| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC PACHPADRA ROAD OPP MILK DAIRY BALOTRA TEHSIL PACHPADRA DISTT BALOTRA RAJ | GANGANAGAR | RAJASTHAN | 335001 | ₹23.9 L Quoted ₹25.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹25.8 LRejected-Finance 8 99 6 P NO 16 PEERZADIGUDA NARAPALLY HYDERABAD HYDERABAD TELANGANA 500039 | MEDCHAL MALKAJGIRI | TELANGANA | 500039 | ₹25.8 L | L2 | Rejected-Finance Not Lowest Bidder, Hence rejected |
| 3 | L3₹26.8 LRejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 UDYAM GJ 05 0006749 24AACFK2418A1Z4 B R MSME STATUS AS VERIFIED | BHAVNAGAR | GUJARAT | 364001 | ₹26.8 L | L3 | Rejected-Finance Not Lowest Bidder, Hence rejected |
| 4 | L4₹26.9 LRejected-Finance 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | ₹26.9 L | L4 | Rejected-Finance Not Lowest Bidder, Hence rejected |
| 5 | L5₹27.4 LRejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | ₹27.4 L | L5 | Rejected-Finance Not Lowest Bidder, Hence rejected |
| Sl No | Description | Qty | Unit | KRISHNA CONSTRUCTION COMPANY L3 | M/S SOLANKI GENERAL SUPPLIERS L5 | M/S Tanisha Traders L7 | Mahaveer Traders L4 | Deccan Enterprises L2 | M/S BHERA RAM & SONS L1 | Veer Builders L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum BEE-5 star rating and EER 3.2.of capacity 1.5 TR having condensing unit to withstand outside environment temp 55 °C complete all as specified and directed. | 7 | EACH | 55,000 ₹3.9 L | 65,072.45 ₹4.6 L | 66,896.91 ₹4.7 L | 66,410.38 ₹4.6 L | 63,856.14 ₹4.5 L | 60,815.37 ₹4.3 L | 68,964.63 ₹4.8 L |
| 2.00 | Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed. | 7 | EACH | 6,000 ₹42,000 | 7,032.04 ₹49,224.28 | 7,229.2 ₹50,604.40 | 6,834.88 ₹47,844.16 | 6,572 ₹46,004 | 6,572 ₹46,004 | 7,097.76 ₹49,684.32 |
| 3.00 | S & F copper pipe size 1/4'' size including connected two copper pipe by brazing complete all as specified and directed. | 10 | Ft | 300 ₹3,000 | 50.29 ₹502.90 | 51.7 ₹517 | 48.88 ₹488.80 | 47 ₹470 | 47 ₹470 | 50.76 ₹507.60 |
| 4.00 | S & F copper pipe size 1/2'' size including connected two copper pipe by braging complete all as specified and directed. | 10 | Ft | 250 ₹2,500 | 65.27 ₹652.70 | 67.1 ₹671 | 63.44 ₹634.40 | 61 ₹610 | 61 ₹610 | 65.88 ₹658.80 |
| 5.00 | Single pole and neutral enclosure with a two pin and earth, plug and socket complete with one single pole MCB 20amp complete all as specified & directed. | 7 | EACH | 700 ₹4,900 | 1,945.05 ₹13,615.32 | 1,999.58 ₹13,997.06 | 1,890.51 ₹13,233.58 | 1,817.8 ₹12,724.60 | 1,817.8 ₹12,724.60 | 1,963.22 ₹13,742.57 |
| 6.00 | S & F in of PVC insulated 3 core copper PVC insulated FRLSH cable of size 4.0 Sqmm, flexible cables, 1100 Volts and confirming to IS: 694 complete all as specified and directed | 15 | RUNNING METRE | 200 ₹3,000 | 113.42 ₹1,701.30 | 116.6 ₹1,749 | 110.24 ₹1,653.60 | 106 ₹1,590 | 106 ₹1,590 | 114.48 ₹1,717.20 |
| 7.00 | supply and fix Air conditioner wall mounted metal bracket heavey duty for outdoor unit of split AC's 1.5/2.0 TR capacity complete all as specified and directed | 7 | EACH | 4,000 ₹28,000 | 652.7 ₹4,568.90 | 671 ₹4,697 | 634.4 ₹4,440.80 | 610 ₹4,270 | 610 ₹4,270 | 658.8 ₹4,611.60 |
| 8.00 | S&F wiring for circuit/Sub main wiring along with earth wire with 2x4.0 sq. mm + 1x2.5 sqmm of FR PVC insulated copper multi stranded conductor single core cable drawing through PVC casing and caping of adiquate size complete all as specified (Note:- 2 lengths of 6 Sqmm cable, & 1 length of 2.5 sqmm with PVC casing caping will be measured as one length). | 75 | RUNNING METRE | 300 ₹22,500 | 226.39 ₹16,979.30 | 232.74 ₹17,455.35 | 220.04 ₹16,503.24 | 211.58 ₹15,868.50 | 211.58 ₹15,868.50 | 228.51 ₹17,137.98 |
| 9.00 | S&F wiring for circuit/Sub main wiring along with earth wire with 4x6.0 sq. mm + 2x4.0 sqmm of FR PVC insulated copper multi stranded conductor single core cable drawing through PVC casing and caping of adiquate size complete all as specified (Note:- 4 lengths of 6 Sqmm cable, & 1 length of 4.0 sqmm with PVC casing caping will be measured as one length). | 25 | RUNNING METRE | 200 ₹5,000 | 498.95 ₹12,473.79 | 512.94 ₹12,823.53 | 484.96 ₹12,124.06 | 466.31 ₹11,657.75 | 466.31 ₹11,657.75 | 503.61 ₹12,590.37 |
| 10.00 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. complete all as specified and directed. | 7 | EACH | 360 ₹2,520 | 304.09 ₹2,128.66 | 312.62 ₹2,188.34 | 295.57 ₹2,068.98 | 284.2 ₹1,989.40 | 284.2 ₹1,989.40 | 306.94 ₹2,148.55 |
Updated dates
Tender Value
₹23.8 L
EMD Value
₹47,560
Closing Date
30 Dec 2025, 6:00 pmClosed
Shri Ayan Saha, IDSE, EE
GE(AF) Phalodi PIN-342301
PROVN OF AIR CONDITIONING, EARTING PITS AND FOL STORE AT DIFFERENT UNITS OF AF STATION PHALODI.
2025_MES_742007_1
8758/A/E8
Open Tender
Civil Works
180 days
Air Force Station Phalodi
As per tender docs.
7 documents required · 7 mandatory
₹500
GE(AF) Phalodi
₹47,560
Yes
24 Jan 2026
28 Nov 2025
6 Jan 2026
28 Nov 2025
30 Dec 2025
15 Dec 2025
Amount
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum BEE-5 star rating and EER 3.2.of capacity 1.5 TR having condensing unit to withstand outside environment temp 55 °C complete all as specified and directed.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed.
S & F copper pipe size 1/4'' size including connected two copper pipe by brazing complete all as specified and directed.
S & F copper pipe size 1/2'' size including connected two copper pipe by braging complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth, plug and socket complete with one single pole MCB 20amp complete all as specified & directed.
S & F in of PVC insulated 3 core copper PVC insulated FRLSH cable of size 4.0 Sqmm, flexible cables, 1100 Volts and confirming to IS: 694 complete all as specified and directed
supply and fix Air conditioner wall mounted metal bracket heavey duty for outdoor unit of split AC's 1.5/2.0 TR capacity complete all as specified and directed
S&F wiring for circuit/Sub main wiring along with earth wire with 2x4.0 sq. mm + 1x2.5 sqmm of FR PVC insulated copper multi stranded conductor single core cable drawing through PVC casing and caping of adiquate size complete all as specified (Note:- 2 lengths of 6 Sqmm cable, & 1 length of 2.5 sqmm with PVC casing caping will be measured as one length).
S&F wiring for circuit/Sub main wiring along with earth wire with 4x6.0 sq. mm + 2x4.0 sqmm of FR PVC insulated copper multi stranded conductor single core cable drawing through PVC casing and caping of adiquate size complete all as specified (Note:- 4 lengths of 6 Sqmm cable, & 1 length of 4.0 sqmm with PVC casing caping will be measured as one length).
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. complete all as specified and directed.
S&F in MCB TPN 63 Amps C curves MCB repturing capacity 16 KA etc complete all as specified and directed.
Supply and fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting SPN, 12 way, 230 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc complete all as specified and directed.
M&L for chemical earthing with copper earth plate electrode 90 cm X 60 cm X 5 mm buried directly in ground (earth pit not less than 3.0 mtr deep beliow ground level) with top edge of the plate not less than 2.25 mtrs below normal ground level,connecting to copper strip 32 X6 mm as earthing strip by means of bolts,nut check nut and washers protected with and including 65 mm dia light grade GI pipe,necessary excavation and earth work,magnesium sulphate (80 Kg) ),charcoal and common salt filling,watering arrangement with 40 mm GI pipe medium grade including PCC pit with pre cast RCC (1:2:4) cover ,GI funnel with test point,testing all as specified and directed.
S&F Copper strip 32 x 6mm with saddels and fixing screws for roof conductors and down conductors avobe ground ,Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or fixed to wall on insulators or any other indicated situation for loop earthing etc as required 32 x6 mm copper strip complete all as specified and as directed
S&F Copper strip 20 x 3.15mm with saddels and fixing screws for roof conductors and down conductors avobe ground ,Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or fixed to wall on insulators or any other indicated situation for loop earthing etc as required 20X3.15mm copper strip complete all as specified and as directed
M&L earthing complete with galvanised steel earth plate electrode 60cm x 60cm X3.15 mm thick, buried directly in ground (earth pit not less than 3.0 mtr deep beliow ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level,connected to and including copper strip of size 20 x 3.15mm as earthing lead by means of bolts,nut check nut and washers of galvanised iron all as shown inin electrical plate No 5 of MES SSR Part I and testing on completion including excavation and earth work in any type of soil,PCC (1:3:6) type C1 chamber ,MS frame and cover 6 mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric or XPM (weight not less than 4 Kg per Sqm) with cast iron frame,funnel with wire mesh,GI watering pipe 20 mm dia medium grade and lugs complete all as specified and directed with earth resistance not more than 1.0 Ohms. Writing of details on the surface of the pit with paint complete all as specified and as directed
M&L Test point terminal block made of Phosphorous bronze size 75 x 75 x 25 mm drilled & screwed incl 3 Nos, 8mm dia, 25mm long Hexagonal head Screw complete all as specified and as directed .
S & F porcelain insulators with fixing on floor/walls/roof etc by grouting by nuts,bolts, washers, screws etc complete all as specified and as directed
S&F Air termination , single pointed copper rod 12 mm dia and 300 mm long complete all as specified and as directed.
Supplying and laying/fixing GI tubing light grade 40 mm dia for encasing strip for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or as mounting bracket bend to shape with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works all as specified and directed.
Supply and fixing earth value /Type indicator metal sheet post made of MS and sheet ,post height 1.0 Mtr, sheet size 300 mm X 300 mm X 3 mm) pole including two coat of synthetic enamel(yellow/Red/Black) paint & fixied on PCC 1:2:4 complete all as specified and directed
Excavation in trenches in hard soil not exc 1.5mtr wide and not exc 1.5mtr in depth for taking out old pipe and laying new pipe line etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified and as directed.
Returning and filling including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and as directed.
Removing surplus hard soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
Supply ,laying, jointing and testing of GI tubing medium grade 20 mm bore with all fittings laid in trenches complete all as specified and directed.
Supply ,laying, jointing and testing of GI tubing medium grade 15 mm bore with all fittings laid in trenches complete all as specified and directed.
S & F short body Bib tap screwed one end for iron pipe size 15 mm dia butterfly handle type complete all as specified and directed.
Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into in stove enamelled steel conduit conduits including all fitting and fixing accessories( bend, tee, junction box etc) on surface/concealed conduit of size 20mm heavy duty ISI marked , fire proof steel terminal sunken boxes for One light/ Fan Point controlled by one switch including 1.5 sqmm copper conductor cable FRLSH connected to common earth dolly complete all as specified and as directed .
Supply and Fixing LED flameproof light 1X16/20 Watt, 4' long with die cast alluminium housing with heat resistance toughten glass with LED tube light fixture driver, holder, connector etc prewired including connecting up with 3 core copper cable in steel flexible pipe complete all as specified and directed.
S&F flame proof / weather proof Exhaust fan 12" single phase with louvers complete all as specified and as directed.
S&F flame proof / weather proof LED Bulkhead light fitting complete with 10 watt LED and making necessary electric connection to ceiling rose with copper condutor of suitable size & length complete all as specified and directed.
S&F flame proof switch rotary type with termination box in LM 6,16 Amp , Single pole ON-OFF, 240 Volt Complete all as specified and as directed.
S&F flame proof/ WP enclosure for control panel / Distribution panel Incoming 63 Amps ,240 Volt , out going terminal chamber Out Going MCB 63 Amp DP-01 No , 10Amp SP-04 Nos , 32 Amp SP-04Nos, 40 Amp SP-04 Nos Complete all as specified and as directed .
S&F flame proof / weather proof LED Flood light fitting 60Watt complete all as specified and as directed.
S&F Copper strip 25 x 3.15mm with saddels and fixing screws for roof conductors and down conductors avobe ground ,Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or fixed to wall on insulators or any other indicated situation for loop earthing etc as required 25X3.15mm copper strip complete all as specified and as directed
Supply and fix Air termination , single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and directed.
M & L for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep below normal ground level), with top edge of the plate vertically to depth of not less than 1.5 m below normal ground level connected to and incl GI strip 25x4 mm and GI pipe 40 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl PCC cover and , watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete all as specified and directed. ( Note : PCC chamber shall be constructed at least 1.5m away from earth pit pipe for watering shall be provided in slanting manner.)
Surface dressing n exc 15 cm deep and getting out in any kind of soil complete all as specified and directed.
Excavating in trenches, n.exc 1.5m wide and n exc 1.5m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10sq m on plan and n.exc 1.5m in depth and getting out in Hard/dense soil complete all as specified and directed.
Add to Item No 39 for each additional 1.50m or part thereof in depth beyand the first 1.5m complete all specified and directed.
M&L for 100 mm thick PCC 1:4:8, type D2 as in foundations, filling and mass concrete using 40 mm graded stone aggregate complete all as specified and directed.
M&L Pre-cast cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in Cement mortar 1:6, complete all as specified and directed.
M&L reinforced cement concrete M-25 (Design mix) using 20mm graded stone aggregate in foundations including rafts, footings, foundation beams, plinth beams, bases for columns, under reamed piles and mass concrete complete all as specified and directed.
M&L reinforced cement concrete M-25 (Design mix) using 20mm graded stone aggregate in columns, pillars, piers, posts, struts and the like complete all as specified and directed.
M&L reinforced cement concrete M-25 grade (Design mix) using 20mm graded stone aggregate in Beams, lintels upto 1.5m clear span, chajjas seismic and other similar bands, lintel bands, roof bands and the like complete all as specified and directed.
M&L RCC M-25 (Design mix) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for use and waste of rough finish formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed
M&L for use and waste of rough finish formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for use and waste of rough finish formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished flat surfaces of concrete complete all as specified and directed.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20cm wide for rough finished surfaces complete all as specified and directed.
M&L Mild steel bars TMT 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per 52 here-in before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L rendering 10mm thick in cement mortar 1:6 on fair faces of brick/block masonary or on concrrete surfaces in CM 1:6, finished even & smooth without using extra cement complete all as specified.
M&L rendering 5mm thick on ceiling surfaces in CM 1:3 finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15mm thick surface other than fair faces of brick/block masonry work or concrete surface in two layers (5mm thick CM 1:4 over 10mm in CM 1:6) finished even and smooth without using extra cement mixed with water proofing compound @ 3% of cement on top layers complete all as specified and directed. (Note WPC measured and paid separately.)
M&L rendering 10mm thick on concrete surface over the roof in CM 1:4, finished even and smooth without using extra cement mixed with water proofing compound @ 3% of cement complete all as specified and directed. (Note WPC measured and paid separately.)
Supply only Integral water proofing compound compete all as specified and directed.
M&L for cement plastered surfaces with one coat of cold applied bituminous primer @ 0.40 ltr/Sqm conforming to IS-33894 and laying APP based polymeric membrane not less than 3mm thick, weighing not less than 3.5kg/sqm, reinforced with polyester non woven fabric (weighing not less than 150gms/sqm) and upper side of the membrane thermally insulated with white mineral gravel, uniformly embedded during manufacturing process shall only be used. It shall be laid by torch application. Side over laps shall be 75mm and the end lap shall be 100mm and all over laps and joints shall be sealed by torch application. For parapets, membrane shall be taken to a height of minimum 60cm and then inserted inside the parapet groove. This shall be finished by a membrane flashing complete all as specified and directed.
M&L for Framed work of Fe-290 (Gde E165) as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F steel door including projecting type hinges, steel handle, complete with glazing bars, dovetailed or welded complete all as specified and directed.
M&L preparation of new steel surfaces of any description over exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Earth filling under floors including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick cement conrete 1:4:8 type D2 (using 40mm grade stone aggregate) as in sub base of floors complete all as specified and directed.
M&L for 55 mm thick PCC 1:2:4 type B0 as in floor finishes complete all as specified and directed.
M&L for 75 mm thick, plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregates) as in plinth protection finished even and smooth w/o using extra cement with joints 10mm wide and in full depth at corners and @ 3. m c/c filled with mastic mortar complete all as specified and directed.
M&L for coloured non skid ceramic tiles 7 to 8mm thick (square / rectangular ) area of each tiles exc 0.18 sqm but not exceeding 0.38 Sqm in floor (600 mmX 600 mm) etc set and jointed in neat cement slurry screed bed 15mm thick in 1:6 and pointed in coloured cement to match with coloured tiles complete all as specified and directed.
M&L for preparing on newly plastered wall surfaces and applying two coats of cement base paint of 1st grade quality white or tinted in one or more tints and pattern (camouflage) as approved, over a coat of primer complete all as sepcified and directed.
M&L for preparing newly plastered surfaces and applying three coats of white wash as in ceiling etc complete all as sepcified and directed.
M&L for preparing newly plastered surfaces and applying three coats of white wash as on walls etc complete all as sepcified and directed.
S&F in replacement LT feeder pillar box factor made cubical type dust proof, out door type both side opening of size 100 x 80 x 40 cm of MS sheet 3 mm thick power coated machine pressed front opening with rubber gasket / bedding , locking arrangement with sliding bolt including aluminium bus bar of 400 amps 4 strips mounted on insulators each strip should be munted minimum two insulator and nut bolt panel shall be mounted on angle iron frame and legs made from angle iron of suitable size duly spray painted internally and externally with two coat of synthetic enamel paint over a coat of red oxide primer grouted in PCC 1:2:4 type ‘B’ ( using 20 mm graded stone aggregate complete incoming / outgoing cable provision complete all as specified and directed.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
M&L for dry tibba sand in trenches for cushioning to under ground cable spreading, levelling, hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm, laid by dry and abutting each other with gap between adjacent slab not exedding 10 mm over under ground cable for protection complete all as specified and directed.
Material & labour for Providing, cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregate for pole base foundation and coping complete all as specified and directed.
Material and labour for 40mm graded stone aggregate for spreadng/ loose filling under four pole structure, E/M installation and other places complete all as specified and directed.
Deccan Enterprises (BID ID -3511696)
KRISHNA CONSTRUCTION COMPANY (BID ID -3510825)
Mahaveer Traders (BID ID -3511568)
M/S SOLANKI GENERAL SUPPLIERS (BID ID -3511166)
Veer Builders (BID ID -3511499)
M/S Tanisha Traders (BID ID -3511273)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
tender.pdf
Tender Documents • 1.43 MB
BOQ_830884.xls
BOQ • 0.28 MB