel in cubical, free standing, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Feeder pillar shall be treated with all anti-corrosive process before painting as per specification. Feeder Pillar shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels. Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated ) INCOMER 1No. 40A FP MCCB(16 KA)
Metering & Indication 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-40A) Ammeter with ASS with 3 nos. 40/5A CT's BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS 1 no 32 A TPN RCBO 30mA,10 kA with thermal magnetic releases each with Dual setting 24 hour calibrated time switch with automatic adjustments for seasonal variations based on site settable latitude for automatic operation of the supply, 32 amp TP Contactor for operation of the outgoing supply through the Time Switch and with 10 nos 10/20 amp SPN 10 kA MCB's as outgoing.
Feeder Piller-1 ( Ext.Light ) as described above
EXTERNAL LIGHTING WORK
The rates for fixing of lighting fixtures shall include all fixing accessories that may be required to make the installation complete in all respects .
Internal wiring between accessories connecting wires wherever required.
Earthing of fixtures .
70W LED Street LIGHT Supply,of LED LAMP , made with pressure die cast aluminium housing, of wattage 60 W ,PC diffuser WALL type size . Luminaire shall be complete with encapsulated isolated integral driver and capable of operating at line voltage without any separate power supply from 140 to 270 VAC,50Hz,powerfactor>0.95.CRI>70,THD<10%, Inbuilt surge protection of >2.5 KV & external SPD of 10KvCCT-3000k, Fixture shall be suitable to operate at ambient temperature range of-10°Cto+50°C and shall be IP65 . Lifetime should beat least L70:50000 burning hours at 50°C.Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. Similar to Tisva Cat no. LANDSCAPE STREET LED LSL706US 70W 65K , IP65
Supply of 30W LED street Light with integral control gear comprising heavy duty copper ballast , PF improvement capacitor, connection & wiring from junction box with 3# 2.5 sqmm copper wires, Mounted on existing Pole.
Supply of 80W LED floolight luminaire for building highlighter.
Supply of 6W LED Bollard Light.
Supply of 30W LED Post Top luminarie with powder coated PDC aluminium body with opal diffuser
Supply, installation, Testing & commissioning of steel tubular swaged poles with bent on top along with reaquired accesseries to accomodate street light fitting complete with cast iron base plate, finial taper plug, bolts, nuts, junction box within the pole for incoming and outgoing cables (size up to 2 C x 6 Sqmm) and a 10 amps SP MCB and screws as specified in type 410 SP31 - 7.5 mtr. Long. Rate shall included the cost of inbuilt junction box (weather proof), MCB to fitting with 2.5 sq mm copper wires (2 Nos. 2.5 Sq.mm copper wire for phase & 1 No. 1.5 Sq.mm copper wire for earthing) complete with base plate made from concrete civil foundation works . The pole shall be painted with final PU Paint as required.
Supply, Installation & Commissioning of Solar PV stand alone Street Lighting System comprising of two 37 Wp / one 74 Wp SPV module, one 12 V, 75 Ah Tubular Plate sealed maintenance free VRLA Gel Battery, one luminaries with inbuilt inverter, dusk to dawn circuit for automatic switching on & off at dusk & dawn and 24 W LED Light, pole, one charge-regulator, module mounting structure, Pole mounted Battery box, cables and other fittings along with 5 (five) years guarantee / warranty period (25 years for SPV Module).
Supplying and drawing following sizes of PVC insulated PVC sheathed copper conductor unarmoured multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable copper lugs connections etc. as reqd.
3 core 1.5 sq.mm.
Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable in existing trenches/ hume pipe/in ground as per IS : 7098:1988 with upto date amendments.
4c x 16 sq.mm
4c x 10 sq.mm
3c x 6 sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 core X 16 Sq.mm
4 core X 10 Sq.mm
3 X 6 sq. mm (19mm)
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply and fixing in position 1000mm wide checkered rubber matting of 11KV grade as per electricity rules,with thickness not less than 12mm.
Supply and fixing in position the best quality L.T. Danger Notice plate of 200mm x 150mm,made of mild steel atleast 2mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side written in English & Hindi as required.
Supply and fixing in position the best quality H.T. Danger Notice plate of 250mm x 200mm made of mild steel atleast 2mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side written in English & Hindi as required.
Supply and fixing in position the approved shock treatment / restoration charts written in Hindi and English duly framed in teak wood frame and covered with 2.8mm glass as required.
Supplying and fixing of fire buckets 5 Nos.in each set of approved quality, red painted from outside and white from inside conforming to IS : 2546/1974 with additional handle at the bottom, filled with fine sand and fixed on an angle iron frame as per the requirement of local authorities.
Supplying and fixing of MS pedestal stand suitable for supporting four buckets as required.
Supplying and fixing First Aid Box of 18 S.W.G. M.S sheet,painted as approved & prescribed by Indian Red Cross Society & as per attached specifications.
Supply and fixing in position the approved single line diagram framed in 1000 x 800 mm size glass framed and installed in main switch room.
Supply of tool kit with 1 pair,11KV rubber hand gloves of aproved make.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
100 mm dia pipe
150 mm dia pipe
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
100 mm dia ID
150 mm dia ID
300 mm dia pipe
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required
90 mm dia (OD-90 mm & ID-76 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
Rates should include lifting shifting to installing level of machines and indoor units should include Y-joints, headers and cordless remote controls for operation of indoor units,2 Core shielded communication wire in conduit between outdoor to indoor unit.Commissiong of VRV/VRF system shall also include top up gas charges and shall not be paid later as additional item.Ducted type Indoor units should be provided with fire retardant double flexible connection between fan outlet & ducts.All the ODUs to be kept on Structural Platform with Vibration Isolators to avoid the transfer of Vibrations directly on Slab. All indoor & outdoor units shall be quoted with Hydrophyilic coating for protection from corrosive element in the surroundings.
Exposed copper pipe of the ODU should be coated with 2 coats of chemical resistant coating (AC gaurd CP or equivalent)to protect against corrosion & erosion . Coil fins should be coated with solvent based Fine polymer coating (coil shield Plus or equivalent)VRV/VRF systems should be BMS and fire alarm compatible .HVAC contractor should provide the units with provision of auto sequencing for equal run time.
VRV/VRF units with Scroll Compressor Capable of Modulating Capacity,i.e. it should be able to vary speed of the compressor as per the varying load conditions and works on R410A/R407A with Heating/ Cooling both.The outdoor unit should be Factory assembled unit Housed in a sturdy weather proof casing constructed from rust proof mild screen panels powder coated finish.The outdoor units must have multiple scroll Compressors for 14HP and above modules.The Outdoor unit must have Refrigerant cooled Inverter PCB to ensure smooth operation in high Temperatures. Outdoor Unit must having COP of 5.0 or more at 50% Load and 35 deg outside ambient Conditions.All the units shall be provided with buil in microprocessor control panel for automatic operation and capacity control. All compressor shall have inverter based technology.The manufacturer of compressor and ODU shall be same.VRV/VRF TYPE UNITS: (Tailor made units shall be procured from other vendors duly approved by the manufacturer of the VRV units)VRV Cooling and heating mode type
Outdoor units shall have cooling & heating mode, consisting of one/multiple modules with digital vapour injection/inverter scroll technology based compressor and environment friendly refrigerant R-410A/R407A. The unit should have COP as per ASHRAE 90.1 (Latest standard) . The C.O.P confirmation should be from the O.E.M letter, for the following capacities.The cost shall include the cost of Cabling from MCB/ELCB/isolator to the outdoor unit. (Cable Length to be as per drawing).Isolator cost shall also include.The unit shall be provided with its own microprocessor control panel with provision for integration with the building management system for Air-conditioning system.The units shall be suitable for 415V±10%,50 Hz. supply & complete with electrical controls & panels. Cost of Cowl with Birdscreen (If Required) for Top Discharge outdoor unit shall also include ,requirement of cowl to be verified by the HVAC Vendor as per drawing /site conditions &cost of MS stand for ODUs should also considered. External vibration pad shall also be provided during installation. Below Outdoor units are Top Discharge,However HVAC Vendor is suggeted to verify their performance. Anti-Corrosive treatment on the complete refrigerant piping and on the Outdoor units fins should be provided.
OUTDOOR UNITS VRV/VRF TYPE: ODU (For All areas)
Outdoor unit complete with scroll compressor, condenser & its controller as described below of following actual capacities.These outdoor units are dedicated for the treated fresh air units.
ODU (for Corridor TFA)
Supply,installation,testingandcommissioningoffollowingminimumcapacityVRV/VRFHighwalltypeIndoorunitequippedwithwashablesyntheticmediapre-filter,fansectionwithlownoisefan/dynamicallybalancedblower,multispeedmotor,coilsectionwithDXcoppercoil,electronicexpansionvalve, outercabinet,cordlessremotecontrol,drainpan,necessaryaccessoriesetc.,suitableforoperationon230V±10%,50Hz,singlephaseACsupply,completeasrequired. TheunitshallhaveautomaticforceshutdownprovisionincaseoffireonreceivingsignalfromBMSSystem.Thecoolingcapacityofindoorunitwillbeatairinletconditionsof27Degree C DB and 19 Degree C WB temperature. - Hi WallType
Ground Floor - Hi WallType
2-Bed Maternity ward
Back office billing section
Change room01
Change room02
Doctors lounge
Double height entrance lobby
Dr.Duty room 01
Dr.Duty room 02
Emergency X-Ray
Isolation room
Manifold room
Minor OT
New born critical
Nurse duty room
One point care lab
Change room01
Change room02
Plaster room
Police post
Triage green zone
Triage red yellow zone
Triage screening
Waiting area
First Floor - Hi WallType
2bed dailysis room
6 Bed isolation ward 01
6 Bed isolation ward 02
6 Bed isolation ward 03
6 Bed isolation ward 04
7 Bed HDU including 2 padriatics
Councilling Room
Dr.Duty Room01
Dr.Duty Room02
Isolation Room01
Isolation Room02
Nurse Duty Room
Paramedical staff room
Support of Dialysis
Waiting Area
Change Room 01
Change Room 02
Change Room 03
Change Room 04
Change Room 05
Change Room 06
Second Floor - Hi WallType
Councilling Room 01
Councilling Room 02
Criytical Equipment consumable incharge
Report Writing
Dauffing Room
Donning Room
Doctors Lounge
Nurses Lounge
Waiting Area
10 Bed ICU
Change 01
Change 02
Change 03
Change 04
Change 05
Change 06
Change 07
Dr.Duty Room
Post OP Pre OP
Supply,installation,testingandcommissioningoffollowingminimumcapacity4-wayflowVRV/VRFCassetteTypeIndoorceilingmountedunitequippedwithsyntheticwashablemediapre-filter,fansectionwithlownoisefan/dynamicallybalancedblower,multispeedmotor,coilsectionwithDXCoppercoil,electronicexpansionvalve,outercabinet,drainpump,grill,necessarysupports,vibrationisolation,cordlessremotecontroletc.,suitableforoperationonsinglephase230V±10%,50HzACsupply,complete,asrequired.TheunitshallhaveautomaticforceshutdownprovisionincaseoffireonreceivingsignalfromBMSSystem.Thecoolingcapacityofindoorunitwillbeatairinletconditionsof27DegreeCDBand19DegreeCWB temperature.
Ground Floor - CassetteeType Lift Lobby
First Floor - CassetteelType Lift Lobby
SecondFloor - CassetteelType Lift Lobby
SecondFloor - CassetteelType Dormitory
Ceiling Mounted Ductable Type: Supply, installation, Testing & Commissioning of Ceiling Mounted Duct Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections complete with blower section with blower suitable for static pressure as required, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.4mm) cooling coil of 6 row deep (3RD + 3RD), filter section with 50mm thick metal viscous/ washable synthetic type air prefilters efficiency 90% down to 10 micron (MERV 8) & Fine filter (Bag filters) efficiency 99% down to 3 micron (MERV 13), belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply, drain connections, stainless steel (18G) drain pan with insulation, necessary vibration isolation arrangement etc. complete as required of following capacities The units shall be suitable for 230V±6%, 50 Hz. supply & complete with electrical controls & panels.
For (CorridorTFA)
AHU, Controls, Expansion Kit, Communication PCB & Thermostat ,Supply, installation, testing and commissioning of Electronic Type Expansion Kit, Communication PCB with Sensors, Corded Self Diagnostic Type Digital Thermostat, Y-joints etc. as required.
For VRV/VRF DX OT 01 AHU Of Capacity 2600 CFM, 6.0 TR
For VRV/VRF DX OT 02 AHU Of Capacity 3700 CFM, 7 TR
FITTINGS & CONTROLLERS : SITC of Wired Remote Controller for Indoor Units with suitable wiring (1.0sqmm x 2C) in PVC conduit
SITC of Centralized remote controller suitable for operation & monitoring of indoor units (44 nos.units). Controller shall be capable of scheduling and BMS compatible.
SITC of fittings ;Refnet/Y joints to connect the various indoor units to outdoor unit.
41.3 mm O.D - 19 mm thick insulation
34.9 mm O.D - 19 mm thick insulation
28.6 mm O.D - 19 mm thick insulation
22.2 mm O.D - 13 mm thick insulation
19.1 mm O.D - 13 mm thick insulation
15.9 mm O.D - 13 mm thick insulation
12.7 mm O.D - 13 mm thick insulation
9.5 mm O.D - 13 mm thick insulation
6.4 mm O.D - 13 mm thick insulation
Providing & fixing control cum transmission wiring of 2 core x 1.5 sqmm copper in suitable 25 mm dia heavy duty PVC conduits or wall chase between indoor units and outdoor units and indoor units and wired remote controllers.
Providing and Fixing UPVC6kg/cm² pipes of various sizes with 6mm nitrile insulation for condensed water drainage from indoor unit to nearest disposal point in Toilet/Outside rain water harvesting system as per specification
25 mm dia pipe
32 mm dia pipe
40 mm dia pipe
(15mm static pressure) forMale Female Toilets
300 mm dia 900 RPM fan suitable for 220±6% volts 50 cycles, 1 phase AC supply.
Supply, fabrication, Installation, testing and commissioning of factory fabricated rectangular/round/elliptical ducts using G.I Sheets (120GSM coating). The price shall include factory fabricated TDF flanges, turning vanes, splitter dampers, supports (factory fabricated, full threaded GI rod/hangers & G.I slotted channel), sealant, neoprene gasket, access door etc. The joints shall be with least leak and shall be tested with pressure testing machine.
24 gauge galvanized sheet steel ( TDF 01- 750mm)
22 gauge galvanized sheet steel ( TDF 751 - 1500mm)
20 gauge galvanized sheet steel ( TDF 1501- 2250mm)
Supply, installation, testing and balancing of opposed multiblade box type GI volume control damper within ducts to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system as per approved shop drawings & specifications.(All AHUs, fan sections VCD at machine outlets shall be included in the equipment cost only)
Supply, installation, testing & balancing of removable core type , linear, fixed bar extruded aluminium powder coated Supply Air / Return Air / Exhaust Air grills, normal flow, 15° angle one way / two way deflection with all sides flanges.Blade thickness shall be minimum 5mm in front and 1.0 mm in rear side.Grills shall be supplied in accordance with specifications and approved shop drawings.
200 mm/150mm/100mm High
Supply, installation, testing & balancing of removable core type , linear, fixed bar extruded aluminium powder coated Supply Air / Return Air / Exhaust Air grills, normal flow, 15° angle one way / two way deflection with all sides flanges.Blade thickness shall be minimum 5mm in front and 1.0 mm in rear side.Grills shall be supplied in accordance with specifications and approved shop drawings.
200 mm/150mm/100mm High
Supply, installation, testing & balancing of key operated extruded Aluminium volume control dampers in black mat finish for supply/return/exhaust air duct collars as per approved shop drawings and specifications.
Supply, installation, testing & balancing of Fresh air Extruded Aluminium intake louvers with bird screen and opposed blade box type GI volume control damper complete as per specification & approved shop drawings.Construction/profile of the louvers shall give a protection against the rain and suitable for fixing in the external facade of the building.
Supply, installation, testing & balancing of Exhaust air Extruded Aluminium intake louvers with bird screen complete as per specification & approved shop drawings.Construction/profile of the louvers shall give a protection against the rain and suitable for fixing in the external facade of the building.
Supply, installation, testing & balancing of factory made Bird screen made out of galvanized steel mesh in 20G having diamond pattern with GSS flanges and necessary cross bracings suitable for Fresh/ Exhaust air fans on terrace, complete as per specification & approved shop drawings.
Thermal Insulation(Internal ducting): Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
13mm thick (Supply air Ducts )
19mm thick (TFA Ducts)
Supply & Installation of acoustic lining within supply and return air ducting using open cell elastomeric insulation Class I with with 140-160 Kg/cum. density.All ducts shown cross hatched on the approved shop drawings shall be provided with acoustic lining as per the specifications.The cost shall be inclusive of low VOC adhesive.
15 mm thick
25 mm thick
Supply, installation, testing & commissioning of 630 KVA continuous rating (Prime power), 415 V, 3 phase, 4 wire, 50 Hz at 0.8 P.F, 1500 RPM, radiator cooled, silent diesel generating set along with complete fuel piping with accessories, anti vibration mounts, base frame, required hardware, Batteries, Engine control panel with accessories, residential silencer, flexible connection, bellow/expansion joints etc. with all associated equipment/work as per specifications to make the DG set installation complete in all respects as per site requirement. Engine & Alternator to be designed for 40 degree ambient temperature and the Alternator shall be with H class insulation. Silencer shall be with 75mm thick insulation.Note: Crane / Scaffolding as required for installation of the DG set & flue pipes shall be considered in scope.DG set shall be supplied with built-in acoustic enclosure as per latest pollution control board norms and as per specifications, complete in all respects.
The DG Set shall be complete with PCC-3.3 (Power Command Control) or equivalent DG Controller module suitable for AMF (auto-mains failure), Auto Load Sharing, electro-mechanical interlock & Interface with DG Synchronization panel for ACB/MCCB switching, Auto load sensing and Auto load Management, including communication card and networking gateway and software as required. Supply, installation, testing & commissioning of 990 liters capacity day oil storage tank (External) fabricated from 4 mm thick MS plates. Tank shall include 450 mm manhole cover, level indicator with duly calibrated scale and flanged connection for inlet, outlet, overflow, drain and probe provision for level controller & breather. Supply, installation, testing & commissioning of the following MS class ‘B’ pipes cut to required lengths and installed with all welded joints. Providing the necessary fittings like valves, bellows, elbows, tees, bends, reducers, sockets, hot dip galvanized supports and accessories including Hanger, Hardware and other accessories to make the installation complete as per site requirement.
Supply, installation, testing & commissioning of Battery Charger as described in Specifications and described below, suitable for 630 kVA DG sets:AC Input: 230 V + 10% AC, 50 Hz single phase.DC Output: To float / boost charge the batteries (with required AH as per D.G. rating) and also supply a continuous load as per offered DG set requirement.Current Rating: 30 A Float Mode: 27.0 V nominal (Adjustable) between 24-28.0 V.Boost Mode: 29.0 V nominal (Adjustable) between 24-32.0 V
Voltage Regulation: For AC input variation of 230 V + 10%. Frequency Variation of 50 Hz + 5%.Ripple: Less than 5%Note: Item rate shall be include the cable termination box suitable for termination of 3 Runs 3.5 C X 240 Sqmm. XLPE AL cables/ Bus Duct at alternator.
Supply, Installation, testing & Commissioning for the above Items.
Supply, installation, testing & commissioning of 320 KVA continuous rating (Prime power), 415 V, 3 phase, 4 wire, 50 Hz at 0.8 P.F, 1500 RPM, radiator cooled, silent diesel generating set along with complete fuel piping with accessories, anti vibration mounts, base frame, required hardware, Batteries, Engine control panel with accessories, residential silencer, flexible connection, bellow/expansion joints etc. with all associated equipment/work as per specifications to make the DG set installation complete in all respects as per site requirement. Engine & Alternator to be designed for 40 degree ambient temperature and the Alternator shall be with H class insulation. Silencer shall be with 75mm thick insulation.Note: Crane / Scaffolding as required for installation of the DG set & flue pipes shall be considered in scope.DG set shall be supplied with built-in acoustic enclosure as per latest pollution control board norms and as per specifications, complete in all respects.
The DG Set shall be complete with PCC-3.3 (Power Command Control) or equivalent DG Controller module suitable for AMF (auto-mains failure), Auto Load Sharing, electro-mechanical interlock & Interface with DG Synchronization panel for ACB/MCCB switching, Auto load sensing and Auto load Management, including communication card and networking gateway and software as required. Supply, installation, testing & commissioning of 990 liters capacity day oil storage tank (External) fabricated from 4 mm thick MS plates. Tank shall include 450 mm manhole cover, level indicator with duly calibrated scale and flanged connection for inlet, outlet, overflow, drain and probe provision for level controller & breather. Supply, installation, testing & commissioning of the following MS class ‘B’ pipes cut to required lengths and installed with all welded joints. Providing the necessary fittings like valves, bellows, elbows, tees, bends, reducers, sockets, hot dip galvanized supports and accessories including Hanger, Hardware and other accessories to make the installation complete as per site requirement.
Supply, installation, testing & commissioning of Battery Charger as described in Specifications and described below, suitable for 320 kVA DG sets:AC Input: 230 V + 10% AC, 50 Hz single phase.DC Output: To float / boost charge the batteries (with required AH as per D.G. rating) and also supply a continuous load as per offered DG set requirement.Current Rating: 30 A Float Mode: 27.0 V nominal (Adjustable) between 24-28.0 V.
Boost Mode: 29.0 V nominal (Adjustable) between 24-32.0 V Voltage Regulation: For AC input variation of 230 V + 10%. Frequency Variation of 50 Hz + 5%. Ripple: Less than 5% Note: Item rate shall be include the cable termination box suitable for termination of 3 Runs 3.5 C X 240 Sqmm. XLPE AL cables/ Bus Duct at alternator.
Supply, Installation, testing & Commissioning for the above Items.
Supply, installation, testing & commissioning of MS Class-B (Medium) exhaust pipe as per IS:1239 and all fixing accessories and hardware. The exhaust pipes shall be insulated with required thickness rockwool mattress / blanket insulation wrapped in chicken mesh and cladded with required gauge aluminium sheet including all structural supports as required for site condition and as per calculations / specifications.Insulation of flue pipe shall be 75mm thick, 150 kg/m3 density cladded with aluminium sheet of 22 gauge.Vendor to consider the Class 'B' (Medium) unto 150mm pipe and 6mm for above 150mm dia pipe. Size of pipe to be considered by the vendor depending upon the back pressure calculations.
2 x150 mm dia(w/o insulation)
2 x125 mm dia(w/o insulation)
Supply, installation, testing & commissioning of miscellaneous structural support (MS angle iron / MS Plates / MS Channel etc.) for horizontal & vertical exhaust piping at suitable interval as per approved Shop drawing including fabrication, hardware / flanges and painting (2 coats of primer and 2 coats of enamel paint) complete in all respect. The quantity given is indicative. Vendor shall identify the actual quantity as per site requirement, before award of work.
Additional Materials & Work Required Approvals from Statutory Authorities like pollution control board, electrical inspector etc. necessary to complete the job.
1 Hr. Site testing with available load at site with required consumables
For 630 /320 kVA DG Set
Factory testing as given below including required fuel:5 min. no load , 5 min. @15% load,5 min. @ 50% load, 5 min.@75% load, 10 min. @100% load, 10 min. @ 110% load(overload),
For 630/ 320 kVA DG Set
Supply, installation, testing & commissioning of following 1100 volt grade XLPE PVC insulated, FRLS sheathed copper conductor armoured cable including supplying of bimetallic crimping lugs, double compression glands, cable ternination, with earthing as per specification in existing trenches, cable trays ducts over bed of sand, clamped to wall with suitable clamps, including fixing bolts, connecting testing and commissioning.
4 C x 2.5 sq.mm control cable
7 C x 2.5 sq.mm control cable
12 C x 2.5 sq.mm control cable
Supply, installation, testing & commissioning of the following MS class ‘C’ pipes cut to required lengths and installed with all welded joints. Providing the necessary fittings like elbows, tees and reducers, sockets, hot dip galvanized supports and accessories including ceiling Hanger, Hardware complete as per site requirement.
25 mm dia MS pipes
Providing 25 mm dia. ball valves
EGP 304 Grade min. 1.5mm thk Pre-Fabricated Modular Operation Theatre Wall Panel and Ceiling panel backed with 12mm thick. Gypsum with proper supports as per specification.
Filling of Joints, Cavity and Antibacterial painting: - Filling of all joints & cavities with epoxy filler, sanded flush for seamless finish with one primer and three coats of antibacterial & antifungal paint. That is equivalent to a dry film thickness of 300 microns as per specification
Hermetically Sealed automatic sliding doors: - Automatically Operated hermetically sealed Sliding Doors of different size as required with glass vision window of 300mm x 300mm (WXH) along with all required accessories and in colour approved by client as per specification.
Door size 1500 mm X 2100 mm
Door size 1000 mm X 2100 mm
Laminar airflow System: - Laminar Plan air Ceiling system of size (2400mmx2400 mm) with unidirectional airflow with "S" class HEPA filter with an efficiency 99.97% down to 0.3 micron. The holding structure & top plenum are made up of Aluminium Sheet with a thickness of 1.6mm. It should be sealed with gasket conforming to DIN 4799 standards for the air distribution system. 2- layer diffuser with monofilament precision woven polyester of uniform porosity with an open area of sufficient resistance to create laminar from diffusers face and integral lighting provides an illumination level in excess of 15000 Lux in operating area and 10000 Lux other with flicker less digitally controlled steeples dimming down to 5%.
Electrical wiring - Electrical wiring within the OT Area, conduit pipes and electrical switch & Socket with Electrical Distribution board for Operating room with MCB's and Relay cards. All wiring should be done through ISI mark copper wire only with conduit pipe..
Peripheral lights:- Recess mounted IP 54 protocol, non-hygroscopic Peripheral Lights for clean room application. Each light set having 2 nos of 36 watt fluorescent lamps with digitally controlled dimmable ballast.
Scrub Sink:- scrub sink made out of 304 graded brushed finished stainless steel, with photo electric sensors,1 No. Mixture valve, 2 nos. solenoid valves with Foot operated switch as per specification.
Scrub Sink 2 - bay.
Writing board:- It should be flush mounted with a sterile jointing system, 1.50mm thick, white Ceramic board, bonded to a 2 mm steel sheet for additional rigidity. Approximate size of the same should be 940 x 600 mm.
X-ray view box:- Twin Plate X-Ray viewing screen with flicker free dimming light range from 15 to 100% with complete accessories as required to view the X-ray film.
Control Panel: - Touch Panel type Operation Theatre Control Panel (6 service Tiles) mounted. Flushed in the theatre wall with complete distribution board with all accessories. Following are the controls/display available: -* 1 no Day Time Digital Clock.* 1 no Elapsed Time Digital Clock.* 1 no Hands-Free Telephone system. * Peripheral Light Control* Medical Gas Alarm for 4 gases.*Temperature & Humidity Indicator.* Alarm for Vacuum.
Dirty Hatch box: - Dirty hatch box made up of Stainless-steel grade 304, having two doors on both side. One door will be opened at one time, indicator on both sides in case of door is open. The hatch will be designed in such a way that only one door will be opened at one time. The UV light will glow when both the doors are in closed position.
LED Operating light: - Ceiling mounted Operating room Dual Dome Light CE Notified or US FDA approved with provision of camera in it. 160000 Lux + 120000 Lux and o Colour rendering index CRI>95 and R9 ≥ 91 to 97 as per specification.
Ceiling Pendants:- Ceiling Pendent with weight carrying capacity of 100Kg. The pendant should have 10-12 electrical sockets, one monitor shelf and instrument Drawer IV Pole and infusion Pump Rod mount on it. system must be CE notified or US FDA approved for quality parameter. Gas outlets for pendants will be provide by user/department for compatibility with hospital wards.
Double Arm surgeon pendant
Single Arm Anaesthesia Pendant
SITC of Pressure relief damper:- Pressure Relief Damper. Made up of 304 graded stainless steel blades with all required accessories. It opens to maintain balanced positive pressure inside OT and prevent air contamination from outside.
Storage Cabinet:- Equipment Storage Unit is to be provided in operating theatre of dimension approved in the user. Approximate size of the unit should be 860(W) x1660(H) x350(D) mm and it should be flush mounted into the theatre wall with a sterile jointing system.
Anti - Static flooring:- 2mm thick Anti static, conductive dissipative flooring tile laid on a semi conductive adhesive base resistant to mechanical stress and dynamic load and washable. Its include all required flooring and levelling work for proper sloping of OT floors. it should be finished with proper sealed coving with wall to prevent water leakage in flooring at time of wash
Medical Gas pipeline system: inside OT FOR Medical Gases including all fitting and fixtures, that all pipes should be tapped through main corridor medical gas pipes by only
MEDICAL AIR COMPRESSOR SYSTEM, multi drive control mode, Reciprocating air compressor with foundation, Filtration system, receiver, electrical connection from compressor to control panel and all as required as per specification. Entire system shall be installed as a package and compatible to fulfil the demand of system. Product should be as per specification.Main component of system is as belowAir compressor with capacity 45CFM. (+/- 5%) with suitable motor as required (2 nos.)Air receiver tank 1500 ltrAir receiver tank 1500 ltrAir filtration Set as per specification (2 nos. for Duplex)Air d
Duplex MEDICAL VACUUM SYSTEM. The package shall consist of Reciprocating Vacuum pumps (including civil foundation and electrical wiring of suitable capacity from Pump to electrical panel and non-return valve complete) with suitable hp motorMain component of system is as belowReciprocating Vacuum Pump With capacity 2500 Ltr (+/- 5%) with suitable Motor (2 nos.)Pressure SwitchVacuum Receiver tank 2000 Ltr. (Total Capacity)Silencer muffler type
OXYGEN MANIFOLD minimum of 2x8 cylinders oxygen manifold extendable type with middle frame along with tail pipe as size given in the drawings having top frame comprising of high-pressure copper pipe with high pressure brass fitting made of high tensile brass, NRV and high-pressure copper tailpiece made of highpressure copper pipe. 1x8 bank shall be a reserve source of oxygen supply. It shall automatically supply the pipeline when primary source becomes exhausted or fails due to any reason. The system shall have source shut-off valve for easy changing and positioning, without hook. The cylinder should be placed with the help of cylinder brackets and fixing chains which should be zinc plated appropriate.
CE Marked compliant with HTM or NFPA Oxygen ChangeOver Reduction Box (Automatic Control Panel) of Digital fully Automatic type, capable of switching from “Bank in Use” to “Reserve Bank” without fluctuation in delivery line pressure and without the need for external electrical power. The Changeover panel shall be rated for min. 80 QMH at 400 kPA, and shall include the following accessories.Main component / feature of system is as belowPower Supply Module to provide power supply for alarm system displaySignalling Module for Pressure monitoring and Alarm ActivationDouble line pressure RegulatorHigh and Low Limit Pressure SwitchesChangeover and safety valvePressure Adjustment system (for working Pressure)Panel constructed with Stainless Steel material
Oxygen Emergency System (2+2): - The oxygen emergency system contains 4 nos. Gas cylinder manifold along with copper header, Brass Non-Return valve & High-pressure copper tail pipe for each cylinder.
NITROUS OXIDE MANIFOLD SYSTEM minimum of 2 x2 cylinders and reserve source of nitrous oxide will be 2x1 cylinders. Cylinder size shall be as given in the drawings having top frame comprising of high-pressure copper pipe with high pressure brass fitting made of high tensile brass, NRV, high pressure copper tailpiece made of high pressure copper. Reserve source of N2O shall automatically supply the pipeline when primary source of supply become exhausted or fails due to any reason.
CE marked Nitrous Oxide Change-Over Reduction Box (Automatic Control Panel conforming to HTM/ ISO) of Digital fully Automatic type, capable of switching from “Bank in Use” to “Reserve Bank” without fluctuation in delivery line pressure and without the need for external electrical power. The Changeover panel shall be rated for min. 50 QMH at 400 kPA, and shall include the following accessories.Main component / feature of system is as belowPower Supply Module to provide power supply for alarm system displaySignalling Module for Pressure monitoring and Alarm ActivationDouble line pressure RegulatorHigh and Low Limit Pressure SwitchesChangeover and safety valvePressure Adjustment system (for working Pressure)Panel constructed with Stainless Steel material
Nitrous Oxide Emergency Manifold: - The Nitrous Oxide Emergency system contains 2 Nos Gas cylinder manifold along with copper header, Brass Non-Return valve & High-pressure copper tail pipe for each cylinder and one number of high- pressure regulators
Combined Electrical Control Panel for Medical Air Compressors & Vacuum Pumps as per specification with all required support foundation complete
Terminal Outlets gas specific for the services accept only compatible quick connect Pin Index type adapters as HTM
Oxygen Outlet
Vacuum Outlet
MA-4 Outlet
SA-7 Outlet
Nitrous Oxide Outlet
Suitable Gas Outlet Adopter compatible with required ward Accessories made from stainless steel as per current latest standard.
Oxygen Outlet
Vacuum Outlet
MA-4 Outlet
SA-7 Outlet
Nitrous Oxide Outlet
Area Line Pressure Alarm must comply the BS EN ISO: 7396- 1:2016/BS EN 6061-1-8:2007/HTM02-01standard. The alarm system must be micro-processor based digital which monitor the pressure of medical gases like oxygen, medical air, vacuum, nitrous oxide etc. levels at a specific area piped gas system in the hospital. The electric circuit must be such that if the pressure vacuums in the gas pipeline drops below the preset limit, the equipment must give an audio –visual alarm. Visual alarm must remain active even after pressing of “Mute” button. It must come to normal condition only when gas pressure / vacuum return normal level. Each gas service must be displayed by colored LED’s to show Normal (Green) Low & High pressure (Red).
3 Services (Oxygen, MA-4, Vacuum)
4 Services (Oxygen, MA-4, Nitrous Oxide, Vacuum)
5 Services (Oxygen, MA-4, MA-7, Nitrous Oxide, Vacuum)
Area Zonal Valve Box shall meet the requirement of BS 5682 and HTM 02-01/EN/ NFPA-99 standards. The valve boxes shall be constructed of minimum 18 gauge CRCA sheet complete with a baked enamel finish. The valve box must be lockable having glass cover, the valve must be complete with stub pipes that extend to the outside of the box to enable easy connection to the MGPS. The valve box must be equipped with gauge for the gases. The valve box unit module must consist of 1 to 5 area valve service units.
3 Services (Oxygen, MA-4, Vacuum)
4 Services (Oxygen, MA-4, Nitrous Oxide, Vacuum)
5 Services (Oxygen, MA-4, MA-7, Nitrous Oxide, Vacuum)
Modular bed head panel, with provision of gas outlet, electrical, 1200 mm long, made of high grade of aluminium. Fabricated by extrusion method and powder coated as per approved colors.as per specification and drawing
Copper pipes, for Medical Gases, complete with elbows, flanges, specials, others fittings, and steel supports. The copper pipe should be of solid drawn seamless deoxidized, un-arsenical, tempered and of degreased material conforming to BS-EN 13348/ASTM B819, of copper pipe. must be certified and inspected by third party inspection agency like LLoyds/SGS/TUV etc
Isolation valve - All valves are to be ball valves type and PTFE or Teflon seals. They shall be suitable for a working pressure of 10.2 Kg/cm² gauge. Valves shall be fitted into the pipeline by means of capillary hard soldered joints containing silver. it should be open/close with help of handle with rotation of 90 degree.
PART-C (MEDICAL GAS PIPELINE SYSTEM ACCESSORIES) Oxygen Flow Meter - Made from brass, chrome plated. It shall be back pressure compensated type having housing of Polycarbonate autoclavable reusable flow range 0-15 LPM. Fitted with matching adopter for oxygen outlet point and humidifier shall be compatible with flowmeter.
SUCTION UNITS:Ward Vacuum Unit - Regulator capable of controlling vacuum between 0 to 760 mm Hg and Polycarbonate autoclavable, reusable type receiver jar of not less 600 ml. Vacuum regulator shall have a dial gauge, on/off switch, valve control knob and as per specifications and as required.
Low pressure suction tube for suction outlet adopter as required
Operation Theatre Suction Trolley- having 2 Nos. 2000 ml receiver jars of Polycarbonate autoclavable up to 121 *C, reusable and mounted on trolley with wheel arrangement. The trolley shall have one number of vacuum regulators having regulation control between 0-760 mm Hg and interconnecting suction tubes
OT Conversion kit attached with 5 Mtr Long HP tube with appropriate colour code for specific gas.
KIT for oxygen
KIT for Nitrous Oxide
Kit for Air 4
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.15.7.1 In mud mortar cum 503.00 15.7.2 In lime mortar with old mughal bricks cum 1271.95 15.7.3 In lime mortar cum 607.50 15.7.4 In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.1 Of area 3 sq. metres and below)
15.12.2 Of area beyond 3 sq. metres
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :15.9.1 In lime mortar
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: 15.28.1 G.S. Sheet
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead :15.14.1 Of sectional area 40 square centimetres and above
M/S Shiv Kumar Agarwal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid